Loading...
HomeMy WebLinkAboutDERR-2024-006670Underwood Environmental Consulting, Inc. 9475 N. Silver Creek Road  Park City, Utah 84098  Phone 801-831-6966  Fax 888-472-0977 ABATEMENT REPORT FOR K & C TRADING POST 161 EAST MAIN STREET BLUFF, UTAH FACILITY ID #5000084 RELEASE SITE OIV April 25, 2024 Prepared by: Underwood Environmental Consulting Park City, Utah Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. i EXECUTIVE SUMMARY Underwood Environmental Consulting, Inc. (UEC) has been retained by Mr. Vance Nielson (JVP, Inc.) to conduct abatement activities at the K & C Trading Post Sinclair station (project site). The project site is located at 161 East Main Street in Bluff, Utah. Abatement activities were performed in March 2024 to remove impacted soils resulting from a leaking fiberglass gasoline underground storage tank (UST). Abatement activities were performed during the removal and replacement of the UST fueling system. The K & C facility is the only operating retail gas station in the town of Bluff. The following summary of events and conclusions are based on field observations, and the soil analytical results obtained during abatement activities: • On September 18, 2023 a release was reported based on a failed automatic tank gauging (ATG) test. The release was confirmed by a certified tank tester and the leaking premium gasoline UST compartment was emptied of fuel. The regular gasoline UST compartment remained in service. • In February of 2024 a subsurface investigation was performed resulting in the installation of four monitoring wells to depths of approximately 25 feet. Approximately 0.65 feet of free product (gasoline) was detected in groundwater at a depth of 19.3 feet in MW-3. • In order to minimize down time for the fueling station the abatement plan was scheduled the week prior to the arrival of a new replacement UST. On March 6th, 2024 the entire UST system was removed and on March 13th, 2024 the new tank arrived and installation began. • Excavation of impacted soils commenced during the UST removal on March 6th, 2024. Excavation activities were severely limited by the proximity of the canopy structure to the south and overhead power lines and utilities to the north. • Between March 6th and March 11th approximately 862 tons of impacted soil was excavated and hauled to a land farm location south of Monticello, Utah. To the extent possible, lesser impacted soil (overburden) was segregated and hauled to a gravel pit a few miles from Bluff. • Soil sampling was performed prior to and during the UST removal and during abatement activities. Sampling was limited in the west portion of the excavation due to collapsing sidewalls. Floor samples were acquired throughout the length (east-west) of the excavation and from the sidewalls of the east portion. • Analytical results from soil samples acquired indicate that six of seven floor samples (13-14 feet deep) were below ISLs and all seven sidewall samples (8-12 feet deep), taken from the central and east portions of the excavation, were below ISLs. • Data from the subsurface investigation (Feb 2024) identified a substantial clay layer at 13-15 feet which partially inhibited downward migration of impacts to the groundwater at 19-20 feet. However, groundwater impacts were documented in the investigation suggesting the clay layer was permeated. Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. ii Based on the summary points presented above, UEC recommends additional investigation and monitoring well installation. This should be followed by a high vacuum extraction event, utilizing select wells, to remove free product and vapor phase hydrocarbons from the subsurface. This recommendation is largely based on the environmental sensitivity of the project site including two on-site artesian wells. Respectfully Submitted, Underwood Environmental Consulting, Inc. L. Earl Underwood, P.G. Project Geologist, CC-0018 Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. iii TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 BACKGROUND 3.0 SITE DESCRIPTION 4.0 SOIL ABATEMENT ACTIVITIES 4.1 CANOPY SUPPORT SYSTEM 4.2 UST REMOVAL AND EXCAVATION 4.3 SOIL SAMPLING 4.4 ANALYTICAL RESULTS 4.5 LANDFARMING 5.0 QUALITY ASSURANCE AND QUALITY CONTROL 6.0 CONCLUSIONS AND RECOMMENDATIONS 7.0 LIMITATIONS References Cited LIST OF FIGURES Figure 1 Area Topo Map Figure 2 Site Area Map Figure 3 Site Map Figure 4 Excavation Sample Locations LIST OF TABLES Table 1 Soil Sample Analytical Results Table 2 Groundwater Monitoring Data APPENDICES Appendix A Photo Documentation Appendix B Laboratory Analytical Reports and Chain of Custody Documentation Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 1 1.0 INTRODUCTION Underwood Environmental Consulting, Inc. (UEC) has been retained by Mr. Vance Nielson (JVP, Inc.) to conduct abatement activities at the K & C Trading Post Sinclair station (project site). The abatement was approved under work plan OIV-02 and amendments. Public notification was initiated on February 12th, 2024. The project site is located at 161 East Main Street in Bluff, Utah. Abatement activities were performed in March 2024 to remove impacted soils resulting from a leaking fiberglass gasoline underground storage tank (UST). Abatement activities were performed concurrent with the removal and replacement of the UST fueling system. 2.0 BACKGROUND The K & B Trading Post facility has occupied the same location for several decades. The facility contained a former UST fueling system which was removed on November 27, 1995. A release (EJHB) was issued based on one UST closure soil sample with hydrocarbon concentrations above detection limits. Release EJHB was subsequently closed on February 8, 1996. According to DERR records the two 6000 gallon steel gasoline USTs were 10 years old at the time of removal. The removed UST system was replaced in the same month (November 1995) with a 15,000 gallon fiberglass compartmental UST. New dispensers, lines and a canopy were also installed at that time. The canopy was installed after the new UST system was installed, according to the facility owner. On September 18, 2023 a release was reported to the Utah Division of Environmental Response and Remediation (DERR) based on the automatic tank gauging (ATG) test which alarmed the facility owner that the 5000 gallon premium gasoline compartment was losing fuel. The DERR opened a release code OIV for the site. The release was confirmed by a certified tank tester and the leaking premium gasoline UST compartment was emptied of fuel. A vacuum test was performed on the empty compartment and acoustical methodology indicated a slow ingression of water in the lower portion of the compartment. The remaining 10,000 gallon regular gasoline UST compartment passed the tank test and remained in service. It should be noted that the K & C Trading Post Sinclair is the only operating retail fueling