HomeMy WebLinkAboutDWQ-2023-126158STATE OF UTAHDIVISION OF WATER QUALITYDEPARTMENT OF ENVIRONMENTAL QUALITYSALT LAKE CITY, UTAHUTAH POLLUTANT DISCHARGE ELIMINATION SYSTEM (UPDES) PERMITSMajor IndustrialPermit No. UT0025755In
compliance with provisions of the Utah Water Quality Act, Title 19, Chapter 5, Utah Code (the "Act"),ATI TITANIUM LLCis hereby authorized to discharge from ATI TITANIUM ROWLEY OPERATIONto
receiving waters named The Great Salt Lake,in accordance with specific limitations, outfalls, and other conditions set forth herein.This permit shall become effective on March 1, 2024This
permit expires at midnight on February 28, 2029.Signed this day of February, 2024._________________________John K. Mackey, P.E. Director
DWQ-2023-126158Table of ContentsOutline Page NumberI. DISCHARGE LIMITATIONS
AND REPORTING REQUIREMENTS4A. Description of Discharge Points4B. Narrative Standard4C. Specific Limitations and Self-Monitoring Requirements4D. Reporting of Monitoring Results9II.
PRETREATMENT REQUIREMENTS10III. BIOSOLIDS REQUIREMENTS13IV. STORM WATER REQUIREMENTS14V. MONITORING, RECORDING & GENERAL REPORTING REQUIREMENTS15A. Representative Sampling15B.
Monitoring Procedures15C. Penalties for Tampering15D. Compliance Schedules15E. Additional Monitoring by the Permittee15F. Records Contents15G. Retention of Records15H. Twenty-four
Hour Notice of Noncompliance Reporting15I. Other Noncompliance Reporting16J. Inspection and Entry16VI. COMPLIANCE RESPONSIBILITIES18A. Duty to Comply18B. Penalties for Violations
of Permit Conditions18C. Need to Halt or Reduce Activity not a Defense18D. Duty to Mitigate18E. Proper Operation and Maintenance18F. Removed Substances18G. Bypass of Treatment Facilities18H.
Upset Conditions20VII. GENERAL REQUIREMENTS21A. Planned Changes21B. Anticipated Noncompliance21C. Permit Actions21D. Duty to Reapply21E. Duty to Provide Information21F. Other
Information21G. Signatory Requirements21H. Penalties for Falsification of Reports23I. Availability of Reports23J. Oil and Hazardous Substance Liability23K. Property Rights23L.
Severability23M. Transfers23N. State or Federal Laws23O. Water Quality - Reopener Provision24P. Biosolids – Reopener Provision24Q. Toxicity Limitation - Reopener Provision24VIII.
DEFINITIONS25A. Wastewater25
DISCHARGE LIMITATIONS AND REPORTING REQUIREMENTS
Description of Discharge Points. The authorization to discharge wastewater provided under this part is limited to those outfalls specifically designated below as discharge locations.
Discharges at any location not authorized under a UPDES permit are violations of the Act and may be subject to penalties under the Act. Knowingly discharging from an unauthorized location
or failing to report an unauthorized discharge may be subject to criminal penalties as provided under the Act.Outfall NumberLocation of Discharge Outfall001Located at latitude 40°56'19"
and longitude 112°42'12". The discharge is through a 12-inch HDPE pipe to an unnamed ditch to the Great Salt Lake.
Narrative Standard. It shall be unlawful, and a violation of this permit, for the Permittee to discharge or place any waste or other substance in such a way as will be or may become
offensive such as unnatural deposits, floating debris, oil, scum, or other nuisances such as color, odor or taste, or cause conditions which produce undesirable aquatic life or which
produce objectionable tastes in edible aquatic organisms; or result in concentrations or combinations of substances which produce undesirable physiological responses in desirable resident
fish, or other desirable aquatic life, or undesirable human health effects, as determined by a bioassay or other tests performed in accordance with standard procedures.
Specific Limitations and Self-Monitoring Requirements.
Effective March 1, 2024, and lasting through the life of this permit, there shall be no acute or chronic toxicity in Outfall 001 as defined in Part VIII, and determined by test procedures
described in Part I. C.4. a & b of this permit.
Effective immediately and lasting the duration of this permit, the Permittee is authorized to discharge from Outfall 001. Such discharges shall be limited and monitored by the Permittee
as specified below:
Parameter
Effluent Limitations1
Maximum Monthly Avg
Maximum Weekly Avg
Annual Loading
Daily Minimum
Daily Maximum
Total Flow, MGD
-
-
-
-
1.0
Iron, mg/L
4.7
-
-
-
-
Selenium, mg/L
0.015
-
-
-
-
Selenium, lbs/year
-
-
45.6
-
-
Titanium, mg/L
12.1
-
-
-
-
Oil & Grease, mg/L
-
-
-
-
10.0
pH, Standard Units
-
-
-
6.5
9
WET, Chronic Biomonitoring2
-
-
-
-
IC25> 100% effluent
See Definitions, Part VIII, for definition of terms
The WET Requirements are for Ceriodaphnia variegatus (sheep head minnows), and are monitoring only. There is no limit associated with this testing.
