Loading...
HomeMy WebLinkAboutDDW-2024-007397Contacts Type: Administrative Contact Name: KENNY ENGLAND Office: 801-525-4430 Emergency: Email: kenny.england@clearfieldcity.org Site Information Legal Contact: CLEARFIELD CITY Address: 55 S STATE ST , CLEARFIELD, UT 84015 Phone: 801-525-2700 County: DAVIS COUNTY System Type: Community Certification Required: D4 Total Population: 33540 Local Health District: Davis County Health Department Site Updates Last Inventory Update: 12/20/2023 Last Surveyor Update: Surveyor: Operating Period: / - / Last IPS Update: 04/18/2024 18:03:15 Political Districts Representative: 14 Senate: 21 Water Usage Information per ERC Total Ips Points: 105 Public Water System IPS ReportDEQ | Drinking Water Clearfield City Water System PWS ID: UTAH06002 Rating: Approved 03/04/1980 Status: Active IPS SUMMARY Total IPS Points: 105 Admin & Physical Facilities Quality & Monitoring Significant Deficiency Violations 55 0 50 PHYSICAL FACILITY POINTS Total Pts: 55 Facility Facility Name Status Points Effective Details DS001 DISTRIBUTION SYSTEM A 15 Hide Details ( 1 ) Code Description Severity Comments Determined Date Pending Assessed A025 Administrative issues - see notes for specific details MIN WATER USE DATA -INFORMATION NECESSARY TO ESTABLISH THE SYSTEM SPECIFIC STANDARDS 01/01/2020 0 15 ST002 HILL AIR FORCE BASE TANK A 25 Hide Details ( 4 ) Code Description Severity Comments Determined Date Pending Assessed V011 END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG Could not see 10/02/2023 25 25* (group- 35) V012 END OF STORAGE TANK OVERFLOW PIPE LACKS NO. 4 SCREEN SIG Could not see 10/02/2023 0 25 V013 STORAGE TANK OVERFLOW PIPE IS CONNECTED TO OR DISCHARGES TO SANITARY SEWER SIG Could not see 10/02/2023 50 0 V016 END OF TANK DRAIN LINE LACKS A CLEARANCE OF AT LEAST 12 INCHES SIG Could not see 10/02/2023 25 0 ST006 NEW FREEPORT TANK A 0 Hide Details ( 1 ) Code Description Severity Comments Determined Date Pending Assessed V011 END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG Over flow line is in a receiving basin below ground surface 10/02/2023 25 25* (group- 35) TP001 700 SOUTH FLUORIDATION A 15 Hide Details ( 1 ) Code Description Severity Comments Determined Date Pending Assessed TF44 NO SAMPLE TAP AVAILABLE FOR TESTING FL LEVEL IN TREATED WATER MIN 10/02/2023 0 15 WS001 RESERVOIR WELL I 0 Hide Details ( 1 ) Code Description Severity Comments Determined Date Pending Assessed S009 PUMP TO WASTE LINE LACKS PROPER AIR GAP SIG Discharges to storm drain.10/02/2023 25 0 WS006 HILL AFB WELL I 0 Hide Details ( 1 ) PHYSICAL FACILITY POINTS Total Pts: 55 Facility Facility Name Status Points Effective Details Code Description Severity Comments Determined Date Pending Assessed S024 NO CHECK VALVE ON WELL DISCHARGE PIPING MIN Did not have a check valve.09/29/2020 5 SIGNIFICANT DEFICIENCY VIOLATIONS Total Pts: 50 ID Violation Code Deficiency Determined Points Effective ST002 45 FAILURE ADDRESS DEFICIENCY (GWR) V012 END OF STORAGE TANK OVERFLOW PIPE LACKS NO. 4 SCREEN 04/18/2024 50 LEAD COPPER MONITORING AND QUALITY VIOLATIONS Total Pts: 0 Violation No.Period Code Description/Name Points Effective CHEMICAL MONITORING RULE VIOLATIONS Total Pts: 0 Facility Violation No Period Code Violation Type Analyte Group Determined Seasonality Points Effective TREATMENT VIOLATIONS Total Pts: 0 Facility Violation No Period Code Violation Type Analyte Group Determined Points Effective MICROBIAL RULE VIOLATIONS Date Range Start: 04/01/2023 Total Pts: 0 Determine Date Compliance Period Code Violation Type Return To Compliance Points Effective OPERATOR CERTIFICATION Type Level Required Highest Certificate Distribution Dist 4 Dist 4 Treatment CONSUMER CONFIDENCE REPORT Total Effective Points: 0 Violation No.Period Code Description/Name Points Effective PUBLIC NOTIFICATION VIOLATIONS Total Pts: 0 Violation No.Date Code Description/Name Points Effective IPS COMPLIANCE SCHEDULES Type Required Activities Severity Created Due CCR SCHEDULES Submit Consumer Confidence Report 01/01/2024 07/01/2024 CCR SCHEDULES Submit CCR Certification Letter 01/01/2024 10/01/2024 CORRECTIVE ACTION PLAN END OF STORAGE TANK OVERFLOW PIPE LACKS NO. 4 SCREEN SIG 10/13/2023 03/15/2024 CORRECTIVE ACTION PLAN END OF TANK DRAIN LINE LACKS A CLEARANCE OF AT LEAST 12 INCHES SIG 10/13/2023 12/01/2024 CORRECTIVE ACTION PLAN END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG 10/13/2023 12/01/2024 CORRECTIVE ACTION PLAN PUMP TO WASTE LINE LACKS PROPER AIR GAP SIG 10/13/2023 12/01/2024 CORRECTIVE ACTION PLAN END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG 10/13/2023 12/01/2024 CORRECTIVE ACTION PLAN STORAGE TANK OVERFLOW PIPE IS CONNECTED TO OR DISCHARGES TO SANITARY SEWER SIG 10/13/2023 12/01/2024 Lead Copper Rule Revisions SUBMIT LEAD SERVICE LINE INVENTORY 12/16/2021 10/16/2024 Lead Copper Rule Revisions COMPLETE INITIAL LSL INVENTORY 12/16/2021 10/16/2024