HomeMy WebLinkAboutDRC-2022-021135 - 0901a068810e9945
DRC-2022-021135
Mailing Address: P.O. Box 144880 • Salt Lake City, UT 84114-4880
Telephone (801) 536-0200 • Fax (801) 536-0222 • T.D.D. (801) 536-4284
www.deq.utah.gov
Printed on 100% recycled paper
State of Utah
SPENCER J. COX
Governor
DEIDRE HENDERSON
Lieutenant Governor
Department of
Environmental Quality
Kimberly D. Shelley
Executive Director
DIVISION OF WASTE MANAGEMENT
AND RADIATION CONTROL
Douglas J. Hansen
Director
September 20, 2022
Vern C. Rogers, Director of Regulatory Affairs
EnergySolutions, LLC
299 South Main Street, Suite 1700
Salt Lake City, UT 84111
RE: Federal Cell Facility Application Requests for Information
Dear Mr. Rogers:
The Division of Waste Management and Radiation Control (Division) hereby provides initial Requests for
Information (RFI) regarding the Federal Cell Facility Application dated August 4, 2022. Each individual
paragraph in the attached document is numbered and represents an issue discovered in a review of the
application.
When responding to an RFI, please use the assigned number representing the question. The Division will
track all responses and provide regular updated information to the public and reviewers.
The current review does not represent a comprehensive evaluation of the Application’s merit and additional
RFI’s will follow where appropriate.
If you have any questions regarding this letter, please call Otis Willoughby at (801) 536-0220.
Sincerely,
Douglas J. Hansen, Director
Division of Waste Management and Radiation Control
DJH/OHW/kd
Enclosure: Federal Cell Application Review –
Request for Information or Updates to the Application (RFI) (DRC-2022-021115)
c: Jeff Coombs, EHS, Health Officer, Tooele County Health Department
Bryan Slade, Environmental Health Director, Tooele County Health Department
EnergySolutions General Correspondence Email
LLRW General Correspondence Email
1
Federal Cell Application Review
Request for Information or Updates to the Application (RFI)
General
• Each of the RFI’s has been assigned an identifier with a numbering convention as
follows-
o Application/Appendix Section
▪ Section/Appendix Subsection
• Section/Appendix Subsubsection (when applicable)
o Sequential numbering
Example: A question in Section 1, subsection 1, subsubsection 1 -The first RFI # would
be 1.1.1-1, the next question in that section/subsection would be numbered 1.1.1-2
Please refer to the assigned RFI number when submitting a response.
• Redacted Information- The phrase “REDACTIED INFORMATION” is misspelled
throughout the Application.
• Documents Still Under Review- Several documents listed throughout the application and
appendices are still under review by the Division, including (i) the Basal Aquifer Study,
and (ii) the Cover Test Cell Study. The Division has not yet approved all the study
content. Please update the references to indicate their status, using appropriate notation
(e.g., “under review by the Division”).
Section 1: General Information
• 1.2.2-1
On Page 1-11, the link “General Industrial District M-G type uses” is expired and
gives a 403 Forbidden message Error.
Section 2: Site Characteristics
• 2.1.2-1
On Page 2-5, the “Census 2020” link sends the user an authentication message from a
company that indicates that it will collect information on the user. Please fix the link
so a user does not have to agree to unexpected privacy-release requirements.
• 2.2.-1
On Page 2-8, in the last paragraph of Section 2.2 entitled “Meteorology and
Climatology”, it states, "an independent firm evaluated on-site meteorological data
collected from June 1993 to December 2020." However, EnergySolutions does not
provide a citation for this claim.
2
• 2.3.1-1
On Page 2-8, the “Hintze, 1980” link sends the user to a publication webpage, but
access is not granted to allow the user to view the materials. Also, the publication
associated with the link is Bisdorf and Zohdy (1980), not Hintze (1980).
• 2.4.1-1
On Page 2-19, it says, “A Probable Maximum Precipitation and Probable Maximum
Flood have been considered for the Clive Facilities (Appendix Y).” However,
searches for each of the terms probable, maximum, precipitation, flood, PMP, and
PMF in Appendix Y turned up zero results
• 2.10-1
The following are discrepancies for citations referenced in this section and the
associated electronic link to a file:
Page Citation Reference in Section Electronic Ref
2-9 Moore and Sorensen 1979 Present Missing
2-29, 2-51 Neptune 2021 Present Missing
2-29 DOE 1984 and 1989 1989 Ref Missing 1989 Ref
Missing
2-31 Ryan and Elimelech 1996 Missing Missing
2-35 DWR 2014 Missing Missing
2-36 Envirocare 2004 Missing Missing
2-48 Cronquist et al. 1972 Present Missing
2-49 NRC 1980 Missing Missing
2-58 Missing Utah 2014 Utah 2014
• 2.10.1-2
On Page 2-55, the link “General Industrial District M-G type uses” is expired and
gives a 403 Forbidden message Error.