Self-Monitoring and Reporting Requirements 1, 2
Parameter
Frequency
Sample Type
Units
Total Flow3, 4
Continuous
Recorder
MGD
TSS, Effluent
Weekly
Grab
mg/L
pH
Weekly
Grab
SU
Oil & Grease
Monthly
Grab
mg/L
WET – Chronic Biomonitoring 5
Quarterly
Composite
Pass/Fail
TDS
Monthly
Grab
mg/L
Metals6
Iron, Effluent
Weekly
Composite
mg/L
Selenium, Effluent
Weekly
Composite
mg/L
Titanium, Effluent
Weekly
Composite or Grab
mg/L
Aluminum, Effluent
Monthly
Composite
mg/L
Arsenic, Effluent
Quarterly
Composite
mg/L
Chromium, Effluent
Quarterly
Composite
mg/L
Arsenic, Effluent
Quarterly
Composite
mg/L
Cadmium, Effluent
Quarterly
Composite
mg/L
Copper, Effluent
Quarterly
Composite
mg/L
Lead, Effluent
Quarterly
Composite
mg/L
Nickel, Effluent
Quarterly
Composite
mg/L
Silver, Effluent
Quarterly
Composite
mg/L
Zinc, Effluent
Quarterly
Composite
mg/L
Mercury Effluent 7
Quarterly
Grab
mg/L
Cyanide, Effluent
Quarterly
Grab
mg/L
See Definitions, Part VIII, for definition of terms.
While the outfall is deactivated and not discharging, the Permittee (ATI Titanium) is not required to monitor the effluent. Upon resumption of the discharge, monitoring is required.
Flow measurements of influent/effluent volume shall be made in such a manner that the Permittee can affirmatively demonstrate that representative values are being obtained.
If the rate of discharge is controlled, the rate and duration of discharge shall be reported.
The WET Requirements are for Ceriodaphnia variegatus (sheep head minnows), and are monitoring only. There is no limit associated with this testing.
Metals samples should be analyzed using a method that meets Method Detection Limits (MDL) requirements. If a test method is not available the Permittee must submit documentation to the
Director regarding the method that will be used. The sample type (composite or grab) should be performed according to the methods requirements.
Upon restart of the facility they will continue to use the EPA Method 1631 and make sure they are following the SOP for the method for one (1) year. After that year, if the results are
all below 15 nanograms per liter (15 ng/L = 0.000015 mg/L) they may switch to a less sensitive EPA approved method.
Compliance Schedule
There is no Compliance Schedule included in this renewal permit.
Acute/Chronic Whole Effluent Toxicity (WET) Testing.
Whole Effluent Testing – Acute Toxicity.The requirement to monitor for whole effluent toxicity (WET) Acute Toxicity has not been included in this permit. This permit may be reopened
and modified (following proper administrative procedures) to include, WET limitations, a compliance date, a compliance schedule, a change in the WET protocol, additional or modified
numerical limitations, or any other conditions related to the control of toxicants in accordance with Part VII, Q of this permit. Whole Effluent Testing – Chronic Toxicity. Chronic
WET tests are considered an indicator for Class 5 waters (Great Salt Lake) because of uncertainties regarding the representativeness of the standard test species for Great Salt Lake.
If a separate acute test is not conducted, the results of the acute duration portion of a chronic test are reported as specified in Part a. Whole Effluent Testing – Acute Toxicity. As
an indicator, the chronic test results can demonstrate compliance with portions of the Narrative Standards (R317-2-7.2). However, the chronic WET test results alone do not demonstrate
noncompliance with the Narrative Standards. As indicators, the chronic WET test results alone are not used for determining reasonable potential for toxicity or noncompliance with the
permit.Starting on March 1, 2024, the Permittee shall quarterly conduct chronic static renewal toxicity tests on a composite sample of the final effluent at Outfall 001. The sample
shall be collected at the point of compliance before mixing with the receiving water.
Three samples are required and samples shall be collected on Monday, Wednesday and Friday of each sampling period. This may be changed with Director approval. The chronic toxicity tests
shall be conducted in general accordance with the procedures set out in the latest revision of Short-Term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Water
to Marine and Estuarine Organisms, Third Edition, October 2002 EPA-821-R-02-014 as per 40 CFR 136.3(a) TABLE IA-LIST OF APPROVED BIOLOGICAL METHODS.Test species shall consist of Cyprinodon
variegatus (sheepshead minnow).A multi dilution test consisting of at least five concentrations and a control is required at two dilutions below and two above the receiving water concentration(RWC),
if possible. If test acceptability criteria are not met for control survival, growth, or reproduction, the test shall be considered invalid. A valid replacement test is required within
the specified sampling period to remain in compliance with this permit. Chronic toxicity occurs when, during a chronic toxicity test, the 25% inhibition concentration (IC25) calculated
on the basis of test organism survival and growth or survival and reproduction, is less than or equal to 100% effluent concentration (equivalent to the RWC). If a sample is found to
be chronically toxic during a routine test, the monitoring frequency shall become biweekly (see Part I.4.c.Accelerated Testing).The Director may enter acceptable variations in the test
procedure here as documented in the Fact Sheet Statement of Basis and based on the test acceptability criteria as contained in Utah Pollutant Discharge Elimination System (UPDES) Permitting
and Enforcement Guidance Document for Whole Effluent Toxicity Control February, 2018. If possible, dilution water should be obtained from the receiving stream.
If the permit contains a total residual chlorine limitation such that it may interfere with WET testing (>0.20 mg/L), the Permittee may dechlorinate the sample in accordance with the
standard method. If dechlorination is negatively affecting the test, the Permittee may collect the sample just before chlorination with Director approval.
Quarterly test results shall be reported along with the Discharge Monitoring Report (DMR) submitted for the end of the required reporting period (e.g., biomonitoring results for the
calendar quarter ending March 31 shall be reported with the DMR due April 28, with the remaining biomonitoring reports submitted with DMRs due each July 28, October 28, and January 28).
Monthly test results shall be reported along with the DMR submitted for that month. The format for the report shall be consistent with Appendix C of “Utah Pollutant Discharge Elimination
System (UPDES) Permitting and Enforcement Guidance Document for Whole Effluent Toxicity, Utah Division of Water Quality, February, 2018. If the results for ten consecutive tests indicate
no chronic toxicity, the Permittee may submit a request to the Director to allow a reduction in chronic toxicity testing by alternating species, or using only the most sensitive species.