facility in the town of Bluff, Utah. The facility owner promptly ordered a new replacement tank and contracted the installation of a new fueling system. In February of 2024 an initial subsurface investigation was performed across the project site resulting in the installation of four monitoring wells to a depth of approximately 25 feet. Soil and groundwater samples from MW-1 (east of the UST) exceeded Tier 1 levels while a monitoring well southwest of the UST (MW- 3) contained 0.65 feet of free product. A substantial clay layer was contacted in each boring at about 13 - 15 feet below grade. The groundwater was contacted at a depth of 19-20 feet (below the clay layer) in a sand and gravelly-sand zone. The groundwater gradient was determined to be very low (.001 ft/ft) towards the southwest. On March 6, 2024 the UST and ancillary piping were removed. On March 13, 2024 an upgraded double walled fiberglass compartmental UST of the same size and capacity was installed. An Abatement was performed during UST removal and replacement activities resulting in the removal of approximately 862 tons in gasoline impacted soil. Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 2 3.0 SITE DESCRIPTION The project site is located in San Juan County, Utah in the town of Bluff, population 320 (2000 census). Bluff is located in the sparsely populated four corners region in southeast Utah within the Colorado Plateau Province. The town is nestled between sandstone cliffs and the San Juan River. The site is located on the south side of Highway 191 adjacent to Cottonwood Wash to the east at an elevation of approximately 4,320 feet. The San Juan River is located approximately 3400 feet south of the site. The surface topography slopes gently to the south towards the river. Groundcover consisted of of asphalt pavement, concrete, gravel, and landscaping. The Recapture Lodge hotel borders the site to the east while a public laundromat is located to the northwest across Hwy 191. The project site contains a fueling station (Sinclair), a convenience store (K & C Store) and a hotel (Kokopelli Inn). A residential dwelling is located south of the store. Utilities border the site to the north along Main Street (water, phone/communications and overhead power). Power is connected to the facility by overhead lines. Culinary water is connected underground to the hotel and which feeds into the store. There is no municipal sewer or natural gas. A propane tank located south of the store supplies the store and hotel. Septic systems are located south of the hotel and store. A storm drain inlet box exists in the northwest corner of the store and drains towards the southwest daylighting west of the hotel. Two artesian wells are located on site. The wells are listed under water rights number 09-196. Well #1 is located due north of the Kokopelli Hotel on the west side of the site. Well #2 is located on the east side of the site near the Recapture Lodge. Well #1 is currently shut in and was used primarily for irrigation, according to the owner. Well #2 feeds a yard hydrant at the northeast corner of the store and is also shared with the Recapture Lodge. Well #2 is currently in use. An above ground 2000 gallon diesel tank is located east of the store. The diesel tank has no underground piping. The underground storage tank (UST) system, removed on March 6, 2024, contained one 15,000 gallon compartmental fiberglass tank which fed two dispensers under a canopy structure. The UST contained a 5,000 gallon premium unleaded gasoline compartment and a 10,000 gallon unleaded gasoline compartment. 4.0 SOIL ABATEMENT ACTIVITIES 4.1 Canopy Support System Due to the proximity of the canopy structure to the UST a canopy support system was necessary for excavation safety and to preserve the canopy. The canopy columns/footings were located 15 feet from the center line of the UST. The general contractor (Sonderegger, Inc.) designed and constructed a temporary support system which connected steel beams from the canopy columns to concrete anchors placed south of the structure. The support system was installed prior to excavation activities. Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 3 4.2 UST Removal and Excavation The excavation work began on March 5th 2024 with removal of shallow clean overburden and deeper impacted soil adjacent the UST. The UST was removed on March 6th 2024 and abatement activities continued through March 13th 2024 when the new UST was installed. Impacted soils, based on screening with a calibrated Photo Ionization Detector (PID), was contacted around 5-6 feet below grade and extended to a stiff clay layer at 13-14 feet. Once the UST was removed it was inspected and hauled to the San Juan County Landfill. The UST inspection was inconclusive as to the cause of failure. Excavation began in the west side of the UST excavation. Soil Samples were obtained from the clay layer at the bottom or floor of the excavation as part of the tank closure sampling. Mr. David Wilson (DERR UST Scientist) was on site for the tank removal and sampling. The excavation extents were limited in the north and south directions by the existing canopy and overhead power lines / utilities along Main Street (Hwy 191). Overhead power lines also limited excavation to the west. Soon the only feasible approach to access targeted soils was from the east side. The Trackhoe created a ramp to enter the excavation from the east end and scraped excavated soils along the clay layer up the ramp and then placed them in a stockpile. A large loader and other heavy equipment were used to transfer the stockpiled soil to the truck loading area on the east side of the site. During this process the sidewalls in the west portion of the excavation started to collapse spontaneously. The excavation work was ceased to avoid further collapse. Excavated soils were loaded into trucks and hauled to the disposal location. The resulting excavation exposed the canopy footing on the east side but the support system held the structure in place. A sign was undermined on the north side and underground utilities were at risk. The general contractor arranged for an emergency backfill of the west portion of the excavation on the following day. On March 7th Rock Chuckers, LLC mobilized an aggregate conveyor system to the site. Gravel, delivered to the site by Sonderegger, was “sprayed” into the excavation stabilizing the sidewalls and covering the exposed canopy footings. During the process the soils which fell into the excavation were carefully removed and placed into the stockpile area. Soil screening and observation during the excavation process was performed. Gravel and silty sand immediately below the former UST appeared saturated with a water and fuel mixture. The water was assumed to be surface water perched on top of the clay layer and was only a few inches deep. Pumping of the water was not feasible and the