Loading...
HomeMy WebLinkAboutDERR-2024-0068471 UNDERGROUND STORAGE TANK CLOSURE PLAN (rev. 7/13) FACILITY ID# 4000775 … LHD USE ONLY Date Received Reviewer Date LHD Approved Date mailed to State Closure Plan prepared at the request of the owner/operator (identified below) by Josie Messersmith of (company name) Stantec Consulting Services, Inc. Phone # Address City State Zip A Contractor may prepare this Closure Plan as the owner/operator's agent. In preparing the Closure Plan, the Contractor must act with the owner/operator's knowledge and approval. The owner/operator must sign the Closure Plan. Submit Closure Plan to: DERR/UST, P.O. Box 144840, Salt Lake City, Utah, 84114-4840 This Closure Plan is submitted in compliance with the requirements contained in 40 CFR 280 Subpart G and R311-204 (U.A.C.) Piping closure only Tank # 1 2A 2B Tank Type (Steel,FRP,etc.) FRP FRP FRP Piping Type (Steel,FRP,etc.) FRP FRP FRP Date Installed 5/31/2014 5/31/2014 5/31/2014 Capacity 15000 8000 7000 Substance stored* GASOLINE GASOLINE DIESEL Date last operated Currently in use Removal/In Place/Change in Service (CIS)? *Indicate the specific substance stored in each tank to be closed (gasoline, diesel, new oil, waste oil, etc.) For waste oil tanks: Have degreasing or other types of solvents been stored or mixed with the waste oil? Yes (identify if known) . No Not Known Analysis for lead or other contaminants may be required prior to disposal of contaminated soil or other material. (Check with your disposal facility.) STATE USE ONLY Date Received Date Mailed to LHD Date Received From LHD Reviewer/Date Approved Mgr. Review/Date FACILITY INFORMATION Tank Owner TRMC Retail LLC Phone # Address 500 Speedway Drive City Enon State OH Zip 45323 Facility Name Speedway No. 9414 Address 1344 FORT UNION BLVD City SLC State UT Zip 84121 Contact person Phone # Total number of regulated underground tanks at this site 3 Total number of regulated underground tanks at this site to be closed 3 Currently in use Currently in use RemovalRemoval Removal 2890 East Cottonwood Parkway, Suite 300 Salt Lake City UT 84121 5/3/2024 5/3/2024 2 Before the closure plan is submitted for approval, the local health and fire departments where the facility is located must be contacted. CONTACT LOCAL HEALTH DISTRICT: Name of Dist. Date Contact Title Phone# CONTACT LOCAL FIRE DEPT. Name of Dept. Date Contact Title Phone# DISPOSAL INFORMATION Tank(s) will be disposed at: Facility Address City State Zip Contact person Phone# Product lines will either be: removed or cleaned, secured in place, and capped. Vent lines will either be: removed or cleaned and secured open. Piping will be disposed at: Facility Address City State Zip Contact person Phone# Tank(s) will be emptied by: company Phone# Tank(s) will be cleaned by: company Phone# Contaminated water in the tank/rinsate will be disposed at: Facility Contact person Phone# Tank(s) will be: purged or rendered inert by the following method: Residual sludges will be disposed at the following facility: Address City State Zip Contact person Phone# FOR CLOSURE IN PLACE ONLY For this closure method, you are subject to the requirements of UAC R315-302-2(6), which requires annotating the property title and submitting documentation to the Division of Solid and Hazardous Waste (DSHW). For information on how to comply with these requirements, contact the DSHW Solid Waste Landfills Section Manager at (801) 536-0200. Approval for in-place closure has been granted by the Local Fire Department. (Must submit approval in writing with Closure Plan) Fire Dept. Phone# Contact person Date Approval for in-place closure has been granted by the Local Health Department. Health Dept. Phone# Contact person Date Substance to be used to fill tanks: TANK REMOVER Name Cert. # TR Exp. Date Company Phone # Address City State Zip SOIL/GROUNDWATER SAMPLER Name Cert. # GS Exp. Date Company Phone # Address City State Zip x x Greg Neville -0244 10-1-2024 Pacific West Environmental and Infrastructure 1555 W 2200 S, Ste A Salt Lake City UT 84119 801-972-2727 Steve Yorgason 1630 4/15/2025 Stantec Consulting Services, Inc. (801) 261-0090 2890 East Cottonwood Parkway, Suite 300 Salt Lake City UT 84121 Salt Lake County Health Department 5/1/2024 Hayley Schaffer Environmental Health Supervisor (385)468-3816 Unified Fire Authority 5/1/2024 Kendal Perry Hazmat Inspector (801)743-7200 Salt Lake Valley Landfill 6030 W. California Ave. Salt Lake