The permit issuing authority may approve or deny the request based on the results and other available information without public notice. If the request is approved, the test procedures
are to be the same as specified above for the test species. Under no circumstances shall monitoring for WET at major facilities be reduced less than quarterly. Minor facilities may
be less than quarterly at the discretion of the Director.
Accelerated Testing. When whole effluent toxicity is indicated during routine WET testing as specified in this permit, the Permittee shall notify the Director in writing within 5 days
after becoming aware of the test result. The Permittee shall perform an accelerated schedule of WET testing to establish whether a pattern of toxicity exists unless the Permittee notifies
the Director and commences a PTI, TIE, or a TRE. Accelerated testing or the PTI, TIE, or TRE will begin within fourteen days after the Permittee becomes aware of the test result. Accelerated
testing shall be conducted as specified under Part I. Pattern of Toxicity. If the accelerated testing demonstrates no pattern of toxicity, routine monitoring shall be resumed.
Pattern of Toxicity. A pattern of toxicity is defined by the results of a series of up to five biomonitoring tests pursuant to the accelerated testing requirements using a full set
of dilutions for acute (five plus the control) and five effluent dilutions for chronic (five plus the control), on the species found to be more sensitive, once every week for up to five
consecutive weeks for acute and once every two weeks up to ten consecutive weeks for chronic.
If two (2) consecutive tests (not including the scheduled test which triggered the search for a pattern of toxicity) do not result in an exceedance of the acute or chronic toxicity criteria,
no further accelerated testing will be required and no pattern of toxicity will be found to exist. The Permittee will provide written verification to the Director within 5 days of determining
no pattern of toxicity exists, and resume routine monitoring.A pattern of toxicity may or may not be established based on the following: WET tests should be run at least weekly (acute)
or every two weeks (chronic) (note that only one test should be run at a time), for up to 5 tests, until either: 1) 2consecutive tests fail, or 3 out of 5 tests fail, at which point
a pattern of toxicity will have been identified, or 2) 2 consecutive tests pass, or 3 out of 5 tests pass, in which case no pattern of toxicity is identified.
Preliminary Toxicity Investigation.
When a pattern of toxicity is detected the Permittee will notify the Director in writing within 5 days and begin an evaluation of the possible causes of the toxicity. The Permittee
will have 15 working days from demonstration of the pattern of toxicity to complete an optional Preliminary Toxicity Investigation (PTI) and submit a written report of the results to
the Director. The PTI may include, but is not limited to: additional chemical and biological monitoring, examination of Pretreatment Program records, examination of discharge monitoring
reports, a thorough review of the testing protocol, evaluation of treatment processes and chemical use, inspection of material storage and transfer areas to determine if any spill may
have occurred.If the PTI identifies a probable toxicant and/or a probable source of toxicity, the Permittee shall submit, as part of its final results, written notification of that effect
to the Director. Within thirty days of completing the PTI the Permittee shall submit to the Director for approval a control program to control effluent toxicity and shall proceed to
implement such plan in accordance with the Director’s approval. The control program, as submitted to or revised by the Director, will be incorporated into the permit. After final implementation,
the Permittee must demonstrate successful removal of toxicity by passing a two species WET test as outlined in this permit. With adequate justification, the Director may extend these
deadlines.If no probable explanation for toxicity is identified in the PTI, the Permittee shall notify the Director as part of its final report, along with a schedule for conducting
a Phase I Toxicity Reduction Evaluation (TRE) (see Part I, 4, f Toxicity Reduction Evaluation)If toxicity spontaneously disappears during the PTI, the Permittee shall submit written
notification to that effect to the Director, with supporting testing evidence.
Toxicity Reduction Evaluation (TRE). If a pattern of toxicity is detected the Permittee shall initiate a TIE/TRE within 7 days unless the Director has accepted the decision to complete
a PTI. With adequate justification, the Director may extend the 7-day deadline. The purpose of the TIE portion of a TRE will be to establish the cause of the toxicity, locate the source(s)
of the toxicity, and the TRE will control or provide treatment for the toxicity.
A TRE may include but is not limited to one, all, or a combination of the following:
Phase I – Toxicity Characterization
Phase II – Toxicity Identification Procedures
Phase III – Toxicity Control Procedures
Any other appropriate procedures for toxicity source elimination and control.
If the TRE establishes that the toxicity cannot be immediately eliminated, the Permittee shall submit a proposed compliance plan to the Director. The plan shall include the proposed
approach to control toxicity and a proposed compliance schedule for achieving control. If the approach and schedule are acceptable to the Director, this permit may be reopened and modified.If
toxicity spontaneously disappears during the TIE/TRE, the Permittee shall submit written notification to that effect to the Director.
If the TRE shows that the toxicity is caused by a toxicant(s) that may be controlled with specific numerical limitations, the Permitteeshall submit the following:
An alternative control program for compliance with the numerical requirements.
If necessary, as determined by the Director, provide a modified biomonitoring protocol which compensates for the pollutant(s) being controlled numerically.
This permit may be reopened and modified to incorporate any additional numerical limitations, a modified compliance schedule if judged necessary by the Director, and/or modified WET
testing requirements without public notice.
Failure to conduct an adequate TIE/TRE plan or program as described above, or the submittal of a plan or program judged inadequate by the Director, shall be considered a violation of
this permit. After implementation of TIE/TRE plan, the Permittee must demonstrate successful removal of toxicity by passing a two species WET test as outlined in this permit.
Reporting of Monitoring Results.
