HomeMy WebLinkAboutDERR-2024-006453G lil ll rril Iil lllllllilllillt]illlililt ilr ilfl l|| DERR_2008_000461 Document Date. 2l2Ol2OOg Utah Department of Environmental Quality UST Release Detection Inspection to 1200301 Iof'z Ownersh of Tanks Location STATE FUEL NETWORK WEBER STATE UNIVERSITY Address ATTN MARGARET CHAMBERS Address 3750 HARBISON BLVD SALT LAKE CIry UT 84114 OGDEN State UT 84408 STEVE 619-7232 DAVID MAXSON Phone 626-7945 on at I 2 Tank lnstallation Date 12nt1988 121711988 4000 2000 Dies€l Gasoline rn use Yes No Yes No Yes No Yes No tn Yes No Yes No Material of construction of Pressurized S _.0 bucket is etc.Yes O,No Yes No Yes No Yes No Yes No of Overlill Prevention device }e \o Overfill alarm or IS located so driver can hear or see and is identified.Yes No d#D and three Yes No N/A proper at every Yes No N/A Dates of last three checks: lndicate the corrosion method used for each UST. Number each Give results for the most recent cathodic test. Corr. Protect. Method Sacrificial Anode lnstant Off 1 2 Tanks 3 4 5 6 1 2 c. Lines 3 4 5 6 1 2 Tank Flex 3 4 5 6 U FR o N on Disp. Flex TI o/o Distribution: White- DERR,lnsp€ctor, Pink- Facility/Owner Ldchecko807.doc TANK LEAK DETECTION ATG PIPING LEAK DETECTION ALD LTT tr piping qualifies as Sate Suction, Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one check valve (under pump), and has proper slope of piping. lf all these criteria are met, no leak detection is required on the piping. Piping method(s) used. Pressurized piping must have an Automatic Line Leak Detector and E Automatic Line Leak Detector. Type (Mechanical, Electronic, Othefl: Manulacturer and model of each leak detector: Date ol lasl leak detector performance lest2 -Lo'1sr7 Flesults: lndicate type of test: Simulated Lea(, 3 gph, .2 gph, .1 ggh (3, .2,..1- electronic LLD only) Testername: ryW?XW cert.Number UT e r L/ Test Method E Line tishtness testins, o^rff, ,#!g,!,j:ef/Z#L ? 'La - zrr,zFlesults: tr Same as above Tester name: " <k -. /*u*tn Cert. Number UT U Monthly monitoring. lndicate the method used: Show E' .z OPH Monthly Testing tr SIR for tor the last Oi z Test Method E lnterstitial Monitoring. Type ol lM Documentation: E GW Monitoring E Vapor Monitoring lndicale Fail or No uous TestiATG Shutdown Testi Faci e?-ofa Utah UST Program Automatic Tank Gau lnterstitial Monitorin lD 1200301 Manufacturer, name and model of svstem: \ ,., ,,, , i i,', ' Circle Yes or No lor each question. ln the |a9lQQlurnlelpla!!-91.djdg bv tank anv exceotions to the answers qiven in the first column. Tvoe of lM Documenlation used:Tvoe of Secondarv Containment usedIM G9 *o dtc)u Records on site document that the system is properly installed, calibrated, operated, and maintained (system and tank setup reports, maintenance records). Written documentation ol calibration, maintenance, and repair is kept lor at least one year after work is completed. No@/frTGllM ATG console or other equipment used to take readings and perform tests is adeouate. accessible, and operational. No6eKte w Documentation ol valid testing or monitoring is available for the last 12 months. Show results in table below. lf not in center, show tilt lactors from the setup report. Tilt: #1 #2 #3 #4 Re No@The probe is located at the cenler ol the tank. @, r'lo Third Party Minimum Level:Rc -The tank was lilled to at least the minimum level required to ensure a valid leak test, and lhe lank size is within the allowe! upper and lower size limits. Yes NoIMSystem is capable ol detecting a release of regulated substances lrom any portion of the primary tank/piping within one monlh of release ndicatePass,Fail,lnvalid,orNoBesultS,oreachmonth.ForATGtests,showthe highest product level tested for each month. 8lr,n o/u'n 1 10lo,a 11lD_1 1214ln-,tlJ t)1 6l o,7l c.rlMo/Yr 1l ,>',ao.1 3l ,r. Forn /r,..A-4ts /qc1 /b"ty'o<"2.,,/)or.#1 l)o..f,ts lt,aI /2-t/7n,/n45 /o*PoplA,/ur,far r f- q'#7 /\,,./ort iD, -rn # /.t"/)eo t 121--6ln-7l ,,--.-8/o/"'o-,10t 11t ..2t 3lo-4l o.5l ,,-Mo/Yr Po.t Aos,An<&qsgi.t s Pn..,.[4, s Pot.Poso,#l Po*0oqc /o"" /4,'Ars AE,/*t ft>t -4*s/o.,hr"{7.-.{1".#7 Prt s lesr, # # COMMENTS Tank 1 Tank 2 Tank 3 Tank 4 MEO Y(y E o @ E o ftt.o>qJ,,L /AaO>ta Pqt,P^r,./ s1 3.2.1 s1 3.2.1 sI 3.2.1sL3.2.l h,,lonilorinolt B,'1, l r-ln .-^ - L 0 n^^-l/,^ ..:t/^ o l--4^^^- ..^nJ. /1r-A WEBER STATE UNIVERSIry 3750 HARRISON BLVD OGDEN UT 84408 Facility lD: 1200301 Tank # Capacity Substance Compliance FinancialAssuranceMech. 2008 UST CERTIFICATE OF COMPLIANCE STATE FUEL NETWORK ATTN MARGARET CHAMBERS SALT LAKE CITY UT 84114 't't52 LOCATION OF TANKS:ISSUED TO: This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federa! UST regulataons. Possesslon of thas certiticate does not signify coverage under the Utah PST Fund. cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY , \- \/ APPLIED ENVIRONMENTAL SERVICES. L.C. PO BOX 182 ROy, UTAH 84067 (S01) 540-9258 TEI 5OOO NON VO UMETRIC, TEI 4OOO VOLUMETRIC.I ULLAGE. TEI LT3 These systems meet all requirements set forth by USEPA 40 CFR and has received third party certification PRECISION TANK & LINE TEST RESULTS SUIVIVIARY INVOICE ADDRESS: STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 TANK LOCATION: WEBER STATE UNIVERSITY MOTOR POOL OGDEN, UTAH TIME END: 14:30 WORK ORDER # 07018 pEQ tD# 1200301 TECHNICIAN: SM TECH #94027 STATETECH# UT 0121 GROUNDWATER DEPTH: N/A DW TKS DATE: 2-20-2007 TIME START: 12:30 TANK TANK PRODUCT TANK VENT PRODUCT LINE LEAK WATER IN PUMP TYPE TANK MATERIALCAPITYLINE DETECTOR TA NK 1. 2. 3. 4. 5. b. 4000 2000 R/UL DSL PASS PASS PASS PASS PASS PASS PASS PASS 0.0" 4.0" PRESS PRESS DWF DWF PRODUCT LINES TESTED AT50 PSI FOR 15 MIN LrNE RATES (GPH) 1. R/uL -.ooo 4. 2. DSL -.ooo 5. 3. 6. LINE LEAK DETECTOR TYPE & SIMULATED LEAK RATE M = MECHANICAL E= ELECTRONIC #= (cpH) RATE 1. 2. 3. 4. 5. 6. TEST METHODS USED FOR THIS LOCATION TEI LT3 LINE TEST ADDITIONAL INFORMATION All tests were performed according to manufacturer protocol, and within the common tightness testing, these results cannot be guaranteed. There are no practices of the industry. However due to the variables of warranties expressed, written or implied. Digitally signed by Steven B. tr/artin cn=Steven B. Martin, o=AES, c=US Date: 2007.02.22 07:08:23 -07'00' Reason: <none> M M 3 3 X CERTIFIED TECH ICIAN SIGNATURE: -]l_Xl -il rerraNxuLuceresrl---l F F DATE: 2-20-2007 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UT 84141-1152 (801)61e-7232 a GAS STATION INSPECTION REPORT Facility Name and Site Address WEBER STATE UNIVERSITY TVOTOR POOL Facility lD#1 200301 OGDEN, UTAH Purpose: Regular____- Reinspection__--. Complaints- Annual lnspection -X--- ACTION TAKEN 1-2 METER BROKE Storage tanks properly labeled Fill caps and underground storage covers-good Fuel filters on pumps Octane posted on PUmPS Security seals intact Dispenser ContinuitY Test MOTOR FUEL PRODUCTS USED FOR INSPECTION Regular____ gallons Unleaded RegularlZ- gallons Unleaded Plus---- gallons U n leaded Premium----- gallons Diesel__5_ gallons Product was returned to fuel storage tanks. Date:2-20-2007 Eo a:, ! Eo ()o ot !oiE .U' Ga Eo aoF Lo -o E fz XPumps tested for calibrationX XXWater tests/Fuel storage X X X X X X lnspection Remarks:R/UL METER FREEZES UP Steven B. Martin UT0121 Applied Environmental Services L.C Received by lnspected by E M S R/UL 4K fs DLS 2K 9"D 1" WEBER STATE MOTOR POOL 3750 HARRISON OGDEN, UT MOTOR POOL SHED APPROXIMATLY 5OO FEET WEST OF HERE tr o o I/[{ilRo * ROAD t:] ) ) owner Name STATE FUEL NETWORK Location Name wEBER STATE UNIVERSITY Address ATTN STEVE SALTZGIVER trddlsss 3750 HARRISON BLVD citvSALT LAKE CtrY StateUT Zip 84114 citv oGDEN state ur zip84408 626-7945DAVIDMAXSON1Phone(801) 619-7232CANNINGContact sTEvE Number of tanks at the Tank lnstallation Date 12nt1988 1?,7t1988 Capacitv of Tank (in qallons)2000 4000 Tank siphoned or compartmented Substance Stored Yes No Yes NoTank is in use.G"") uo r6J ruo Yes No Yes No Date last used/deoth of product v6i) ruo Yes No Yes No Yes No Yes NoCurrent year tank tags are in place.No.fJ Fiberolass BeinlorceMaterial of construction of tanks Fiberglass Reintorce Material of construction of piping Flexible Plastic Flexible Plastic Pioino tvpe Pressurized Pressurized Tvoe ol Soill Prevention device 6n 6u-tu-or ---+Soill bucket is clean. intact etc.(fi"r) r.ro .{"") No Yes No Yes No Yes No Yes No A4D lt6()Type of Overfill Prevention device Yes ruo .tG-Overfill alarm (audible or visible) is properly located so delivery driver can hear or see it, and is clearly identified Containment sumps are sealed, free from water, product, etc. 6^Yes NoThe results of the last two cathodic protection tests are available (within six monlhs of installatio v UTCathodic Protection Testinq. Date of last test:Tester Yes *o -@ I Dates of last three checks:lmpressed Current System is checked for proper operation at least every 60 davs and the results of the last three checks are available. Corr. Protect. Method Sacrificial Anode 1 rl M 2 A( A^ 3 4 5 Tanks 6 1 NM 2 NAA 3 4 5 Lines 6 1 1O- 2 Te- sar B] Cunent off { 3 I Commentr 4 5 Tank Flex 6 10- I I rn Method MethodOK? Y N by: I I t I .Pnfuno<(r-r.i inspected this facilitv on +-1-D'7 n e4-bl Fsio*,r*\a.d-, ^Q"*-rrr)e<- Disp. Flex lndicate below the corrosion protection method in place for each UST system component. ldentify each dispenser by pump numbe(s). Show readings for the most recent cathodic test. I o/o Sion"trr", A/rli- O A) ( rz. 6 Facilitv lD 1200301Utal iST Proqram Release Detecii-on I nspe-ction Checkl ist Paqe / ol 3 Location of Tanks fl 'benn Us6onrv Comolete for each tank lf the fac v has more than l l z r%I) ruo N/A E) d TANK LEAK DETECTION Tank method used:Shutdown ATG Continuous lnterstitial Veeder Root IM Containment used: TLS.35O of Manulacturer name and model of (Drr,,r Records on site document that the system is properly installed, calibrated, operated, and maintained (system and tank setup reports, maintenance records). Written documentation of calibration, maintenance, and repair is kept for at least one vear after work is completed. ,@ *o Attrr tu ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational.Yes No NoIM Documentation of valid testing or monitoring is available for the last 12 months. Show results in table below. The probe is located at the center of the tank.6>"lf not in center, show tilt factors Tilt #1 #2 #3 #4 #5 #6 from the setuo reoort.qa The tank was filled to at least the minimum level required to ensure a valid leak test. and the tank size is within the allowed upper and lower size limits.@*o Third Partv Minimum Level: IM qoo 5t 0a any Molt/r 1t 2l 6t oG System is capable of detecting a releass regulated substances the within one month of release stD 101 1 1 Yes ---2#l l-#2 I -= # # #I , Tank 4 Tank 5Tank 3 Tank 6 1@e o @e o MEO MEO MEO MEO zu RJ P P @.r.,@r,s1 3.2.1 s1 3.2.1 sL3.2.1 s1 3.2.1 PIPING LEAK DETECTION ALD LTTD Piping qualifies as Safe Suction. Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one check valve (under pump), and has proper slope of piping. lf all these criteria are met, no leak detection is required on the piping. Ooslwe ukxrN Date of last leak detector performance test:?