City UT 84104 Scale House (385)468-6370 Salt Lake Valley Landfill 6030 W. California Ave. Salt Lake City UT 84104 Scale House (385)468-6370 Pacific West Environmental and Infrastructure Pacific West Environmental and Infrastructure 801-972-2727 801-972-2727 STC Industrial Services, Inc. Shane Adolf (801)595-8151 x Dry Ice STC Industrial Services, Inc. 618 South 4050 West Salt Lake City UT 84104 Shane Adolf (801) 595-8151 3 SITE ASSESSMENT A site assessment must be performed for all UST closures and change-in-service. Site assessments must be performed as outlined in 40 CFR 280.72 and R311-205 (U.A.C.). If contamination is suspected, additional samples must be collected at the location where contamination is most likely to be present. If groundwater is encountered, a soil sample must be collected, in the unsaturated zone, in addition to each groundwater sample. Soil and groundwater samples must be analyzed for the compounds shown in the following table, using appropriate lab methods. Substance or Product Type Contaminant Compounds to be Analyzed for Each Substance or Product Type ANALYTICAL METHODS1 Soil, Groundwater or Surface Water Gasoline Total Petroleum Hydrocarbons (purgeable TPH as gasoline range organics C6 - C10) EPA 8015 or EPA 8260 Benzene, Toluene, Ethyl benzene, Xylenes, Naphthalene, (BTEXN) and MTBE EPA 8021 or EPA 8260 Diesel Total Petroleum Hydrocarbons (extractable TPH as diesel range organics C10 – C28) EPA 8015 Benzene, Toluene, Ethyl benzene, Xylenes, and Naphthalene (BTEXN) EPA 8021 or EPA 8260 Used Oil Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Benzene, Toluene, Ethyl benzene, Xylenes, Naphthalene (BTEXN) & MTBE; and Halogenated Volatile Organic Compounds (VOX) EPA 8021 or EPA 8260 New Oil Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Other Type of analyses will be based upon the substance or product stored, and as approved by the DERR Division Director Method will be based upon the substance or product type Unknown Total Petroleum Hydrocarbons (purgeable TPH as gasoline range organics C6 - C10) EPA 8015 or EPA 8260 Total Petroleum Hydrocarbons (extractable TPH as diesel range organics C10 – C28) EPA 8015 Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Benzene, Toluene, Ethyl benzene, Xylenes, and Naphthalene (BTEXN) and MTBE; and Halogenated Volatile Organic Compounds (VOX) EPA 8021 or EPA 8260 1 The following modifications to these certified methods are considered acceptable by the DERR Division Director: •Dual column confirmation may not be required for TPH and BTEXN/MTBE analysis. •A micro-extraction or scale-down technique may be used for aqueous samples, but only for the determination of extractable TPH as diesel range organics (C10 – C28). •Hexane may be used as an extraction solvent. •*Silica Gel Treatment (SGT) may be used in the determination of Total Recoverable Petroleum Hydrocarbons. NOTE: The sample preparation method and any modification(s) to a certified method must be reported by the laboratory. 4 CONTAMINATED MATERIALS MUST BE DISPOSED AT AN ACCEPTABLE FACILITY: All materials generated from UST closures must be managed and disposed in a manner that does not place those materials in direct contact with the environment. On-site stockpiling of contaminated soils may be required prior to any soil management activities. Any person providing remedial assistance for a fee, including aeration and over-excavation (of more than 50 yd3), must be a Certified UST Consultant. Contaminated soils generated as part of tank removal are to be disposed at the following facility: Address City State Zip Contact person Phone Complete the Facility Site Plat and Sample Information Table on pages 4 and 5 to provide site assessment information. CONTAMINATION INFORMATION If contamination at the facility is suspected or confirmed, the information must be reported to the DERR Division Director at (801) 536- 4100 within 24 hours. The Division of Water Quality must be notified at (801) 536-4300 if Free Product is encountered or if surface water has been impacted. If contamination is confirmed, any person assisting in the remediation process for a fee must be a Certified UST Consultant. SAMPLE INFORMATION TABLE Complete table for all samples to be taken for closure. 1 Soil (SS), Groundwater (GW), or Unified Soil Classification (USC). 2 Approx. depth in feet below grade. The required minimum site assessment samples must be taken at 0-2 feet below the backfill/native soil interface. 