Loading...
HomeMy WebLinkAboutDSHW-2024-0093421 Division of Waste Management and Radiation Control Solid Waste Management Program Mailing Address Office Location Phone (801) 536-0200 P.O. Box 144880 195 North 1950 West Fax (801) 536-0222 Salt Lake City, Utah 84114-488 Salt Lake City, Utah 84116 www.deq.utah.gov APPLICATION FOR A TEMPORARY PERMIT TO OPERATE AN EXPLORATION AND PRODUCTION WASTE FACILITY In 2019, the Utah Legislature made changes to the Solid and Hazardous Waste Act, Utah Code § 19-6- 101 et seq.,which required jurisdiction over the disposal of Oil and Gas Exploration and Production Waste move from the Department of Natural Resources’ Division of Oil, Gas, and Mining (DOGM) to the Department of Environmental Quality’s Division of Waste Management and Radiation Control (DWMRC). In preparation for this regulatory shift, DWMRC has proposed a temporary permitting mechanism for existing Exploration and Production (E&P)facilities as defined in the proposed Utah Admin. Code R315- 301-2(22)(a). The proposed rules state that the Director of DWMRC may issue a temporary permit for the purposes of facilitating the owner’s or operator’s good faith transition from regulation under Utah Admin. Code R649-9 to regulation under Utah Admin. Code R315-321 or R315-322. Applications for temporary permits must be received by the Director of DWMRC no less than 30 days before October 1, 2024. The temporary permits will expire one year from the effective date, which is the date the financial assurance mechanism held by DOGM is transferred to DWMRC. To complete a temporary permit application to operate an E&P facility, an owner or operator of an existing E&P facility must: 1.Register the company in DWMRC’s Community Portal and complete facility information within the Community Portal. 2.Complete the attached Exploration and Production Waste Facility Temporary Permit Application Form. 3.Provide DWMRC with the following required documentation, to the extent it has not already been provided to DWMRC or is not already in DWMRC’s possession: a.Facility map with each landfarm cell, landfill cell, and surface impoundment labeled; b.Copy of Division of Oil, Gas, and Mining Permit; c.Copy of Division of Oil, Gas, and Mining Permit Approval/Issuance Letter; and d.Copy of Division of Oil, Gas, and Mining Bonding (financial assurance). 4.Submit the Application Form and required documentation to DWMRC through the Community Portal Miscellaneous Document Submission. 5.Within 120 days of DWMRC’s issuance of a temporary permit, the financial assurance mechanism held by DOGM must be transferred to DWMRC.If the Director issues a temporary permit, it shall not become effective until the financial assurance mechanism held by DOGM is transferred to DWMRC. An effective temporary permit is required to operate an E&P Facility under DWMRC’s jurisdiction. 2 Exploration and Production Waste Facility Temporary Permit Application Form I.Facility Name and Location Name of Facility Central Facility -Sigurd Facility Address (Street or Directions to Facility) 2080 Ut-24 County Sevier City. Sigurd, UT Zip Code 84657 Telephone 435-896-2956 Township 23S Range 1W Section 7 Quarter Section SE Quarter/Quarter Section SE Main Gate Latitude:38.810393 Longitude:-111.940573 II.Existing E&P Facilities ☐Open Landfarm Cell(s) ☐X Evaporation Pond(s) Number of Open Landfarm Cells:0 Number of Evaporation Ponds:1 III.Facilities to be Permitted by DWMRC ☐Landfill Cell(s) ☐X Surface Impoundment(s) Number of Landfill Cells:0 Number of Surface Impoundments:1 III.Facility Owner(s) Information Legal Name of Facility Owner Wolverine Gas and Oil Company of Utah, LLC Mailing Address 55 Campau NW City Grand Rapids State MI Zip Code 49503 Telephone 616-458-1150 IV.Facility Operator(s) Information Legal Name of Facility Operator Wolverine Gas and Oil Company of Utah, LLC Mailing Address 2080 South Hwy 24 City Sigurd State UT Zip Code 84657 Telephone 435-896-1943 V.Property Owner(s) Information Is the property leased?NO Name of Property Owner Wolverine Gas and Oil Corporation Mailing Address 55 Campau NW City Grand Rapids State MI Zip Code 49503 Telephone 616-458-1150 VI.Designated Contact Information 3 Facility Owner Designated Contact (if different than above) Jordan Ritsema Title Production Engineer Mailing Address City.State Zip Code Telephone 616-929-1933 Email Address jritsema@wgo.us Alternative Telephone (cell phone or other) 616-915-0812 Facility Operator Designated Contact (if different than above) Tony Cook Title Superintendent Mailing Address City State Zip Code Telephone 435-896-2956 Email Address tcook@wgo.us Alternative Telephone (cell phone or other) 435-201-1622 Property Owner Contact (if different than above)Title Mailing Address City State Zip Code Telephone Email Address Alternative Telephone (cell phone or other) VII.Waste Types to be Disposed of (check all that apply)VIII.Facility Area x Exploration and Production wastes that are exempt from hazardous waste rules (R315-260-4(b)(5)). ☐Very Small Quantity Generator hazardous waste Facility Area:8 acres Disposal Area:4 acres IX.Application Documents Indicate documents attached to this application (all are required): X Facility Map with each landfarm cell, landfill cell, and surface impoundment labeled X Copy of Division of Oil, Gas, and Mining Permit X Copy of Division of Oil, Gas, and Mining Approval/Issuance Letter X Copy of Division of Oil, Gas, and Mining Bonding (Financial Assurance) State of Utah DEPARTMENT OF NATURAL RESOURCES GARY R. HERBERT Governor SPENCER J. COX Lieutenant Governor MICHAEL R. STYLER Executive Director Division of Oil, Gas and Mining JOHN R. BAZA Division Director Permit to Operate ******************** Facility Name: Central Facility - Sigurd Facility Type: Commercial Waste Disposal Facility Location: Section 7, Township 23S, Range 1W County: Sevier Approval Date: December 31, 2018 1. Issued to: Wolverine Gas & Oil Company of Utah, LLC 2. Authority: Pursuant to Utah Code Ann. §§ 40-6-1 et seq., and Utah Admin. Code §§ R649-9 et seq., the Utah Division of Oil, Gas and Mining (“Division”) issues this Permit to operate an E and P waste disposal facility. 