HomeMy WebLinkAboutDRC-2011-001351 - 0901a068801f8a2cState of Utah
GARY R. HERBERT
Govemor
GREG BELL
Lieutenant Govemor
Department of
Environmental Quality
Amanda Smith
Executive Director
DIVISION OF RADIATION CONTROL
Rusty Lundberg
Director
DRC- 201 1-00 i3
January 25, 2011
Certified Mail
(Retum Receipt Requested)
Mr. Harold R. Roberts
Vice President, US Operations
Denison Mines (USA) Corp (DUSA)
1050 17*^ Street, Suite 950
Denver, CO 80265
Dear Mr. Roberts:
SUBJECT: January 21, 2011 Geosyntec Consultants Letter, DUSA Cell 4B Construction Quality
Assurance [CQA] Report Addendum; January 20, 2011 DRC Letter, Review of Cell 4B
Construction and Request for Information; Request for Information
We received the subject January 21, 2011 DUSA Cell 4B Construction Quality Assurance [CQA] Report
Addendum, furnished by Geosyntec Consultants. We have reviewed the subject addendum, and have the
following comments and requests, which generally use the same corresponding comment number as in our
subject letter of January 20, 2011:
3.b. Regarding Strip Drains, the Method to Change the Direction.
Geosyntec provided catalog copies, and a single photo showing a linear connecting fitting,
fitting location unknown.
(1) . We stated that, "There are several locations shown on the original plans requiring
the direction of the strip-drains to change. Please demonstrate the method used
with example photographs* of such use [in-place]." Although perhaps
misunderstood, our intent was to request photos* taken from on site, of such use.
Please complete this request.
(2) . We also stated that, "Numerous photographs of the strip-drain lines in Appendix
M of the CQA Report as well as some surveyed strip-drain lines in Appendix K
demonstrate strip-drain lines locations where the strip slimes drains have been
turned from their original course to "short-cut intersect" the slimes drain header
perpendicularly. Please demonstrate the method used at these locations with
example photographs* of such use as well." Geosyntec responded that, ".. .the
strip composite was simply bent to form a curve." For this item no photos were
provided. If simple bending to form a curve was used, please supply photos
demonstrating such bending.
* All photographs need to be dated, and have descriptive labels, identification of location, and background of the surroundings (to
reference the locations).
195 North 1950 West • Salt Lake City, UT
Mailing Address: P.O. Box 144850 • Salt Lake City, UT 841 14-4850
Telephone (801) 536-4250 .Fax (801) 533-4097 -T.D.D. (801)536-4414
www.deg.titali.gov
Printed on 100% recycled paper
Page 2
3.C. Specific Strip Drains Nos. 31 and 51. We requested the following:
(1). "Photographs' of reworked strip-drains 31 and 51, demonstrating no "piggy-
backing" or "fallen dominoes" type stacking of those bags." The subject
GeoSyntec response proposed photos no. 30 and 31 fulfill this requirement.
However, these photos* are not definitive as the others supplied for strip drain
documentation, due to the distant proximity of the photographs. Please complete
this request.
5. New Item. Construction Drawing Sheet 7, Section E-4,7. The non-woven cushion
geotextile covering the slimes drain header is not shown in the section drawing.
Please revise this section to show the extent and termination of the non-woven
cushion geotextile above the slimes drain header, above the slimes drain sump
piping and up the embankment above the slimes drain sump access pipe.
Please review the above comments, and respond in writing, supplying the requested documentation,
including photographs, and needed adjustments, as Addendum No. 2 to the CQA Report. The addendum
must be certified by a Utah-licensed Professional Engineer. Please include an electronic copy of the
requested information. DUSA's response time on this letter is left to DUSA's discretion, in as much as the
approval of Cell 4B CQA Report (As-Built Report) is a requirement of the Ground Water Discharge
Permit, Part 1.H.9, for DRC authorization for use of Cell 4B. If you have questions on the above, please
contact me.
Sincerely,
David A. Rupp, P.E.
Geotechnical Services Section
DAR:LBM:dr
Cc: Mr. Greg Corcoran, GeoSyntec Consultants
F:\Cell 4B\Constr\RFI 2 ConstrReview Jan-2011
* All photographs need to be dated, and have descriptive labels, identification of location, and background of the surroundings (to
reference the locations).