-tr-0 C Cert. Number UT lZl Test Method Automatic Line Leak Detector Type(Mechanical, Eleckonic, Other) Manufacturer and model of each leak detector: Piping method(s) used. Pressurized piplng must have an Leak and one other form of leak detection. Tester name: Results: lndicate type ol test: Simulated Leak, 3 gph, .2 gph, .1 gph (3, .2, .1- electronic LLD only) Cert. Number UT Test Method: Results: ry.Line tightness testing. Date of last line tightness test: flsame as above ' Tester name: D Monthly monitoring. tr .2 GPH Monthly Testing tr lnterstitial Monitoring. Type of lM Documentation: lndicate the method used: tr SIR tr GW Monitoring tr Vapor Monitoring Show results of monthly monitoring for plplns for the last 12 months. lndicate Pass, Fail, lnvalid, or No Results lor each month. Mol/r 1t 2l 3l 4t 5l 6t 8/9t 101 11t 1A # # # # # #- COMMENTS Ldal9iro307.doc Program lnterstitial Monitori 1200301 Automatic Tank Utah of Show results of monitoring for each tank tor the last 12 months. lndicate Pass, Fail, lnvalid, oi'l\lo Results for each month. For ATG tests, show the 3ta7 Ttot>8l na, 21 Send To Printer Back TerraSeruer Change to 11x17 Print Size S' r Grid Lines Change to Portrait South States 0'.,'25m0425yd Image courtesy of the U.S. Geological Suruey O 2004 Microsoft Corporation. Terms of Use Privacy Statement Lt JNT F\a\ft L G€+; I \ I T. L .) , I Li f, I- rru n v ) ,&' .\, .$i" lr , at'"t ,. , ,t,L-, I F E I ,t} +,;* Z a I 1' 1 uI \" {abt r. a'l. # t t I*l a-/*,1-/e' Owner Location Name aaaress PO /}ox bLt lty Address city ,IH"JL CL state (il*l-zto €Wri f1..trCity Number of tanks at the facility: Contact Tank 2 Tank 3 Tank 4Tank 1 Contact Tank lnstallation Date lq**i9*g Capacity of Tank (in gallons)'2-/<uk rt r-/ft t*at t?J lndicate if tank is siphoned or compartmented. Show related tanks.Pl4 ilq^r -r t;LrI;,vt-Y Substance Stored un!*ta<o -{nrF -l Tank is in use G) No r{bs> No Yes No -n; No lf not in use, give date last used and depth of product in tank.DEI { .tfiilllt{mll0llr : l Current year tank tags are in place zGit No ,6 No Yes No/Yes No Material of construction of tanks - r-41,F/aA / Material of construction of piping ilpn od-t E/pnqt.l / Piping type l0nn-Esuro bi,',n,*/ Type of Spill Prevention device. Note on form if tank is filled by transfers of less than 25 gallons. lf so, no spill prevention is required.Tq*L f r,*// Spill containment bucket is clean, dry, and free of product, water, debris.@'ruo .@ No Y# No Yes No Type of Ovedill Prevention device. Note on form if tank is filled by transfers of less than 25 gallons. lf so, no overfill prevention is required.ftYr,45o I lf an overfill alarm is the primary overfill device: Alarm is located wheJe it can be seen and heard, and alarm is clearly marked. N / n Yes No Yes No /"".No Yes No I Corrosion Protection method used on tanks NA n/A I Corrosion Protection method used on pipinq Mrl NN I Corrosion Protection method used on flex connectors, swinq ioints, etc.T-c-At tanks:itdi"o"n""r"' Ya Enclosed containment sumps at tanks and dispensers At tanks:@ No !oro,"o"n."r., / aftr) No Containment sumps are sealed, free from water, product, etc.No&,;i, lndicate dates ol upgrades- lininq, tank or pipinq cathodic protection N/k or each tank, line,ru-cathodic protection tests are every three years thereafter)months The f.ank ' r"d", /-l Date volts -- voE volts volts DatePiping Tester volts volts \ vorrs volts volts volts >dr,\voltsFlex Connectors/ Swing Joints Tester Date At tank At dispenser volts volts volts volls For lmpressed Current Systems: The results of the last three equipment operation checks are available (required every 60 days).Yes No L generator tanks only; leak detection deferred. tr USTs temporarily closed and empty; leak detection not required tr USTs temporarily closed, locked and secured. COMMENTS I this '8nname: Uyr Site Drawing (North tr ) Qe*. M,^!) Ll( LK Distribution: White- DERFI, Yellow- lnspector, Pink- Facility/Owner Ldchecko7o3.doc Utah Helease Detection Checklist Facilitv lD t = 'u ",, j( I Pase 1 of?*" Ownership of Tanks Usei lLA \Lt b/".* 24\.State UT zio *UUr{ 9J+n e Ca^Y\X^ (D?',.?"" LtE- 1?t? Complete for each tank. lf the facilit{ has more than fbur tanks. comote or adr ona )rm, / Cathodic Protection Testinq. Sholulhe-rcsults of the most recent test w TANK LEAK M for tanks:Automatic Tank G Shutdown PIPING LEAK DETECTION Method(s) Used (Automatic line leak detector and one other method are required lor Pressurized Piping): [[ ] Automatic Line Leak Detector [)s ] Line Tightness Testing [ ] lnterstitial Monitoring t [ ] Statistical lnventory Reconciliation [ ] Vapor Monitoring [ ] Groundwater Monitoring I lnterstitial Mo I .2 GPH Monthly Testing I Other Type of lM documentation used:of maintenance Yes IM @ tlo Manufacturer name and model of properly installed, calibrated, Documentation of pedormance claims the is available. Records on site document that the system and maintained k party certif ication) for No Y@r NozAtbt rrtlr Device documentation is available on site (owner's manual, etc.) No@zffiG) rr,,t ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational. @*oIM16Documentation of valid testing or monitoring is available {or the last 12 months. Show results in table below. l{ not in center, show tilt factors from the setup report.^Tilt: #1 f2 #3.( n^Lr ,r-o rou^fl ) #4GP@@The probe is located at the center of the tank. @ No'Minimum Level:-rrr#L'(J >*/t6bThe tank was filled to at least lhe minimum level required to ensure a valid leak test, and the tank size is within the allowed upper and lower size limits Yes NoIMSystem is capable of detecting a release of regulated substances from any portion of the orimary tanldpipino within one month of release Yes No nlaIMlf observation wells are part of the system, wells are clearly marked and secured to avoid unauthorized access and tampering. nlaYes No IM (Bladder or excavation line0 Secondary barrier is properly placed and constructed, designed lor groundwater considerations, has an acceptable permeation rate, is compatible with the substance stored, is non-corrodible, is always above groundwater, and is not in the 25-yr tlood plain (per site assessment). Yo3tu"{nv Ho,W"u rVa?F%or YorM"/trY Wov "?/ov Wov tu?/oyMo/Yr /3>qt/,/-;"a P's"ro f -;o/olt2*fr tt sgg P >?,,t rs*Fi*t#i './t*tn P >{ro P .*l /' u{6 /r'>$a /*a td =f/P-9o f-t'/,P >*lo P >*o ry4 P .rg2 f >Sqa#L f .'g, { Results of valve nder Resultslinetest are available: Y to show that piping operates at less than atmospheric pressure, has only one check m and has NoYes Piping: Documentation is available and of fop,c4 Test Date Tester UT Mrt.(dDE S Ghov M7 MES&/E S trxbvAutomatic Line Leak each leak detector lndicate type, manufacturer, and model for E- Electronic S- Sump Sensor Po.t t DqrtResults of last leak detector performance test are avqilable.fr). N Results Tester name and cen. lavt Test date: I(ber: Af ,vItIo/Yr #I tt1 #.u # { COMMENTS Distnbutrotr Whjte- DEF!R, Yellow-lnspector, Pink- . Automatic Tank Utah lhrf?rogram Interstitial tr'l indicatePass,Fail,lnvatid,orNoFlesultsloreachmonth.ForATGtests,showthe hiohesl trroduct level tBsled lor each month. Tank4 /Tank 1 Tank 2 Tank 3Line Tiohtn€ss Testinq, Line Leak Detector Testing: PornDasJt hod: Show results of monitoring for piping for the last 12 months. Indicate Pass' Fail,or No Results for each month, Release Detection ln UST Program Checklist Facilitv lD i.f*i {l lOl Page 1 oW Zlstate use, Ownership of Tanks Location Name L, tr" I Ar t,.?.ac\ownerName t L\z,[n (\.rtr F\.,.E Address IilAddress).(6c x ?r{ lrJ citv {- V (i state LAf zip kq ll [Jrl State Contact UT Phone complete for each\anl. ti-the facifity 6ai inorelttran four tanks, complet d rk-$."'f6-nk 2 ,Tank 3 Tank 4Number of tanks at the facility: Tank lnstallation Date l{i* ,'raJ-.'\JrfD )Capacitv of Tank (in qallons) f,)t t+lndicate if tank is siphoned or compartmented. Show related tanks.ttt 2/rr<-ISubstance Stored l1 tLr Yes No Yes NoTank is in use..les.: No veq.' - No "1 t*ii..'t lLlf not in use, give date last used and depth of product in tank. Answer the \.Yes,.! No Yes No Yes NoJes -r NpCurrent year tank tags are in place.FRPMaterial of conslruction of tanks {-'fpx0u]Material of conslruction of piping 'L4,zMtt, Pipinq type T,-{r-FType of Spill Prevention device. Note on form if tank is filled by transfers of less than 25 qallons. lf so, no spill prevention is required.'G)-rio Yes No Yes NoSpill containment bucket is clean, dry, and tree of product, water, debris.No 4/)<bType of Overfill Prevention device. Note on form if tank is filled by transfers of less than 25 qallons. lf so, no overlill prevention is required. /tJJ lk Yes No Yes No lf an overfill alarm is the primary overfill device: Alarm is located where it can be seen and heard, and alarm is clearly marked. the for tanks. Corrosion on ll,il;;;;;/F.,,#{,,#h"o on pioinq h -a'l*3nJls:T u At dispensers:r(Corrosion Protection method used on flex connectors, .*intiiGlfr- At tanks:At NoEnclosed containment sumps at tanks and dispensers Containment sumps are sealed, free from water, product, etc. lndicate dates of upqrades- lining, tank or piping cathodic protection Cathodic recent test for or Yes NoThe results of the last two cathodic protection tests are available (within six montht ol in{td4tion and eyery three years thereafter). volts volts volts voltsTVf'1Tank' Tester .ru voltsr-r-. volts volts voltsDatePipinq Tester - . -Jolts volts voltsvolts volts volts .-.-flF - volts Flex Connectors/ Swing Joints Tester Date Al tank Al dispensor Yes NoFor lmpressed Current Systems: The results of the last three equipment operation checks are available (required every 60 days). tr Emergency generator tanks only; leak detection tr USTs temporarily closed and empty; leak detection not required tr USTs closed, locked and secured COMMENTS I nature: nature: Site Drawing (North ,l ) Jtutu Oistribution: White- DERR, Yellow- lnspector, Pink-Ldcheck0703.doc Location of ,rm- I t1,1Protectionlne4od, rsed A UtarrUST Program TANK for tanks:atic Tank utdown Continuous testi lnterstitial Monitori ent usedof certification) for No (third Dartv'6")- 'Documentation of perlormance claims the system is available.mManufacturername and to the No@n6,*Records on site document that the system is properly installed, ca and maintained (system and tank setup reports, maintenance records) librated, @*o&-w Device documentation is available on site (owner's maQual, etc.) @*oATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational.,IM6 NoDocumentation of valid testing or monitoring is available for the last 12 months. Show results in table below.6-rrtr ll not in center, show tilt factors from the setup report. Tilt: #l #2 #3 #46v"" 7pThe probe is located at the center of the tank. Minimum Level:I A7n@. toft-l The tank was lilled to at least the minimum level required to ensure a valid leak test, and the tank size is within the allowed upper and lower size limits. Yes NoSystem is capable of detecting a release of regulated substances from any oortion of the primary tank/pipinq within one month of release IM Yes No nlall observation wells are part ol the system, wells are clearly marked and secured to avoid unauthorized access and tampering. IM Yes No nla IM (Bladder or excavation liner) Secondary barrier is properly placed and constructed, designed for groundwater considerations, has an acceptable permeation rate, is compatible with the substance stored, is non-corrodible, is always above groundwater, and is not in the 25-yr llood plain (per site assessment) @iant<tortne hiqhest produft level tesled tor eacftlmonth' last 12 rnonths" inOicate Pass, Fail, lnvalid, or No Results ,or each month. For ATG tests, show the t Mo/Yr */ot e /07 Tot alnz Glua tht Vat ela>Plat Itlo<tL/rrz l/a,4 # luil P/ir?,P/qz/,I lr{7,2/l1t iltv?,,Pl.n?