Loading...
HomeMy WebLinkAboutDRC-2015-001726 - 0901a0688050e92eENERGYFUELS Energy Fuels Resources (USA) Inc. 225 Union Blvd. Suite 600 Lakewood, CO, US, 80228 303 974 2140 www.energyfuels.com March 13, 2015 VIA PDF AND EXPRESS DELIVERY DRC-2015-001726 MAK 1 3 2015 Mr. Rusty Lundberg Division of Radiation Control Utah Department of Environmental Quality 195 North 1950 West P.O. Box 144850 Salt Lake City, UT 84114-4820 Re: Stipulated Consent Order Docket No. UGW12-04, Regarding Energy Fuels Resources (USA) Inc. May 7,2012 Corrective Action Plan ("CAP") for Nitrate, White Mesa Uranium Mill, Dear Mr. Lundberg: Pursuant to our teleconference on March 3, 2015, Energy Fuels Resources (USA) Inc. ("EFRI") is submitting the As-Built drawings for the Ammonium Sulfate Cover specified in the Nitrate CAP, dated May 7, 2012. The attached As-Built drawings in Attachment 1 show the work completed to date. EFRI submitted the design drawings for the work completed to date on October 3, 2014. DRC approved the design on October 16, 2014 and EFRI submitted the installation notification on November 6, 2014. As requested during the March 3, 2015 teleconference, EFRI is also submitting the design for the concrete cap for the existing concrete pad directly under the ammonium sulfate tanks. This design was not included in the previous submissions and is being submitted at this time for your review and approval. The design is included in Attachment 2. Upon receipt of DRC approval, EFRI will complete the concrete capping activities within 60 days of approval. Any schedule changes will be approved by the Director. EFRI will provide DRC with at least fourteen calendar days notice for the construction of the cap. It is important to note that the Nitrate CAP stated that a curbed concrete pad would be installed in the ammonium sulfate tank area. Due to the significant expansion of the concrete in the area, the curb is no longer practical and would interrupt and interfere with the drainage system and as such the curb initially contemplated has been removed. Please contact the undersigned if you have any questions or require any further information. Yours very truly, ENERGY FUELS RESOURCES (USA) INC. Kathy Weinel Quality Assurance Manager cc: Harold R. Roberts David E. Turk Dan Hillsten Scott Bakken Attachment 1 PRFCiSi O N SYSTEMS E N G i N e: E R , N C-. D RAWING AND DOCUMENT TRANSMITTAL Date: March 11, 2015 PSE Job No. 2014142 Transmittal No.:14142-TRANS-008 To: Energy Fuels Attn: Steve Snyder 6425 S Highway 191 Blanding, UT 84511 Email: ssnvder@enerEvfuels.com RE: Concrete Pad Design CODE: (1) FOR APPROVAL (2) REVISED FOR APPROVAL (3) APPROVED FOR FABRICATION OR CONSTRUCTION (4) REVISED FOR FABRICATION (5) REVISE AND RESUBMIT (6) FOR QUOTE/BID PURPOSES ONLY (7) FOR REVIEW (8) FOR INFORMATION ONLY (9) PRELIMINARY (10) CONFIDENTIAL (11) PERMITTING (12) AS-BUILT NO. OF PRINTS DOCUMENT NO. REV. SHT. NO. CODE TITLE 14142-C-100 10F2 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT SITE/GRADING PLAN 14142-C-100 2 OF 2 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT SITE/GRADING PLAN 14142-C-200 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE SECTIONS 14142-C-201 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE SECTIONS 14142-C-202 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE DETAILS 14142-C-210 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE SECTIONS & DETAILS 14142-C-211 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE DETAILS AND SECTIONS 14142-S-100 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT PIPE RACK PLAN AND ELEVATION 14142-S-110 12 AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT PIPE RACK DETAILS NOTE: AS-BUILTS AS PER CLIENT'S REDLINES. THEY HAVE NOT BEEN VERIFIED BY PSE. COPY OF TRANSMITTAL TO: SHIPPING TRANSMITTED BY: Noe Casalino (db) FILE FORMAT: Via: Email PLEASE ACKNOWLEDGE RECEIPT OF DOCUMENTS BY RESPONDING TO THE EMAIL. PDF File: 14142-Trans-008 9805 South 500 West / Sandy, Utah 84070 Telephone: (801)943-5555 / Fax (801)943-5922 lof 1 REGRADE ROAD AS SHOWN EXISTING CONCRETE (TO REMAIN) EXIST DECON PAD EXIST. 