Loading...
HomeMy WebLinkAboutDERR-2024-006793Underground Storage Tank Inspection Verification Form Facility ID:9000221 Owner Name:WIND RIVER PETROLEUM Facility Name:TOP STOP C-40 Owner Address:5097 S 900 E, SUITE 200 Street Address:1355 E HWY 40 SALT LAKE CITY, UT 84117 VERNAL, UT 84078 Operator A:JESSICA KUDDES / (435) 753-1025 / 1/20/2025 Operator B:DUSTI BURTON / (801) 272-9229 / 1/20/2025 Owner Email:jkuddes@topstopstores.com UTM Coordinates X/Y:627047 / 4478736 Disp ID/Alt ID Substance UDC Pipe Flex Loc Install Date UDC Install Date Fire Valve Sat Present UDC Test Disp Flex CP Test 1 - 1/2 Gasoline No Booted Steel Flex Yes No 2 - 3/4 Gasoline No Booted Steel Flex Yes No 3 - 5/6 Gasoline No Booted Steel Flex Yes No 4 - 7/8 Gasoline No Booted Steel Flex Yes No 5 - 9/10 Diesel Yes Steel Flex in Sump Yes Yes 6 - 11/12 Diesel Yes Steel Flex in Sump Yes Yes 7 - 13/14 Diesel Yes Steel Flex in Sump Yes Yes 8 - 15/16 Diesel Yes Steel Flex in Sump Yes Yes 9 - 17/18 Diesel Yes Steel Flex in Sump Yes Yes Tank ID/Alt ID:1 / 2 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Galvanized Steel - None Siphon/Compart:No / No PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use Co-axial STP Flex Connectors: Installed/Cap/Loc:6/1/1950 / 17000 / North Center LLD Model: Substance Stored:Gasoline / Regular Spill/Overfill/Sm deliv:Dry Connect Fitting / Overfill alarm / No Tank Material-Mod:Asphalt Coated or Bare Steel - None PST Fund/Other Type:No / Insurance ATG:Veeder Root / Tank/Pipe Rel Det:OTHER / LTT / NONE ATG Specs: / / STP Sump Test:Spill Bk Test: ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:2 / 1 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Galvanized Steel - None Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors: Installed/Cap/Loc:6/1/1950 / 10000 / North LLD Model: Substance Stored:Diesel / Diesel #2 (U.L.S.)Spill/Overfill/Sm deliv:Dry Connect Fitting / Overfill alarm / No Tank Material-Mod:Asphalt Coated or Bare Steel - None PST Fund/Other Type:No / Insurance ATG:Veeder Root / Tank/Pipe Rel Det:OTHER / LTT / NONE ATG Specs: / / STP Sump Test:Spill Bk Test: ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:3 / 4 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Galvanized Steel - None Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors: Installed/Cap/Loc:6/1/1950 / 12000 / South LLD Model: Substance Stored:Gasoline / Premium Spill/Overfill/Sm deliv:Dry Connect Fitting / Overfill alarm / No Tank Material-Mod:Asphalt Coated or Bare Steel - None PST Fund/Other Type:No / Insurance ATG:Veeder Root / Tank/Pipe Rel Det:OTHER / LTT / NONE ATG Specs: / / STP Sump Test:Spill Bk Test: ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:4 / 3 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Galvanized Steel - None Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No 4/30/2024 Page 1 of 2 Tank Status:Currently In Use STP Flex Connectors: Installed/Cap/Loc:6/1/1950 / 12000 / South Center LLD Model: Substance Stored:Diesel / Diesel #2 (U.L.S.)Spill/Overfill/Sm deliv:Dry Connect Fitting / Overfill alarm / No Tank Material-Mod:Asphalt Coated or Bare Steel - None PST Fund/Other Type:No / Insurance ATG:Veeder Root / Tank/Pipe Rel Det:OTHER / OTHER / NONE ATG Specs: / / STP Sump Test:Spill Bk Test: ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:5 / 5 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Galvanized Steel - None Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors: Installed/Cap/Loc:6/1/2002 / 9600 / East LLD Model: Substance Stored:Diesel / Off-road Diesel Spill/Overfill/Sm deliv:Containment Sump / Overfill alarm / No Tank Material-Mod:Asphalt Coated or Bare Steel - None PST Fund/Other Type:No / Insurance ATG:Veeder Root / Tank/Pipe Rel Det:OTHER / LTT / NONE ATG Specs: / / STP Sump Test:Spill Bk Test: ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: 4/30/2024 Page 2 of 2