^/ ltih P/ti,r Pfuf,,P/qs?o P/r,do Pht% # L)i ,?hzf,,ihtfo Fln%/i'24^flq?^0/zqin /lqv%oIt<4,P{ra?,,?/t qlt ?l<r7,t/tr$ # # PIPING LEAK DETECTION Method(s) Used (Automatic line leak detectgr t Knrior"tic Line Leak Detector b( [ ] Statistical lnventory Reconciliation [ ] and one other method are required for Pressurized Piping): Line Tightness Testing [ ] lnterstitial Monitoring [ ] .2 GPH Monthly Testing VaporMonitoring [ ]GroundwaterMonitoring [ ]Other SafeSuction Piping: Documentation available and verifiable to show that piping operates at less atmospheric pressure, has only one check and has of Yes No Leak Results ol last line tiqhtness test are available: A/ n -,- I Results p P Test Tester name and cert. num UT Method Automatic Line Leak each leak detector lndicate type, manutacturer,model for ES S M E E- Electronic S- Sump Sensor Results of last leak detector performance test are available:fY)- N Results t Test date: 1 a?4)< Tester name and cert. number:ul| lLl Test Method: last 12for lnvalid, Mo/Yr I 1 ,A-*ll I ltt # # COMMENTS Distribution: White- DEFH, Yellow-lnspector, Pink- Facility/Owner ldatgim0703.doc Automatic Tank lnterstitial Tank I Tank 2 Tank 3 Tank 4 I Ownership of Tanks 'tLocation of Tanks Owner Name f ){- l^ \'m. b/-,f(,o,t-u)r- uL/- \bt.;JrL- 4/-{=Address Address City state iJr zip*v//Ll State UT 4 tanks,tanks on Phone Complete for each tank.lf facility has more PhoneContact Location Contact for Number of tanks at facility:Tank 1 Tank 2 yDd *-frq *-frITank lnstallation Date Capacity of tank (in gallons) ' X.-;P * tnl(orn )Substance stored Tank is in use (Y) or, if not in use, give date last used 7 v in theAnswer the following lor all tanks. Note lf not in use, depth of product in tank (in inches) Current year tank tags are in place Material of construction of tanks tfP RP 77PMaterial of construction of piping /1 Piping type Df+>tU/-,t\e 95 Type of Spill Prevention Device. Note if tank is filled by transfers of less than 25 oallons. lf so. no soill prevention is required. ',;il6d;I ,I {"+*\Type of Overfill Prevention Device. Note if tank is filled by transfers of less than 25 qallons. lf so, no overfill prevention is required. rm ln an ove Yes No tanks,Corrosion Protection. it can be seen and and alarm is the Method used on tanks NNNhMethod used on piping Method used on flex connectors iln 6AD NoEnclosed containment sumps at tanks (subpump) and dispensers lndicate dates of upgrades- lining, tank or piping cathodic protection. Cathodic Protection Testing. Show test results for each tank, line, or flex connector. /V i /1 Yes NoThe results of the last two cathodic protection tests are available (within 6 months of installation and every 3 years thereafter). \ volts volts volts voltsDateTank Tester \U\volts volts volts voltsPiping Tester Date volts voltsvoltsvolts volts volts volts volts Flex Connectors Tester Sub pump OispenserDate I Yes NoFor impressed current system: The checks are available. Pase I ot / L of Owner or Owner's duri Ldcheck.wpd rev0302 * Utah UST Program '-' Release Detection lnspection Checklist ID Sa c-- ? Methqd used for tanks: *YA,Method(s) used for pipins: /+>-X name and model number of ATG II\iI NoC@ Yes No Records on site document that the system is properly installed, calibrated, and maintained and tank maintenance ATG IIV Device documentation is available on-site (owner's manual, etc.).6e]' No ALL Equipment used to acquire data, take readings, perform test is adequate, accessible and functional. lnclude ATG console, dipstick, etc.Y6!) ruo ALL Documentation of valid testing or monitoring is available for the last 12 months. Show testino or monitorino results in orid below.C99 ruo ATG The probe is located at the center of the tank, or, if not in the center, show the tilt factor for each tank from the tank setup reoort.@t Tilt Factors: #1 #2 #3 #4 ATG The tank was filled to at least the minimum level required by the manufacturer's equipment protocol to ensure a valid leak test, and the tank size is within the allowed upper and lower size limits.@No IM Secondary barrier is properly placed and constructed, designed for groundwater considerations, has an acceptable permeation rate, is compatible with the substance stored, is non-corrodible, and is not in the 25-yr flood plain (per site assessment). Yes No 0(q tc stR MTG lnventory readings for product inputs and withdrawals are properly obtained and recorded. Readinqs are properlv reconciled.Yes No IC SIR Records include the proper number of water readings, and water readings are used to adiust inventory balances as necessary.Yes No IC SIR MTG An appropriate tank calibration chart is used and is available for review,Yes No IC SIR Dispensers have current calibration stickers or proper calibration documentation.Yes No IC SIR Drop tubes are present and extend to within one foot of the tank bottom Yes No Show results of monitoring for each tank for the last 12 months. lndicate Pass, Fail, No Results, lnvalid (ATG) or lnconclusive (SlR). oMo/Y'r lvt/r-'07 -ltiwt'o t 'ftw1 tUt ',;Jl,laV a L -lutc/'aL UUn 5e4 r oZ #(P /)t p f p f f P f P r # t?-.i)P P P F P ,P P P F r,r ,0 t Date of last Test results # Ltanks lot, I anl( 1 Pl===:i--i- .:,,.,..i,:,,T,anh:,tt,:r,,,,,,,,,;7 Name and Test Method: I of UT Name and Test Method:UT Automatic Line Leak Detectors. lndicate type and model number lor each leak detector.,, MES MES M E S M €S Date of leak detector tJ test:Test results o Pn-l fu4a Safe Suction piping: Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one checkvalve (under pump), and has proper slope of piping. V/A Yes No Comments I /Paoe ol J/ UL c/\ t\,c dLp i)I nspector, Pink-Facility/Owner rev0302 Utah LlST Program Tank and Piping Leak Detection Uu{ 'C)Yvnl'Al 'J>n'ut .147'ql Tank and Line Tightness Testing, Line Leak Detector Testing:Tank 2 Tank 3 //P ,' _-/ I9$UlOrrv..-. tltoh PST Fund. Cleonup.- -. Environmenlol Response ond Remeotqr,-. -. UTAH DEPARTMENT OF ENVIRONMEN Tn,- Tank# Capacity Substance Compliance FinancialAssuranceMech. 2002 UST CERTIFICATE OF COMPLIANCE UTAH STATE FLEET OPS/FUEL DISPENSING P.O. BOX 141152 SALT LAKE CITY UT 84114 WEBER STATE UNIVERSIry 3750 HARRISON BLVD OGDEN UT 84408 Focility lD: 1200301 ISSI]ED TO:LOCATION OF TANKS: APPLh'D EI\TVIRONMENTAL SdRYICES, L.C. PO BOX t82 ROy, UTAH 84067 (80{} 646-7546 T.E.I. SYSTEII,I4fi'O ' T.E.I. LT3 / T.E.I. ULLAGE PRECISION TANK & LINE TEST RESULTS SUMMARY INVONCE ADDRESS: STATE FUEL NETWORK PO BOX 141152 SALT LAKE CtrY, UTAH &4141-1 152 TANK LOCATIOII: WEBER STATE #12OOOO1 3750 HARRISON OGDEN, UTAH WORK ORDER # 0ffi1 TECHHIGIAN: SM TECH *gi,oin VAN *85m STATETECH# UT0121 GROT NDWATER DEPTH: 10'+DATE: 4+N2 TlilE START: (B:@ IIME EiltX 13:30 TlltE sYSTEill HLLED ffi TOPPED: HAs BEEN FILLED TANK TANK PRODUCT TA}IK FILLVENT PRODUCT LINELEAI( WATERIN PUMP TANK }IATERIAL ?YPEI TNF TANK 0.0' I 2 3 4 5 6 I 2 3 4 5 6 tl000 20m R'IJL DSL PASS PASS PASS PASS PASS PASS PASS PASS 0.o'PRESS PRESS cFn PART 2E0, S1JVF swF PRODUCT L|NES TESTED AT g0 LI}IE RATES (GP}I} PSIFOR 15 MINUTES R/UL -.000 DSL..MO ADDITIONAL INFORMATION: TIS SYBTETAND ETTEDrcET8 ffi EXCEEDS lsPA NE{7, ATO AL CERTIFIED TECHNICNN SG}.IATURE :DATE: 44-2002 t^J(f+F Oate: @4/@4/@? Time: @9:53;39 (a2@61 TANK INFORIIIATION; Product : R/UL Capacity t 4W PROOUCT INFORI(ATION: Diameter (in. ) Product Level (in. )Speclfic Gravity Coef. of Expansion t^later on Tank (in. )Starting Temp. (f) Resolution (GaIlons) Head Pressure (PSI) Delta Temp. (r/Hr. ) :9@ : 56" above tank bottom. z @.732 t @.@0,6965 i A" above tank bottom. : 55.158 z @.@t7568 : 1.5 at tank bottom z -Q.@t7 t = 65.4 GaIs.= 2616 CO}IPUTER ANALYSIS RESULTS: Level Rate ( Temp. Rate ( ) ) Final Rate (GPH) . lr I.11 I GPH GPH 4.@t 4.@3 @.@? T E t1 F' L fiL [[ fi; ["", fi U r-fi i.tftBU TU Ti tfiE-rtti nul Es t.lltl.d.u I Lt rrilu (&2{rJ.6L TANK INFORI'IATION: Product : DSL Capacity t 2W PROOUCT INFORTIIATION : Oiameter (in. ) Product Leve1 (in. )Specific Sravity Coef. of Expansion l^later on Tank (in. )Starting Temp. (F) Resolution (Gallons) Head Pressure (PSI) Delta Temp. (r/Hr. ) l,-rCI'** Date: @4/@4/CI? Time:09:53:39 z9A ; 48" above tank bottom. t * 54.2t @.834 Gals.= 108$r @.W4777 . @" above tank bottom. : 55.666 z @.W9A?8 : 1.5 at tank bottom t @.@,44 COI'IPUTER ANALYSIS RESULTS: Level Rate (GPH) = Temp. Rate (GPH) = Final Rate (GPH) = @.@2? @.@2 o.@2@ T E l{ nr tl il li;;: liIflf,t, [r: n il"., tl dff sil Ti me-mi nut es 3ff t?tl 1f;fi A APPLIED \J ENV]RONMENTAL SERVICES, L.C. P.O. Box 182 Roy, utah 84067{1182 (80{} 546-7456 E S T.E.I, ULLAGE TEST DATA SHEET Site: WEBER STATE Date:4-+2ffi2 3750 HARRISON OGDEN, UTAH t{! I o#: I certify that the above ullage tests were conduc'ted on this date according to the equipment manufacture/s proced ures and limitations and the results as listed are to my knowledge true and correct. Signature:State Lic. #:uT 0121 The test data collection time period must be one (l) minute. The test passffail threshold is 0.02 GPH as identified by a noise signal ratio of I to 2 Et a vacuum of t psi. R/UL 1374 2.O ffiTest start ffia*l#rxaru !:rxr:r!%iffi#Timefiffi*Hiffiifl.i*fifuxw.r*i*fl$*fttfiry 12:49 End 12:S $#Test Resuft *4 ffiassraiL+.ffilw*a-rxr s **rvvr rs: Y*fv--.M PASS DSL 915 2.O 13:&5 13:(E PASS 02061 'Aa1#-:a:{fl t V ,1r'-44-*-x\ 4'Slff; i*$.lr+"v;!ff Yii.tl#w A Apptied \/ Environmental S Services, L.C. P.O. Box 182 Roy, tJtah 84067 Gor) 546-7546 E Facllltv: WEBER STATE AES FACILITY INSPECTION'AUDIT FORM Test Date:4+2c02 Work #:02061 3Z5O HARRISON OGDEN. UTAH Stahrs iFlbtPrrea* S=S*Aaorytl{.l*sf*ory Flll @Ys:_rL Fltl Cap:__g_ Fill Gap Seah g Drop Tube: -rLVIRGovcn--E- Vn Soa[_,,L VIfi Dry Br€]il _S_ Sub Pump: j_ $rb Pump@ver:-.L Overfrll: JL IlE€ C=Coodrl tPrcrsrs F=FlcrFIIII AftAngbOhed( lltdtlctelc tHbSt ge| \F\raltcdChedt &Src0on Flll Tlryc: D Prcduct Llne Tlpe: -E[0f&,Tank Sruing Jolnt Typq Dlrp Sing Jolnt llpe: Disp. tloees RIUL: 1 1 Diesel: 'l 1 at..-.L -- -aNum9er or illtlL: SIIJL: lm6Valve:-S- Vertlcal ChecfiValvq Hn Spru Conkinment 1018G Dispenser Contalnment --g-Sub Pump Contalnmert s N*ht Preserf Status S-Salisfiactory tf{.hsaUstadory SFtem Tlpe:g Staoe ll F Brhncc A=Ardd Comrrer*s: Comoliance Detail: (List items that nced attantion^l NONE CERTIFICATE OF PRECISION LEAK TEST APPLIED ENVIRONMENTAL SERVICES, L.C. HAS TESTED AND CERTIFIES THE FOLLOUIIING: WEBER STATE, 37W HARR'SON,UTAH TANK CAPACITY 4(m PRODUCT TANK TY?E FILIJVENT LINES PASS PRODT.ICT LINES PASS UNE LEAK DETECTOR PASLt. 