30" DRAIN PIPE RECONSTRUCT TO NEW DECON TANK IE=5645 25' AT DECON PAD PIPE AND PIPE SUPPORTS (BY OTHERS) REGRADE BERM AS SHOWN 1018033S 18 BTUOFSUhP N PNT#1 - EXIST CURB A Op 08 PNT A PNT PNT #49 A A NEW 4' x 4' x 4' DEEP SUMP RIM EL = 5637 25 NEW CONCRETE PAVING SEE a± \J4142-C-202 i 10" THICK CONCRETE 8 THICK CONCRETE SLAB (TRAFFIC AREA) I SLAB (NON-TRAFFICE AREA) S8< SEE DETAIL '5" ON SEE DETAIL "ff ON DWG 14142-C-202 I DWG 14142-C-202 PNT #4 A LiMrrs OF CONCRETE PAVING 14142-C-202 Op PNT #48 EXISTING ASPHALT (TO REMAIN) PNT PNT #50 EXIST PNT #21 DOORWAY A NEW DECON TANK 43'-0- x S'-e- FOUNDATION FOR TANK RELOCATION PNT #47 PNT #6 PNT #7 PNT #26 REF NEW 42*-0-x8'-6" DECON TANK (BY OTHERS) hr PNT #20 —' PNT #52 1 1 PNT #22 A PNT #19 \j4i4; Point Table Point Table 14142C-201 E—tTQ EatAra Ducripfa Pontf PNT #25 PNT #23 PNT#24 14142-C-201 B64O00 10166411.34 221044918 5637 06 10166334.36 2219634J1 TOC V414; 1016540001 2210444 71 3637 66 10166336.75 2210406 73 BLDQ COR NEW 4 x 4 x 4 DEEP SUMP 2210440M 5637 60 10166261 JB 2218670 10166384 11 PER FNDN 14142-C-200 6837 00 10165291 221967006 2219409JB PER FN ON SLOPE FLOOR TOWARDS SUMP ^41 5637 00 10166291 JB 2219660M 6637 36 10166346 9B PER FNDN A 5637.60 10165291JB 2219560J6 10166347J5 2219417.08 PER FNDN 14142-C-200 10166291 JB 221950296 5637 31 10166337 93 221941641 PER FNDN 10166291J9 2219496J6 NEW VALLEY GUTTER 5636J6 PER FNDN PER FNDN 1 EXIST 29*-6"0 CONCRETE \ FOUNDATION FOR 2219602JK 101662B1J9 PER FNDN EXIST BLDG PNT #43 5637JS 10165349 92 2219431J7 SUMP PNT #40 | 28*-O"0 ACID TANK 2219427J7 BUMP PNT #41 TOC TANK FON 2219618.40 664000 10166387.87 TOC TOC TANK FDN 10166346.69 2219672JB A 6640J4 10166300.87 ZZ19617JB TOC TOC TANK FDN 10166346.08 PNT #44 — 10166336.69 2219617JO A 5840 PNT #45 5632.75 2219674J1 N EXISTING CONCRETE TOC A 5830.75 MATCH L NE - SEE DWG 14142-C-100 SHT 2 OF 2 PNT #42 - + - -I V- PNT #39 -PNT #46 64' A LEGEND EX 1' CONTOUR EX 5' CONTOUR PROP V CONTOUR PROP 5" CONTOUR ANEW ACID TANK 60' x 95' CONCRETE SLAB WITH PERIMETER CONTAINMENT WALL -TOP OF CONTAINMENT WALL EL = 5641 00' PIPE RACK BRIDGE SEE DWG 14142-S-100 DWG No REFERENCE DRAWINGS •SUED AS WLT, RBKWB) PWT 103 CHAWED COCfOMAIZS 1ELfVATOM ADDS P« BnDOC DETAU AHO QBCftAL CHAMES TO HM REVISIONS SSUE RECORD ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT SITE/GRADING PLAN BLANDING, UT 1--10T PROJECT NO 2014142 CAD NO 14142-C-100 1 OF 2 14142-C-100 CAST CONCRETE SLAB UP TO AND AGAINST ACID TANK RINGWALL PROVIDE IMPERMEABLE/ ACID RESISTANT SEAL, BELZONA 4181 OR SIMILAR LEGEND 10" THICK CONCRETE SLAB (TRAFFIC AREA) 8 THICK CONCRETE SLAB (NON-TRAFFIC AREA) / EXIST 29'-6"0 CONCRETE \ EX. 1' CONTOUR EX. 5' CONTOUR PROP 1' CONTOUR PROP 5' CONTOUR N FOUNDATION FOR 28'-O"0 ACID TANK (j414 SEE DETAIL'S1 ON DWG. 14142-C-202 SEE DETAIL '51 ON DWG 14142-C-202 14142-C-200 I 1 NEW ACID TANK 80' x 951 CONCRETE SLAB WITH PERIMETER CONTAINMENT WALL E3 — NEW VALLEY GUTTER i 1 A MATCH LINE - SEE DWG 14142-C-100 SHT 1 OF 2 7 A A EX ST CONCRETE SKIRT TOP OF CONTAINMENT WALL EL = 5641 00' '( EXIST 29'-6"0 CONCRETE \ / FOUNDATION FOR 28'-O"0 ACID TANK 14142-1 -201 NEW CONCRE1E PAV SEE (j4i)r — BLDG CORNER -14142-C-2tXT — PNT #35 A ( EXIST CONCRETE RAMP \ (TO REMAIN) PNT #36 14 42-C202 PNT #27 REF L EXIST SD CATCH BASIN RECONSTRUCT 4'x4'x4'DEEP CATCH BASIN EX RIM EL = 5637 23 EX IE = 5635 33 NEW RIM EL = 5637 23 NEW IE = 5635 33 5 fig PNT #37 NEW EAST VALLEY GUTI ER in fx to? = < REGRADE BERM AS SHOWN -. O PNT #34 PNT #38 1-201 J 5640 4142-C-202 14142-C-201 PNT #28 =1 LIMITS OF CONCRETE PAVING SD SD SD SD SD 4142-C-201 EXIST FIREHOSE STATION CONC SLAB TO POND — PNT #30 PNT #29 A ^1414 REGRADE AREA (SLOPE TO NEW VALLEY GUTTER) NEW STORM DRAIN LINE RIPRAPD50=12" NON-DEGRADABLE 14142-C-201 PNT #33 A LIMITS OF RIP RAP AS REQUIRED LIMITS OF CONCRETE PAVING A EXIST ASPHAL Point Table A LIMITS OF CONCRETE PAVING PNT #51 Pont* EbMJJon En6no 5837.32 2219496,46 HATCH EXIST PNT #32 A 583703 101WZ1UB 221 SOW VALLEY GUTTER 10166203.94 2219625 10 VALLEY OUTTER 5040.15 10165187.34 2210565JO 5640 15 10165203.94 2219571.91 6640.15 10166216 04 2219571JM 5637JO 1016523036 2219574.21 TOC 5637.23 10165239 36 221963421 TOC 5640.00 1016523&52 2219007J3 564000 10165225.06 2219607JB 5639.00 10166187.44 2219619 77 A 88UEDA3 BUB.T HEW8ED ELEV Q PWT M REMWEDPMT 164 CHAMED COOONATT31EUEVAT10M NO BY CHD H9 DATE ISSUE RECORD COMBTRUCTCN ENG MANAGER ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT SITE/GRADING PLAN BLANDING, UTAH ivrj* PROJECT NO 2014142 CAD NO 14142-C-100 2 OF 2 14142-C-100 10" 4" VA" CHAMFER AT EXPOSED CORNERS (2)-#4 CONT TOP 10 C I P CONC WALL #4 HORIZ AT 12" OC CONT WATER STOP (PVC TYPE I) 1-6 (LAP) 06 AT 12 EW (2)-04 CONT BTM CONT 2x4 KEYED JT 5 (2)-#6 VERTICAL AT 12" OC (BENT) 3 -0 (LAP) #6 AT 12 OC (BEND AS SHOWN) 3 -0 HOOK LAP f6 AT 12 OC BTM 5-2 3" THICK CONC SLAB W/ #4 AT 10" EW (SEE PLAN FOR EL) CONCRETE (WHERE OCCURS) FINISHED GRADE (ELSEWHERE) (SEE PLAN FOR ELEVATIONS) SECTION 3/4"=1'-0" \14142-C-100 SHT 1 3- 9'-6" WIDE x 43-0" LONG DECON TANK (BY OTHERS) ^CONCRETE OVER FINISHED SUBGRADE (SEE PLAN FOR ELEVATIONS) L 6 TYP 04 LONG C» 22 ± OC TOP& BOTTOM #4 STIRRUPS AT 24" OC i |4 TRANSVERSE 0 24" OC TOP 4 BOTTOM SECTION fa 3/4"= r-o" 14142-C-100 SHT 1 NOTES: 1 SEE DRAWING CSD001 AND CSD002 FOR STANDARD GENERAL CONCRETE NOTES 2 COMPACT NATIVE SOIL TO 95X MAXIMUM DRY DENSITY WITHIN PROJECT BATTERY UMfTS IF CLAY IS ENCOUNTERED, OVER EXCAVATE TO 12" AND REPLACE WITH ENGINEERED FILL 3 ACID TANK CONTAINMENT CHAMBER (AS SHOWN IN SECTION A, THIS SHEET) TO BE SULPHATE RESISTANT TYPE V CONCRETE ALL OTHER CONCRETE TO BE TYPE II 4 ENGINEERED FILL CLEAN, NON-ORGANIC, GRANULAR, MINERAL SOIL FINES TO BE NON-EXPANSIVE, NON-COLLAPSIBLE MAXIMUM PLASTICITY INDEX = 12% GRANULATION AS FOLLOWS SIEVE % PASSING 1" 100% ±0 J4" 85% ±10% #4 55% ±10% 016 31% ±8% 0200 9% ±3% 3/8/15 9/22/14 ISSUED AS EULT REMOVED rciAimc mi PPM. REVTSB) ifcUM B REVISIONS » BY Oft APP am REVISIONS fesuE RECORD OEC CHECK INST CHECK STRUCT CHK CHECKED ENG MANAGER ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE SECTIONS BLANDING, UTAH 3/4" = 1'-0" PROJECT NO 2014142 CAD NO 14142-C-200 14142-C-200 ADJACENT CONCRETE PAVING - (SEE PLAN FOR REINF) 2" CLR 15-0" 04 TRANSVERSE AT 18" OC -12" THICK CONC VALLEY GUTTER (SEE PLAN FOR LOCATION ANO EL) 04 CONT LONG AT 18" OC ADJACENT CONCRETE PAVING (SEE PLAN FOR REINF) HIGH POINT (AT OUTTER EDGES) SEE PLAN FOR EL aOW UNE AT CENTER OF GUTTER SLAB REINFORCEMENT 12" THICK CONC VALLEY GUTTER (SEE PLAN FOR LOCATION AND EL) - RIP-RAP (SEE PLAN FOR SIZE AND EXTENTS) SECTION 3/4"= r-o" \J4142-C-100 SHT 2 SECTION 3/4"= r-o' 14142-C-100 SHT 2 ADJACENT CONCRETE PAVING- (SEE PLAN FOR REINF) 2" CLR 15-0" -12" THICK CONC VALLEY GUTTER (SEE PLAN FOR LOCATION AND EL) 04 TRANSVERSE AT 18" OC u04 CONT LONG AT ±18" OC SECTION {T 3/4"= 1'-0" \14142-C-100 SHT 2 - RIP-RAP (SEE PLAN FOR SIZE AND EXTENTS) 1'-6' 1/4" LU4MJ5W FRAME " MITER CUT 4 WELD CORNERS 0-0 12 THICK CONC VALLEY GUTTER (SEE PLAN FOR LOCATION AND EL) ADJACENT ASPHALT PAVING ADJACENT ASPHALT PAVING 04 TRANSVERSE AT 18 0 C 04 CONT LONG AT 18 OC 2 CLR VJ4142-C- SECTION NTS 100 SHT 1 J$"«4" WELDED STUDS912"0C (MAX) WELDED TO ANGLE FRAME 06 0 12" OC BEND AS SHOWN OTxrV BAR GRATING " SUPPORT ANGLE - METAL= L4X3XK LLV F1BERGLASS=L3X3X^ 6-2 DETAIL 1-1/2" = 1-0VJ4142-C-100 SHT 1 -04 HOR 0 12" 0 C -CONT WATER STOP PVC TYPE I -CONT 2 x4 KEYED JOINT - %'» x 6" LG WEDGE ANCHOR AND WASHER 918'OC, 1^" PROJECTION -(2) 06 VERT 0 12" OC BENT -06 0 12" OC BOTTOM NOTES- 1 SEE DRAWING CSD001 AND CSD002 FOR STANDARD GENERAL CONCRETE NOTES 2 COMPACT NATIVE SOIL TO 95X MAXIMUM DRY OENSITY IF CLAY IS ENCOUNTERED, OVER EXCAVATE TO 12" AND REPLACE WITH ENGINEERED FILL DWG No RT¥ERENCE btwBNcT" Wis 9/22/14 0/29/1' ADDED SCCnCN H RO40VED VAlifY GUTTER DETAL CHAHCED DETAJL I REVISIONS HO n cm APP DATE REVISIONS ELEC CHECK INST CHECK STRUCT CHK DRAWN CHECKED ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE SECTIONS BLANDING, UTAH = 1-0 SCAIE 3/4" = PROJECT NO 2014142 CAO NO 14142-C-201 14142-C-201 4-0" II M 11 II II II I TTTT 4-0" TYP #4 0 12"± OC BEND AS SHOWN DETAIL 3/4" = 1-0" 14142-C-100 SHT 2 2" CLR "L 4x4x>2 NOTE DETAIL MAY BE SUBSTITUTED WITH STD PRECAST STORM DRAIN BOX, OLDCASTLE, DURACRETE, OR EQUAL SEE PLAN FOR PLACEMENT ELEVATIONS ±4'-6fc" (SQ) fyiii 38-W-4 HEAVY TRAFFIC GRATING )S"0X4" WELDED STUDS012"OC (MAX) WELDED TO ANGLE FRAME -04 0 12"± OC 2" CLR TYP Ml II M DETAL 3/4" 1-0" 14142-C-100 SHT 1 100-0 MAXIMUM DISTANCE BETWEEN COLD JOINTS (TYP) 04 0 12"± OC BEND AS SHOWN NOTE DETAIL MAY BE SUBSTITUTED WITH STD PRECAST STORM DRAIN BOX, OLDCASTLE, DURACRETE, OR EQUAL SEE PLAN FOR PLACEMENT ELEVATIONS 4x4*!$ ±4"-6>4" (SQ) 38-W-4 HEAVY TRAFFIC GRATING J$"»X4" WELDED STUDS012"OC (MAX) WELDED TO ANGLE FRAME 12"± OC SLAB COLD JOINT SAW CIT SLAB JOINT (TYPI>L 0 UN SLAB COLD JOINT MAXIMUM BETWEEN SAW CUT SLAB JOINTS (TYPICAL) SAW-CUT OR COLD JOINT (TYPICAL) SEE^ VJ4142-C-202 PROVIDE i" GAP IN JOINT SEAL AFTER CONCRETE SET CONCRETE SLAB ON GRADE EPOXY COATED ROUND DOWEL BASKET ASSEMBLY WITH j"0 x 14" AT 12" OC CENTERED IN SLAB (GREASE ONE END) TYPICAL CONCRETE SLAB CONTROL JOINT LAYOUT DETAIL NTS 14142-C-100 SHT 2 - ISOLATION JOINT PROVIDE CONT J" FIBER BOARD - TO EXTEND FROM BOTTOM OF CONCRETE TO TOP OF CONCRETE MINUS J" MAY USE WITH/OR WITHOUT REMOVABLE TOP CAP COLD-JOINT CONSTRUCTION JOINT PROVIDE SAW-CUT JOINTS AS SOON AS CONCRETE HAS HARDENED SUFFICIENTLY TO PERMIT CUTTING WITHOUT CHIPPING. SPAUJNG. OR TEARING (BUT NOT MORE THAN 12 HOURS AFTER PLACEMENT) CONCRETE SLAB ON GRADE K SMOOTH ROUND DOWEL BASKET ASSEMBLY (EPOXY COATED) H't x 14" SPACED AT 12" OC) CENTERED IN SLAB (GREASE ONE END) NOTES. SAW-CUT CONSTRUCTION JOINT SEE DRAWING CSD001 AND CSD002 FOR STANDARD GENERAL CONCRETE NOTES COMPACT NATIVE SOIL TO 95% MAXIMUM DRY DENSITY WITHIN PROJECT BATTERY LIMITS IF CLAY IS ENCOUNTERED, OVER EXCAVATE TO 12" AND REPLACE WfTH ENGINEERED FILL ACID TANK CONTAINMENT CHAMBER TO BE SULPHATE RESISTANT TYPE V CONCRETE ALL OTHER CONCRETE TO BE TYPE II ENGINEERED FILL. CLEAN. NON-ORGANIC, GRANULAR, MINERAL SOIL FINES TO BE NON-EXPANSIVE, NON-COLLAPSIBLE MAXIMUM PLASTICITY INDEX = 12% GRANULATION AS FOLLOWS SIEVE % PASSING 1" 100% ±0 85% ±10% 04 55% ±10% 016 31% ±8% 0200 9% ±3% TAIL fT^ _P_EJAIL 3/4' 100 SHT 2 ELEC CHECK DRAWN REFERENCE DRAWINGS HEVBEO com JOMT COM, ADDED sur BOX OCTAL REVISIONS REVISIONS SSUE RECORD INST CHECK MECH CHECK PROJECT MGR ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE DETAILS BLANDING, UTAH SCALE 3/4* = r-o" PROJECT NO 2014142 CAD NO 14142-C-202 14142-C-202 1 10'-0" 2-0" 5' 5" 3'-0" 2-0" 5" 5' -(4) 1*V HOLE FOR %' ANCHOR ROD (TYP) 4-0" 3-0 PLAN A\ DETAIL rr\ 3/4"= 1-0" Vj4142-C-100 4> 1-0" 1-0 2 CLR TYP - 03 HORIZ TIE SETS (8) 06 VERT (BENT) (SPACE AS SHOWN) PLAN OF TYP. PIER i"=r-o" L _ J HEAVY HEX NUT (A563) AND FLAT WASHER (F436) HEAVY HEX JAM NUT (A563) AND FLAT WASHER (F436) TOP OF CONCRETE PIER ASTM F1554 GR36 HEX HEAD BOLT TYPICAL ANCHOR ROD DETAIL y=r-o" 4'-0" ANCHOR ROD, TYP - (SEE DETAIL) \ 5" 03 HORZ W/ (3) IN THE TOP Di' - 6" 0 C THEREAFTER (TYP) (8) 06 VERT, AROUND - EQ SP (TYP) 04 HORZ , 12" OC ~ EACH WAY, TOP 4 BOTTOM -NEW PAVING TO MATCH EXIST PAVING 10-0 EL =5639 50 SEE PLAN ANCHOR ROD, TYP - (SEE DETAIL) 03 HORZ W/ (3) IN THE TOP Di" - 6" 0 C THEREAFTER (TYP ) (8) 06 VERT, AROUND - EO SP (TYP) 5" 5" 04 HORZ, 12" OC - EACH WAY, TOP 4 BOTTOM - NEW PAVING TO MATCH EXIST PAVING 6-0 EL=5639 50 SEE PLAN SECTION 3/4"= 1 SECTION fB 3/4"=1'-0" ELEC CHECK REFERENCE ORAflHCS BSUED AS BH.7 l&ISIIJNS • > n w DUE REVISIONS ISSUE RECORD' INST CHECK PROJECT ENG PROJECT MGR ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE SECTIONS & DETAILS BLANDING, UTAH 3/4"=1'-0" PROJECT NO 2014142 CAD NO 14142-C-210 14142-C-210 r 10'-0" 2-0" 2'-0" 5" 5" 5 5 V t «M8M'-6-- (TYP) -t Vx12M'-0" (TYP) -(4) 1*," HOLE FOR W ANCHOR ROD (TYP) 4" 4" -(2) I5f6" HOLE FOR %" ANCHOR ROD (TYP) 4'-0" ANCHOR ROD, TYP (SEE DETAIL) 1'-0" 1'-0" 03 HORZ W/ (3) IN THE TOP W 6" 0 C THEREAFTER (TYP ) (8) 06 VERT, AROUND EO SP (TYP) CONCRETE PAVING (SEE PLAN FOR EXTENTS) 04 HORZ, 12" OC EACH WAY, TOP * BOTTOM 4-0 EL=5639 50 i SEE PLAN 10-0 2 CLR TYP 03 HORIZ TIE SETS (8) 06 VERT (BENT) A / (SPACE AS SHOWN) PLAN OF TYP. PIER SECTION /B 3/4"= r-o- PLAN DETAIL ANCHOR ROD, TYP (SEE DETAIL) 03 HORZ W/ (3) IN THE TOP Di' 6" 0 C THEREAFTER (TYP (8) 06 VERT , AROUND EO SP (TYP) CONCRTE PAVING (SEE PLAN FOR EXTENTS) 04 HORZ, 12" OC EACH WAY, TOP k BOTTOM 3/4 =1-0 4142-C- 00 4-0 0 EL =5639 50 SEE PLAN 10-0 4-0" -HEAVY HEX NUT (A563) AND FLAT WASHER (F436) -HEAVY HEX JAM NUT (A563) AND FLAT WASHER (F436) TOP OF CONCRETE PIER ASTM F1554 GR36 HEX HEAD BOLT ANCHOR ROD, TYP (SEE DETAIL) 03 HORZ W/ (3) IN THE TOP Di' -\ 6" 0 C THEREAFTER (TYP ) (8) 06 VERT. AROUND EQ SP (TYP) CONCRETE PAVING (SEE PLAN FOR EXTENTS) 04 HORZ, 12" OC - EACH WAY, TOP 4 BOTTOM 4> EL =5639 50 SEE PLAN 10-0 inr TYPICAL ANCHOR ROD DETAIL 3"=1'-0" SECTION 3/4"=1'-0" SECTION 3/4"=1'-0' REFERENCE PRAW1NGS REVISIONS HO Br CKD Aff» OWE REVISIONS DATE r55 REV SSugftECQRD ELEC CHECK STRUCT CHK CHECKED ENG MANAGER ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT CONCRETE DETAILS AND SECTIONS BLANDING, UTAH SCALE 3/4"=1'-0" PROJECT NO 2014142 CAD NO 14142-C-211 14142-C-211 FOUNDATION - (BELOW) - HORIZ L 2% x 2% x K BRACING (TYP) AT TOP CHORD W8x18 L 5x5x?rj DIAG BRACE 1 8-0" 8-0 8-0 8-0 8-0 W8x18 (5597 AXIAL) El E} (5597 LB AXIAL) A > VERTICAL BRIDGING BY JOIST MANUFACTURER SEE /T^ 3 PLC V 14H2-S-110 W8x18 WBx18 L_ SEE ^ VJ4142 PRE-ENGINEERED LONG SPAN STEEL JOIST 32LH (220/70) 14142-5-110 4-0 PLAN - PIPE BRIDGE VJ4142-C-210 t TRUSS ? TRUSS 1/4"= 1-0' FOUNDATION (BELOW) 4142-C-211 <t COL 14142-S-110^ ^ EL =5657 75' (TOP OF SUPPORT) <t COL 'VJ4142-S-110 64-0 C4x5 4 6 8 -0 0 C (TYP) 0 EL =5655 5 (BTM OF JOIST) W8x18 -W8x18 PRE-ENGINEERED LONG SPAN STEEL JOIST (2 PLACES) PROVIDE CAMBER +2 UP AT MID-SPAN 14142-S-110 EXIST ASPHALT (SEE PLAN) 14142-S-110 \J4142 S-110 14142-5-110 CONCRETE PAVING (SEE PLAN FOR EXTENTS) f £\ ) EL =5639 50' (TOC PIER) ^ / EL =5639 50 (TOC PIER) C4x5 4 14142-S-110 W8x18 PL J" x6"x0'-6" (BETWEEN ANGLES) 14142-S-110 / 3/16 3/16 CONC FOOTING 4 PIERS - EXIST CONC VALLEY GUTTER—' (SEE PLAN) CONC FOOTING 4 PIERS TYPICAL END VIEW i/4"= r-o" ELEVATION - PIPE BRIDGE 1/4"= 1-0" (LOOKING NORTH) NOTES' 1 WORK THIS DRAWING WITH DWGS 14142-S-110, 14142-C-210. 14142-C-211, AND 14142-C-100 2 JOIST LOADS SHOWN (TOTAL LOAD/UVE LOAD) 3 LOADS SHOWN ON MEMBERS ARE NON-FACTORED 4 DESIGN LOADS USED DL=150 LB/FT. EACH, SIMULTANEOUS LL=20 LB/FT. EACH, SIMULTANEOUS SL=70 LB /FT , EACH, SIMULTANEOUS WL X,Z = 45 LB /FT , EACH, NOT SIMULTANEOUS EQ Y,Z = 20 LB /FT EACH, SIMULTANEOUS ITOENCE DRAWINGS- rSSUEO AS BUBJ ISSUE RECORD INST CHECK PROJECT ENG ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT PIPE RACK PLAN AND ELEVATION BLANDING, UTAH SCALE l/4'=l'~°' PROJECT NO 2014142 CAD NO 14142-S-100 14142-S-100 4-0" t TRUSS - PRE-ENGINEERED STEEL JOIST - (SEE PLAN FOR SIZE) L_ tTRUSS \ 3/16 CHAN TO TOP CHORD JOST TRUSS TO COL CAP ¥ CHANNEL (SEE PLAN FOR SIZE) - BRIDGING ft PROVIDED BY JOIST MANUFACTURER (SEE PLAN FOR LOCATION) DETAIL 1/2"= 1'-0" \J42-S-100 ELEVATION PRE-ENGINEERED STEEL JOIST (SEE PLAN) %' CLR TRUSS (TOP CHORD) 3/16 / 3/16 -HORIZ DIAGONAL BRACE 3/16 3/16 7 3/16 CHANNEL ON TOP OF TRUSS (SEE PLAN FOR SIZE) \ 3/16 PLAN DETAIL i 1/2"= r-o" VJ42- (ROTATED) S-100 ¥ COL 3/16 1" 3/16 %t A307 M B EA. SIDE OF TRUSS 3/16 f rrp 1 1/4 ;^PRE ENGINEERED STL JOIST (SEE PLAN FOR SIZE) COL CAP PLATE t 3,"x6"x0'-9" (CENTERED) STL COLUMN (SEE PLAN FOR SIZE) VJ42- DETAL 1 1/2 =1-0 S-100 r . 1/4 TYP 1/4 1 Jf x 8J$" x 1'-9 (ON t) STL COLUMN (SEE PLAN FOR SIZE) (2) n t A325 BOLTS VERT DIAGONAL BRACE (SEE PLAN FOR SIZE) DETAIL 1=1-0" 142-S-100 "t )6 x12"xO'-8" 2 n * A325 BOLTS 0" \J42-S- DETAIL 100 \ '/4 TYP 3 SIDES ) — / V4 I K x 2)f x HORIZONTAL ST1FFENER PLATE (TYP T&B BRACE GUSSET £) STL COLUMN^' (SEE PLAN FOR SIZE) 1 1/2"=1 CONCRETE PIER (SEE SHT 14142-C-211 FOR DETAILS) 1/4 V 3 IK IK (2) K* «25 BOLTS "=r-o" \j42-s-100 (2) K* HSB (A325) CHANNEL (SEE PLAN FOR SIZE) STL BEAM (SEE PLAN FOR SIZE) CUP £ CORNERS AS REQ'D TO CLEAR WELDS (TYP) — VERT DIAGONAL BRACE -_L_V 1/4 1/4 (4) 1K6"« HOLE FOR K* ANCHOR ROD t J4M8"x1'-6" DETAIL 1 1/2' DETAIL {TA (4) PLACES r=r-o" VERT DIAGONAL BRACE TRIM OSL AS REQ'D TO CLEAR COL FLG (SEE PLAN FOR SIZE) STL COLUMN (SEE PLAN FOR SIZE) (2) ¥,'* A325 BOLTS t JS" x 6" x 1'-8>f 1/4 TYP V4 ax v J 1/4 tir DETAL 6" 6" (2) 1jf6"» HOLES FOR W* ANCHOR ROD t "O<12"x1'-0" 1/4 FACE OF I DETAIL r=r-o" (2) PLACES <TYP CONCRETE PIER (SEE SHT 14142-C-210 FOR DETAILS) CUP CORNERS AS REQ'D TO CLEAR WELDS 1 1/2"=1'-0" \142-S-1O0 PWC No REFERENCE DRAWINGS Wis REVISIONS SSUE RECORD' MECH CHECK PIPING CHK ENG MANAGER ENGINEERING RECORD ENERGY FUELS AMMONIA CONTAMINATED AREA PLANNED CONCRETE PLACEMENT PIPE RACK DETAILS BLANDING, UTAH SCALE AS NOTED PROJECT NO 2014142 CAO NO 14142-S-110 14142-S-110 Attachment 2 3 A. GENERAL NOTES: C. CONCRETE: o.w>carEMT: r & 5 i I THESE STANDARD NOTES SHALL BE CONSIDERED SUPPLEMENTAL TO THE REQUIREMENTS NOTED ON INDIVIDUAL ENGINEERING DRAWINGS AND/OR PROJECT ENGINEERING SPECIFICATIONS WHERE ISSUED. WHERE CONTRADICTORY REQUIREMENTS OCCUR BETWEEN THESE NOTES AND THE REQUIREMENTS STATED ON THE INDMDUAL ENGINEERING DRAWINGS AND/OR SPEanCATONS, THE DRAWINGS AND/OR SPECIFICATIONS SHAU GOVERN. 2. THESE NOTES SHALL BE READ AND CONSTRUED AS A WHOLE. HEADERS USED M THESE NOTES ARE FOR CONVENIENCE ONLY AND THE NOTES CONTAINED BETWEEN SUCH HEADERS SHALL NOT BE INTERPRETED AS ALL INCLUSIVE OF THE SUBJECT DEFINED BY THE HEADER 3. PROJECT SPECIFICATIONS MAY OR MAY NOT BE ISSUED FOR THE PROJECT WHERE NO SPECIFICATION IS LISTED ON THE ENGINEERING DRAWINGS, THE REFERENCE TO ENGINEERING SPECIFICATIONS W THESE STANDARD GENERAL NOTES SHAU BE IGNORED 4. ALL DESIGN AND CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE LATEST EDITION OF THEAa318,INTEr<jWIOrWBUtiJD^ AND ANY LOCAL BUILDING CODE REQUIREMENTS 5 WHERE THE REQUIREMENTS OF THESE GENERAL NOTES, THOSE LISTED ON THE ENGINEERING DRAWINGS, OR STATED IN THE PROJECT ENGINEERING SPECIFICATIONS, WHERE ISSUED, CONFLICT WITH ANY FEDERAL, STATE OR LOCAL COOES, THE CONTRACTOR SHALL NOTIFY THE OWNER OR HIS AGENT/ENGINEER FOR Cl/RIFEATION. THE CONTRACTOR SHALL RECEIVE WRITTEN CLARIFICATION AND/OR INSTRUCTION PRIOR TO PROCEEDING 6 ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKfNG DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ENGINEER BEFORE PROCEEDING WITH ANY INVOLVED WORK. 7 OBSERVATION VISTTS TO THE JOB SITE BY THE ENGINEER OF RECORDS FTELD REPRESENTATIVE SHAU- NOT BE CONSTRUED AS NSPECTION NOR APPROVAL Of CONSTRUCTION. 8 THE CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS, DESIGNATED ACCESS. DESIGNATED STAGING/LAY DOWN AREAS, AND Aa OTHER CONDITIONS THAT MAY IMPACT THE TIMELY COMPLETION OF WORK CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS AND OBTAIN ANY OTHER ADDITIONAL DIMENSIONS NOT PROVIDED ON THE ENGINEERING DRAWINGS INACCURACIES M OR CONFLICTS BETWEEN THE INFORMATION PROVIDED ON THE ENGINEERING DRAWINGS SHALL BE BROUGHT TO THE OWNERS OR HIS AGENT/ENGINEERS ATTENTION FOR RESOLUTION PRIOR TO PROCEEDING. 9 THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE SAFE OPERATION OF HIS EQUIPMENT WITHIN THE FACILITY BY HIS CREW OR HIS SUBCONTRACTORS. IF DAMAGE OCCURS TO THE OWNER'S FACILITY, OTHER CONTRACTORS EQUIPMENT, CONTRACTORS OWN EQUIPMENT OR INJURY TO PERSONNEL INCLUDING CONTRACTORS, OTHER CONTRACTORS, OWNERS EMPLOYEES OR OTHERS THAT MAY BE ON SITE. AS A RESULT OF CONTRACTORS PERSONNELS ACTIONS, THE CONTRACTOR SHALL BE RESPONSIBLE 10. CONTRACTOR TO PREPARE CC4NSTRUCT10N PLAN. ACCOUNTING FOR CONSTRUCTION INDUCED LOADING. CONTRACTOR TO INSURE THAT STRUCTURES ARE ADEQUATELY SLIPPORTED DURING Aa PHASES OF CONSTRUCTION AND THAT CONSTRUCTION INDUCED LOADS ARE HELD TO REASONABLE LEVELS, AND THAT STRUCTURE IS FULLY ERECTED ANO ATTACHED PRIOR TO PLACEMENT OF SERVICE LOADS II CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (2 COPIES) TO THE ENGINEER OF RECORD PRIOR TO FABRICATION OR ERECTION OF REINFORCING STEEL 12 CONTRACTOR SHALL CONFVRM ALL ELEVATIONS SHOWN ON DRAWINGS TO VERIFY THAT NEW CONSTRUCTION MATCHES EXISTING CONDITIONS 13 SPECIAL INSPECTIONS OF CONCRETE REINFORCING STEEL. ANO ANCHORS SHALL BE IN ACCORDANCE WITH CURRENT BC SPECIAL INSPECTION REQUIREMENTS B.rj6flrcTTIOM8: 14 ENGINEERED FILL SHALL MEAN SOIL HAVING SPECIFIC PROPERTIES OUTUNED IN THE PROJECT SPECIFICATION DEFINING ENGINEERED SOL 15 NATURAL SOIL SHALL MEAN SOIL CURRENTLY AT THE LOCATION WHERE THE CONCRETE IS TO BE PLACED WHETHER NATURAL TO THE AREA OR PLACED THERE AS A RESULT OF PREVIOUS CONSTRUCTION ACTTvTTIES 16 UNDISTURBED SOIL SHALL MEAN SOI THAT HAS BEEN IN-PLACE FOR A MINIMUM OF 15 YEARS. 17. COMPACTED SOIL SHALL MEAN ANY SOIL EITHER UNDtSTURBED OR DISTURBED THAT HAS BEEN COMPACTED TO A SPECIFIED DENSITY AS DEFINED IN THE LATEST EDITION OF ASTM D1557 OR ASTMD698 18 MIX WATER SHALL MEAN POTABLE WATER 19. CONCRETE PROPERTIES, UNLESS OTHERWISE NOTED ON THE ENGINEERING DRAWINGS OR PROJECT SPECIFICATIONS, SHALL BE AS FOLLOWS: I CONCRETE = ASTM C94 b CEMENT TYPE. TYPE II (USETYPEVFOR CONCRETE IN CONTACT WITH CAUSTIC 4 SULFATE RICH SOL) c MAXIMUM WATERCEMENT RATIO. 045 d MINIMUM 28 DAY COMPRESSIVE STRENGTH 4000 PSI • MAXIMUM AGGREGATE SIZE. 1'OR 1/3 OF PUMP PIPE ID FOR F«tf^ CONCRETE I AGGREGATE GRADATION ASTM C33 (15-30% PASSING NO 50 AND 5-10% PASSING NO. 100 SCREENS) g. CONCRETE WEIGHT NORMAL (150 LBS/CU FT) h AJR ENTRAINMENT (CONFORM TO C2S0): 6% ±15% L SLUMP: 3" TO 4* (4" TO 5" AT PLACEMENT FOR PUMPED CONCRETE) 20. MAXIMUM AGGREGATE SIZE SHALL BE X" UNLESS OTHERWISE NOTED ON THE ENGINEERING DRAWING OR PROJECT SPECIFICATION WHERE SUPPLIED 21. THE CONTRACTOR SHALL, AT THEIR EXPENSE, PREPARE A SET OF THREE (3) COMPRESSION TEST CYUNOERS FOR EVERY 150 CUBIC YARDS OR SIX SOUAREr^Cf CONCRETE PLACED WITHIN A SINGLE DAY ATA MINIMUM THE CONTRACTOR SHALL PREPARE A SET OF THREE (3) COMPRESSION TEST CYLINDERS EACH DAY THAT CONCRETE IS PLACED WITHOUT REGARD TO THE AMOUNT OF CONCRETE PLACED THE COMPRESSION TEST CYLINDERS SHALL BE PROPERLY MARKED AT THE TTME THE CYUNDERS ARE PREPARED. AND DELIVERED TO THE TEST LABORATORY DESIGNATED BY THE OWNER OR OWNER AGENT WITHIN TWENTY-FOUR (24) HOURS AFTER THEY ARE FLLED. CONTRACTOR MAY SUBMrT TO THE OWNER OR OWNER AGENT FOR CONSIDERATION AN ALTERNATIVE TESTING LABORATORY THAT MAY BE MORE CONVENIENT TO THE JOB SrTE 22. COMPRESSIVE STRENGTH TESTS SHAU CONFORM TO ASTM C39 AND TEST RESULTS SHALL BE SUBMITTED IN WRITING DIRECTLY TO THE OWNER OR OWNERS AGENT/ENGINEER WITHIN ONE WEEK OF TEST COMPLETION. CONTRACTOR SHAU ALSO RECEIVE A COPY OF THE RESULT FROM THE LABORATORY FOR THBR RECORDS. 23 CONCRETE FOUND TO HAVE INADEQUATE STRENGTH SHAU BE REMOVED AND REPLACED AT CONTRACTORS EXPENSE O. REINFORCEMENT STEEL 24. REINFORCEMENT STEEL SHAU BE NEW, UNDAMAGED. FREE FROM CORROSION, FOREIGN DEBRIS, OL AND GREASE AND SHAU BE DEFORMED BILLET-STEEL BARS PER ASTM A 615, GRADE 60 HAVING AYELD STRESS OF 60.000 PSI. 25. DETALMG AND FABRICATION OF BENT REINFORCEMENT SHAPES SHAU BE PER THE LATEST EDITION OF ACI 318 AND ACI 315. 