liquids were mixed with the dryer soils during excavation. There were no free liquids in the stockpiled soil which was hauled away. PID reading were obtained from grab samples obtained from the stockpile during the entire abatement process. Readings varied from 6 ppm to over 1200 ppm averaging around 600 ppm. At times the gasoline fumes at the surface were excessive and a vapor suppressant product was used. Microblaze Emergency Liquid Spill Control was sprayed onto excavated soils which dramatically reduced ambient vapors and odors in the working area. Random grab soil samples from the stockpile were acquired and later analyzed by the laboratory. On March 7th, After the west end on the excavation was secured, excavation of impacted soils continued. The Microblaze product was applied more or less continuously as impacted soils were generated. Soils were hauled to the disposal location (land farm south of Monticello) throughout the day resulting in 538 tons (18 truck and pup loads) of impacted soils hauled in two days. The excavation was secured for the weekend with fencing and jersey barricades. Soil samples obtained up to that point were transported to Saly Lake City for laboratory analysis. Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 4 On March 11th excavation continued in the east direction. Soils in the sidewalls were reasonably stable allowing for confirmatory soil sample acquisition. When the excavation reached the point which would have been the east end of the UST and failed premium gasoline compartment, PID levels in ambient air became extreme. Screening of stockpiled soils indicated a “hot spot” east of the former tank extending east about 15 feet towards monitoring well MW-1. The excavation continued eastward until PID screening indicated that the east extent of impacts had been removed. Unfortunately monitoring well MW-1 was destroyed. Several confirmation samples were, however, obtained from the area. A total of 11 loads of impacted soil were hauled to the landfarm and eight loads, mostly overburden, were hauled to the clean location. The project totals for impacted soil excavated and hauled to the landfarm was 862.44 tons and clean soil hauled away totaled 431 tons. On March 12th plans were formulated to relocate the new UST further east due to the emergency backfilling of the west end on the excavation. The tank installation crew began preparations for the arrival of the new UST on March 13th. During the tank installation two 4” diameter PVC well screens were installed inside the excavation adjacent the new tank for future use as extraction and/or monitoring wells. The well casings/screens would be used as raceways or manways to accommodate the drilling and installation of 2” diameter wells to depths of 25 feet without endangering the new tank or ancillary piping and conduits. The 4” wells were completed with traffic rated manholes at the surface once the area was resurfaced. Other areas which may be used as future treatment or monitoring well drilling locations were identified during the UST System installation by carefully documenting the location of piping and electrical lines. During the UST installation process UEC inspected the site and met with the general contractor to document and determine areas that were damaged by the abatement activities and would therefore need be resurfaced to restore the property back to its original condition. The owner and general contractor opted to use concrete over areas which were originally asphalt in part due to the lack of nearby asphalt plants. Areas which were originally asphalt would, however, have to be reimbursed at the general contractors approved unit rates for asphalt per DERR reimbursement rules. Photographs of the excavation work are provided in Appendix A. 4.3 Soil Sampling Soil samples were collected from the sidewalls and bottom of the excavation, as feasible, to determine the levels of residual petroleum hydrocarbon contamination remaining in place (Figure 4). The soil samples were collected by directing the trackhoe operator to dig in a particular location. The soil samples were then obtained from the teeth of the trackhoe bucket, placed in laboratory-supplied, glass jars, appropriately labeled, placed on ice, and transported to the laboratory for analysis. The samples were collected by a State- certified soil and groundwater sampler. A total of six soil samples were obtained from the floor of the excavation and below the two dispensers during the approved UST closure sampling. Tank closure sampling locations were agreed upon and approved by an on-site DERR inspector. A total of eight random grab soil samples were acquired from the stockpiled soil removed from the excavation for laboratory analysis. These were in addition to PID screening samples which were not analyzed. The stockpile samples were labeled SP-01 through SP-8. A total of ten confirmation samples were acquired from the floor and sidewalls of the excavation. These samples were labeled CS-01 through CS-08 with sample depths specified. The majority of confirmation Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 5 samples were obtained from the central to eastern portions of the excavation due to the sidewall collapse event on March 6th. The soil samples were analyzed using U.S. Environmental Protection Agency (EPA) method 8260D for methyl tertiary-butyl ether (MTBE), benzene, toluene, ethylbenzene, xylenes, naphthalene (BTEXN), method 8260B/C for total petroleum hydrocarbons - gasoline range organics (TPH-GRO), and method 8015C for TPH-diesel range organics (TPH-DRO). Chain of custody documentation was maintained for all samples from the time of collection until delivered to the laboratory. 4.4 Analytical Results of Soil Sampling Ten confirmation soil samples, eight grab stockpile samples and six UST closure samples were collected and analyzed (Figure 4). Four of the tank closure samples collected from the floor of the excavation also serve as confirmation samples. Analytical results from soil sample analysis are tabulated in Table 1. Laboratory analytical reports and chain of custody documentation are included in Appendix B. All six UST closure samples, S1 through S6, were below Initial Screening Levels (ISLs). Six of the eight stockpile samples were over ISLs and two were over Tier 1. Nine of the ten confirmation samples were below ISLs. One sample (CS-01 at 13 feet) was above Tier 1. CS-01 was located on the north side bottom of the excavation. Laboratory analytical results of confirmation soil sampling (including floor samples from UST closure) indicate that the majority of hydrocarbon impacts remaining in the subsurface above the clay layer in the eastern portion of the excavation area are below applicable cleanup standards (ISLs). 