Section 3: Design and Construction
• 3.1-1
On Page 3-4, the “Table 3-1: Conditions [^1]” bracketed citation link sends users to
Microsoft word and gives an error message.
• 3.1-2
On Page 3-10, a typo appears in the hyperlink with the bracketed 1 “[1]”, this
typo breaks the hyperlink.
3
• 3.1.1-1
On Page 3-12, the Application says, “In addition, Appendix Y, HAL PMF Tech
Memo, Figure 2 depicts the flow path of the modeled Probable Maximum Flood
draining to the southwest of the Clive Facility.” However, the memo does not appear
to be in Appendix Y.
• 3.2-1
On Page 3-22, the Application addresses the cover as a principal design feature, and
states that, efforts to “encourage runoff” on the cover design slope, velocities must
still be limited, and indicates use of the following as bounding values:
Maximum theoretical velocities from Appendices M and O
Maximum drainage velocities during PMP:
from Appendices M and O
However, a review of Appendix M indicates that the text and tables of Appendix M
pertain only to ditch calculations, not runoff occurring over the cover. Calculations
or concepts presented for the cover design, cover slope, cover runoff and cover
drainage velocities do not appear to exist within Appendix M.
• 3.2.9-1
On Page 3-32, the referenced “Part B Attachment II-6 Contingency Plan” is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated February 23,
2022.
• 3.4.1-1
On Page 3-44 the referenced “Part B Attachment II-6 Contingency Plan” is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated February 23,
2022.
• 3.4.3-1
On Page 3-47, the referenced “Part B Attachment II-6 Contingency Plan” is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated
February 23, 2022.
4
• 3.5.1-1
On Page 3-49, the referenced “Part B Attachment II-6 Contingency Plan” is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated
February 23, 2022.
Section 4: Facility Operations
• 4.1.12-1
On Page 4-5 of the Application, it indicates that a review of unplanned events that
have operational safety significance will be performed in accordance with procedure
ES-AD-PR-008 Condition Report (Appendix V). A copy of this procedure is not
included in Appendix V. Please provide a copy of or a link to ES-AD-PR-008 and
identify the correct Appendix location. Three similar statements pointing to ES-AD-
PR-008 are found in paragraphs 4.4.7.3, 8.5 and 9.1.16.
• 4.1.13-1
On Page 4-6, the Application refers to Procedure FCF-SW-PR-203 in Appendix G. It
is named inconsistently within the paragraph, and within Appendix G. This may
cause confusion when trying to find the correct reference. The procedure is called by
the following various names:
1. Federal Cell Facility Waste Acceptance Criteria
2. FCF Waste Acceptance Criteria
3. FCF WAC
4. Federal Cell Facility Acceptance Criteria (in headers)
5. Federal Cell Facility Containerized Waste Acceptance Criteria
6. The Waste Acceptance Criteria (e.g., in tables)
Please name these references and listings consistently to avoid potential confusion or
difficulty in finding the cited procedure. An acronym in addition to the full name
would be acceptable if properly introduced at the beginning.
• 4.4.1.3-1
On Page 4-17, the Application refers to FCF-SH-PR-500 as the Federal Cell Facility
Contingency Implementation Plan (Appendix G). However, that document does not
appear to be found in Appendix G.
5
• 4.4.7-1
On Page 4-24, the Application refers to FCF-SH-PR-500 as the Federal Cell Facility
Contingency Implementation Plan (Appendix G). However, that document does not
appear to be found in Appendix G.
• 4.4.7.3-1
On Page 4-25 of the Application, it indicates that a review of unplanned events that
have operational safety significance will be performed in accordance with procedure
ES-AD-PR-008 Condition Report (Appendix V). A copy of this procedure is not
included in Appendix V. Please provide a copy of or a link to ES-AD-PR-008 and
identify the correct Appendix location.
• 4.4.7-2
On Page 4-24, the “Attachment II-6 of the state-issued Part B Permit” hyperlink sends
users to the DEQ webpage for the Part B Permit, but it does not send them to the
specified attachment. Hyperlink should be updated to the specified attachment.
• 4.5.1-1
On Page 4-26, the referenced “Part B Attachment II-6 Contingency Plan” . is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated
February 23, 2022.
Section 5: Site Closure Plan and Institutional Controls
• 5.1.2.2-1
On Page 5-4, NRC (1986) is cited, but no hot-link or printed reference is provided.
• 5.2.7-1
On Page 5-8, the hyperlink “GWQDP” does not work or is broken.
• 5.3.8-1
On Page 5-12, DOE (2019) is cited, but no hot-link or printed reference is provided.
• 5.3.9-1
On Page 5-12, DOE (2019) is cited, but no hot-link or printed reference is provided.
6
Section 6: Safety Assessment
• 6.1.1.1-1
On Page 6-2, there is a reference to Clive DU PA CSM v2.0. Yet no previous citation
or reference appears to be given for the CSM acronym.