Reporting of Wastewater Monitoring ResultsMonitoring results obtained during the previous month shall be summarized for each month and reported byNetDMR, entered into NetDMR no later
than the 28th day of the month following the completed reporting period. The first report is due on April 28, 2024. If no discharge occurs during the reporting period, “no discharge”
shall be reported. Legible copies of these, and all other reports including whole effluent toxicity (WET) test reports required herein, shall be signed and certified in accordance with
the requirements of Signatory Requirements (see Part VII.G), and submitted by NetDMR, or to the Division of Water Quality at the following address:Department of Environmental QualityDivision
of Water QualityPO Box 144870Salt Lake City, Utah 84114-4870PRETREATMENT REQUIREMENTSDefinitions. For this section, the following definitions shall apply:Indirect Discharge means the
introduction of pollutants into a Publicly Owned Treatment Works (POTW) from any non-domestic source regulated under section 307 (b), (c) or (d) of the CWA. Interference means a discharge
which, alone or in conjunction with a discharge or discharges from other sources, both:Inhibits or disrupts the POTW, its treatment processes or operations, or its sludge processes,
use or disposal; andTherefore is a cause of a violation of any requirement of the POTW's NPDES permit (including an increase in the magnitude or duration of a violation) or of the prevention
of sewage sludge use or disposal in compliance with the following statutory provisions and regulations or permits issued thereunder (or more stringent State or local regulations): Section
405 of the Clean Water Act, the Solid Waste Disposal Act (SWDA) (including title II, more commonly referred to as the Resource Conservation and Recovery Act (RCRA), and including State
regulations contained in any State sludge management plan prepared pursuant to subtitle D of the SWDA), the Clean Air Act, the Toxic Substances Control Act, and the Marine Protection,
Research and Sanctuaries Act.Pass Through means a Discharge which exits the POTW into waters of the State or waters of the United States in quantities or concentrations which, alone
or in conjunction with a discharge or discharges from other sources, is a cause of a violation of any requirement of the POTW's NPDES permit (including an increase in the magnitude or
duration of a violation).Publicly Owned Treatment Works or POTW means a treatment works, as defined by section 212 of the CWA, which is owned by a State or municipality (as defined by
section 502(4) of the CWA). This definition includes any devices and systems used in the storage, treatment, recycling and reclamation of municipal sewage or industrial wastes of a liquid
nature. It also includes sewers, pipes and other conveyances only if they convey wastewater to a POTW Treatment Plant. The term also means the municipality, as defined in section 502(4)
of the CWA, which has jurisdiction over the Indirect Discharges to and the discharges from such a treatment works.Significant Industrial User (SIU) is defined as an Industrial User discharging
to a POTW that satisfies any of the following: Has a process wastewater flow of 25,000 gallons or more per average work day;Has a flow greater than five percent of the flow carried
by the municipal system receiving the waste; Is subject to Categorical Pretreatment Standards, or Has a reasonable potential for adversely affecting the operation of the POTW or violating
any pretreatment standard or requirement.User or Industrial User (IU) means a source of Indirect Discharge.Discharge to POTW. Any wastewaters discharged to the sanitary sewer, either
as a direct discharge or as a hauled waste, are subject to Federal, State and local pretreatment regulations. Pursuant to Section 307 of The Water Quality Act of 1987, the Permittee
shall comply with all applicable federal General Pretreatment Regulations promulgated at 40 CFR 403, the State Pretreatment Requirements at UAC R317-8-8, and any specific local discharge
limitations developed by the Publicly Owned Treatment Works (POTW) accepting the wastewaters. At a minimum, the discharge into a POTW must meet the requirements of Part II.D. and E.
of the permit.Hazardous Waste Notification. The Permittee must notify the POTW, the EPA Regional Waste Management Director, the Director and the State hazardous waste authorities in
writing if they discharge any substance into a POTW that, if otherwise disposed of, would be considered a hazardous waste under 40 CFR 261. This notification must include the name of
the hazardous waste, the EPA hazardous waste number, and the type of discharge (continuous or batch).General and Specific Prohibitions. General Prohibitions. The Permittee may not introduce
into a POTW any pollutant(s) which cause Pass Through or Interference. These general prohibitions and the specific prohibitions in paragraph 2. of this section apply to the introducing
pollutants into a POTW whether or not the Permittee is subject to other National Pretreatment Standards or any national, State, or local Pretreatment Requirements.Specific Prohibitions.
The following pollutants shall not be introduced into a POTW:Pollutants which create a fire or explosion hazard in the publicly owned treatment works (POTW), including, but not limited
to, wastestreams with a closed cup flashpoint of less than 140˚F (60˚C);Pollutants, which will cause corrosive structural damage to the POTW, but in no case, discharges with a pH lower
than 5.0;Solid or viscous pollutants in amounts which will cause obstruction to the flow in the POTW resulting in Interference;Any pollutant, including oxygen demanding pollutants (BOD,
etc.), released in a discharge at such volume or strength as to cause Interference in the POTW;Heat in amounts, which will inhibit biological activity in the POTW, resulting in Interference,
but in no case, heat in such quantities that the influent to the sewage treatment works exceeds 104˚F (40˚C)); Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil
origin in amounts that will cause Interference or Pass Through;Pollutants, which result in the presence of toxic gases, vapor, or fumes within the POTW in a quantity that may cause worker
health or safety problems;Any trucked or hauled pollutants, except at discharge points designated by the POTW; orAny pollutant that causes Pass Through or Interference at the POTW.Any
specific pollutant which exceeds any Local Limitation established by the POTW.Categorical Standards. In addition to the general and specific limitations expressed in Part II. D.of this
section, applicable National Categorical Pretreatment Standards must be met by all Industrial Users discharging into a POTW. These standards are published in the federal regulations
at 40 CFR 405 through 471.
