HomeMy WebLinkAboutDERR-2024-006920Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name STAKER PARSON MATERIALS AND CONSTRUCTION Address 89 WEST 13490 SOUTH, SUITE 100 DRAPER, UT 84020 Contact STAKER PARSON MATERIALS AND CONSTRUCTION Phone Email christian.boudreau@stakerparson.com TANK LOCATION Name STAKER PARSON REDMOND # F480978 Address 408 W 100 S REDMOND, UT 84652 A Operator None Phone None B Operator SAME Phone SAME Facility ID: 2000742 Inspection Date: 05/01/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 No Jan. 1, 2009 None Yes No None None TANK DETAILS Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 2009 / 20000 / Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material-Mod Concrete-Double-Walled ATG / LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Safe Suction / No STP Flex Connectors Steel Flex in Sump LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Overfill alarm / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankATG PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-05-01 Page 1 of 3 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 2 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes DISPENSER RESPONSES Dispenser 1/2 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Apr '24 Tank 2 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2024-05-01 Page 2 of 3 Prepared by fueloperator.com Inspection Information Inspector:Warner, Sean Record Created:May 1, 2024, 2:39 p.m. Inspection Date:May 1, 2024 2024-05-01 Page 3 of 3