2. 3. 4. 5. 8. t PASS 2000 DSL PASS PASS PASS PASS 02061 4-4-2@2 Sta/on B. Maftin uT 0121 Gertiflcstlon Number Date APPLIED ENVIRONMENTAL SERVICES L.C. P.O. BOX 182 ROY, UT 84087{t.t82 (80{) 546-75'06 Recommcnded Recertlfl cation Date: iirJ STATE FUEL NETWORK\-, PO BOX 141152 SALT I."AKE CITY, UT U141-1152 (8O1) 61*7232 GAS STATION INSPECTION REPORT Facilfi Name and Site Address: WEBER STATE UNIVERS.rIY 3750 HARRISON Facility lD#1ffiOl OGDEN, I.ITAH Purpce: Regdar_ Reinspec,tion_ Complaints_ Annuallnspec.tion X Date:44-20or2 Eoa5E' E'o E'6. u E0, oE tU CI !,o EF. o.cI E =z ACTION TAKEN 1-2 S:torage tanks poperly labeled Fillcaps and underground storage conreregmd Fuel fiFters on pumps Ochne posted on pumps Securityseals intact MOTOR FUEL FRODUCTS USED FOR ]NSPECTION Regular_ gallons Unleaded Regular_.,1[_ gallons Unleaded Plus gallons Unleaded Premium_ gallons Diesel_ 5 gallons Product uras returned to fuel storage tanks. x Pumpe tceted ior calibration x x Watsr techffttel storaga x x x x x lnspecffon Remarls: REMOVER BROKEN BREAKAWAYON DIESEL HOSE Stenren B. Martin LrTfi21 Applied Envionmental Sefficw L.C. Received by:lnspected by x ELIJG ui Pt7 RE[,ijF]T -- .\'/ **r$*rr- I,JETJLLi L;T.'Al.lt,Lti E F UEL I Ntl //-t/-oz_i \ -- --- =EI .-, .,1,.,1 E'IT, EUI,IF, FI.]F]L AI H,APH 4, TAJEBER ,57 f:nf'lPUIi S FUELI I''IG APR 4 E"iIJTEI.I T 1:t,ELl L 1:FUEL L I:ft-lEI- I I',li/El'lTuR i lr'! r' Er"l -- -- EUI1F, r_r:_1 FJ"l ELTiI-; 04 lrl"l REt"r.)Ij:1' [jEtl T I:tE[.1 ttELr I l,lVEt',lTUF: APE 4 Sr"r-:TEll **.*., I Girls B iJTILFJ r; i:i'il.i:i :l tiri[-;'';t I t.ll l-][E3 I l',li-:HES 5 riHLE U I NTTHES B IiF]G F .l r:;Hl.iq t-t Urtl.S I il*Llj ? UALE :1 I I'ICHE.J:] I IT-:HEs rl GHLE'j I N{-:HEi:i5 L,t(:.r F I r_.lAlij E IJHLS E, (-;ALE ! L;HLS :,r I t.lL:HEl:;3 I r,l(-:liEi-j 5 GALS E I l'i(:rHEl:i E LrEt:: F T l:titES V{]LUI,IE ULLgGE 90ri g1-16. Ti: Yg11p1 HEIGIIT ,5T}; HE I G TJATER VO t^JATER TEI"IF q GHLFj O IALSI (jril_s 7 {_;,*L53 I r.lr,;HEl:i;J I I{f.:HF]SII 'JALE7 I l',lr:HEE5 IIEG F T 2: Ul,ll-E VOLUI,IE ULLfiGE 9ttrl 911.; Tt-: ti6t1.1111 HE l GIIT ETH t1E I '.-;I,''i\TER VO I.JATER TENP T 1:trlEr, \/ULUI.1E ULLfiI]E 90!" ULL| T(l \,roLUlI tiE I rjHT llTI,; HE I rj liJA'IEE VO t^JATER TEIlP ?iii cut ,- -- --L -- ,-'l ' ,t r-lL, L.'i :uter ETF FjUI"IT, ifltZ t FtH .--- l"l}j :.iUl'lI' 1 i : ut.tlE VOLUI.,IE ULT,fitrE :'O:i ULLH Ti-r \/all.ut'l HE I rjHT BT}I: HEII:; HATEF VU I.,JATEE TEr"lt, ,.FLIET.i APR ,il ..hLrl 4,:i^,.*t tii. l.rr_j l-'l' t \L AUALI; DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box 144840 Salt Lake City, Utah 841144840 (801) 536-4100 Voice (801) 359-8853 Fax (801) s364414 T.D.D. Michael O. Leavitt Govemor Dianne R. Nielson, Ph.D. Executive Director Kent P. Gray Dircctor DATE:7/17/2002 FROM: William Moore RE: NON-COMPLIANCE OF UNDERGROUND STORAGE TAI\KS AT , AMPUS SERVTCES, 3250 HARRISON BLVD,Hr-,+fth*ffi To continue to maintain a valid Certificate of Compliance, the facility must be in compliance with Federal and State Rules and Regulations. An review of your ATG Data printed February 4,2002,AND a review of last inspection, has shown that the following information is still lacking The inspection documented you are using a Veeder Root TLS-350 Automatic Tank Gauging (ATG) Systern using Standard Test Mode to monitorthe Tank portions ofthe USTs, with Sensors for the Piping Sumps. However, the following Problems have been documented in you use of this system $o -((Wtro The Tank Setup reports indicate the "Tilt" has not been entered for these FRP USTs. Since these are FRP USTs the probes cannot be in the center, since there is a rib in the center of all FRP USTs. Thus the "Tank Tilt" must be calculated. Ifthe calculations results inazero, document the calculations and submit to DERR, if not, enter into the setup and reprint a copy of the setup report and submit to The above information must be submitted to this is not received by the date specified,Continued non- compliance will result in the fees on your Certified USTs to be from $75 per tank to $ I 50 per tank and failure to pay the additional fee can result in lapsing ofyour UST Certificate of Compliance. Ifyou have que sti o n s *"")Tr r"," r** u)',*o :,-,"; /t:;#f' k*," * :),* ; ;,*.0 t) s3 6 - 4 1 0 0 tleftsl,e 4*e Lrtl an 737 6*/2/,,4 ll by 911712002.If fi- s'- ct TO: Steve Canning Utah State Fleet Services 447 W.13800 S., POB 14t152 Salt Lake ciry, Utah 84141-1152 Michael 0. Leavitt Govemor Dianne R. Nielson, Ph.D. Executive Director Kent P. Gray Director TO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box 144840 Salt [ake City, Utah 84114-4840 (801) 536-4100 voice (801) 359-8853 Fax (801) s36-4414 T.D D. Steve Canning Utah State Fleet Services 441 W. 13800 S., POB t4tt52 Salt Lake city, utah 84141-1152 DATE:7117/2002 FROM: William Moore RE: NON.COMPLIANCE OF UNDERGROUND STORAGE TANKS AT WEBER STATE UNMRSITY MOTOR POOL, CAMPUS SERVICES,3ZID HARRISON BLVD, OGDEN, UTAH; FACILITY ID# 1200301. To continue to maintain a valid Certificate of Compliance, the facility must be in compliance with Federal and State Rules and Regulations. An review of your ATG Data printed February 4,2002, AND a review of your last inspection, has shown that the following information is still lacking: tll The inspection documented you are using a Veeder Root TLS-350 Automatic Tank Gauging (ATG) System using Standard Test Mode to monitor the Tank portions of the USTs, with Sensors for the Piping Sumps. However, the following Problems have been documented in you use of this system: a.The Tank Setup reports indicate the "Tilt" has not been entered for these FRP USTs. Since these are FRP USTs the probes cannot be in the center, since there is a rib in the center of all FRP USTs. Thus the "Tank Tilt" must be calculated. If the calculations results in a zero, document the calculations and submit to DERR, if not, enter into the setup and reprint a copy of the setup report and submit to DERR. The above information must be submitted to this office by 911712002.If it is not received by the date specified, we will commence the revocation process of your Certificate of Compliance. Continued non- compliance will result in the fees on your Certified USTs to be increased from $75 per tank to $150 per tank and failure to pay the additional fee can result in lapsing of your UST Certificate of Compliance. If you have questions concerning this matter or need any assistance, please contact William Moore at (801)536-4100. Michael O. lravitt Govemor Dianne R. Nielson. Ph.D. Executive Director Kent P. Gray DilEtor TO: DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box 144840 Salt Lake City. Urah 84114-4840 (801) 5i6-4100 Voice (801) 359-8853 Fax (801) 536-4414 T.D.D. Steve Canning Utah State Fleet Services 447 W. 13800 S., POB r4tt52 Salt Lake City, Utah 84141-1152 DATE: 611212002 FROM: William Moore RE: NON.COMPLIANCE OF UNDERGROUND STORAGE TANKS AT WEBER STATE UI'IMRSITY ivIOTOR POGI, CAS{PUS SER\/ICES, 3250 FL^.P.P.ISON B[,I/D, OCDEN, UTAII; FACILITY ID# 1200301. To continue to maintain a valid Certificate of Compliance, the facility must be in compliance with Federal and State Rules and Regulations. An review of your ATG Data printed February 4,2002, AND a review of your last inspection, has shown that the following information is lacking: t1l The inspection documented you are using a Veeder Root TLS-350 Automatic Tank Gauging (ATG) System using Standard Test Mode to monitor the Tank portions of the USTs, with Sensors for the Piping Sumps. However, the following Problerns have been documented in you use of this system: The "Leak Min Per" is set to 25Va, and can be a Minimum of 30Vo for this Standard Leak Test software. All Leak Tests are suspect for being valid with this set wrong. Correct and submit a copy of a new The "Periodic TestFail" and the "Gross Test Fail" Alarms are Disabled. Enable these alarms and instruct on site personnel to inform you immediately upon a fail of one of these alarms. Correct and submit a copy of a new Setup Report. The Leak Test Report Format is set to "Normal" and should be set to "Enhanced" for a stand alone report. Correct and submit a copy of a new Setup Report. de- a. b d. /e ,/r. The above information must be submitted to this office by 8ll2l2WL If it is not received by the date specified, we will commence the revocation process of )rour Certificate of Compliance. Continued non- compliance will result in the fees on your Certified USTs to be increased from $75 per tank to $150 per tank and failure to pay the additional fee can result in lapsing of your UST Certificate of Compliance. If you have questions concerning this matter or need any assistance, please contact William Moore at (801)536-4100.q!- ITffiCEIVED A$-,P JUL r 7 2002 DEO Environmental Response & Remediation The Tank Setup reports indicate the "Tilt" has not been entered for these FRP a copy of the system sstup to document tilt, or submit the calculation to show out to zero, ifthey calculate as such. s. they Michael O. Iravitt Govemor Dianne R. Nielson, Ph.D. Executive Director Kent P. Gray Direclor DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box 144840 Salt Lake City, Utah 84114-4840 (801) 536-4100 Voice (801 ) 359-8853 Fax (801) 536-4414 T.D.D. TO Steve Canning Utah Statd Fleet Services 441W.13800 S., POB l4tr52 Salt Lake City, Utah 84141-1152 DATE: 611212002 FROM: WilliamMoore RE: NON.COMPLIANCE OF UNDERGROUND STORAGE TANKS AT WBBER STATE UNIVERSITY MOTOR POOL, CAMPUS SERVICES,3250 HARRISON BLVD, OGDEN, UTAH; FACILITY ID# 1200301. To continue to maintain a valid Certificate of Compliance, the facility must be in compliance with Federal and State Rules and Regulations. An review of your ATG Data printed February 4,2002, AND a review of your last inspection, has shown that the following information is lacking: tU The inspection documented you are using a Veeder Root TLS-350 Automatic Tank Gauging (ATG) System using Standard Test Mode to monitor the Tank portions of the USTs, with Sensors for the Piping Sumps. However, the following Problems have been documented in you use of this system: a. The "Leak Min Per" is set to 257o, and can be a Minimum of 30Vo for this Standard Leak Test software. All Leak Tests are suspect for being valid with this set wrong. Correct and submit a copy of a new Setup Report. b. The Tank Setup reports indicate the "Tilt" has not been entered for these FRP USTs. Submit a copy of the system setup to document tilt, or submit the calculation to show they calculate out to zero, if they calculate as such. c. The "Periodic Test Fail" and the "Gross Test Fail" Alarms are Disabled. Enable these alarms and instruct on site personnel to inform you immediately upon a fail of one of these alarms. Correct and submit a copy of a new Setup Report. The Leak Test Report Format is set to "Normal" and should be set to "Enhanced" for a stand alone report. Correct and submit a copy of a new Setup Report. The above information must be submitted to this office by 8ll2l2002.If it is not