BIOSOLIDS REQUIREMENTS
The State of Utah has adopted the 40 CFR 503 federal regulations for the disposal of sewage sludge (biosolids) by reference. However, this facility does not receive, generate, treat
or dispose of biosolids. Therefore 40 CFR 503 does not apply.
STORM WATER REQUIREMENTS.
Industrial Storm Water Permit. Based on the type of industrial activities occurring at the facility, the Permittee is required to maintain separate coverage or an appropriate exclusion
under the Multi-Sector General Permit (MSGP) for Storm Water Discharges Associated with Industrial Activities (UTR000000). If the facility is not already covered, the Permittee has 30
days from when this permit is issued to submit the appropriate Notice of Intent (NOI) for the MSGP or exclusion documentation.
MONITORING, RECORDING & GENERAL REPORTING REQUIREMENTS
Representative Sampling. Samples taken in compliance with the monitoring requirements established under Part I shall be collected from the effluent stream prior to discharge into the
receiving waters. Samples and measurements shall be representative of the volume and nature of the monitored discharge. Samples of biosolids shall be collected at a location representative
of the quality of biosolids immediately prior to the use-disposal practice.
Monitoring Procedures.Monitoring must be conducted according to test procedures approved under Utah Administrative Code ("UAC'') R317-2-10, UAC R317-8-4.1(10)(d), and/or 40 CFR 503 utilizing
sufficiently sensitive test methods unless other test procedures have been specified in this permit. Monitoring must be conducted according to the test procedures listed above unless
another method is required under 40 CFR subchapters N or O. Sufficiently sensitive test method means: (1) The method minimum level (ML) is at or below the level of the effluent limit
established in the permit for the measured pollutant or pollutant parameter; or (2) The method has the lowest ML of the analytical methods approved under 40 CFR part 136 or required
under 40 CFR chapter I, subchapter N or O for the measured pollutant or pollutant parameter as per40 CFR 122.44(i)(1)(iv)(A).
Penalties for Tampering. The Act provides that any person who falsifies, tampers with, or knowingly renders inaccurate, any monitoring device or method required to be maintained under
this permit shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than six months per violation, or by both.
Compliance Schedules. Reports of compliance or noncompliance with, or any progress reports on, interim and final requirements contained in any Compliance Schedule of this permit shall
be submitted no later than 14 days following each schedule date.
Additional Monitoring by the Permittee. If the Permittee monitors any parameter more frequently than required by this permit, using test procedures approved under Permit Part V.B.,
the results of this monitoring shall be included in the calculation and reporting of the data submitted in the DMR or the Biosolids Report Form.
Records Contents. Records of monitoring information shall include:
The date, exact place, and time of sampling or measurements:
The individual(s) who performed the sampling or measurements;
The date(s) and time(s) analyses were performed;
The individual(s) who performed the analyses;
The analytical techniques or methods used; and,
The results of such analyses.
Retention of Records. The Permittee shall retain records of all monitoring information, including all calibration and maintenance records and all original strip chart recordings for
continuous monitoring instrumentation, copies of all reports required by this permit, and records of all data used to complete the application for this permit, for a period of at least
five years from the date of the sample, measurement, report or application. This period may be extended by request of the Director at any time. A copy of this UPDES permit must be maintained
on site during the duration of activity at the permitted location
Twenty-four Hour Notice of Noncompliance Reporting.
The Permittee shall (orally) report any noncompliance including transportation accidents, spills, and uncontrolled runoff from biosolids transfer or land application sites which may
seriously endanger health or environment, as soon as possible, but no later than twenty-four (24) hours from the time the Permittee first became aware of circumstances. The report shall
be made to the Division of Water Quality (DWQ) via the 24-hour answering service (801) 536-4123.
The following occurrences of noncompliance shall initially be reported by telephone to the DWQ via the 24-hour answering service as soon as possible but no later than 24 hours from the
time the Permittee becomes aware of the circumstances:
Any noncompliance which may endanger health or the environment;
Any unanticipated bypass, which exceeds any effluent limitation in the permit (See Part VI.G, Bypass of Treatment Facilities.);
Any upset which exceeds any effluent limitation in the permit (See Part VI.H, Upset Conditions.);
Violation of a daily discharge limitation for any of the pollutants listed in the permit. For other permit violations which will not endanger health or the environment, DWQ may otherwise
be notified during business hours (801) 536-4300; or,
Violation of any of the Table 3 metals limits, the pathogen limits, the vector attraction reduction limits or the management practices for biosolids that have been sold or given away.
A written submission shall also be provided within five days of the time that the Permittee becomes aware of the circumstances. The written submission shall contain:
A description of the noncompliance and its cause;
The period of noncompliance, including exact dates and times;
The estimated time noncompliance is expected to continue if it has not been corrected;
Steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance; and,
Steps taken, if any, to mitigate the adverse impacts on the environment and human health during the noncompliance period.
The Director may waive the written report on a case-by-case basis if the oral report has been received within 24 hours by the Division of Water Quality, (801) 536-4300.
Reports shall be submitted to the addresses in Part I.D, Reporting of Monitoring Results.
Other Noncompliance Reporting. Instances of noncompliance not required to be reported within 24 hours shall be reported at the time that monitoring reports for Part I.D are submitted.
