HomeMy WebLinkAboutDAQ-2024-0077461
DAQC-PBR036240001-24
Site ID 3624 (B1)
MEMORANDUM
TO: FILE – OVINTIV USA INC. – Beckstead 13-17-4-2W
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager
FROM: Stephen Foulger, Environmental Scientist
DATE: April 22, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: March 28, 2024
SOURCE LOCATION: Beckstead 13-17-4-2W
Lat: 40.12928 Long: -110.13967
Business Office:
370 17th Street, Suite 1700
Denver, CO 80202
SOURCE TYPE: Tank Battery
Duchesne County
API: 4301350447
SOURCE CONTACTS: Brandon Lithgoe, Local Contact
Phone: (281) 847 6093, Email: Brandon.Lithgoe@ovintiv.com
Ryan Zillner, Local Contact
Phone: 720-876-3144, Email: ryan.zillner@ovintv.com
OPERATING STATUS: Temporarily down
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart JJJJ, 40 CFR 60 Subpart
OOOO.
2
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
No Flare Controls
Site powered by Engine
The source registered: 3,199 Estimated Oil BBL.
DOGM current 12 month rolling production is: 460.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make - Ajax
Model - E-565 Mfg Year - 2010 Horse Power - 40 Combustion -
Natural Gas, Pneumatic, Tank
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance. Source found properly registered at the time of inspection.
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance. Source found properly registered at the time of inspection.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. Thief hatches found closed and latched at the time of inspection.
Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. Combustor was removed after production levels dropped appropriate levels.
Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled
per R307-506-4(2)[R307-506-5]
In Compliance. These records were reviewed and found to be compliant at the time of inspection.
Natural Gas Engines
Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance.
3
Visible Emissions
Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance. No visible emissions were observed at the time of inspection.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. This source was found properly reported in the 2020 emissions inventory.
NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion
Engines [40 CFR 60 Subpart JJJJ]
In Compliance.
NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to Beckstead 13-17-4-2W:
In Compliance - Source was found compliant at the time of
inspection. Source is currently shut-in for fracking protection.
Recommend to decrease inspection frequency.
RECOMMENDATION FOR
NEXT INSPECTION: Recommend to decrease inspection frequency.
ATTACHMENTS: