Loading...
HomeMy WebLinkAboutDRC-2016-003101 - 0901a06880602a68State of Utah GARY R. HERBERT Governor SPENCER J. COX Lieutenant Governor Department of Environmental Quality Alan Matheson Execatiye Director DIVISION OF WASTE MANAGEMENT AND RADIATION CONTROL Scott T. Anderson Director February 19,2016 Kathy Weinel, Quality Assurance Manager Energy Fuels Resources (USA) Inc. 225 Unron Blvd., Suite 600 Lakewood, CO 80228 RE: Energy Fuels Resources (USA) Inc. December 9, 2015, Transmittal of Source Assessment Report for Monitoring Well MW-31, White Mesa Uranium Mill Groundwater Discharge Permit No. UGW370004 Dear Ms. Weinel: The Division of Waste Management and Radiation Control has completed its review of the Energy Fuels Resources (USA) Inc. December 9,2015 document titled Source Assessment Reportfor MI4r4l White Mesa Uranium Mtl/ (SAR). The SAR includes assessment of selenium, sulfate, TDS and pH in monitoring well MW-31. Based on review of the SAR, there appears to be no clear indication that mill tailings solution is causing the parameter exceedances and increasing concentration trends in monitoring well MW-31. This is based on the Division's review of site data, related groundwater studies, and the SAR. Therefore, the Division agrees that review of monitoring well MW-31 data and modification of the GWCLs for selenium, sulfate, TDS and pH is appropriate. Based on review of the SAR section regarding proposed modifications to the GWCLs and statistical analysis of the data and a telephone conference with Division representatives and EFR representatives on February 11,2016, it was agreed that the GWCLs will be modified in the White Mesa Uranium Mill Ground Water Permit as summarized on the table below. Well Number Parameter/units Current GWCL Modified GWCL Method of Analvsis MW-31 Selenium hElL\79 86.81 Mean * 2o MW-31 Sulfate (me/L\552 697.60 Mean * 2o MW-3r pH (standard units)6.s7 - 8.5 6.23 -8.5 Lowest Historic Value MW-31 TDS (me/L)1410.57 1700 Hiehest Historic Value 195 North 1950 West. Salt Lake City, UT Mailing Address: P.O. Box 1,14880 . Salt Lake City, UT 84114-4880 Telephone (801) s36-0200. Fax (801) s364222. T.D.D. (801) 5364414 wuna.ileq.utah.goo Printed on 1007o recycled paper DRC-2016403101 (Over) If you bave any questions, please call Tom Rushing at (801) 536-0080. Sincerely, Scott T. Anderson, Director Division of Waste Management and Radiation Contol STA/TRlka c: Worttry Glover, Jr., MMHRM, CPlvf, Health Officer, San Juan Public Health Departrnent Rick Meyer, Environmental Health Director, San Juan Public Healttt Deparfrtent