5.0 Landfarming Initially the impacted soil was to be disposed at the San Juan County Landfill. Concerns about the landfill’s operating hours limiting the abatement work led to the decision of using a land farm. Sonderegger, Inc. owns a large private gravel pit south of Monticello, Utah which has been used as a land farm for other DERR projects in the past. The location is remote and suitable for land farming petroleum impacted soils. The land farm is located 43.7 miles north of the site compared to the landfill which is 10.5 mile from the site. The general contractor agreed to use his approved rates for hauling the soil to the Monticello location and providing labor and equipment for future treatment of the soil. 6.0 QUALITY ASSURANCE AND QUALITY CONTROL All soil samples collected during abatement activities were collected by a State-certified soil and groundwater sampler under the supervision of a State-certified UST Consultant. Proper sampling protocol, utilizing industry-recognized standards, was followed during the abatement activities. Soil samples were retained in laboratory-supplied containers and placed on ice until relinquished to the laboratory. The analytical laboratory utilized is certified by the State for the analyses performed and have quality assurance / quality control procedures in place to ensure the accuracy of the analytical data provided. Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 6 7.0 CONCLUSIONS AND RECOMMENDATIONS The following summary of events and conclusions are based on field observations, and the soil analytical results obtained during abatement activities: • On September 18, 2023 a release was reported based on a failed automatic tank gauging (ATG) test. The release was confirmed by a certified tank tester and the leaking premium gasoline UST compartment was emptied of fuel. The regular gasoline UST compartment remained in service. • In February of 2024 a subsurface investigation was performed resulting in the installation of four monitoring wells to depths of approximately 25 feet. Approximately 0.65 feet of free product (gasoline) was detected in groundwater at a depth of 19.3 feet in MW-3. • In order to minimize down time for the fueling station the abatement plan was scheduled the week prior to the arrival of a new replacement UST. On March 6th, 2024 the entire UST system was removed and on March 13th, 2024 the new tank arrived and installation began. • Excavation of impacted soils commenced during the UST removal on March 6th, 2024. Excavation activities were severely limited by the proximity of the canopy structure to the south and overhead power lines and utilities to the north. • Between March 6th and March 11th approximately 862 tons of impacted soil was excavated and hauled to a land farm location south of Monticello, Utah. To the extent possible, lesser impacted soil (overburden) was segregated and hauled to a gravel pit a few miles from Bluff. • Soil sampling was performed prior to and during the UST removal and during abatement activities. Sampling was limited in the west portion of the excavation due to collapsing sidewalls. Floor samples were acquired throughout the length (east-west) of the excavation and from the sidewalls of the east portion. • Analytical results from soil samples acquired indicate that six of seven floor samples (13-14 feet deep) were below ISLs and all seven sidewall samples (8-12 feet deep), taken from the central and east portions of the excavation, were below ISLs. • Data from the subsurface investigation (Feb 2024) identified a substantial clay layer at 13-15 feet which partially inhibited downward migration of impacts to the groundwater at 19-20 feet. However, groundwater impacts were documented in the investigation suggesting the clay layer was permeated. UEC recommends additional investigation and monitoring well installation. Additional soil data around the west portion of the former excavation in needed. Monitoring wells and extraction wells should be installed in locations which will delineate groundwater impacts and provide treatment points to remove free product. Newly installed 4-inch raceways inside the tank excavation should be utilized for well installation. This should be followed by a high vacuum extraction event to remove free product from the groundwater and vapor phase hydrocarbons from the subsurface. Abatement Report 2024 K & C Trading Post Facility ID 5000084, Release Site OIV Underwood Environmental Consulting, Inc. 7 8.0 LIMITATIONS Our services consist of professional opinions from a State-certified consultant, made in general accordance with locally accepted environmental practices at the time of execution. Environmental samples are obtained from specific locations, utilizing methodologies consistent with Utah Department of Environmental Quality regulations. UEC makes no guarantee; either expressed or implied that the analytical results accurately represent subsurface conditions throughout the entire site. REFERENCES CITED DERR, 2005 Utah LUST Program Screening Levels for Soil and Groundwater: Utah Division of Environmental Response and Remediation, Salt Lake City, Utah, November 1, 2005. UEC, 2024 Initial Subsurface Investigation Report, K & C Trading Post (Sinclair), 161 East Main Street, Bluff, Utah, Facility ID #5000084, Release Site OIV: Underwood Environmental Consulting, Inc., Park City, Utah, April 5, 2024. UEC, 2024 Petroleum Storage Tank Permanent Closure Notice – K & C Trading Post (Sinclair), 161 East Main Street, Bluff, Utah, Facility ID #5000084: Underwood Environmental Consulting, Inc., Park City, Utah, March 22, 2024. DERR, 1996 No Further Action Letter – LUST site EJHB, K and C Store, Hwy 191, Bluff, Utah, Facility ID #5000084, February 8, 1996 K & C Trading Post (Sinclair) 161 E Main Street Bluff, Utah Facility ID # 5000084 Release Site OIV Figure 1 AREA TOPO MAP SITE UST System K & C Trading Post 161 East Main Street Bluff, Utah Facility ID 5000084 Release OIVN FIGURE 2Site Vicinity Map LEGEND approx. scale in feet one inch ~ 30 feet 00 3015 K & C Trading Post (Sinclair) 161 E Main Street Bluff, Utah Facility ID # 5000084 Release Site OIV NORTH Overhead Power Artesian Well Landscape Gravel Gravel Asphalt Asphalt Asphalt Asphalt W W W W WW W W W W W WWWW C C C C C C C C C C CCCCCC w w wSDSDSDSDW W W ? ? ? Well #1 Well #2 Diesel AST K & C Store Canopy Concrete Pad Dispensers 15,000 gal UST U/L Prem Sign Sign Hotel Recapture Lodge P Water Line / MeterW (Utility Locations Approximate) Underground Power Storm Drain CommunicationsC 2-in Monitoring Well Soil Boring FIGURE 3 SITE MAP MW-1 MW-2 SB-1 MW-3 MW-4 SD Former UST HWY 191 LEGEND approx. scale in feet one inch ~ 30 feet 00 3015 K & C Trading Post (Sinclair) 161 E Main Street Bluff, Utah Facility ID # 5000084 Release Site OIV NORTH Overhead Power Artesian Well Landscape Gravel Gravel Asphalt Asphalt Asphalt W W W W WW W W W W W WWWW C C C C C C C C C C CC CCCCC w w wSDSDSDSDW W W ? ? ? Diesel AST K & C Store Canopy Concrete Pad Sign Sign Hotel Recapture Lodge