3. Duration: This Permit shall expire five years from the Approval Date. The Division may revoke, suspend, or impose additional operating conditions or limitations on a disposal facility permit at any time, for good cause, after notice to the operator. The Division may suspend a waste disposal permit or impose additional conditions or limitations in an emergency to forestall an imminent threat to fresh water, public health, or safety of the environment. Suspension of a disposal facility permit may be for a fixed period of time or until the operator remedies the violation or potential violation. If the Division suspends a disposal facility permit, the disposal facility shall not accept E and P waste during the suspension period. 4. General: 4.1 Effect on Prior Permits. This Permit supersedes any existing E and P waste disposal permit previously obtained for the Facility and provides the terms that govern operations at this Facility. 4.2 Incorporation of Application. The Division issues this Permit in response to Wolverine’s “Permit Renewal Application” dated 6/18/2018 and received by the Division on 6/18/2018, (“Application”). The Facility shall operate in accordance with the best management practices described in the Application. 4.3 Compliance with Applicable Laws. The Facility shall comply with Utah Code Ann. §§ 40-6- 1 et seq. and Utah Administrative Code §§ R649-9 et seq.. 5. Reporting and Recordkeeping Requirements: 1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801 telephone (801) 538-5340 • facsimile (801) 359-3940 • TTY (801) 538-7458 • www.ogm.utah.gov Sundry Number: 88690 RECEIVED: Jun. 18, 2018 The Facility shall comply with the reporting and recordkeeping requirements in Utah Admin. Code § R649-9-11. 6. Modifications: This Permit only applies to the Facility as it is described in the Application. Any additions to the Facility or modifications of the waste treatment processes described in the Application are not allowed and require a permit modification. 7. Enforcement: The issuance of this permit does not supersede local ordinances, county planning and zoning requirements, or other permits required to conduct business at the Facility. A copy of this approval should be kept at the Central Facility - Sigurd field office, and field personnel shall be aware of the Conditions of Approval. 8. Approval: Therefore, having met all the technical permit requirements of Utah Admin. Code §§ R649-9 et seq., final approval to operate the Facility in accordance with this Permit is hereby granted. 9. Contact Information: The following are Division of Oil, Gas and Mining contacts and their telephone numbers: Dayne Doucet, Permit Manager: 801-538-5303 Bart Kettle, Operations Manager: 435-820-0862 Ammon McDonald, Environmental Scientist: 801-538-5337 Approved By: ________________________ By: Dayne Doucet Title: Permit Manager Sundry Number: 88690 RECEIVED: Jun. 18, 2018 Conditions of Approval: 1. Evaporation Facilities 1.1 A minimum of 2 feet of freeboard shall be maintained in the pit(s) at all times, and that a method of obviously displaying the freeboard shall be devised and implemented. Utah Admin. Code § R649-9-4.6.4. 1.2 Pit(s) are to be maintained such that hydrocarbons will not collect on the surface. Hydrocarbon accumulations, other than de minimis quantities, shall be removed within 24 hours. Utah Admin. Code § R649-9-4.6.4. 1.3 Spraying water to accelerate evaporation should be closely monitored. Overspray outside the lined pit area is considered a violation. Utah Admin. Code § R649-9-4.9.2. 1.4 The leak detection system must be checked weekly. Any leak must be reported to the Division immediately, and corrective measures must be taken as directed by the Division. 1.5 The compacted secondary containment berms at the Facility shall be inspected quarterly and after a major rainstorm or windstorm to ensure integrity Utah Admin. Code § R649-9-11.3.2. 1.6 Evaporation ponds are permitted to accept produced water. 2. Landfarms 2.1 E and P waste accepted by the landfarm shall be sufficiently free of liquid content to pass a 60-mesh liquid paint filter test (i.e., no produced water or drilling mud). 2.2 Pooling of liquids in the landfarm is prohibited. 2.3 Within 72 hours after receipt of E and P waste, the operator shall prepare materials for remediation. 2.4 Soils shall be turned regularly, a minimum of once a month. 2.5 Additional materials shall not be added until the soil concentrations of the current lift meet the Division’s salinity and hydrocarbon cleanup standards. FAILURE TO COMPLY WITH THE ABOVE LISTED CONDITIONS OF APPROVAL MAY RESULT IN CLOSURE OF THE FACILITY. Sundry Number: 88690 RECEIVED: Jun. 18, 2018 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312 RECEIVED: Nov. 27, 2023 Sundry Number: 127191 Facility Number: 312