The reports shall contain the information listed in Part V.H.3
Inspection and Entry The Permittee shall allow the Director, or an authorized representative, upon the presentation of credentials and other documents as may be required by law, to:
Enter upon the Permittee's premises where a regulated facility or activity is located or conducted, or where records must be kept under the conditions of the permit;
Have access to and copy, at reasonable times, any records that must be kept under the conditions of this permit;
Inspect at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this permit, including but not
limited to, biosolids treatment, collection, storage facilities or area, transport vehicles and containers, and land application sites;
Sample or monitor at reasonable times, for the purpose of assuring permit compliance or as otherwise authorized by the Act, any substances or parameters at any location, including, but
not limited to, digested biosolids before dewatering, dewatered biosolids, biosolids transfer or staging areas, any ground or surface waters at the land application sites or biosolids,
soils, or vegetation on the land application sites; and,
The Permittee shall make the necessary arrangements with the landowner or leaseholder to obtain permission or clearance, the Director, or authorized representative, upon the presentation
of credentials and other documents as may be required by law, will be permitted to enter without delay for the purposes of performing their responsibilities.
COMPLIANCE RESPONSIBILITIES
Duty to Comply. The Permittee must comply with all conditions of this permit. Any permit noncompliance constitutes a violation of the Act and is grounds for enforcement action; for
permit termination, revocation and reissuance, or modification; or for denial of a permit renewal application. The Permittee shall give advance notice to the Director of any planned
changes in the permitted facility or activity, which may result in noncompliance with permit requirements.
Penalties for Violations of Permit Conditions. The Act provides that any person who violates a permit condition implementing provisions of the Act is subject to a civil penalty not
to exceed $10,000 per day of such violation. Any person who willfully or negligently violates permit conditions or the Act is subject to a fine not exceeding $25,000 per day of violation.
Except as provided at Part VI.G, Bypass of Treatment Facilities and Part VI.H, Upset Conditions, nothing in this permit shall be construed to relieve the Permittee of the civil or criminal
penalties for noncompliance.
Need to Halt or Reduce Activity not a Defense. It shall not be a defense for a Permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity
in order to maintain compliance with the conditions of this permit.
Duty to Mitigate. The Permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this permit, which has a reasonable likelihood of adversely affecting
human health or the environment. The Permittee shall also take all reasonable steps to minimize or prevent any land application in violation of this permit.
Proper Operation and Maintenance. The Permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which
are installed or used by the Permittee to achieve compliance with the conditions of this permit. Proper operation and maintenance also includes adequate laboratory controls and quality
assurance procedures. This provision requires the operation of back-up or auxiliary facilities or similar systems, which are installed by a Permittee only when the operation is necessary
to achieve compliance with the conditions of the permit.
Removed Substances. Collected screening, grit, solids, sludge, or other pollutants removed in the course of treatment shall be disposed of in such a manner so as to prevent any pollutant
from entering any waters of the state or creating a health hazard. Sludge/digester supernatant and filter backwash shall not directly enter either the final effluent or waters of the
state by any other direct route.
Bypass of Treatment Facilities.
Bypass Not Exceeding Limitations. The Permittee may allow any bypass to occur which does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance
to assure efficient operation. These bypasses are not subject to paragraph 2and 3 of this section.
Prohibition of Bypass.
Bypass is prohibited, and the Director may take enforcement action against a Permittee for bypass, unless:
Bypass was unavoidable to prevent loss of human life, personal injury, or severe property damage;
There were no feasible alternatives to bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes, or maintenance during normal periods of equipment downtime.
This condition is not satisfied if adequate backup equipment should have been installed in the exercise of reasonable engineering judgement to prevent a bypass which occurred during
normal periods of equipment downtime or preventive maintenance, and
The Permittee submitted notices as required under Part VI.G.3.
The Director may approve an anticipated bypass, after considering its adverse effects, if the Director determines that it will meet the three conditions listed in Parts VI.G.2.a (1),
(2) and (3).
Notice.
Anticipated bypass. Except as provided above in Part VI.G.2 and below in Part VI.G.3.b, if the Permittee knows in advance of the need for a bypass, it shall submit prior notice, at
least ninety days before the date of bypass. The prior notice shall include the following unless otherwise waived by the Director:
Evaluation of alternative to bypass, including cost-benefit analysis containing an assessment of anticipated resource damages:
A specific bypass plan describing the work to be performed including scheduled dates and times. The Permittee must notify the Director in advance of any changes to the bypass schedule;
Description of specific measures to be taken to minimize environmental and public health impacts;
A notification plan sufficient to alert all downstream users, the public and others reasonably expected to be impacted by the bypass;
A water quality assessment plan to include sufficient monitoring of the receiving water before, during and following the bypass to enable evaluation of public health risks and environmental
impacts; and,
Any additional information requested by the Director.
Emergency Bypass. Where ninety days advance notice is not possible, the Permittee must notify the Director, and the Director of the Department of Natural Resources, as soon as it becomes
aware of the need to bypass and provide to the Director the information in Part VI.G.3.a.(1) through (6) to the extent practicable.
Unanticipated bypass. The Permittee shall submit notice of an unanticipated bypass to the Director as required under Part IV.H, Twenty-Four Hour Reporting. The Permittee shall also
immediately notify the Director of the Department of Natural Resources, the public and downstream users and shall implement measures to minimize impacts to public health and environment
to the extent practicable.
Upset Conditions.
Effect of an upset. An upset constitutes an affirmative defense to an action brought for noncompliance with technology-based permit effluent limitations if the requirements of paragraph
2 of this section are met. Director's administrative determination regarding a claim of upset cannot be judiciously challenged by the Permittee until such time as an action is initiated
for noncompliance.
Conditions necessary for a demonstration of upset. A Permittee who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating
logs, or other relevant evidence that:
An upset occurred and that the Permittee can identify the cause(s) of the upset;
The permitted facility was at the time being properly operated;
The Permittee submitted notice of the upset as required under Part V.H, Twenty-four Hour Notice of Noncompliance Reporting; and,
The Permittee complied with any remedial measures required under Part VI.D, Duty to Mitigate.
Burden of proof. In any enforcement proceeding, the Permittee seeking to establish the occurrence of an upset has the burden of proof.
