Loading...
HomeMy WebLinkAboutDRC-2020-012768 - 0901a06880ce3f61 DRC-2020-012768 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144880 • Salt Lake City, UT 84114-4880 Telephone (801) 536-0200 • Fax (801) 536-0222 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah GARY R. HERBERT Governor SPENCER J. COX Lieutenant Governor Department of Environmental Quality L. Scott Baird Executive Director DIVISION OF WASTE MANAGEMENT AND RADIATION CONTROL Ty L. Howard Director July 28, 2020 Kathy Weinel, Quality Assurance Manager Energy Fuels Resources (USA) Inc. 225 Union Blvd., Suite 600 Lakewood, CO 80228 RE: Energy Fuels Resources, White Mesa Uranium Mill July 13, 2020 Request to Return Certain Groundwater Monitoring Parameters to Baseline Monitoring Frequency. Utah Groundwater Discharge Permit No. UGW370004 Dear Ms. Weinel: The Division of Waste Management and Radiation Control (DWMRC) has completed review of the Energy Fuels Resources (USA) Inc. (EFR), July 13, 2020, State of Utah Ground Water Discharge Permit No. UGW370004 White Mesa Uranium Mill – Removal of Certain Groundwater Monitoring Parameters from Accelerated Monitoring Status. Based on review of the EFR July 13, 2020 Request, EFR requests that certain monitoring well parameters be returned to baseline monitoring as listed on the table below: Monitoring Well Parameter Number of Consecutive Sample Results Below the GWCL Baseline Monitoring Frequency MW-14 Fluoride 9 Quarterly MW-14 Sulfate 9 Quarterly MW-26 Methylene Chloride 11 Quarterly MW-35 Ammonia 8 Semi-Annual MW-36 Sulfate 9 Quarterly (Over) It was noted per review of groundwater monitoring data, including laboratory data sheets included with the EFR July 13, 2020 request, that the above monitoring well parameters have had sample results below the Permitted Ground Water Compliance Limits (GWCLs) for the most recent eight consecutive accelerated sampling events or more. Per past DWMRC protocols, accelerated monitoring may be discontinued if at least eight consecutive samples show concentrations below the GWCL. Therefore, the request to return to baseline monitoring for the wells/parameters on the table above is hereby approved. If you have any questions, please call Tom Rushing at (801) 536-0080. Sincerely, Phil Goble, Uranium Mills and Radioactive Materials Manager Division of Waste Management and Radiation Control PRG/TR/as c: Kirk Benge, Health Officer, San Juan Public Health Department Rick Meyer, Environmental Health Director, San Juan Public Health Department Russell Seeley, UDEQ District Engineer