received by the date specified, we will commence the revocation process of vour Certificate of Compliance. Continued non- compliance will result in the fees on your Certified USTs to be increased from $75 per tank to $150 per tank and failure to pay the additional fee can result in lapsing of your UST Certificate of Compliance. If you have questions concerning this matter or need any assistance, please contact William Moore at (801)536-4100. d. \ A Ownership of Tanks Location Name t,t)p\-, rB <L,'.1 - IownerName ( I lr,l,, <l-a'le- { lo"* Girt,no d ttzn. i{ -, R " aqa --{.,{,. e*.o,{a I [t{;'Address Address ?z <rr A, in "2, .. ^' tr'l ,,-(I State UT.,","-i lut. ,to Cqtil Contact Phone Contact Phone more than 4 tanks, complete information for additional tanks onComplete for each tank. lf facility form. Number of tanks at facility:Tank 1 Tank 2 Tank 3 Tank 4 <- kq k -s( <lTank lnstallation Date 7l<A(Capacity of tank (in gallons) .t), p-.o I Qr., ,r^ [.1Substance stored Tank is in use (Y) or, if not in use, give date last used Y lf not in use, depth of product in tank (in inches) iclr tCurrent year tank tags are in place il()Dl Material of construction of tanks (steel, FRP, composite, etc.)E€. P trRptr{pMaterial of construction of piping (steel, FRP, flex plastic, etc.)fRp Piping type (pressure, safe/US suction, gravity, etc.)A Al,r .t t np f)r/e\( r 1A.Q-- Type of Spill Prevention Devi9e (<5 gal, >5 gal, cont. sump, etc.) Note rl filled bv transfers of less than 25 gallons- lf so, no spill required.a>, tt L,ra ke*\ d^,, l.,cPType of Overfill Prevention Device([Shu9llball lloat, alarm, etc.) Note il filled by transfers of less than 25 gallons. lf so, no overfill required. For overfill alarm: Alarm is located where it can be seen and heard, and alarm is clearly marked Yes No Corrosion Protection. Answer the tollowing lor all tanks. Note any exceptione in the last column. Method used on tant<s 6(0, CS, lL, lC, SA, NP) Method used on piping @-CS, lC, SA, NP) Method used on flex connectors (B, CS, NC, CP,{@ NP, N/A) Enclosed containment sumps at tanks (subpump) and dispensers No(a- lndicate dates ol upgradps- lining, tank or piping cathodic protection. Cathodic Protection Testing Complete for each tank. IrYes@The results of the last two cathodic protection tests are available (within 6 months of installation ind every 3years thereaftefl.+ rank resteru {i-/ ,, r-' / J '/r*r/, n o^r"/- /> -)/h) pipinq Tester "a/ -, .,o''///lrllrno^r" t-/Z-?rm l-- Sub volls Sub volts Sub volts Sub volts rester (/r rn tl/rr/-Date /-r > -t7tFlex voltsDisp.vollsDisp.voltsDisp.voltsDisp. For impressed Clirrenl systerfi: The results of the last three equipment oDeration checks are available. (required everv 60 davs.)Yes No Q errrA..-{r\o, c, <}rrrr\<, d,...o L tLrtSn r:.rAc- 2rll\hCommentsFrA \-^^ k, r r.Rnr{ c {'."L.rr A.'\,,I //Page of / /t/ /"' ,/l nd* rnrt^"pected the above-named racirity on (date)l(name)///.fih%,/.%,Date &' i'i(- rttlnsoector's sionature of Owner or Owner's nt duriSi Distribution: White-DERR, Yellow-lnspector, Pink-Facility/Owner rev0201 L ID Location of Tanks V 4{^ Answer the following for all tanks. Note any exceptions in the last column. At a rLq 3so Arc \r-s?cc,Method used for tanks:Method used for piping: name and model number of cert. available Yes No @ruo t_ Ail Records on site document that the system is properly installed, calibrated, and maintained and tank maintenance ATG IM Device documentation is available on-site (owner's manual, etc.)G. No Ail Equipment used to acquire data, take readings, perform test is adequate, accessible and functional. lncl. ATG console, dipstick, etc.No@ Ail Documentation of valid testing.or monitoring^is available for the last 12 months.,Show testinq or monitorinq results in qrid below.No@ ATG The probe is located at the center of the tank. lf not, the tilt correction factor for each tank is shown on the tank setup report.@to ATG The tank was filled to at least the minimum level required by the manufacturer's equipment protocol to ensure a valid leak test and the tank size is within the allowed upper and lower size limits.@*o *l /) IM Secondary banier is properly placed and constructed, designed for gw considerations, has an acceptable permeation rate, is compatible with the substance stored, is non- corrodible, and is not in the 25-yr floodplain (per site assessment). Yes No v50 IC MTG SIR lnventory readings for product inputs and withdrawals are properly obtained and recorded. Readings are properly reconciled.Yes No IC SIR Records include the proper number of water readings, and water readings are used to adjust inventory balances as necessary.Yes No IC MTG SIR An appropriate tank calibration chart is used and is available for review Yes No IC SIR Dispensers have current calibration stickers or proper calibration documentation.Yes No IC SIR Drop tubes are present and extend to within one foot of the tank bottom Yes No Show results of monitoring for each tank for the last 12 months. lndicate pass, fail, no results, or inconclusive, Mol/r I\n,2.tJaF<fh\"fr 4ooo a A,f""a J"tz ao \un \ ( rrh f,{Ru *7.1tr A*q ,nr It{.soq,in FA: / I/b ',)ar. I ol #t f P {,p L) P P 0 +P p P p #'>P p P p P P a p p o p p # Test results: # Tanh I R tanxz P Tank 4 Name and certification number of tester: Li'3\AvE Test QeLe of last tightness test lor piping: I - \Test results:Z- -fcnt P P N cLt(, Name and certification number of tester:{cest^ t \ Test 7-A- performancetest: It\ Z -Z Cl\l l'{ resultsDate of last leak detector p ,P 'Safe Suction piping: Documentation is available and verifiable to show that piping operates at less than atmospheric pressure has only one check valve (under pump), has proper slope of piping. Yes @/ Comments Paoe of White-DERR, Yellow-lnspector,Ldall Utah UST Program Tank and Piping Leak Detection ID Circle Yes or to the answer Tank and Line Tightness Testing, Line Leak Deteclor Testing:Tank 0 Date of last tightness test for tanks: t - f Z. - A f)n I i Fleet Operations Speed Memo tLoqe1 Date: i I lq q. To OEQ f D.- ar\ From : Steven L. Canning , UST Program Specialist/Safety Officer State of Utah / Department of Administrative Services Division of Fleet Operations / Fuel Network 4120 State Office Bldg Salt Lake City, Utah 84114 Dear The following is in response to your questions concerning , .-{fis-u\J4r*..-^ SJ.;,Azl c O€4. \0 '+ lzc>c>Ba Item# 1 E.^^-a- 1f ^r.r"A^r-T r' a ,-i "ru Item# 2 Item#3: Item# 4'. Thanks J VT *.{ **il r* L."* \.*=# DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box lul4840 Salr L,ake City. Utah 84114-4840 (801) 536-4100 Voice (801) 359-8853 Fax (80r) 536-4414 r.D.D. 1 Michael O. [ravitt Govcmor Dianne R. Nielson. Ph.D. Exeutive Direlor Kent P. Gray Dircc!or October 12,1999 TO:Steven Canning State of Utah/Fleet Operations 1380 West North Temple Salt Lake Ciry, UT 841l6 RE Non-compliance of underground storage tanks at lvebcr State University, 3750 Harrison itlvd, Ogden Utah; Facility I.D. #1200301. The Utah Underground Storage Tank (UST) Act provides that the Executive Secretary (UST) may revoke a Certificate of Compliance if it is determined that a facility is not in substantial compliance with all state and federal UST statutes, rules and regulations. At the request of the Executive Secretary (UST), the Division of Environmental Response and Remediation (DERR) performed a compliance review for the underground storage tanks at the above facility. The compliance review, performed on August 17,1999, indicates you have not satisfied the requirements of the Act and are out of compliance. To achieve compliance you must do the following: 1. Submit a copy of a current precision line tightness test for the product lines associated with tanks #1 andtlz. 2. Submit a copy of a current annual test for proper operation of the automatic line leak detectors on the pressurized product lines associated with tanks #1 and. #2. Please return a copy of this speed memo with the above items to speed processing. If the above information is submitted to this office by November 22,1999, and srrtrstantial compliance is achieved and maintainecl, no further action will be taken on this matter. Failure to respond to this request by the date specified will initiate the revocarion process for your Certificate of Compliance. If you have questions concerning this matter or need any assistance, please contact Paul Harding at (801) 536-4108, \ APPLIEL E SLITVTCES, L.C. PO BOX {82 ROy, UTAH 84067 (80{1546-7515 T.E.I. SYSTEIII{IOO 'T.E.I. LT3 'T.E.!. ULI-AGE PRECISION TANK & LINE TEST RESULTS SUMMARY I?$/OIGE AOORESS: REETiJi,AI'IAGEMENT 4t2O TATE OFFtrE H,JN.DNG g{LTt-At(E Cny, UTA{ 84{t4 TiAPACITV TAJTTI{ LQCATION: WEBER STATE #12(l(13OI 3750 FIARRTSON OGOEN. UTAFI WORK ORDER * ss4sg TECHMCIAN: SM TECH T9A$27 VAN r85{p STATETEGH# UTOI2I GROUNDWATERDEPTH:'10'+OATE: lt-&tggg TIME S1ART: l3:0U TIME ENO: 17:00 NME SYSTEM FILLED OR TOPPED: I{AS BEEN FILI-ED TAI.IK TAIIIK PROI}UCT TANK FILL VENT PRODUCT \/APc}R LINE LEAK DETECTOR WATER IN TANK PUtblP TAIrIlt }TIATERIAL TYPE I ? J 4 5 6 4000 2000 R/UL DSL PASS FASS PASS PASS FASS PASS PASS PASS 0.0' 0.0" PRESS PRESS 1 2 3 t 5 6 PRODUCT LINES TESTED AT LINE RATES (GPH} PJUL-.000 DSL -.000 ADDMONAL INFORMATION 5C PSIFOR i5 MINUTES THIS SYSTEI A}ID IETHOO IIEETS OR EXC€EOS IiFPA $29{7. A}tO ALL a{r, cfRPAffT280, c{rBE$. CERTIFIED TECHHICIAIT SIGHATlIRE :DATE: 11-3-1399 APPLIED ENUIRO]IIMENTALs SERVICES, L.C. A E P.O. Box 182 Roy, Utah t40674t82 lE0rl5{6-7f56 T.E.I. ULI.AGE TEST DATA SHEET Sile: UUEBERSTATE flrta..t l_B-l qqq 3750 HARRISON OGDEN, UTAH uiloilfr 99433 I certiff that the aboYe ullsge manufachtrert pmcedures and tests were conducted on thi* date eccording to tfie equiFment and the results as listed are to my knowledge true and correct' Cianoir rroJ.q..a.ru. L State Lic. *I rT n{'}lur u14l The tert data collection time period must be one {l} minute. The tett patrfftil threshold is 0-0? GPH at idenfified hy a noise $gnal ratio of 1to2 at a vacuum of I p*i' EndStart Result 16:35 :t go-rt gal::t PASSaF-4' I O.-1+t-uRiUL1972 +:=*lgilIE.r]== PASS16:5016:499862.0OSL I I I I I I I i I I I I .TE I EtYt ,,-ElY|4{A(AED FlNf:ll_.. 3 r E3 EIHEE-I- t lEl{+ SS+EJB TRHH XNFORilATIOHT. Frsduet I RIULCapaeity r 4OBS trRODUCT INFOR}IRTIONT Dlemrtcr (ln. ) I Fr.oduet Lrvrl ( In. ) IBp:ctfle Bmvlty ICecf. of Exprnsion E l.latrr. on Tenk ( in. ) IStartlng Trmp. (F) IRegnlutien (Gallons) I Hcad FrcasuRe (FISI ) IDrltr Ttmp. (F/Hr. ) r COI{trUTER ANRLYBXS REEULTST Level Rste (EF|H) rE Tcmp. R*tr (6ErH) D Finel Bste (BPHI Drttrr lt/OB/99 Timer lSrSQl46 9t 46" *bovc tank bsttom. u,?sg 0. Bsu68a9 Qrr ebove t*nk bottsm. 66. 6l I 0. QQt793ll.g at tank bettem -Q. &Q&6 Q. Ul7 Q. QUU II*IEIEEIITE! 6.6t7 l( - 5O.7 Bels.* ESEB TI E fl P IIt-I II f, L 0 d0 3E Ti me-mi nut es 30 1?n 15t] t lcl{+ EE4'EB TRNK INFORIIIATIONTFroduet r DSL Capeclty r BQQQ FRODUCT INFORIIRTIONT Dirmcten (ln. ) r Ftxrduet Lrvrl ( ln. ) ISprclfie Bnevlty IEoaf. of Expen:lon rtlrtan trn Tenk (ln. ) r Strrrt ing Tsmp. (F) r Rcgc.lution (Bnllene) r Hcrd Frrtrurr (trSI) rDrltr Tlmp. (F/Ht. ) r COI'IFUTER RNRLYSIS RESULTSI Level Rate (6trH) =Trnrp. Rrt; tEFrH) n FLnaL EEte (gPHt Drtcr lt/OB/99 Tlmer lSr3Or46 a9 {$r' rb$vn trnk bottom. 