Water Line / MeterW (Utility Locations Approximate) P Underground Power Storm DrainSD CommunicationsC 2-in Monitoring Well FIGURE 4 Underground Utilities Soil Abatement March 2024 s s s s s s s s s s s s s s MW-1 MW-2 MW-3 MW-4 Former UST HWY 191 CS-01 @ 8 ft CS-01 @ 13 ft CS-02 @ 10 ft CS-02 @ 13 ft CS-03 Floor @ 13 ft CS-5 @ 11 ft CS-4 @ 11 ft CS-6 @ 11 ft S4 @ 13 ft S6 @ 3 ft S5 @ 3 ft CS-08 @ 10 ft S1 @ 13 ft S2 @ 13 ft S3 @ 13 ft CS-07 @ 10 ft Soil Boring SB-1 Excavation Sample Locations Excavation Extents Soil Abatement Report K C Trading Post (Sinclair) 161 East Main St., Bluff, UT Facility ID #5000084, Release Site OIV Date Ethyl-Total Naphtha-TPH TPH Sample Number Collected MTBE Benzene Toluene benzene Xylenes lene GRO DRO (mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg) MW-1 @ 3-5 ft 2/16/2024 <0.01 <0.01 0.05 <0.03 0.18 <0.03 <0.283 <59 MW-1 @ 11-12 ft 2/16/2024 <0.01 1.81 15.1 5.19 20.2 0.42 102 99 MW-1 @ 13-15 ft 2/16/2024 <0.12 0.05 0.81 0.39 1.59 0.08 10 <63 MW-1 @ 17-19 ft 2/16/2024 <0.009 <0.009 <0.02 <0.02 0.03 0.02 0.237 <53 MW-2 @ 5-7 ft 2/15/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.235 <59 MW-2 @ 12-13 ft 2/15/2024 <0.009 <0.009 <0.02 <0.02 <0.02 <0.02 0.235 <65 MW-2 @ 18-19 ft 2/15/2024 <0.009 <0.009 <0.02 <0.02 <0.02 <0.02 <0.224 <54 MW-2 @ 21-22 ft 2/15/2024 <0.009 <0.009 <0.02 <0.02 <0.02 <0.02 <0.213 <61 MW-3 @ 5-7 ft 2/15/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 0.28 <56 MW-3 @ 10-12 ft 2/15/2024 <0.01 1.94 2.47 1.48 6.33 0.13 21.6 <69 MW-3 @ 15-16 ft 2/15/2024 <0.009 <0.009 <0.02 <0.02 <0.02 <0.02 <0.236 <50 MW-3 @ 19-20 ft 2/15/2024 <0.13 0.74 4.65 0.55 2.30 <0.32 8.23 <65 MW-3 @ 20-21 ft 2/15/2024 <0.01 <0.01 0.15 0.06 0.26 <0.03 2.90 <59 MW-4 @ 5-7 ft 2/16/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.301 <61 MW-4 @ 10-12 ft 2/16/2024 <0.01 <0.01 <0.02 <0.02 <0.02 <0.02 <0.248 <67 MW-4 @ 19-20 ft 2/16/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.258 <55 MW-4 @ 22-23 ft 2/16/2024 <0.009 <0.009 <0.02 <0.02 <0.02 <0.02 <0.228 <57 SB-1 @ 18-20 ft 2/16/2024 <0.006 <0.006 0.04 0.01 0.06 0.01 0.327 <78 0.3 0.2 9 5 142 51 150 500 0.3 0.9 25 23 142 51 1,500 5,000 TABLE 1 SOIL SAMPLE ANALYTICAL RESULTS Initial Subsurface Investigation - February 2024 Initial Screening Level (1) Tier 1 Screening Criteria (1) Underwood Environmental Consulting, Inc. Soil Abatement Report K C Trading Post (Sinclair) 161 East Main St., Bluff, UT Facility ID #5000084, Release Site OIV Date Ethyl-Total Naphtha-TPH TPH Sample Number Collected MTBE Benzene Toluene benzene Xylenes lene GRO DRO (mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg) TABLE 1 SOIL SAMPLE ANALYTICAL RESULTS S1 @ 13 ft 3/6/2024 <0.01 0.09 0.25 0.05 0.20 <0.03 0.869 <64 S2 @ 13 ft 3/6/2024 <0.01 0.09 1.12 0.41 1.80 0.18 12.3 <65 S3 @ 13 ft 3/6/2024 <0.1 0.13 0.58 0.08 0.31 0.03 1.54 <66 S4 @ 13 ft 3/6/2024 <0.009 0.08 0.37 0.05 0.23 0.05 0.773 <66 S5 @ 3 ft 3/5/2024 <0.01 <0.01 <0.02 <0.02 <0.02 <0.02 <0.247 69 S6 @ 3 ft 3/5/2024 <0.009 <0.009 <0.02 <0.02 <0.02 <0.02 <0.217 79 SP-01 3/6/2024 <0.11 <0.11 6.38 5.23 24.5 1.82 255 116 SP-02 3/6/2024 <0.11 1.16 38.7 14.9 77 2.89 602 199 SP-03 3/7/2024 <0.11 0.28 14.0 9.29 40.8 3.35 480 250 SP-04 3/7/2024 <0.11 1.18 62.1 33.8 142 7.06 1020 520 SP-5 3/11/2024 <0.11 0.78 27.4 15.2 63.0 3.01 560 253 SP-6 3/11/2024 <0.01 0.03 1.19 0.68 3.04 0.19 11.9 <65 SP-7 3/11/2024 <0.12 <0.12 4.67 4.78 21.1 1.82 189 150 SP-8 3/11/2024 <0.11 <0.11 <0.28 0.37 2.64 0.84 24.3 75 0.3 0.2 9 5 142 51 150 500 0.3 0.9 25 23 142 51 1,500 5,000 UST Closure Samples - March 2024 Abatement Stockpile Samples - March 2024 Initial Screening Level (1) Tier 1 Screening Criteria (1) Underwood Environmental Consulting, Inc. Soil Abatement Report K C Trading Post (Sinclair) 161 East Main St., Bluff, UT Facility ID #5000084, Release Site OIV Date Ethyl-Total Naphtha-TPH TPH Sample Number Collected MTBE Benzene Toluene benzene Xylenes lene GRO DRO (mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg)(mg/kg) TABLE 1 SOIL SAMPLE ANALYTICAL RESULTS CS-01 @ 8 ft 3/11/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.294 <62 CS-01 @ 13 ft 3/11/2024 <0.13 1.40 20.7 8.46 32.4 1.23 295 596 CS-02 @ 10 ft 3/11/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.273 <60 CS-02 @ 13 ft 3/11/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.269 <64 CS-03 Floor @ 13 ft 3/11/2024 <0.01 <0.01 <0.02 <0.02 <0.02 <0.02 <0.243 <65 CS-04 @ 11 ft 3/11/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.277 <59 CS-05 @ 12 ft 3/11/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.268 <59 CS-06 @ 11 ft 3/11/2024 <0.12 <0.12 <0.31 <0.31 <0.31 <0.31 <3.10 <62 CS-07 @ 10 ft 3/12/2024 <0.12 <0.12 <0.29 <0.29 <0.29 <0.29 <2.91 <58 CS-08 @ 10 ft 3/12/2024 <0.01 <0.01 <0.03 <0.03 <0.03 <0.03 <0.281 <59 0.3 0.2 9 5 142 51 150 500 0.3 0.9 25 23 142 51 1,500 5,000 Notes:MTBE = Methyl Tertiary-Butyl Ether mg/kg = Milligrams per Kilogram TPH-GRO =Total Petroleum Hydrocarbons - Gasoline Range Organics < Indicates below given detection limit TPH-DRO =Total Petroleum Hydrocarbons - Diesel Range Organics (1) DERR, 2005 Bold values are above Initial Screening Levels Highlighted,bold , values are above Tier 1 Screening Criteria Tier 1 Screening Criteria (1) Initial Screening Level (1) Abatement Confirmation Samples - March 2024 Underwood Environmental Consulting, Inc. Initial Subsurface Investigation Report K and C Trading Post 161 East Main St., Bluff, UT Facility ID 5000084, Release Site OIV WELL/DATE DTW FPT GW Elev.MTBE Benzene Toluene Ethyl- benzene Xylenes Naphth- alene TPH (GRO) TPH (DRO) ELEV.(feet)(feet)(feet)(mg/L)(mg/L)(mg/L)(mg/L)(mg/L)(mg/L)(mg/L)(mg/L) MW-1 02/24/24 19.56 80.44 <0.005 0.627 3.58 0.491 1.73 0.027 8.47 <1.0 100.00 MW-2 02/24/24 19.17 80.36 <0.005 0.291 0.013 0.073 <0.012 <0.012 0.665 <1.0 99.53 MW-3 02/24/24 19.99 0.65 80.38 99.89 MW-4 02/24/24 18.58 80.34 <0.005 0.033 0.051 <0.012 0.022 <0.012 <0.125 <1.0 98.92 Initial Screening Levels (1)0.2 0.005 1 0.7 10 0.7 1 1 Tier 1 Screening Criteria (1)0.2 0.3 3 4 10 0.7 10 10 Notes:Arbitrary datum of 100.00 feet established on site.MTBE = Methyl Tertiary Butyl Ether DTW = Depth to Water TPH (GRO) = Total Petroleum Hydrocarbons - Gasoline Range Organics FPT = Free Product Thickness TPH (DRO) = Total Petroleum Hydrocarbons - Diesel Range Organics GW Elev. = Groundwater Elevation < Indicates below given detection limit. GW Elev. Correction = (Well Elev.