Loading...
HomeMy WebLinkAboutDAQ-2024-010157 Utah Division of Air Quality New Source Review Section Company_____________________________ Site/Source___________________________ Form 13 Date ________________________________ Spray Booths Exhaust Gas Stream Characteristics 1. Flow Rate (acfm) Design maximum _________ Average expected _________ 2. Exhaust Stack Temperature (oF) __________ Height (ft) __________ Diameter (ft) __________ Vertically restricted? □ Yes □ No 3. Control Device Particulate Loading (lb/hr) Inlet _______ Outlet ________ Type of Coating and Maximum Rate of Use 4. Type Max. rate of use (lb/hr) Max. rate of use (ton/yr) Volatile portion (% weight) lacquer varnish enamel metal primer metal spray resin sealer shellac stain zinc chromate epoxy polyurethane other ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ Solvent or Coating Composition and Rate of Use 5. Chemical composition of volatiles & wt. % _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ 6. Max. rate of use (lb/hr) __________________________ __________________________ __________________________ __________________________ __________________________ 7. Max rate of use (ton/yr) _________________________ _________________________ _________________________ _________________________ _________________________ Page 1 of 2 Page 2 of 2 Form 13 - Spray Booths (Continued) Type Control Device 8. Type of pollution control device: □ spray chamber (use gal/hr water) __________ □ water curtain (use gal/hr water) __________ □ dry filter pads (no.) __________ (size) _____X_____ □ other (explain) □ automated replacement □ manual replacement 9. Method of spraying: 10. _______% overspray 11. ______% efficiency □ air atomization □ disc □ airless electrostatic □ airless □ air-atomized □ powdered □ other (describe) 12. Description of items to be coated (shape and size) Emissions Calculations (PTE) 13. Calculated emissions for this device: PM10 ___________Lbs/hr___________ Tons/yr PM2.5 ___________Lbs/hr___________ Tons/yr VOC ___________Lbs/hr___________ Tons/yr HAPs___________Lbs/hr (speciate)____________Tons/yr (speciate) Submit calculations as an appendix. Attach the following: (1) Material Safety Data Sheet for each coating or solvent. (2) An assembly drawing (plan and elevation) of the device dimensioned and to scale clearly showing the design size and shape. (3) Provide sheets showing VOC emission calculations and HAP specifications. Instructions NOTE: 1. Submit this form in conjunction with Form 1 and Form 2. 2. Call the Division of Air Quality (DAQ) at (801) 536-4000 if you have problems or questions in filling out this form. Ask to speak with a New Source Review engineer. We will be glad to help! 1. The design maximum and average flow rate of the exhaust gas stream. 2. Exhaust stack temperature, stack height, stack diameter, and whether or not the flow is vertically restricted. 3. The amount of particulate released in the paint booth and exhaust gas in pounds per hour. 4. The type of coatings and maximum amount used in an hour and a year. 5. Chemical composition of VOCs and weight in percentage. 6. Maximum rate of use in pounds per hour. 7. Maximum rate of use in tons per year. 8. The type of control equipment you are using. 9. The method of spraying. Mark appropriate box. 10. The percent of paint that is lost in overspray. 11. The percent of efficiency for the equipment. 12. The approximate shape and size of the items being coated. 13. Supply calculations for all criteria pollutants and HAPs. Use AP42 or Manufacturers data to complete your calculations. U:\aq\ENGINEER\GENERIC\Forms 2010\Form13 Paint Booths.doc Revised 12/20/10