HomeMy WebLinkAboutDRC-2021-017941 - 0901a06880f940022.02.1 - DO% -1
RMINSPECTION REPORT
Inspection Module: RADMOD-PEM: Surveys/Posting/Exit Monitoring
Inspection Location:. Energy Fuels - White Mesa Uranium Mill, Blanding Utah.
Inspection Items: Radiological Postings, Routine Surveys and Employee Exit Monitoring
Inspection Date: September 7 & 8, 2021
Inspectors: Ryan Johnson, Utah Division of Waste Management and Radiation Control
(DWMRC)
Personnel Contacted: Garrin Palmer, Radiation Safety Officer (RSO)
Justin Perkins, RST
Governing Documents:
• UAC R313-15
• Radioactive Materials License (RML) UT1900479
• Applicable Mill procedures and manuals
Opening Meeting
Energy Fuels Resources:
Garrin Palmer (RST)
Utah DWMRC:
Ryan Johnson (Health Physics Inspector)
During the opening meeting, the inspectors discussed the inspection items for the inspection. The Mill staff
reminded the inspector of the safety requirements for the Mill.
DWMRC Meters Used Model Serial Number Calibration Due Date
Dose Rate Ludlum 19 101673 5/11/2022
Contamination Ludlum 3002 25017719 9/17/2021
Inspection Summary
The inspection consisted of:
• Observing radiological postings around the Mill;
• Observing Mill personnel perform exit surveys:
• Reviewing documentation of:
o Weekly Alpha surveys;
o Monthly Gamma surveys; and
• Taking dose rate and contamination measurements around the Mill.
The following discussion provides more detail of each inspection items.
Item 1. Radiological Postings:
Observations: During the Mill Tour the inspector observed the following posted areas:
1 of Page 4
\\Cbwfp2\shw\Shared\RAD\COMMON\Uranium mills\UT1900479 EnergyFuets Res - White Mesa UMill \HP Inspection modules\2021\2021
Inspection Reports \Inspection Report RADMOD-PEM 9-8-202 I.docx
Posting Locations Observed Postings Observed Dose Rates
Yellowcake Storage Area , Caution Radiation Area 4,000 µR/hr (Inside area)
Laboratory Caution Radioactive Materials 60 pR/hr
Laboratory Sample Storage (aka
Balance) Room
Caution Radiation Area 80 µR/hr
Doors leading to the restricted
area from the Administration
building
Any Area within this Mill May
Contain Radioactive Material
Not Measured
Sample Preparation Room Caution Airborne Area 60 µR/hr
Perimeter fence Caution Radiation Area Not Measured
Perimeter gates Any Area within this Mill May
Contain Radioactive Material
Not Measured
Ore Pad No Posting 100-300 µR/hr
Mill No Posting 50-150 µR/hr
Solvent Extraction Building No Posting 60 µR/hr
Scale house No Posting 125 µR/hr
Lunchroom No Posting 35 pR/hr
Lunchroom #2 No Posting 25 µR/hr
Note: Due to no uranium production at the time of the inspection there are fewer posted areas in the Mill.
The Inspector also collected large area swipe samples in six areas within the restricted area.
Location Alpha (dpm/100cm) Beta (dpm/100cm2)
Scale House Below Background Below Background
Lunch Room 1 Below Background
Lunch Room #2 1 Below Background
Locker Room Below Background Below Background
Sample Prep Room 11 6
Control Room 1 3
Deficiencies:
None
Item 2. Exit Surveys: The Inspector observed employees survey themselves out of the restricted area and
checked the alpha metersused.
Observations: The Mill uses Alpha scintillators for exit surveys. The Inspector checked the settings of the
survey instruments and found that they were set properly. Meters are calibrated annually. The Mill
personnel that were observed performing exit surveys, did the surveys appropriately. The Mill's RSTs also
perform random checks on exit surveys.
Meter Location Model Meter Serial # Probe Serial # Cal. Due Alarm
Setting
West Admin Door Ludlum 177 322833 PR342603 3/4/2022 80
East Admin. Door Ludlum 177 322900 PR359856 3/2/2022 80
Lab Admin Door Ludlum 177 185038 RN17632 11/12/2021 80
Lunch Room Ludlum 177 265743 RN16489 9/23/2021 80
Lunch Room #2 Ludlum 177 159170 PR192467 3/4/2022 80
2 of Page 4
\\Cbwfp2 \shw\ Shared\RAD\ COMMON \Uranium mills\UT1900479 EnergyFuels Res - White Mesa UMill \HP Inspection modules\2021\2021
Inspection Reports \Inspection Report RADMOD-PEM 9-8-2021.docx
(Date)
Recommendation for Next Inspection
None
Prepared By:
Reviewed By:
9/10/2021
East Decon Gate Ludlum 177 159117 PR16489-1A 3/3/2022 80
Deficiencies: None
Item 3. Radiological Surveys and Monitoring: The Inspector reviewed the weekly surveys done around
the Mill.
Observations: The Inspector reviewed the radiological monitoring documentation performed at the Mill
site. The documentation indicated that:
• All areas of the Mill are being survey for radiological conditions;
• Surveys indicate that the Mill is being maintained within regulatory radiological parameters
• Documentation is legible, complete and using appropriate units; and
• "Clean" areas are being maintained.
The Inspector also looked at dosimeter usage. The inspector observed:
• Mill personnel were properly wearing their dosimeters on the torso of the their bodies;
• Dosimetery was being properly stored in the locker room and administration building; and
• Each employee is assigned a dosimeter.
Meter Type Model Meter Serial # Probe Serial # Cal. Due Meter
Condition
Alpha Scintillator Ludlum 3 235288 PR281511 8/25/2022 Good
Side Window G/M Ludlum 3 337582 RN24946 6/8/2022 Good
Alpha Scintillator Ludlum 2200 17534 43-10 8/24/2022 Good
Closeout Meeting
Energy Fuels:
Garrin Palmer (RST)
Utah DWMRC:
Ryan Johnson (Health Physics Inspector)
Recommendations
None
3 of Page 4
\\Cbwfp2\shw\Shared\RAD\COMMON\Uranium mills\UT1900479 EnergyFuels Res - White Mesa UM111\HP Inspection modules\2021. \202I
Inspection Reports \Inspection Report RADMOD-PEM 9-8-2021.docx