GENERAL REQUIREMENTS
Planned Changes. The Permittee shall give notice to the Director as soon as possible of any planned physical alterations or additions to the permitted facility. Notice is required
only when:
The alteration or addition to a permitted facility may meet one of the criteria for determining whether a facility is a new source in 122.29(b); or
The alteration or addition could significantly change the nature or increase the quantity of pollutants discharged. This notification applies to pollutants which are subject neither
to effluent limitations in the permit nor to notification requirements under Subsection R317-8-4.1(15).
The alteration or addition results in a significant change in the Permittee's sludge use or disposal practices, and such alteration, addition, or change may justify the application of
permit conditions that are different from or absent in the existing permit, including notification of additional use or disposal sites not reported during the permit application process
or not reported pursuant to an approved land application plan.The Permittee shall give notice to the Director of any planned changes at least 30 days prior to their implementation.
Anticipated Noncompliance. The Permittee shall give advance notice to the Director of any planned changes in the permitted facility or activity, which may result in noncompliance with
permit requirements.
Permit Actions. This permit may be modified, revoked and reissued, or terminated for cause. The filing of a request by the Permittee for a permit modification, revocation and reissuance,
or termination, or a notification of planned changes or anticipated noncompliance, does not stay any permit condition.
Duty to Reapply. If the Permittee wishes to continue an activity regulated by this permit after the expiration date of this permit, the Permittee shall apply for and obtain a new permit.
The application shall be submitted at least 180 days before the expiration date of this permit.
Duty to Provide Information. The Permittee shall furnish to the Director, within a reasonable time, any information which the Director may request to determine whether cause exists
for modifying, revoking and reissuing, or terminating this permit, or to determine compliance with this permit. The Permittee shall also furnish to the Director, upon request, copies
of records required to be kept by this permit.
Other Information. When the Permittee becomes aware that it failed to submit any relevant facts in a permit application, or submitted incorrect information in a permit application or
any report to the Director, it shall promptly submit such facts or information.
Signatory Requirements. All applications, reports or information submitted to the Director shall be signed and certified.
All permit applications shall be signed by either a principal executive officer or ranking elected official. A person is a duly authorized representative only if:
The authorization is made in writing by a person described above and submitted to the Director, and,
The authorization specifies either an individual or a position having responsibility for the overall operation of the regulated facility, such as the position of plant manager, superintendent,
position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters. A duly authorized representative may thus be either a named
individual or any individual occupying a named position.
For a corporation. By a responsible corporate officer. For the purpose of this section, a responsible corporate officer means:
A president, secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who perfoms similar policy- or decision-making
functions for the corporation, or
the manager of one or more manufacturing, production, or operating facilities, provided, the manager is authorized to make management decisions which govern the operation of the regulated
facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long term
environmental compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information
for permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures.
For a partnership or sole proprietorship. By a general partner or the proprietor, respectively; or
For a municipality, State, Federal, or other public agency. By either a principal executive officer or ranking elected official. For purposes of this section, a principal executive
officer of a Federal agency includes:
The chief executive officer of the agency, or
a senior executive officer having responsibility for the overall operations of a principal geographic unit of the agency (e.g., Regional Administrators of EPA).
All reports required by the permit and other information requested by the Director shall be signed by a person described above or by a duly authorized representative of that person.
Changes to authorization. If an authorization under paragraph VII.G.2 is no longer accurate because a different individual or position has responsibility for the overall operation of
the facility, a new authorization satisfying the requirements of paragraph VII.G.2. must be submitted to the Director prior to or together with any reports, information, or applications
to be signed by an authorized representative.
Certification. Any person signing a document under this section shall make the following certification:
"I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel
properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information,
the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information,
including the possibility of fine and imprisonment for knowing violations."
Penalties for Falsification of Reports. The Act provides that any person who knowingly makes any false statement, representation, or certification in any record or other document submitted
or required to be maintained under this permit, including monitoring reports or reports of compliance or noncompliance shall, upon conviction be punished by a fine of not more than $10,000.00
per violation, or by imprisonment for not more than six months per violation, or by both.
Availability of Reports. Except for data determined to be confidential under UAC R317-8-3.2, all reports prepared in accordance with the terms of this permit shall be available for
public inspection at the office of Director. As required by the Act, permit applications, permits and effluent data shall not be considered confidential.
Oil and Hazardous Substance Liability. Nothing in this permit shall be construed to preclude the Permittee of any legal action or relieve the Permittee from any responsibilities, liabilities,
or penalties to which the Permittee is or may be subject under the Act.
Property Rights. The issuance of this permit does not convey any property rights of any sort, or any exclusive privileges, nor does it authorize any injury to private property or any
invasion of personal rights, nor any infringement of federal, state or local laws or regulations.
Severability. The provisions of this permit are severable, and if any provisions of this permit, or the application of any provision of this permit to any circumstance, is held invalid,
the application of such provision to other circumstances, and the remainder of this permit, shall not be affected thereby.
Transfers. This permit may be automatically transferred to a new Permittee if:
The current Permittee notifies the Director at least 20 days in advance of the proposed transfer date;
The notice includes a written agreement between the existing and new Permittee’s containing a specific date for transfer of permit responsibility, coverage, and liability between them;
and,
The Director does not notify the existing Permittee and the proposed new Permittee of his or her intent to modify, or revoke and reissue the permit. If this notice is not received,
the transfer is effective on the date specified in the agreement mentioned in paragraph 2 above.
State or Federal Laws. Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the Permittee from any responsibilities, liabilities, or
penalties established pursuant to any applicable state law or regulation under authority preserved by Sections19-5-117 and 510 of the Act or any applicable Federal or State transportation
regulations, such as but not limited to the Department of Transportation regulations.
