Loading...
HomeMy WebLinkAboutDERR-2024-006830Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name MILFORD CHEVRON Address P O BOX 929 MILFORD, UT 84751 Contact MILFORD CHEVRON Phone Email DAVIS_KENDRA@YMAIL.COM TANK LOCATION Name MILFORD CHEVRON Address 402 S MAIN ST MILFORD, UT 84751 A Operator TERRY WISEMAN Phone (435) 387-5566 B Operator RILEY ROSE Phone SAME Facility ID: 6000171 Inspection Date: 04/29/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 Gas/Diesel No None None No No None None 2 - 3/4 Gas/Diesel No None None No No None None TANK DETAILS Tank ID/Alt ID 4 / 4 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 8000 / Substance Stored Gasoline / Regular Tank Material- Mod Asphalt Coated or Bare Steel- Secondary Containment ATG / LTT Test None LLD Test None Pipe Material- Mod Unknown / Secondary Containment Pipe type/STP Cont Gravity Feed / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankLDNotListed PipeAutoLineLeakDetection CP Tank Test None CP Pipe Test None Tank ID/Alt ID 5 / 5 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 8000 / Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Asphalt Coated or Bare Steel- Secondary Containment ATG / LTT Test None LLD Test None Pipe Material-Mod Unknown / Secondary Containment Pipe type/STP Cont Gravity Feed / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None 2024-04-29 Page 1 of 4 Tank ID/Alt ID 6 / 6 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 5000 / Substance Stored Gasoline / Premium Tank Material- Mod Asphalt Coated or Bare Steel- Secondary Containment ATG / LTT Test None LLD Test None Pipe Material-Mod Unknown / Secondary Containment Pipe type/STP Cont Pressurized / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-04-29 Page 2 of 4 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 5 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 6 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 4 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 6 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Tank 6 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes DISPENSER RESPONSES Dispenser 3/4 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 1/2 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tank 5 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 6 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS 2024-04-29 Page 3 of 4 Prepared by fueloperator.com All items are in compliance. Inspection Information Inspector:Warner, Sean Record Created:April 29, 2024, 1:12 p.m. Inspection Date:April 29, 2024 2024-04-29 Page 4 of 4