Loading...
HomeMy WebLinkAboutDRC-2020-013501 - 0901a06880cf6aeb-WC-202O-0050 I INSPECTION REPORT Inspection Module: Inspection Location: Inspection Items: Inspection Dates: Inspectors: Personnel Contacted: RADMOD-Training: Radiation Protection Training, Respiratory Protection Training, RSO Training, and Rad Tech Training Energy Fuels - White Mesa Uranium Mill, Blanding Utah. Annual Radiation and Respiratory Protection Training February 25, 2020 Ryan Johnson, Utah Division Waste Management and Radiation Control (DWMRC) Terry Slade, Energy Fuels Resources Radiation Safety Officer (RSO) Garrin Palmer, Radiation Safety Technician (RST) Wayne Palmer, Safety Coordinator Logan Shumway, Mill Manager Governing Documents: • UAC R313-15 • Radioactive Materials License (RML) UT1900479 • Applicable Mill procedures and manuals Opening Meeting Energy Fuels Resources: Terry Slade, Mill RSO Garrin Palmer, RST Utah DWMRC: Ryan Johnson (Health Physics Inspector) During the opening meeting, the inspector discussed the inspection items and documentation to be reviewed during the inspection. The main portion of the Mill was not in operation during this inspection. The Mill staff reminded the inspectors of the safety requirements for the Mill. DRC Meters Used Model Serial Number Calibration Due Date Dose Rate Ludlum 19 101673 05/13/20 Inspection Summary The inspection consisted of an RSO interview, reviewing applicable documentation, observing the Mill's Annual Radiation Safety/Respiratory Protection refresher training and a mill tour. The following discussion provides more detail of the specific items reviewed. 1 of Page 4 \\Cbwfp2\shw\Shared\RAD\COMMONNUranium mills \UTI900479 EnergyFuels Res - White Mesa UMill \HP Inspection modules\2020\2020 Inspection Reports\Inspection Report RADMOD-Training 02-28-20.docx Item 1. Mill Tour: The Inspector walked through the restricted area on a general site tour. The tour included the ore pad, the mill, the alternate feed circuit, and the SX building. Observations: The DWMRC inspector observed: • Proper PPE was being worn by Mill employees within all observed areas of the Mill; • Proper Radiological Posting were being used within all observed areas of the Mill; and • OSL badges were appropriately being used by all observed employees at the Mill; Radiolo ical readin s observed durin Mill tour Location Dose Rate (i.tR/hr) Alternate Feed Circuit 28 Product Yard 60 Ore Pad 100-300 Solvent Extraction 50 Mill 100 Deficiencies: None Item 2. Documentation Review: The Inspector reviewed applicable documentation. Observations: The DWMRC inspector reviewed: • Training documents for contractor and new hire training from 2019. These documents included: o Radiation Safety and Respiratory Protection Exams; o Initial/Refresher Training as documented on the MSHA form; o Personnel Monitoring; o Medical Clearance; and o Fit Tests. • The Inspector also obtained copies of: o The 2020 exams; o The 2020 radiation safety training outline; o White Mesa Mill's contractor radiation safety training; and o The 2020 training schedule. Deficiencies: None Item 3. RSO Interview: Observations: The DWMRC inspector discussed the following with the Mill's RSO: The Inspector and the RSO discussed the training that the RSO and the Radiation safety techs would be receiving this year. The Inspector also reviewed the training certificates of the RSTs and obtained copies of Garrin Palmers training certificate because he is the RSO's designee when the RSO is not present. The RSO and all of the RSTs have been appropriately trained and have relevant additional training for their positions. Examples of training that they have had include: • Radiation Safety Officer Training (RSO and Designee); • Transportation of Radioactive Material (Radiation Safety Staff); • Dosimetry (Radiation Safety Staff); and • Instrumentation (Radiation safety Staff). The Inspector determined that the training received by the Radiation Safety Staff is appropriate for the jobs and has been done at the appropriate refresher intervals. The Inspector also interviewed the safety 2 of Page 4 \\Cbwfp2 \shw\Shared\RAD\COMMON\Uranium mills\UT1900479 EnergyFuels Res - White Mesa UMill\HP Inspection modules \2020 \2020 Inspection Reports \Inspection Report RADMOD-Training 02-28-20.docx Recommendations None Recommendation for Next Inspection None Prepared By: Reviewed By: 3 -g--202o (Date) 3 ?6•20. (D t ) coordinator to discuss contractor training. Deficiencies: None Item 4. Annual Refresher Course: The Inspector observed the annual Radiation Safety and Respiratory Protection refresher training. Observations: The DWMRC inspector observed: • The Mill Manager discussed: o President Trumps decision on Uranium; and o Company policies on working hours, lunch times and cell phone use. • One of the Mill's Radiation Safety Technician discussed Storm water training: o If a spill occurs: • Clean it up. Using dry methods whenever possible; • Document the spill using pictures and the "orange" cards; and • Preventing spills is the best policy. • The RSO Discussed the following: o Discussed 20 1 9 employee exposure and what that exposure means; o Relevant topics from NRC Reg. Guide 8.3 1 section 2.5; o How to reduce exposure: Time, Distance and Shielding. Examples were discussed on how time distance and shielding is used at the Mill; o Posting requirements: What is a radiation area, an airborne area and a contamination area are and what is required in each area; o Characteristics of Alpha, Beta and Gamma Radiation. Deficiencies: None Closeout Meeting Energy Fuels: Terry Slade (RSO) Garrin Palmer (RST) Utah DWMRC: Ryan Johnson (Health Physics Inspector) Findino None 3 of Page 4 \\Cbwfp2\shw\Shared\RAD\COMMON\Uranium mills \UT1900479 EnergyFuels Res - White Mesa UMill\HP Inspection modules\2020\2020 Inspection Reports\Inspection Report RADMOD-Training 02-28-20.docx 4 of Page 4 \\Cbwfp2\shw\Shared\RAD\COMMON\Uranium mills\UT1900479 EnergyFuels Res - White Mesa UMill \HP Inspection modules \2020 \2020 Inspection Reports\Inspection Report RADMOD-Training 02-28-20.docx