Water Quality - Reopener Provision. This permit may be reopened and modified (following proper administrative procedures) to include the appropriate effluent limitations and compliance
schedule, if necessary, if one or more of the following events occurs:
Water Quality Standards for the receiving water(s) to which the Permittee discharges are modified in such a manner as to require different effluent limits than contained in this permit.
A final wasteload allocation is developed and approved by the State and/or EPA for incorporation in this permit.
Revisions to the current CWA § 208 areawide treatment management plans or promulgations/revisions to TMDLs (40 CFR 130.7) approved by the EPA and adopted by DWQ which calls for different
effluent limitations than contained in this permit.
Biosolids – Reopener Provision. This permit may be reopened and modified (following proper administrative procedures) to include the appropriate biosolids limitations (and compliance
schedule, if necessary), management practices, other appropriate requirements to protect public health and the environment, or if there have been substantial changes (or such changes
are planned) in biosolids use or disposal practices; applicable management practices or numerical limitations for pollutants in biosolids have been promulgated which are more stringent
than the requirements in this permit; and/or it has been determined that the Permittees biosolids use or land application practices do not comply with existing applicable state of federal
regulations.
Toxicity Limitation - Reopener Provision:This permit may be reopened and modified (following proper administrative procedures) to include, whole effluent toxicity (WET) limitations,
a compliance date, a compliance schedule, a change in the whole effluent toxicity (biomonitoring) protocol, additional or modified numerical limitations, or any other conditions related
to the control of toxicants if one or more of the following events occur;
Toxicity is detected, as per Part I.C.4.a or b of this permit, during the duration of this permit.
The TRE results indicate that the toxicant(s) represent pollutant(s) or pollutant parameter(s) that may be controlled with specific numerical limits, and the Director concludes that
numerical controls are appropriate.
Following the implementation of numerical control(s) of toxicant(s), the Director agrees that a modified biomonitoring protocol is necessary to compensate for those toxicants that are
controlled numerically.
The TRE reveals other unique conditions or characteristics, which in the opinion of the permit issuing authority justify the incorporation of unanticipated special conditions in the
permit.
DEFINITIONSWastewater.
The “7-day (and weekly) average”, other than for E. coli bacteria, fecal coliform bacteria, and total coliform bacteria, is the arithmetic average of all samples collected during a consecutive
7-day period or calendar week, whichever is applicable. Geometric means shall be calculated for E. coli bacteria, fecal coliform bacteria, and total coliform bacteria. The 7-day and
weekly averages are applicable only to those effluent characteristics for which there are 7-day average effluent limitations. The calendar week, which begins on Sunday and ends on Saturday,
shall be used for purposes of reporting self-monitoring data on discharge monitoring report forms. Weekly averages shall be calculated for all calendar weeks with Saturdays in the month.
If a calendar week overlaps two months (i.e., the Sunday is in one month and the Saturday in the following month), the weekly average calculated for that calendar week shall be included
in the data for the month that contains Saturday.
The "30-day (and monthly) average," other than for E. coli bacteria, fecal coliform bacteria and total coliform bacteria, is the arithmetic average of all samples collected during a
consecutive 30-day period or calendar month, whichever is applicable. Geometric means shall be calculated for E. coli bacteria, fecal coliform bacteria and total coliform bacteria.
The calendar month shall be used for purposes of reporting self-monitoring data on discharge monitoring report forms.
“Act,” means the Utah Water Quality Act.
“Acute toxicity” occurs when 50 percent or more mortality is observed for either test species at any effluent concentration (lethal concentration or “LC50”).
"Annual Loading Cap" is the highest allowable phosphorus loading discharged over a calendar year, calculated as the sum of all the monthly loading discharges measured during a calendar
year divided by the number of monthly discharges measured during that year.
“Bypass,” means the diversion of waste streams from any portion of a treatment facility.
“Chronic toxicity” occurs when the IC25< XX% effluent. The XX% effluent is the concentration of the effluent in the receiving water, at the end of the mixing zone expressed as per cent
effluent.
"IC25" is the concentration of toxicant (given in % effluent) that would cause a 25% reduction in mean young per female, or a 25% reduction in overall growth for the test population.
“Composite Samples” shall be flow proportioned. The composite sample shall, as a minimum, contain at least four (4) samples collected over the compositing period. Unless otherwise
specified, the time between the collection of the first sample and the last sample shall not be less than six (6) hours nor more than 24 hours. Acceptable methods for preparation of
composite samples are as follows:
Constant time interval between samples, sample volume proportional to flow rate at time of sampling;
Constant time interval between samples, sample volume proportional to total flow (volume) since last sample. For the first sample, the flow rate at the time the sample was collected
may be used;
Constant sample volume, time interval between samples proportional to flow (i.e., sample taken every “X” gallons of flow); and,
Continuous sample volume, with sample collection rate proportional to flow rate.
“CWA”means The Federal Water Pollution Control Act, as amended, by The Clean Water Act of 1987.
“Daily Maximum” (Daily Max.) is the maximum value allowable in any single sample or instantaneous measurement.
“EPA,” means the United States Environmental Protection Agency.
“Director,” means Director of the Division of Water Quality.
A “grab” sample, for monitoring requirements, is defined as a single “dip and take” sample collected at a representative point in the discharge stream.
An “instantaneous” measurement, for monitoring requirements, is defined as a single reading, observation, or measurement.
“Severe Property Damage,” means substantial physical damage to property, damage to the treatment facilities which causes them to become inoperable, or substantial and permanent loss
of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production.
“Upset,” means an exceptional incident in which there is unintentional and temporary noncompliance with technology-based permit effluent limitations because of factors beyond the reasonable
control of the Permittee. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities,
lack of preventative maintenance, or careless or improper operation.