6.8S4 o. ooQ4Tel Qrr ebovr tenk bettam. 64. Ur44 e. Q0G9IE5l. { rt tenk bottom B. QOld B. BS9[. UI|AU 6, fi22 ,( r sE.7 B&ll. - lQl+ TI E H F L H II I It- 6t| 30 Ti me-mi nut es 30 120 180Lr Applied E Environmentat E Services, L.G. A P.O. Box 182 Roy! Utnh 8.l'067 (80t1 516-75,16 Fecilitv: UIEEER STATE AES FACILITY INSPECTION/AUDIT FORM Worlrl*, 1I-&1999 OGDEN UTAH 99433 Status IrFNot Pre€ent S-S atlEtlcl0ry tFunr lftsctory Fill Cover: S Fili Cap: S Fill Cap Seal: _E_ Drop Tube: -lVrn Cover: _19_ VIR Seai: -;!_ VrR Ory Break: S Sub Pump: _--,1 Sub Pump Cover: _jl* Overfill: 5 TYpe Cicoaxlal P-Pr€EsUre F-Flex IFOual ,FAngle checL tr!-Mel! tc tl-No Stale I V-Venleal Cieck gsucllon Fill Type: D Product Line Type: DW FL Tank Swing Joint Type: _ Disp Swing Joint Type: _ Number of Diep. Hoses RJUL: I I M/UL: S/UL: Diesel: --j- f Strtuq [FNol Presenl - S-ri di6fdclo r_t I FllnrrlrHl.:r^rr lmpact Valve: 5 Vertical Check YBlye: _14_ Fill Spill Containment: S OispenserContainment: S Sub Pump ContEinment: S Staqe !l EF Brlinae Systenr Type: E Comoiiance ii: {List items that need imm ta te attention-i N(-,1\E Test Date: 3750 t-tAftRrsoN Comments: TfE CERTIFICATE OF PRECISION LEAK TE[;T APPLIED ENVIROHMEHTAL SERVICES, L.C. HAS TE$TED AHD CERTIFIES THE F OLLOI'UINGI WEBER Sf,4TE, 3750 H.4RR/SOA], O,:3r[)F,V, UI'4H TANK CAPACITY 4000 PRODUCT TANK TYPE FILLA/EHT LIHES PASS FRODUCT LIHE LE:AI{LIHE$ DETECTOF PASS FA.$$I 2 3 4 5 6 R/UL E5SE. PAES2000DSL PASS PA.$S ItrdL_ 99433 11-B-1 9g!1 Steverr E, Martln UT Rl?1 Ccrtllicatlon Numbcr Datp APPLIED ENVIROHMEHTAL SERVICES L.C. P.O. EOX {82 ROY, UT 84067fi18.2 (801! 546.7546 Retonrmentled Resertiflc ation TfiT +H{ l&i ) t D ) UTAI, uEPARTMENT OF ADMINISTRATIVE SERV'CES DIVISION OF GENERAL SERVICES FLEET SERVICES.FUEL DISPENSING 1380 West North Temple s.L.c., uT 84116 (801)521-2706 GAS STATION INSPECTION REPOBT Address 37SO /l,4r2,et<r'r/City il-Ae.r1-/ County tu2-B?--r4-zip Purpose: Regular l,/ Reinspection - Complaints - z Storage tanks properly labeled Fuel filters on pumps Octane posted on pumps Security seals intact MOTOR FUEL PRODUCTS USED FOR INSPECTION ol) E z tto E' Eort @o Next inspection due / l/R days Action Taken: gallons I Regular gallons Unleaded Regular Unleaded Premium - gallons Product was returned to fuel storage tanks. gallons Unleaded Plus Diesel m gallons r t/t/Pumps tested for product calibration vWater tests/Fuel storage V V t/ t/ t/ TIllIIIIII III lnspection Remarks: Beceived by lnspected by Name /,(/EPR s"->r€ Fst"l.D.# /zooSol Date //-8-?? {) oF o oo'a E Fill caps and underground storage covers-good condition )zAAnt-/ 1 DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box l4-1840 Salr Lake Citv. Utah 8411.1-+810 t80l) 536-4100 Voice t80l) 359-8853 Fax r 80 I ) 536-,14l,l T.D.D. t2ooSO I \ftchaei O. Leavitt (lolcmor I)ianne il. .r..iclson. Ph.D. l:-\ecurve Drrector Kcnt P. Gray Drrector October 12.1999 TO Steven Canning State of Utah/Fleet Operations 1380 West North Tempie Salt Lake City. UT 84116 RE Non-compliance of underground storage tanks at Weber State University. 3750 Harrison Blvd. Ogden Utah; Facilitv I.D. #120030f . The Utah Underground Storage Tank (USD Act provides that the Executive Secretarv (UST) may revoke a Certificate of Compliance if it is determined that a facility is not in substantial compliance with all state and federal UST statutes. rules and regulations. At the request of the Executive Secretary (UST), the Division of Environmental Response and Remediation (DERR) performed a compiiance review for the underground storage tanks at the above facility. The compliance review, performed on August t7,1999. indicates you have not satisfied the requirements of the Act and are out of compliance. To achieve compliance vou musr do the following: 1. Submit a copy of a current precision line tightness test for the product lines associated with tanks #1 and #2. 2. Submit a copy of a current annual test for proper operation of the automatic line leak detectors on the pressurized product lines associated with tanks #1 and #2. Please return a copy of this speed memo with the above items to speed processing. If the above information is submitted to this office by November 22.1999, and substantial compliance is achieved and maintained. no further action will be taken on this matter. Failure to respond to this request by the date specified rvill initiate the revocation process for your Certificate of Compliance. If you have questions concerning this matter or need anv assistance, please contact Paul Harding at (801) 536-4108. I ,A UTAH UST PROGRAM Facility .D No"/8Op 3a I onl 1 l. Ownership of Tank(s)ll. Location of Facility Name lneTvz9taL- At UST 4 Contact for Area CodeBol 7U /.t F4ez ! 7777- 4/ zo SzZ 9e than 4 tanks, complete information additional tanks onll lacility has Owner Name Address State County l&/1/rl Street Number of tanks at facility:Tank 4 form. Certificale ot Comltiance on site@No Tank 3 "'r 5r/+r trtE'" ,,( r Z"git a /. D r*;rc Current year tag is displayed ,@ No @-*o Yes No Yes No 6@ No @No Yes NoTank presently in use Yes No lf not in use, date last used lf not in use, depth of product in tank (in inches) 8- A?Month and year tank installed 3-fa Capacity of tank (in gallons)22 4r 2)os.r,,/4/lSubstance stored Material of construction of tank (steel, FRP, etc.)ftr trRP trP7Material of conslruction of piping (steel, FRP, etc.) checklist tor method used.lV. Release Detection TankS lndicale the method(s) used for each tank. Complete Piping type (pressure, suction, gravity, etc.) Emergency Generator tank (leak detection deferred) I tank checklists where applicable. Method used (enter method used and complete appropriate form) Method used (complete separate form where applicable) V. Release For lndicate method(s) used and Automatic Line Leak Detector type and model t- Q-qz)(L -?7)Date of last Leak Detector performance test -,l Test result (pass/fail)W;b€s Date of last Line Tightness Test t{'L-d {-q 7>zfu1Test result (pass/fail)L Hs Name and company of certified tester frit fi,Cert. No. UT /z/ No leak detection required (must answer'yes'to all questions below) Operates at less than atmospheric pressure Yes No Slope of piping allows ALL product to drain into tank when suction is released Yes No Has only ONE check valve, located directly under pump Yes No Above information is verifiable; use comments section below to document how it is verifiable Yes No 8- t2^qi (Mth, day, )€s, dfr) I a ? that have above-namedthe facil oninspectedity Signature of Owner or Owne/s Representative Present During lnspector's Distribution: White-DERR, Yellow-lnspeclor, Pink-Facility/Owner Revised 2/4/99 City lll. Tank lnformation @)(7iITT) er g. lr k?Ur /rlofi<;,,aa Z.<<-tc rrl-n 'Lm .d-Tt I ,^ UTAH UST PROGRAM Automatic Tank Gauging Faciriry ono. /ZO 0 3d I Manufacturer, name and model number of system t/** rE -z-PtaT res !s-) Please circle Yes or No for each question lor each tank r hcility has more than 4 tanks, complete information for additional tanks on separate lorm. ,dffi,Tank 3 Tank 4 Device documentation is available on-site (e.9., owner's manual).I 6tto .<G)Ho Yes No Yes No Records on site document that the system was properly installed and calibrated (system ( and tank setup report). G)No @ No Yes No Yes No System is maintained in accordance with manufacturer's instructions(records are available on site). @"o @*o Yes No Yes No The probe is located at the center of the tank. lf no, indicate tilt correction factor from the tank setup report. @r,ro Titt: @No Tilr: Yes No Tilr: Yes No Titt: Device can measure the heiqht of the product to the nearest 1/8 of an inch fi9 No rnE? r,ro Yes No Yes No Device monitors the in-tank liquid levels over the lull range ol the tank's internal height -@ No ,46> tto Yes No Yes No A monitoring box is present and there is evidence that the device is working (i,e,, the device is equipped with roll of paper for results documentation) @*o b*o Yes No Yes No Documentation is available demonstrating that the Automatic Tank Gauge performed a valid leak test at least once a month tor the last 12 months @x"t9"Yes No Yes No lf no, for which months was a valid test not performed? (specify months and year, use space below if necessary) The tank was filled to at least the minimum level required by the manufacturer's equipment protocol to ensure a valid leak test (nJFr'ro @"o Yes No Yes No The tank capacity is within the upper and lower size limits required by the manulacturer's equiDment protocol to ensure a valid leak test @Ho d9*o Yes No Yes No Have any ol the leak test reports indicated a failed test? lf yes, specify in the space below the month, year, and what follow-up actions have been taken, veG ves @ Yes No Yes No Documentation of performance claims for the automatic leak test leature is available and t shows the ability to detect leaks of 0.2 gph with 95% or greater probability of detection and 5/" or less Drobabilitv of talse alarm (3rd Dartv certilication). Glr uo @ No Yes No Yes No lndicate month(s) of invalid or missing test: lndicate month(s) ol any Iailed test: Comments lnspector's Signature of Owner or Owner's Representative Present During lnspection Distribution: White-DERR, Yellow-lnspector, Pink-Facility/Owner Revised 12\95 ,'rtr) ,4. UTAH UST PROGRAM and Protection Facility lD Checklist Please complete lor each lank. Use additional forms as necessary if the lacility has 66nkL)-/-aa-ffit Tank 3 Tank 4 The UST system is lilled by transfers of 25 gallons or less. lf yes, spill and overtill prevention is not required.Yes- (@ - Yesd1(D Yes No Yes No (,.'6 ruo @ruo Yes No Yes Nols there a spill containment device that will prevent release of product into the environment? lndicate type: Spill bucket <5 gal., Spill bucket >5 gal., ls there an over Ball lloat (in venr c (specily) Containment sum at tank fill ention tank? lndicate type atic shutolf (in fill larm. or Other @No No@ Yes No Yes No For overlill alarm only: ls the alarm located where it can be easily seen and heard by the delivery driver?Yes No Yes No Yes No Yes No Yes No Yes NoFor overfill alarm only: ls the alarm 6lsady.marked to indicate what is meant when the alarm sounds?Yes No Yes No N C Cank4 _.r L Tank 2 -,,Tank 3 Tank 4 l/mTank VATank Tank Tank PipingN rt'\N"''h lndicate the type of corrosion protection: Non-metallic (NM), Composite steel (CS), lnternal lining (lL), lmpressed Current (lC), Sacrificial Anode (SA). or Not protected (NP).Piping Piping Sub Pump Sub Pump Sub-Pump Sub-Pumplndicate the type of corrosion protection on Flex connectors and/or Swing .ioints: Booted (B), Total containment (TC), Not In contact with soil or water (NC), Cathodically protected (CP), Non-metallic (NM) and Not Protected (NP)#'"€"DisponserTC*.Oispenser 0isponser lf lank or piping has been upgraded, indicate date upgrades were performed: Tank lining Tank cathodic protection Piping cathodic protection Record test.ping/flex set. The results of the last two cathodic prolection tests are available. (within 6 