-DTW)+(0.75*FPT).Bold values are above Initial Screening Levels. (1) DERR, 2005 Highlighted,bold , values are above Tier 1 Screening Criteria. TABLE 2 GROUNDWATER MONITORING DATA Not Sampled due to Free Product Underwood Environmental Consulting, Inc. APPENDIX A PHOTOGRAPHS K & C Trading Post (Sinclair) 161 East Main Street Bluff, Utah Facility ID# 5000084 Release OIV Well #1 Well #2 Photo Documentation - March 2024 Abatement Pg 1 Project Site Looking Southwest Former UST removed March 6, 2024 March 6th Excavation looking east March 6th looking south at canopy footing K & C Trading Post (Sinclair) 161 East Main Street Bluff, Utah Facility ID# 5000084 Release OIV Photo Documentation - March 2024 Abatement Pg 2 March 7th Emergency Backfill of west portion of exvavation Canopy Support System looking northwest March 6th limited excavation access looking east K & C Trading Post (Sinclair) 161 East Main Street Bluff, Utah Facility ID# 5000084 Release OIV Photo Documentation - March 2024 Abatement Pg 3 March 11th Excavation looking west March 11th Excavation looking east K & C Trading Post (Sinclair) 161 East Main Street Bluff, Utah Facility ID# 5000084 Release OIV Photo Documentation - March 2024 Abatement Pg 4 March 13th UST installation looking west 4-inch PVC well screen for future well install K & C Trading Post (Sinclair) 161 East Main Street Bluff, Utah Facility ID# 5000084 Release OIV Photo Documentation - March 2024 Abatement Pg 5 April 1st 2024 resurfacing and UST install complete April 1st Looking South APPENDIX B Laboratory Analytical Reports And Chain of Custody Documentation The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Underwood Environmental Consulting Attn: Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 Work Order: 24C0610 Project: K+C Bluff 3/15/2024 Approved By: Mark Broadhead, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: S1 @ 13' Lab ID: 24C0610-01Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 11:13 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800077.6Total Solids MBTEXn mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030B0.09Benzene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.05Ethylbenzene mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.25Toluene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.20Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/240.273 EPA 8260B/C 5035A/[CALC]0.869Gasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2464EPA 8015 CNDDiesel Range Organics Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 2 of 11Page 2 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: USC - 1 @ 13' Lab ID: 24C0610-02Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 11:13 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic -3/11/243/11/24ASTM D2487-ModCHUnited Soil Classification [USC] Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 3 of 11Page 3 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: S2 @ 13' Lab ID: 24C0610-03Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 11:10 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800076.8Total Solids MBTEXn mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030B0.09Benzene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.41Ethylbenzene mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.18Naphthalene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B1.12Toluene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B1.80Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/240.322 EPA 8260B/C 5035A/[CALC]12.3Gasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2465EPA 8015 CNDDiesel Range Organics Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 4 of 11Page 4 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: S3 @ 13' Lab ID: 24C0610-04Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 11:18 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800075.7Total Solids MBTEXn mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030B0.13Benzene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.08Ethylbenzene mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.03Naphthalene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.58Toluene mg/kg dry 3/11/243/11/240.03 EPA 8260D/5030B0.31Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/240.317 EPA 8260B/C 5035A/[CALC]1.54Gasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2466EPA 8015 CNDDiesel Range Organics Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 5 of 11Page 5 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: S4 @ 13' Lab ID: 24C0610-05Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 11:30 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800076.2Total Solids MBTEXn mg/kg dry 3/11/243/11/240.009 EPA 8260D/5030B0.08Benzene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030B0.05Ethylbenzene mg/kg dry 3/11/243/11/240.009 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030B0.05Naphthalene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030B0.37Toluene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030B0.23Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/240.236 EPA 8260B/C 5035A/[CALC]0.773Gasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2466EPA 8015 CNDDiesel Range Organics Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 6 of 11Page 6 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: S5 @ 3' Lab ID: 24C0610-06Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/5/24 10:26 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800082.1Total Solids MBTEXn mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDEthylbenzene mg/kg dry 3/11/243/11/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDToluene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/11/243/11/240.247 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2461EPA 8015 C69Diesel Range Organics Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 7 of 11Page 7 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: USC - 2 @ 3' Lab ID: 24C0610-07Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/5/24 10:26 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic -3/11/243/11/24ASTM D2487-ModCLUnited Soil Classification [USC] Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 8 of 11Page 8 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Sample ID: S6 @ 3' Lab ID: 24C0610-08Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/5/24 10:39 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800081.0Total Solids MBTEXn mg/kg dry 3/11/243/11/240.009 EPA 8260D/5030BNDBenzene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDEthylbenzene mg/kg dry 3/11/243/11/240.009 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDToluene mg/kg dry 3/11/243/11/240.02 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/11/243/11/240.217 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2462EPA 8015 C79Diesel Range Organics Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 9 of 11Page 9 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-TR 3/11/24 9:20 @ 0.7 °C 3/15/2024 K+C Bluff Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit (MRL). 1 mg/L = one milligram per liter or 1 mg/kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/kg = one nanogram per kilogram = 1 part per trillion. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Project Name: K+C Bluff CtF WO#: 24C0610 www.ChemtechFord.com Page 10 of 11Page 10 of 11 Page 11 of 11 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Underwood Environmental Consulting Attn: Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 Work Order: 24C0609 Project: K & C Bluff 3/15/2024 Approved By: Mark Broadhead, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 7 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-02 3/11/24 9:20 @ 0.7 °C 3/15/2024 K & C Bluff Sample ID: SP-01 Lab ID: 24C0609-01Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 14:31 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800090.8Total Solids MBTEXn mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030BNDBenzene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B5.23Ethylbenzene mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B1.82Naphthalene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B6.38Toluene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B24.5Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/242.75 EPA 8260B/C 5035A/[CALC]255Gasoline Range Organics Diesel Range mg/kg dry 3/12/243/12/2455EPA 8015 C116Diesel Range Organics Project Name: K & C Bluff CtF WO#: 24C0609 www.ChemtechFord.com Page 2 of 7Page 2 of 7 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-02 3/11/24 9:20 @ 0.7 °C 3/15/2024 K & C Bluff Sample ID: SP-02 Lab ID: 24C0609-02Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/6/24 15:10 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800088.1Total Solids MBTEXn mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030B1.16Benzene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B14.9Ethylbenzene mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B2.89Naphthalene mg/kg dry 3/11/243/11/241.42 EPA 8260D/5030B38.7Toluene mg/kg dry 3/11/243/11/241.42 EPA 8260D/5030B77.0Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/242.84 EPA 8260B/C 5035A/[CALC]602Gasoline Range Organics Diesel Range mg/kg dry 3/12/243/12/2457EPA 8015 C199Diesel Range Organics Project Name: K & C Bluff CtF WO#: 24C0609 www.ChemtechFord.com Page 3 of 7Page 3 of 7 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-02 3/11/24 9:20 @ 0.7 °C 3/15/2024 K & C Bluff Sample ID: SP-03 Lab ID: 24C0609-03Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/7/24 10:26 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800089.9Total Solids MBTEXn mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030B0.28Benzene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B9.29Ethylbenzene mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B3.35Naphthalene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B14.0Toluene mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B40.8Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/242.78 EPA 8260B/C 5035A/[CALC]480Gasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2456EPA 8015 C250Diesel Range Organics Project Name: K & C Bluff CtF WO#: 24C0609 www.ChemtechFord.com Page 4 of 7Page 4 of 7 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-02 3/11/24 9:20 @ 0.7 °C 3/15/2024 K & C Bluff Sample ID: SP-04 Lab ID: 24C0609-04Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/7/24 11:58 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/13/243/12/240.1 CTF800088.6Total Solids MBTEXn mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030B1.18Benzene mg/kg dry 3/11/243/11/242.82 EPA 8260D/5030B33.8Ethylbenzene mg/kg dry 3/11/243/11/240.11 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/11/243/11/240.28 EPA 8260D/5030B7.06Naphthalene mg/kg dry 3/11/243/11/242.82 EPA 8260D/5030B62.1Toluene mg/kg dry 3/11/243/11/242.82 EPA 8260D/5030B142Xylenes, total Gasoline Range mg/kg dry 3/11/243/11/242.82 EPA 8260B/C 5035A/[CALC]1020Gasoline Range Organics Diesel Range mg/kg dry 3/13/243/12/2456EPA 8015 C520Diesel Range Organics Project Name: K & C Bluff CtF WO#: 24C0609 www.ChemtechFord.com Page 5 of 7Page 5 of 7 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV-02 3/11/24 9:20 @ 0.7 °C 3/15/2024 K & C Bluff Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit (MRL). 1 mg/L = one milligram per liter or 1 mg/kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/kg = one nanogram per kilogram = 1 part per trillion. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Project Name: K & C Bluff CtF WO#: 24C0609 www.ChemtechFord.com Page 6 of 7Page 6 of 7 Page 7 of 7 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Underwood Environmental Consulting Attn: Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 Work Order: 24C1166 Project: K&C Bluff 3/25/2024 Approved By: Mark Broadhead, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-01 @ 8' Lab ID: 24C1166-01Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 9:00 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800080.2Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.294 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2462EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 2 of 17Page 2 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-01 @ 13' Lab ID: 24C1166-02Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 9:10 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800078.7Total Solids MBTEXn mg/kg dry 3/20/243/20/240.13 EPA 8260D/5030B1.40Benzene mg/kg dry 3/20/243/20/240.32 EPA 8260D/5030B8.46Ethylbenzene mg/kg dry J-LOW-C3/20/243/20/240.13 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.32 EPA 8260D/5030B1.23Naphthalene mg/kg dry 3/20/243/20/240.32 EPA 8260D/5030B20.7Toluene mg/kg dry 3/20/243/20/240.32 EPA 8260D/5030B32.4Xylenes, total Gasoline Range mg/kg dry 3/20/243/20/243.18 EPA 8260B/C 5035A/[CALC]295Gasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2464EPA 8015 C596Diesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 3 of 17Page 3 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-02 @ 10' Lab ID: 24C1166-03Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 9:20 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800083.3Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.273 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2460EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 4 of 17Page 4 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-02 @ 13' Lab ID: 24C1166-04Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 9:15 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800078.2Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.269 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2464EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 5 of 17Page 5 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-03 Floor @ 13' Lab ID: 24C1166-05Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 15:10 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800077.5Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.243 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2465EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 6 of 17Page 6 