• 6.1.1.1-2
On Page 6-2, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.3-1
On Page 6-6, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.3-2
On Page 6-7, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.4.2-1
On Page 6-10, the Application refers to FCF-SH-PR-500 as the Federal Cell Facility
Contingency Implementation Plan (Appendix G). However, that document does not
appear to be found in Appendix G.
• 6.1.5-1
On Page 6-11, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.5.1-1
On Page 6-13, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
7
• 6.1.5.2-1
On Page 6-15, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.5.3-1
On Page 6-19, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.6.2-1
On Page 6-23, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.6.3-1
On Pages 6-26, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.6.4-1
On Pages 6-27, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.1.4.2-2
On Page 6-10, NRC (1980a) is cited but no hot links, printed references or digital
references are provided.
• 6.3.1-1
On Pages 6-35, there is a reference to Clive DU PA CSM v2.0. While the citation in
each case does make a reference to Appendix O, Appendix O contains 1,131 pages,
and it provides no index to its contents.
• 6.4.2-1
On Page 6-45, a reference is given for “Bingham Environmental, “Hydrogeologic
Report Mixed Waste Disposal Area at Envirocare of Utah Waste Disposal Facility,
South Clive, Utah.” Parts 1 & 2, July 1992. (Bingham Environmental, 1992).” But the
8
citation is given on Page 6-42 as “(Bingham 1992a, b, and c).” In other words, in the
citation, (i) instead of “Bingham Environmental” only “Bingham” is used, (ii) instead
of “1992”, “1992a, b and c” is used, and (iii) instead of references to only Parts 1 and
2, references are given to 1992a, 1992b and 1992c (three documents compared with
two, and letters instead of numbers used to differentiate references from the same
year). In addition, the associated electronic files included in the Application include
only a single, unindexed file called Bingham.pdf consisting of 3,127 pages.
• 6.4.2-1
On Page 6-46, a reference is given for DOE (1989). However, there appears to be no
citation or electronic file submitted for that reference.
Section 7: Occupational Radiation Protection
• 7.1.3-1
On Page 7-3, the Application refers to FCF-AD-PR-100 as the Federal Cell Facility
License Compliance (Appendix J). However, a document having this name does not
appear in Appendix J. A document having a similar but slightly different name and
having the same numerical identification code does exist in the Appendix.
• 7.3.4-1
On Page 7-9, NRC (1993b) is cited. However, NRC (1993b) is not referenced in
Section 7 as a reference, nor is it provided as an electronic file in the Application.
However, there is a reference in the section for NRC (1993a), along with an
electronic file for NRC 1993a.pdf, but no citation in the text for NRC (1993a). Please
adjust the citation and/or reference(s) to make the items mutually consistent.
• 7.3.4-2
On Page 7-10, NRC (1993b) is cited. However, NRC (1993b) is not referenced in
Section 7 as a reference, nor is it provided as an electronic file in the Application.
However, there is a reference in the section for NRC (1993a), along with an
electronic file for NRC 1993a.pdf, but no citation in the text for NRC (1993a). Please
adjust the citation and/or reference(s) to make the items mutually consistent.
• 7.4.5-1
On Page 7-17, the “49 CFR 173” link takes a user to a 49 CFR overview chapter
rather than directly to Part 173.
9
• 7.4.5-2
On Page 7-17, the “49 CFR 173.443” link works, but it is only underlined, not
highlighted in blue. A user might not find the link name easily.
• 7.5.1-1
On Page 7-19, the “49 CFR 172.450” link has a blue highlight, but the hyperlink is
not working.
Section 8: Organizational Structure
• 8.4-1
On Page 8-24 the referenced “Part B Attachment II-6 Contingency Plan” is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated
February 23, 2022.
• 8.4.3-1
On Page 8-25, the “NRC Regulatory Guide 4.20” hyperlink does not work.
• 8.5
On Page 8-26 of the Application, it indicates that a review of unplanned events that
have operational safety significance will be performed in accordance with procedure
ES-AD-PR-008 Condition Report (Appendix V). A copy of this procedure is not
included in Appendix V. Please provide a copy of or a link to ES-AD-PR-008 and
identify the correct Appendix location.
• 8.8.1-1
On Page 8-30 the referenced “Part B Attachment II-6 Contingency Plan” is an
outdated plan from April 25, 2017. Multiple edits have taken place on the
contingency plan since that date, including the list of emergency coordinators. Please
replace the reference given with the current contingency plan dated
February 23, 2022.
10
Section 9: Quality Assurance
• 9.1.2.3-1
On Page 9-7, the last paragraph cites “Nonmandatory Appendix 2A-1” and
“Nonmandatory Appendix 2A-3.” No hot-linked files or printed references appear to
be associated with these file or document names.
• 9.1.16
On Page 9-27 of the Application, it indicates that a review of unplanned events that
have operational safety significance will be performed in accordance with procedure
ES-AD-PR-008 Condition Report (Appendix V). A copy of this procedure is not
included in Appendix V. Please provide a copy of or a link to ES-AD-PR-008 and
identify the correct Appendix location.