months of installation and every 3 years thereafter).Yes No Yes No Yes No Yes No DateTank. Tester volls volts volts volts Piping. Tester volls volts volts volts Sub'Pump volts Sub-Pump volts Sub Pump volts Sub-Pump volts DateFlex. Tester Dispenser volts Dispenser volts Disp€nser volls Dispenser volts For impressed current system: The results of the last three equipment operation checks are available. (Equip. check required every 60 days.)Yes No Yes No Yes No Yes No Comments lnspector's Siqnature oJ Owner or Owner's Representative Present Durinq lnspection: Dislribution: While-DERFl. Yellow-Pink'Faci Date \ UTAH STATE, FLEET SERVTCES/TANK MGMT. B-38 STATE CAPITOL BLDG , ATTN: DAVTD G FLETCHER SALT LAKE CITY UT 841,T4 March 17, 1998 Re: December 22,1998 upgrade deadline for Underground Storage Tanks Division of Environmental Response and Remediation (DERR) records show you have one or more underground storage tanks (USTs) which have not met the December 22, 1998 UST upgrade requirements. These tanks are located at WEBER SiAfg UNIVERSITY, 3750 HARRISON BLVD Under Federal regulations issued in 1988, UST owners and operators have until December 22, lgg1 to upgrade, replace, or permanently close USTs that do not meet the requirements for protection against spills, overfills, and corrosion. This deadline will not be extended. If your tanks are not in compliance by the deadline, they will not be able to receivedeliveries of fuel. The DERR encourages owners and operators to meet the 1998 upgrade requirements as soon as possible before the December 22, 1998 deadline' It can take several months to upgrade, close or replace an UST system. Delays are not unusual, and contractors may not be available if you wait. Start planning now! Our information shows these requirements have not yet been met: Tank Capacity Spill Protection 2000 No 4000 No a tzod 3O I Tank ID Substance I Gasoline 2 Diesel Overfill Protection Yes Yes Corrosion Protection Yes Yes Any metal flex connectors connected to fiberglass reinforced plastic (FRP) piping at the submersible pump or dispenser must becathodically protected or taken out of contact with the soil. USTs filled by transfers of less than 25 gallons at a time (usually used oil tanks) are not required to meet the spill and overfillprevention requirements as part of the upgrade requirement. If you have questions about which requirements you still need to meet, or would like to have someone visit your site to help assessyour needs, please call Alan Jones ar (801) 536-4115. ]: \l,t .\ DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Michael O. Leavitt Govemor Dianne R. Nielson, Ph.D. Executive Director Kent P. Gray Directdr TO 168 North 1950 West P.O. Box 1,14840 Salt Lake City, Utah 84114-4840 (801) 5364100 Voice (801) 359-8853 Fax (801) 536-,1414 T.D.D. Steve Canning Utah State, Fleet Services, UST Program 1380 West North Temple Salt Lake City, Utah 84116 DATE: 4130198 FROM: William Moore RE: NON.COMPLIANCE OF UNDERGROUND STORAGE TANKS AT WEBER STATE uNrvERsrry, CAMPUS SERVICES, MOTOR POOL, 3301 UNTVERSITY CIR., OGDEN, UTAH; FACILITY ID# 1200301. To continue to maintain a valid Certificate of Compliance, the facility must be in compliance with Federal and State Rules and Regulations. A review of our records has shown that the following information is lacking: tl] Submit a properly completed form Notification Form (EPA 7530-1), notifying DERR of the changes made to the UST systems made as a result of the Installation Permit issued by DERR on February l l, 1998. This form was due within 60 days of completion of the installation, and required to be signed by the Utah Certified Installer who performed the work. tzl Submit a copy of a precision line tightness test for the lines replaced on the UST(s), performed since the new line installation. A test is required to be performed within 30 days of the replacement. t3l Although the installer indicated the replacement was completed, no Closure Plan was submitted or approval was given. Submit and obtain approval of a Closure Plan for the replacement of the piping in the above permit. t4l Submit a properly completed Closure Notice documenting the proper closure of the old piping for the USTs. The above information must be submitted to this office by 5130198.If it is not received by the date specified, we willcommence the revocation process of yourCertificate of Compliance. Continued non-compliance will result in the fees on your Certified USTs to be increased from $75 per tank to $150 per tank and failure to pay the additional fee can result in lapsing of your UST Certificate of Compliance. If you have questions concerning this matter or need any assistance, please contact William Moore at (801)536-4121. ct-osuRE FljN BB/IEW SUM!ilARY ilYeg tffo o 9FacitttY lD S Thls tacili$ Sle Namc EA Totat number ol nigUireO tanks a this site .not prwioustV 9to9eA Certrficate ol Conptidhcaissreo forthls site I I Yeg .. { . I For in'Placs c{ogrra indicatecontaminaion t ptpiect rtuager for a obrminauon i, tank can be deed in place. LUIIT Proiost fANK REMOVEH NAME Ko Crnificarion Erpiruion ciara:78 lf Yes,reviwer ffist - e** fR-/7a an *65 ENTFIES BE.OW rmiffifA SIGNIFICANT DISCFEPANCY BETWEEN THE INFOHMANON ON TI{E CLOSURE PI.AT.I AND mE mTonMAnoN N TI{E TAI{K OATA BASE E}TTHES REPFESENT tN.THE DATA BASE T.IO ENTFT FOH A PAHNCULAF TTEM MEAI.IS TI{E INFOFMANON Iil,TIE OITA IiiSE- I Address r cnY * Shte '''4- Conact TANKS TO BE CLOSED T.d( f Aee oltank CreacitY - ...,,1 l|.'.:..: -- L ",' - IStts. sbt€d Dete last used J- f. 02/L2/56 THU 11:36 FAX 601 266 1671 EWP ENGINEERING ECKHOFF, WATSON AND PREATOR ENGINEERING 3995 SourH 700 EAsr, Sum 300, SALr LAKE CrIy, UTAH 84107 Telephone # (801) 261-0090 FAX # (801) 266_t671 rd 001 6 ftPt1 hirt De P*. TO: COMPANY: FROM: SUBJECT: FAX #: DATE: EP 66EP STnTe h.Ntv LfrfiPb{Jrpttrirs &.ra Bot I 4p/b NUMBER OF PAG If not receiving clearly or having prob with cansmission, call (801) 261 ,rr-/n- LrEPfrttl hwh, ftrtruun H n tL6#Pe [nvu+ *ttti6 aee. CLD6IN6. rttE hs. / fia/1 tr€ld1 rzah.ao,iD. ffiztul i ! I .,at11 ./- "' PN-.ny.ulsw *ap ll fee srnv lAf")l3 N6r EP&W{) , Dkr Ttte z)z^ta lr,!f* ol ff, Wper W oflqt fiLLl ?Lh#a> fop rte 6Yt P l^ttLel4 ,attr W FeeN re-3illFNleV 7qL/4f weetr. goit> kaL FLEAte wrPire 7HE 4,Lb6tt€ Ptllft ,p For>ufrpl> ir ru fte t?frum|re 6/fe lWNt hEP 2 Tttnt, ,/w+ EWP ! ! 02/12/98 TEU 11:38 FAI 801 266 1671 ETP ENGINEERING UNDERGRoUND STOnAGE TANK CLoSURE PLAN kev. 0t/Ol/!t7l FAC]UTY tDf I 2003 L USE ONL Y Date Rec6i Review Date LHD App Date mailed to S @ oo2 Oats R6cei Daro Mailed to LHD Date Received F;om LHD RBvicwer/Date Approv Mgr. Reviaw K K-hols- P F Phone # lSOll 261.0O9O Closure Plan pr.par6d at the roquest of the ownar/operator (identified belowl of (company name)EWP inaarino lnc- Address 3q 5 Sorrh East-ite 300 Salt Lak6 Cirv stat6_lrl Zip 107 A Conractor may prepare this Closute Plan as the ownor/operator's ag€nt. ln preparing th6 Closuro plan, thE Contractormust act with the owner/oprlator's knowledge and app,oval, The owner/oparator -r"t "ign thc closurc plan. This closurc Plan is submitted in compliance with tha requirem€nts containad in R311-202 subpart G and R311-204(u.A.c.l FACILTTY IITFORMATION Tank Owne fa ^f I lr.h Divician a{- Srava a Phone f 18011521-2705 I I sols propristotship I I pannership I X lcorporation Addross 1380 W6st North Tamote C Sal t Lake Citv state.,llJI_ zipJl4llli_ Facillty t{ame Univers sSe ildino f)arla Contact person J.rv Jon* phona # Total numbor of regulatod undsrground tanks at this site 2 Total number of regulatod undcrground tanks at this site tgbq closed TA'{I(S TO BE CLOSED o State_lJI_zipJ&l4OL (801)26-7 94A (piping only) Tank # Date lnstalled Capacity Substance Stored' Date last operated ' lndic.rr thc tp.oinc substlncc rrorod in caoh tank to b! cros.d (rogurar, unr..d.d, dro!.r, waltc o[, .rc.r Fot wasl. oil tanker Have dagrcasing or other types of solvents be6n stored or mixsd with the waste oal? Yos (identify if known)N/A No _ Not known Analysis for load or oth€t conlaminants may be required prio, to disposal of contaminated soil or other materialwith your disposal facility.l (Check I I I I I I I I I I I 02/t2/98 TEU 11:37 FAI 601 266 1671 EWP ENGINEBRING @ oo3 TAltl( REIIOVER Name Trov Soackman q66. 6 170oo2r"Exp. datg_lulLgg_TR. Compa Wasarch Fnvtronme Phonc #lao 'l t97 Address 241rl W aliforni. A nua City Salt Lake Citv State UT Zipj4lQL_ SOIL/GROUNDWATER SAMPLEE Name Compa rD. A Cort. f GS-o21s Exp. date_!l30lgg_ Phone #1801r 261-OOqO Addrgss 3995 sourh 70o Easr- suir6 3oo city_-talil.akc-ci&_ stat8 ur zip g4io7 Belorc the clocure plan i3 submitted for lpprovel, the locEl hsElth and fire dspartmants whero lhe facilily is located muatbg Gontacted. ,l t. bcaty b h t.rt t, crrboa, tunary 6.rlLtd, crdrd, hon, K.a.. sdt L.k., s.a Jurn, w.r.ach. o, w.shit g/o,n county cohtacr DERRMSn.. (nrt 6361100 brr,...t ot th. bc.! hcd.h dktdcl- @i;ri;;Ob coNTAcr tocAl HEALTH DlsrRlcr Name o{ Dist. web.r/Moroan Hearth Disrricr Oato 2/r t /98 Contact Holoer Sass Titla Environmental Heatth lnsoector phone # (gol l 399-g43S CONTACT LOCAL FIRE DEPT. Nam€ o, D€pt.Weber State t niversitv Fir6 Deot_ Dat6 /1 0/c Contact Rooer.loh n TitlG Marshall Phone #1l 6?-722rJ DISPOSAL INFORMATION Tant(sl will be disposed at: Facility Address City Contact oerson, -____,, phone # Paoduct lina3 will sither be: X removed or _ claancd, secured in place, and capped. Vent liner will either be: _L removed or _ cleaned and secur€d open, Plping will be disposed at: Facility Arl as Ste.l State_ Zip_ Contact psrson Scal Phone # t 80tl Tank(s, will be emptied by: company N/A Phone # Tank(s) will be claaned by: company N Phone , Cont.minatad wator in th. t8nk/rinsato will be disposed at: Facility Contact parson _ phone # State.,rlll Zip_,r&llg[_ 975.9669 tt tl Tank(s) will be: - purged or - renderad inert by ih6 folowing mothod Reaidual rludgea wifl be dispossd at the toltowing facility Address ci Contact person Phone # State_ Zip l) FOR CLOSURE IN-PLACE ONLY t I Facility Site Plat, Sample lnformation Table, sample results and chain of custody forms are includ.d. I I Approval for in-prace crosure has been granted by th€ Locar Fire Departm.nt. Fire Dept._ phone Contact I I Approval for in-praca crosure has been granted by the Locar Hearth Department. H6alth District_ phone#.