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-04 @ 11' Lab ID: 24C1166-06Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 15:20 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800085.1Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.277 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2459EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 7 of 17Page 7 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-05 @ 12' Lab ID: 24C1166-07Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 15:25 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800084.9Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.268 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2459EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 8 of 17Page 8 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-06 @ 11' Lab ID: 24C1166-08Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 15:30 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800080.7Total Solids MBTEXn mg/kg dry 3/20/243/20/240.12 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.31 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.12 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.31 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.31 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.31 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/243.10 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2462EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 9 of 17Page 9 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-07 @ 10' Lab ID: 24C1166-09Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/12/24 12:30 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800085.9Total Solids MBTEXn mg/kg dry 3/20/243/20/240.12 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.29 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.12 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.29 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.29 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.29 EPA 8260D/5030B0.36Xylenes, total Gasoline Range mg/kg dry 3/20/243/20/242.91 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2458EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 10 of 17Page 10 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: CS-08 @ 10' Lab ID: 24C1166-10Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/12/24 12:35 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800084.7Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDEthylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDNaphthalene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.03 EPA 8260D/5030BNDXylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.281 EPA 8260B/C 5035A/[CALC]NDGasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2459EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 11 of 17Page 11 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: SP - 5 Lab ID: 24C1166-11Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 8:30 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800088.0Total Solids MBTEXn mg/kg dry 3/20/243/20/240.11 EPA 8260D/5030B0.78Benzene mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B15.2Ethylbenzene mg/kg dry J-LOW-C3/20/243/20/240.11 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B3.01Naphthalene mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B27.4Toluene mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B63.0Xylenes, total Gasoline Range mg/kg dry 3/20/243/20/242.84 EPA 8260B/C 5035A/[CALC]560Gasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2457EPA 8015 C253Diesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 12 of 17Page 12 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: SP - 6 Lab ID: 24C1166-12Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 10:40 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800077.0Total Solids MBTEXn mg/kg dry 3/20/243/20/240.01 EPA 8260D/5030B0.03Benzene mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030B0.68Ethylbenzene mg/kg dry J-LOW-C3/20/243/20/240.01 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030B0.19Naphthalene mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030B1.19Toluene mg/kg dry 3/20/243/20/240.02 EPA 8260D/5030B3.04Xylenes, total Gasoline Range mg/kg dry 3/20/243/20/240.250 EPA 8260B/C 5035A/[CALC]11.9Gasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2465EPA 8015 CNDDiesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 13 of 17Page 13 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: SP - 7 Lab ID: 24C1166-13Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 11:20 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800084.5Total Solids MBTEXn mg/kg dry 3/20/243/20/240.12 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.30 EPA 8260D/5030B4.78Ethylbenzene mg/kg dry J-LOW-C3/20/243/20/240.12 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.30 EPA 8260D/5030B1.82Naphthalene mg/kg dry 3/20/243/20/240.30 EPA 8260D/5030B4.67Toluene mg/kg dry 3/20/243/20/240.30 EPA 8260D/5030B21.1Xylenes, total Gasoline Range mg/kg dry 3/20/243/20/242.96 EPA 8260B/C 5035A/[CALC]189Gasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2459EPA 8015 C150Diesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 14 of 17Page 14 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Sample ID: SP - 8 Lab ID: 24C1166-14Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 3/11/24 12:53 Preparation Date/Time Sampled By: L. Earl Underwood Minimum Reporting Limit MethodResult Inorganic %3/20/243/19/240.1 CTF800089.6Total Solids MBTEXn mg/kg dry 3/20/243/20/240.11 EPA 8260D/5030BNDBenzene mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B0.37Ethylbenzene mg/kg dry J-LOW-C3/20/243/20/240.11 EPA 8260D/5030BNDMethyl tert-Butyl Ether (MTBE) mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B0.84Naphthalene mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030BNDToluene mg/kg dry 3/20/243/20/240.28 EPA 8260D/5030B2.64Xylenes, total Gasoline Range mg/kg dry 3/20/243/20/242.79 EPA 8260B/C 5035A/[CALC]24.3Gasoline Range Organics Diesel Range mg/kg dry 3/21/243/21/2456EPA 8015 C75Diesel Range Organics Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 15 of 17Page 15 of 18 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Underwood Environmental Consulting Earl Underwood 9475 North Silver Creek Road Park City, UT 84098 PO#: Receipt: Date Reported: Project Name: OIV - 02 3/18/24 13:07 @ 2.1 °C 3/25/2024 K&C Bluff Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit (MRL). 1 mg/L = one milligram per liter or 1 mg/kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/kg = one nanogram per kilogram = 1 part per trillion. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Flag Descriptions J-LOW-C = Estimated low due to low recovery of CCV Project Name: K&C Bluff CtF WO#: 24C1166 www.ChemtechFord.com Page 16 of 17Page 16 of 18 Page 17 of 18 Page 18 of 18