Loading...
HomeMy WebLinkAboutDAQ-2024-010169 Utah Division of Air Quality New Source Review Section Company_______________________ Site /Source_____________________ Form 23 Date___________________________ Rotary Kiln Incinerator There are federal standards and guidelines that govern incineration of: Hospital/medical/infectious waste; municipal waste; commercial/industrial waste, cement kilns. Consult 40CFR60, Subparts AAAA, DDDD, EC, and F, as appropriate General Information 1. Flow diagram designations of rotary kiln Incinerator described on this form 2. Manufacturer of Incinerator: __________________ 3. Model name and number: _________________________ 4. Description of material burned: _______________ ________________________________________ 5. Maximum amount of waste to be incinerated: ________________ lb/hr 6. Estimated daily amount of waste to be incinerated: ___________________________pounds per day 7. Height of stack above grade: ___________ feet 8. Height of tallest structures within 150 feet: ___________________________ feet 9. Primary burner used: □ Yes □ No Maximum rating: __________ BTU/hr 10. Secondary Burner used: □ Yes □ No Maximum rating _______________BTU/hr 11. Description of Typical Waste to Be Incinerated: □ Medical/hospital/infectious □ Municipal □ Industrial □ Commercial Operational Information 12. Average operation time of incinerator: ________ hrs/day ________ days/week ________weeks/year 13. Maximum operation time of incinerator: ________ hrs/day ________ days/week ________weeks/year 14. Residence time: Primary ________ seconds Secondary ________ seconds 15. Proposed BACT (Best Available Control Technology): □ Quench Tower □ Heat Exchanger □ Dry Scrubber (DAQ Form 9) □ Wet Scrubber (DAQ Form 9) □ Baghouse (DAQ Form 10) □ Carbon Adsorption Unit 1 2 Form 23 - Rotary Kiln Incinerator (Continued) Emission Information 16. Average Operation Contaminant Concentration or Emission Rate per Identical Source Method Used to Determine Concentration or Emission Rate Particulate Matter PM10 _______ gr/dscf □ lb/106 BTU □ lb/hr Particulate Matter PM2.5 _______ gr/dscf □ lb/106 BTU □ lb/hr Carbon Monoxide CO _______ ppm (vol) □ lb/106 BTU □ lb/hr Nitrogen Oxides NOx _______ ppm (vol) □ lb/106 BTU □ lb/hr Volatile Organic Matter VOC _______ ppm (vol) □ lb/106 BTU □ lb/hr Sulfur Dioxide SO2 _______ ppm (vol) □ lb/106 BTU □ lb/hr Carbon Dioxide (CO2) _______ ppm (vol) □ lb/106 BTU □ lb/hr Methane (CH4) _______ ppm (vol) □ lb/106 BTU □ lb/hr Nitrous Oxide (N2O) _______ ppm (vol) □ lb/106 BTU □ lb/hr 16. Maximum Operation - Continued Contaminant Concentration or Emission Rate per Identical Source Method Used to Determine Concentration or Emission Rate Particulate Matter PM10 ________ gr/dscf □ lb/106 BTU □ lb/hr Particulate Matter PM2.5 ________ gr/dscf □ lb/106 BTU □ lb/hr Carbon Monoxide CO _______ ppm (vol) □ lb/106 BTU □ lb/hr Nitrogen Oxides NOx _______ ppm (vol) □ lb/106 BTU □ lb/hr Volatile Organic Matter VOC _______ ppm (vol) □ lb/106 BTU □ lb/hr Sulfur Dioxide SO2 _______ ppm (vol) □ lb/106 BTU □ lb/hr Carbon Dioxide (CO2) _______ ppm (vol) □ lb/106 BTU □ lb/hr Methane (CH4) _______ ppm (vol) □ lb/106 BTU □ lb/hr Nitrous Oxide (N2O) _______ ppm (vol) □ lb/106 BTU □ lb/hr 16. Maximum Operation - Metals and Toxins- Continued Cadmium: ________________________ milligram/dscf Mercury: ________________________ pounds per hour Lead: ___________________________ pounds per hour Dioxins/furins: ____________________ pounds per hour 17. Exhaust Point Information Flow diagram designation(s) of exhaust point: Description of exhaust point (location in relation to buildings, direction, hooding, etc.): __________________________ 3 Exhaust height above grade: ______________ feet Exhaust diameter: _____________________________ Greatest height of nearby buildings: ___________ feet Exhaust distance from nearest plant boundary: ______feet Average Operation Maximum Operation Exhaust gas temperature: ________________________ Exhaust gas temperature: ________________________ Gas flow rate through each exhaust point: ___________ Gas flow rate through each exhaust point: ___________ Form 23 - Rotary Kiln Incinerator (Continued) Emissions Calculations (PTE) 18. Calculated emissions for this device PM10 ___________Lbs/hr___________ Tons/yr PM2.5 ___________Lbs/hr___________ Tons/yr NOx ____________Lbs/hr___________ Tons/yr SOx ____________Lbs/hr___________ Tons/yr CO ____________Lbs/hr___________ Tons/yr VOC ___________Lbs/hr ___________ Tons/yr CO2 ____________Tons/yr CH4 ___________Tons/yr N2O ____________Tons/yr HAPs __________ Lbs/hr (speciate)___________Tons/yr (speciate) Submit calculations as an appendix. If other pollutants are emitted, include the emissions in the appendix. Instructions NOTE: 1. Submit this form in conjunction with Form 1 and Form 2. 2. Call the Division of Air Quality (DAQ) at (801) 536-4000 if you have problems or questions in filling out this form. Ask to speak with a New Source Review engineer. We will be glad to help! 3. Attach spec. sheets for all burners, pollution control equipment, etc. 1. Attach flow diagram of the described incinerator. 2. Supply the manufacturer of the incinerator. 3. Supply the model and number of the incinerator. 4. Please describe the source of waste to be incinerated. 5. Supply the maximum amount of waste to be incinerated. 6. Specify the daily amount of waste to be incinerated. 7. Indicate the height of the stack above ground level. 8. Indicate the height of tallest structure within 150 feet. 9. Supply the specifications for primary burner used. 10. Supply the specifications for secondary burner used. 11. Indicate the type of typical waste to be incinerated. 12. Supply the average operation time of the incinerator. 13. Supply the maximum operation time of the incinerator. 14. Supply the residence time in the primary and secondary chambers. 15. Indicate the control technology to be use. Submit the corresponding form, if available, for the control technology. Submit specifications for control technology which a form is not available for. Forms available upon request are the following: ___ Form 3 Afterburners ___ Form 4 Flares ___ Form 5 Adsorption Unit ___ Form 6 Cyclone ___ Form 7 Condenser ___ Form 8 Electrical Precipitators ___ Form 9 Scrubber 4 ___ Form 10 Fabric Filter 16. During average and maximum operation, specify the concentration or emission rate of the listed contaminants. 17. Supply the exhaust specifications listed. 18. Supply calculations for all criteria pollutants, greenhouse gases and HAPs. Use AP-42 or Manufacturers data to complete your calculations. f:\ENGINEER\GENERIC\Forms 2010\Form23 Rotary Kiln Incinerators.doc Revised 12/20/10