--_ Contac I I Substance to be used to fi tan Dato- 2 I N/A Address 38O Oranoc Street City Salt Lake Citv I 02/L2/9E TEU 11:38 FAI 801 266 1671 ETP ENGINEERING @ oo4 CO TAMINATED MATEHTALS MLTST BE DISPOSED AT AiI ACCEPTABLE FACILITY: All matcdals gencrated ftotn usT closutcs must b6 managed and dispossd in a manner that do.s not ptac6 thos6 mstarialsin dirrct contact with the environmem. on-site stoakpiling of contaminated soits may La req;";;;;;';;;';imtnag€ment activilies. AnY person Povdding ra ndiat assistance for a fec, including aeratioi and over-excavation lof morcthrn 50 ydl most be a Cenified llST Consuttant. contaminated soils genarated as pan of tank rcmoval are to be disposed at th3 following facility: Facility E.T. T looies A cite aaaessment must ba performed fot all UsT closuras and ch6ngoin-setvic6. sit€ esasssments must bs parform.d 08 outlinad in R311-202.?a 28o.72 and R311-205 [U,A.CJ. lf contamination ts susoected- additionat samotar musr baccllectad ar rhe location *here contemination is most rirerv to be rrresent. rf or,rr,rrdlatliilliEuntared. " *oir "",.nr"rr-"t b" "oll"a.d-in th",n""tu"tld .on"- in rddition to .".h orornd*rt", ""-ol*-5oiGif,!8nd,""6;;;;ffi;b. analyzod lor the compound. shown in rh€ following tabls, using the appropriete lab mettro-ds. Address 5O3O West 13OO Sor-rth 611y Salt ke Citv State ut Zip 8aro4 Contact porsoncreq t{cvilla phone #I AO,| 977-(1731 S]TE ASSESSMENT Comploto the Facility Site Pl8t lnd Sampls lnfotmation Tabls on pagos 4 and 5 to provide sit6 ass€ssmont information. COT'ITAM INATION INFORMATTON lf contamination at the facilitv is sr,lspeclsd or cg.ori@e4 the information must bc reportod to the Executive Secrsrary (UST) ar (8011 536'410o within 24 hours. The Division of wat6r ouality must be notified at {goi) s3g-6r46 if Fras product is sncountered or if surface wat€r has been impacted. lf contamination is confirmed, any person assisting in the remediationptocess for a fee must bB a Certifiad IJST Consultant 3 SUBSTANCE ANALYTICAL METHODS sorL GNOUNDWATER or SURFACE WATER Gasolin.Totll Par.olcum Hydroclrbon. lTpH) Bcnronc, Toluonc, Ethylb.nr.n., Xycn.r IBTEXI .nd MTBE 8Ol5 Modiri.d !Or1 EPA 6020 or 6240 8Ol5 Moditi.d !!il EPA 602 or 624 Oi!s!l Tot.l P.trol.um Hydroc.rbo.s ITPHI B.n..o., Tolu.n., Ethylb.nzcno, Xy'!nc., N.phth.l..t. IATEXNI 8Ol5 ModiliGd aod EPA 8O2O or a24o EOt 5 mo{rili.d l$l EPA 602 or 624 Uscd Oil Oll and Gr..!. (O&Gl or Total Rrcovcr.bl. Hydroc.rbonr {TRH} B.nzonc, Tolu.n., Ethylb.nz.n!, Xylcncr, N.phthalon. (BTEXNI Haloganltod Volatil. OrgEnio Co.npound6 IVOC'.I EPA 413.1 or 418,1 rurl EPA AOZ or 824 !O4 EPA 60l or 624 N.w Oil Oil .nd Gr...r lO&G, or Tot.l Rrcovrrabl. Hydioca,bons (TRHI EPA 4l 3.1 or 418.1 EPA 413.1 or 418.t Oth.r or Unkaown Totll P.trol.um Hydrocarbonr fiPlll B.nz.nr, Toluanc, Ethylb.nr.n.. Xylanc., Naphth.l.n. (BTEXN) H.log.n.tcd Volrlib Org.nlo Compouhdr IVOC'sl Or oth.r EPA m.thods ..b tha Ex.cutiv. S6c EOlS Moditird t!!l EPA 8O2O or 8240 BOrl EPA 8010 o. E24O E0l5 moditi.d !!( EPA 602 o. 824 l!4 EPA 60l o. 624 CONTAMINANT COMFOUNOS TO AE ANALTZEO EPA 413.1 or 418-l; 9!6[ EPA 8020 or 6240 !!d EPA Solo ot E24O 02/12/98. TEU 11:39 FAX 801 266 1671 X = Sample locations (SS-r, WS-f, USC-#l. = Monitoring Wells {MW.#,)O = Soil boring (SB-#), or Geoprobe 8oring (GP-#) O = Water Wells (domestic, livestock, etc.l Slops of Su ace Topography: IN,NW,W,SW,S,SE,E,NE) Land Use at Site: _Rcsidential _Commercial _lndustrial Surrounding Land: _8esid€ntial _Commercial _lndustrial EWP ENGINEERING Sit. Plan Musr lndiqsl€ Approximsto Localion3 ot;, Cw.eni & torm€r tanks, piping & dispensars/ Location of all samples to be taken/ Buildings, fences, & property boundariesy' Utility conduits (sewers, gas, water, sto.m drains, electrical, etc.) ld 005 FACITTTY SITE PIAT (CLOSURE PLANI The site plat must be drawn to an appropriare identified scale. lt must show planned sampling locations, subsEnces storedin tanks, and other relevant in{otmation' Tank and sample identification numbers must be consistent -ittr ttre intor-aiiongiven on p. 1 and 5 of the Closure Plan, Faciliry lD f 12001n1 Drawn By-ElAlP-Engineldnq__ Date Februarv 199g /^""r^"r 7 SAWCUT EXISTINC ASPHALT AS NEEDED REMOVE EXISTINC VENT RISERS USC- 1 Scale: t" - -Qf ect EXISTINC 5' CHAINLINK FENCS WITH SLATS I NOATH CAMPUS SERVICES BUILDINC FOR UST REMOVAL 2.OOO GALLON GASOLINE UST REMOVE REINFORCED CONCRUTE TANK PAD INSTALL ASPHALT TO GRADI: 7 LIMITS OT' CANOPY EXISTINC CONCRETE TO REMAIN IN PLACE EXISTINC C^NOPY cot.uMNS (TO REr{AlNIN PLACE) ( xlt 4.000 GALLoN DIESEL UST REMOVE EX IS1'INC 3'x 3 x4 I)lSP ENSER ISLAND _ INST^L,L CONCRETE 'I'O CRADE (INCLUDINC OOWEL f RSBAR t?' O.C.) /^rrnn .r, 4 02/!2/98 TEU 1l:39 FAI 601 266 1671 EWP ENGINEERING 14 006 SAMPLE IiIFORMATIOTIT TABLE Complstg tablo for all samples to be takcn for closur.- 1 Soll lSSl, Groundwlt.r (cW), or Unilt.d Soil Cl.ssillo.rion lUSCl, ' Approx. d.prh in t..t b.low gr.d.. Th...quit6d minimum 3it..33c!h6nt sampl.! murr bc trk.n.t G2 f.ct b.tow rh. b.ckfill/natlv. .oll inta rc!.t Contaminsnt compound. to b..n.ly:.d tor.aoh 6.mpl. (from t.bl. o^ p. 31. ' Appropriato analyeis mothods to, cont minant compound(3| in 6sch srmpl. (f,orh tabl. on p. 3). Approximat€ depth to groundwater in tho vicinity of th6 tanks:Feat. Regional groundwater flow diroction: State Ceftitied Laboratory to be used I lrilin, Y n^ I rh^..+^^, Address 875 South Chesnut S City_,Srlllateli!_ State-.lJl Zip 84125 Contact person Anne I .wis Phone #I 801 I 973-C Ploass explain any unusual or oxtenuating circumstances expocted regarding the sits assessmont or closure: Clasrrra Plan ic far roduct oioino onlv - eristino USTs to ain in olace. I certify under penalty of law thst I am the ownor/opsrstor of tho tank{sl relerenced abova and that I am familisr with the infomation on this form and thst it ls truB, acc and comploto, and lurth8r, that ths procodures described hsrsin will be followad during tank cl -<1-- Signatu16 of tank ownsr Full N6m€ of tank ownsr 5 Sample #Substance slored in tanl Sample tyPst Dcplht Compounds3 Analysis method(sla SS.1 Diesel/Unleadcd SS 3 TPH/8TEXN 8015 MOD/EPA 8020 USC.l USC Unified Soil ClassificationrII I C:\SHERRY\DGs\WSU,PLN Date I I DiaseUUnleaded 3' 08/06/96 09:38 FI\ 801,{9 8E53 DIV E\1'RESP REU UST Installat,ion/Upgrad.e permit @ ooz r)(:Iar P..El't t , P.8BiE ltor{licatloB Iarcr:'hEl'oE ca!D.!y UrO 12. tbo!. I 'oo C.rEt!1ad, Ia.tal1arrr ca p=c L 5cp-'16-Pa.srELt, Eo: Nac€D a,t)LFoL DaE,e '.rork wl_-I co[glence FaciiiEy :D* (if ::o: a -ew j.1:y! !r8l Con:acE trclll,cy Co,tt,ac-- (I:rutual 08 a=GalrrrCiEei ci8curataBc!.a r:rErocccd: lzoo t I Ulrgrade Phone I lful ; cr5 z Phoee * Total i:lsr,al,iaEton ;Tank pee/ perm!.r,zp.0u'l '; ecE;H :r- OO/6CerE. t cer'-. * Ca=:, i t ci Tank *I A Ilrsc,ai.1/UE grad€CAPGRAgF A?q?fiDE Capaclcy (ga11ons),4oe G./ec> 6. rype (PRP, SEeeI, cEc.)FR P,FRP, Substance to be Scored O/95 ill€tat PLpL::g T)fpe (gress. , Suctlon, crav:cy)P3855 Pkrs st, Ins ga1l../Upgrade whac? (Tank, Lines, C.p.,..,)/iruPs a ,I pES D..c8l.r,ctos'Tettntt IE OAl LED/UED Doq B IU,rbG i tt-o 4 A tAo azloEcza llrt]' coqllccad foa r,o:Ucah DeparE:tenc of Ervironmencal eualicy Division of ErvlronmeDcal Response and RenediaEion SEaEe Use Only: Dat,e CKtt i68 No=:h, L950 Wes--, :sE Floor r,e=;;: r^i1 ,ltii?i'Ln. ., Lt^ *re pe'*iE Mailed 4nlqo?ssss4 -- ecp. &:e 7frr,*9?-- :x:r. a,ace E:of . daEa ti I i i 1 Facility rD. # l2oo3o I z-ll-?( Michael O. lravitt Govmor Dianne R. Nielson. Ph.D. Exccuaivc Dimttr Kent P. Gray Dirtu DEPARTMENT OF ENVIRONMENTAL QUALITYi DTVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION 168 North 1950 West P.O. Box 144840 Salt [:ke City, Utah Ml 14-4840 (801) 536-4100 Voice (801) 359-8853 Fax (801) 536-4414 T.D.D.1 j ZLl tO tJ. Ca(,Qt -,'.,r. , ( e. 1t-ct uT- E4tD4 Date: From: Enclosed is the information you have requested regarding: Tank Closure Plan Tank Closure Notice Certified Tank Installers and Removers State Certified Labs Certified Tank Testers Certified Groundwater & Soil Samplers PST Fund {Other Utah UST Administrative Rules UtAh UST ACt EPA UST Regulations 40 CFR 280 Billing lnformation Release/Leak Information Musts for USTs Dollars and Sense Leak Detection Information Message: If you have any questions, please contact me at (801) 536-4121 /r-Z Underground Storage Tank Section Pnnled on Iecycled Paper @ F :\ERR\SU PPORT\U ST\FORMS\B LA N K.FRI\ASPMEMO li::r:r .!.::: i:i f' :: \,l: ...1.. . . .:.. -..,. ', il ..... ' :! ...:,i l: ir ".._.1.i ji,_,,i.,,,;i.. -, .-rj .:.. .. -' 1.' .@.&.':1.. DEPARTMENT OF E}.TVIRONMENTAL QUALITY DTVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Michael O. l*avit Govcraor 168 North 1950 West P.Q. l6a l{^{tztQ Salt lake City, Utah 841144840 (801) 5364100 Voice (801) 359-8853 Fax (801) s364414 T.D.D. Dianne R. Nielson, Ph.D. Exmtivc Dimtor Kent P. Gray Dircctor Date: From:(-) z -t-a( Dear Underground Storage Tank Owner/Operator: The Division of Environmental Response and Remediation (DERR)has received notification that one or more tanks (USTs) (tanks ) will b.@@IDupsraded)at Utah, facility ID# lZ(D?Ol regulated USTs can receive fuel and be put into operation, they must quafry for the Petoleum Storage Tank (PST) Fund and receive a Certificate of Compliance. To qualify the tanks for the Fund and receive a Certificate of Compliance or maintain your current Certificate of Compliance, you must do the following: 1. Register the changes in the tanks using EPA forrr 7530-1, Notification for Underground Storage Tanks (Enclosed). Tanks installed after December 1988 must have the following in place when installed: leak detection on tanks and piping (including automatic line leak detectors on all pressurized piping), spill and overfill devices, and corrosion protection. The Utah Certified Tank Installer must sign page 5 of the form to certify a proper installation. 2. New Tanks or Systems participating in Utah's PST fund Only: Complete the PST Application (yellow) and Previous Pollution Incidents (green) forms from the enclosed PST Fund application packet. You must indicate on the PST Application form ttre type of financial assurance you will use for your share of eligible cleanup costs for each release covered by the Fund, and declare your Financial Responsibility type(s). 3. Conduc{ a tank and line tightness tcst and send a complete copy of the results to the DERR. The tightness test must be conducted by a Utatr certified UST Tester for any new tank, line or system installed.. A list of certified UST Testers is included in the PST Fund application packet. All portions of the tank and piping system which could contain product must be tested. To receive a delivery of fuel for testing, you must contact DERR for authorization of a one-time delivery for testing purposes for new USTs. Contact the DERR office at (801) 536-4100, 24 hours in advance, to arrange for this authorization. 4. New Tanks or Systems Only: Pay UST regisfration fees. In addition tanks participating in Utah's PST Fund must pay new tank PST fees for all new tanks installed. These are: regisnation fee- $150 per tank; New tank PST Fund fee- $250 per tank. These fees must be paid before a Certificate of Compliance can be issued. When the above items are completed, send the forms, test results, and any fee payments to the DERR at the above address. When the necessry information is received, the DERR will issue a Certificate of Compliance when applicable. Timely completion of the needed forms and other requirements will facilitate the process and help you avoid loss of the use of your tanks. The Utah Underground Storage Tank Act (Utah Code Ann. 19-6401 et seq.) requires that a Certificate of Compliance be issued for new tanks before they are put into use. Please call the DERR UST office at (801) 536-4100 if you have any questions. Sincerelv.ruL_ Underground Storage Tank Section newinsrl.lE lln4r'97