3 Contaminant compounds to be analyzed for each sample (from table on p. 3). 4 Appropriate analysis methods for contaminant compound(s) in each sample (from table on p. 3). Sample # Substance stored in tank Sample type1 Depth2 Compounds3 Analysis method(s)4 SS-1 SS-2 SS-3 SS-4 SS-5 SS-6 SS-7 SS-8 SS-9 Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel GW-1 GW-2 USC-1 USC-2 USC-3 Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel Gasoline/Diesel SS SS SS SS SS SS SS SS SS GW GW USC USC USC MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO MBTEXN and TPH-GRO & DRO USC USC USC 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 8260/8015 ASTM-D2487 ASTM-D2487 ASTM-D2487 8 8 12-14 12-14 3-5 3-5 12-14 3-5 3-5 3-5 3-5 3-5 3-5 3-5 Intermountain Regional Landfill 800 S Allen Ranch Road Fairfield UT 84013 Bryan Alba (801)865-2624 5 Facility Site Plat (Closure Plan) The site plat must be drawn to an appropriate identified scale. It must show planned sampling locations, substances stored in tanks, and other relevant information. Tank and sample identification numbers must be consistent with the information given on pages 1 and 4 of the Closure Plan. Facility ID: Drawn By: Date: X = Sample locations (SS-#, WS-#, USC-#) Site Plat Must Indicate Approximate Locations of: ●= Monitoring Wells (MW-#)-Current & former tanks, piping & dispensers ○= Soil boring (SB-#), or Geoprobe Boring (GP-#)-Location of all samples to be taken ◘= Water Wells (domestic, livestock, etc.)-Buildings, fences, & property boundaries Slope of Surface Topography: (N,NW,W,SW,S,SE,E,NE)-Utility conduits (sewers, gas, water, storm drains, electrical, etc.) Land Use At Site: Residential Commercial Industrial Surrounding Land: _ Residential Commercial Industrial North Scale: 1”= Feet 6 Approximate depth to groundwater in the vicinity of the tanks: feet. Regional groundwater flow direction: State Certified Laboratory to be used: Address City State Zip Contact Person Phone I certify under penalty of law that I am the owner/operator of the tank(s) referenced above and that I am familiar with the information on this form and that it is true, accurate and complete, and further, that the procedures described herein will be followed during tank closure. Signature of tank owner Full Name of tank owner Date Please explain any unusual or extenuating circumstances expected regarding the site assessment or closure: 8 North - Northwest As the depth of backfill was not available from historic records, the depths of soil samples, groundwater samples and USC samples are approximations, based on sites with similar tanks and GW levels. All depths should be confirmed and/or appropriately adjusted after field activities determine backfill depth. This site has had at least one historic leak, in 2012, and had 4 steel tanks closed in 2014. Pace National Analytical 12065 Lebanon Road Mt. Juliet TN 37122 Marty Edwards (615) 758-5858 © 2024 Microsoft Corporation © 2024 Maxar ©CNES (2024) Distribution Airbus DS RUL CANOPY/DISPENSERS PUL DSL CAR W A S H SPEEDWAY Store No. 9414 East Fort Union BLVD -SIDEWALK- -CON C R E T E - OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE P PPP P P P P P P P P P P P P PPP P P P P P P P P P P P P P P P P P P P P P P P P P P P PP P PP P The UPS Store Protein Foundry Great Clips ELECTRIC CONNECTION BOXES AIR/VACUUM DUMPSTER STORE SIGN -ASPH A L T - -ASPH A L T - -ASPH A L T - -ASPH A L T - CONCRETE UST AREA -C O N C R E T E - ELECTRIC CONNECTION BOX DRAINAGE GRATE N 0 20 40 APPROXIMATE SCALE IN FEET No warranty is made by Stantec as to the accuracy, reliability, or completeness of these data. Original data were compiled from various sources. This information may not meet National Map Accuracy Standards. This product was developed electronically, and may be updated without notification. Any reproduction may result in a loss of scale and or information. FILEPATH:\\us0395-ppfss01\shared_projects\203723864\05_report_deliv\drawings_design\cad_fig\Speedway 9414.dwg|cclee|Apr 17, 2024 at 12:50|Layout: 9414-SM 410 17th Street Suite 1400 Denver, Colorado 80202 LEGEND: APPROXIMATE PROPERTY BOUNDARY OVERHEAD ELECTRIC PRODUCT LINE POWER POLE SITE LAMP P OE FOR: CHECKED BY:DRAWN BY:JOB NUMBER:APPROVED BY:DATE: FIGURE: 1SITE MAP TFJMCCL2037XXXXX 4/16/2024 SPEEDWAY No. 9414 1344 FT UNION BLVD COTTONWOOD HEIGHTS, UTAH 84121 SS-1/USC-1 GW-1 SS-2 GW-2 SS-3SS-4/USC-2 SS-5 SS-6 SS-7 SS-8/USC-3 SS-9