Loading...
HomeMy WebLinkAboutDRC-2011-001233 - 0901a068801f7022Department of Environmental Quality Amanda Smith Executive Director DIVISION OF RADIATION CONTROL Rusty Lundberg Director State of Utah GARY R. HERBERT Governor GREG BELL Lieutenant Governor January 21,2011 CERTIFIED MAIL (Retum Receipt Requested) Ms. Jo Ann Tischler Director, Compliance and Permitting Denison Mines (USA) Corp (DUSA) 1050 17* Street, Suite 950 Denver, CO 80265 Dear Ms. Tischler: SUBJECT: January 10, 2011 DUSA Letter, Transmits Revised DMT and BAT O&M Plans, which addresses White Mesa Uranium Mill Tailings Cell 4B, etc.; January 6, 2011 DRC Letter, Review of DMT and BAT O&M Plans; Cell 4A and 4B BAT Monitoring, Operafions and Maintenance Plan (O&M Plan): Request for Information We have reviewed the subject letter from DUSA dated January 10, 2011, which is a response to the subject DRC comment letter of January 6, 2011. The DUSA letter proposes the two subject documents, noted above. However, this letter only addresses the proposed O&M Plan, as revised, known as The Cell 4A and Cell 4B BAT Monitoring, Operations and Maintenance Plan, 01/2011 Revision Denison 2.1. After review of this plan, we have the following comments with reference to the submitted redline copy: 1. On page 14, there is a proposed redlined phrase in the sentence beginning with, "Each pump is equipped with a pressure sensing transducer...," in redline it states, "for Cell 4A and 3 inches for Ceil 4B)." The "3 inches" must be changed to "2-1/4 inches (0.19 feet)," or other acceptable measurement. 2. We earlier provided this request as comment VII of our January 6, 2011 letter, regarding freeboard calculations. DUSA has chosen to propose this O&M Plan, as if Cell 4B was approved for use. a. Therefore, the secfion beginning on page 15, titled "Cell 4A Solufion Freeboard Calculafion," needs to be re-titled to "Solution Freeboard Calculations," (as this section provides freeboard calculafions for Cell 1 and 4B) or another acceptable fitle. b. The last sentence of this secfion, on page 17 needs to delete the reference to Cell 4A. 3. On page 5, paragraph d.2, there is a proposed redline change. The 18-inch diameter (proposed to be deleted) is correct in accordance with the CQA Report record drawings, and must be retained. The redline change proposed, i.e. a 2-foot inside diameter pipe is incorrect, and should be removed. 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O.Box 144850 • Salt Lake City, UT 84114-4850 Telephone (801) 536-4250-Fax (801) 533-4097'T.D.D. (801)536-4414 www. deq. utah.gov Printed on J 00% recycled paper Ms. Jo Ann Tischler Page 2 Please review the above comments, and respond in writing, submitfing corresponding complete revised copies of the subject O&M Plan, given a new and unique version number. DUSA's response time on these types of letters is left to DUSA's discrefion, in as much as the approval of the O&M Plan is a requirement for a DRC authorization for use of Cell 4B. If you have any quesfions on the above, please contact me. Sincerely, /CAV ^''^XTf ' David A. Rupp, P.E/*^ Geotechnical Services Section DAR:dr Cc: Mr. Harold Roberts, DUSA F:\0&M Plan History\RFI 01-21-2011.doc