26. REINFORCEMENT STEEL AND ANY ASSOCIATED EMBEDDED MATERIAL SHAU BE PLACED ACCURATELY AND HELD IN PLACE BY SECURELY TYING OR ADEQUATELY SUPPORTING BEFORE CONCRETE IS PLACED TO ENSURE DISPLACEMENT OF REINFORCEMENT OR ASSOCIATED MATERIAL IS LIMITED AND MEETS THE TOLERANCE STATED M ACI 318 (LATEST EDmON). 27 REINFORCEMENT COVER FOR CONCRETE CAST DIRECTLY AGAINST EARTH SURFACES SHAU BE 3 INCHES MINIMUM UNLESS NOTED OTHERWISE ON THE ENGINEERING DRAWMGS OR ENGINEERING SPECIFICATIONS CONCRETE CAST AGAINST FORMS SHALL HAVE A MINIMUM OF 21/2 INCHES OF COVER UNLESS NOTED OTHERWISE ON THE ENGINEERING DRAWINGS 28. REINFORCEMENT THAT IS PARTIALLY EMBEDDED IN CONCRETE SHAU NOT HAVE THE PART1AUY EXPOSED PORTION OF THE BAR FELD BENT WITHOUT WRITTEN AUTHORIZATION OF THE OWNER OR OWNERS AGENT/ENGINEER 29 UNLESS NOTED OTHERWISE ON THE ENGWEERWG DRAWINGS, LAP SPLICES FOR UNCOATED DEFORMED BAR SHAU BE PER THE FOLLOWING TABLE BAR SIZE LAP SPLICES 4 24 INCHES 5 30 INCHES 6 3S INCHES 7 42 INCHES 8 47 INCHES 9+ PER DRAWING WHERE THESE SPUCE PJKX/IREMENTS CANNOT BE MET, APPROVED ALTERNATIVE SPLICING METHODS SHAU BE EMPLOYED WITH ENGINEERS APPROVAL 30. REINFORCEMENT SHAU NOT BE WELDED WITHOUT PRIOR APPROVAL AND INSTRUCTIONS FROM ENGINEER 31. EM8EDED ITEMS SHAU BE FABRICATED FROM NEW MATERIAL, AND SHAU BE FREE FROM CORROSION, FOREIGN DEBRIS AND OIL OR OTHER LUBRICATIONS 32 EMBEDDED DOWELS OR RODS SHAU BE LOCATED PER THE ENGINEERING DRAWINGS AND HELD WITHIN THE FOUOWtNG TOLERANCES: ELEVATION POSITION ANGULAR VERTICAL 1>4INCH iJflNCH tV HORIZONTAL 0 INCHES < STRAIGHT LENGTHS 60 INCHES' ±1" 60 INCHES < STRAIGHT LENGTH S120 INCHES H/2" 120 INCHES < STRAIGHT LENGTH S 240 INCHES: HM* 33 IF EMBEDMENT INTERFERES WITH REINFORCEMENT STEEL THE CONTRACTOR SHAU NOTIFY OWNER OR OWNERS AGENT/ENGINEER FOR WRITTEN INSTRUCTION ON INTERFERENCE RESOLUTION F. ANCHORS: 34 UNLESS OTHERWISE INDICATED ON ENGINEERING DRAWINGS, ANCHORS SHAU BE CAST tN PLACE 35 ANCHOR RODS SHAU BE CONSTRUCTED FROM NEW ASTM F1554 GRADE 36 MATERIAL UNLESS INDICATED OTHERWISE ON THE ENGINEERING DRAWINGS OR IN THE ENGINEERING SPECIFICATION, AND SHAU BE FREE FROM CORROSION, LOOSE MU SCALE FOREIGN DEBRIS ANO OILS, GREASE OR OTHER LUBRICATIONS EXCEPT AS NOTED BELOW 36. UNLESS NOTED OTHERWISE ON THE ENGINEERING DRAWINGS OR ENGINEERING SPECIFICATION, AU ANCHOR ROD THREADS SHAU BE NATIONAL COARSE WITH A CLASS 1 FIT AU ANCHOR RODS SHAU BE SUPPLIED WITH A MINIMUM OF TWO MATCHING HEAVY HEX NUTS (ASTM A563) AND ONE FLAT WASHER (ASTM F438) EXCEPT WHERE ADDITIONAL NUTS OR OVERSIZED WASHERS ARE NOTED ON THE ENGINEERING DRAWINGS 37 ANCHORS SHAU BE LOCATED PER THE ENGINEERING DRAWINGS ANCHOR ROD TOLERANCE SHAU BE PER THE FOUOWtNG UNLESS OTHERWISE MOTH) ON THE ENGINEERING DRAWINGS OR ENGINEERING SPECIFICATION SLEEVED ANCHORS PROJECTION: POSITION: ANGULAR. 11/8 INCH 13/16 INCH S3 INCHES > 3 INCHES' ± 1" (IN FINAL LOCATION) i V (IN FINAL LOCATION) NON-SLEEVED ANCHORS PROJECTION 11/8 INCH POSITION ±1/8 INCH ANGULAR S3 INCHES tV >3tNCHES iV 38 BENDING (EITHER PERFORMED HOT OR COLD) SHAU NOT BE USED TO CORRECT ANCHOR LOCATIONS NOT CONFORMING TO THE ABOVE TOLERANCE WITHOUT WRITTEN CONSENT OF ENGINEER OF RECORD 39 DURING INSTALLATION OF CAST IN PLACE ANCHOR RODS, THREADS NOT ENCASED IN CONCRETE SHAU BE PROTECTED BY COATING WITH GREASE AND ENCASING THEM IN BURLAP OR PAPER 40 WHETC ADHESIVE ANCHCIRS ARE SPECIFIED C«NEN^ ENGINEERING SPECIFICATIONS, THE ANCHORS AND ADr€S(VE SHAU BE AS SPECIFIED INSTALLATION SHAU BE PER MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS 41 CONTRACTOR SHALL NOTIFY OWNER OR OWNERS AGENT/ENGINEER A MINIMUM OF 48 HOURS IN ADVANCE OF SCHEDULED CONCRETE PLACEMENT TO AUOW ON SITE OBSERVATION OF FORMS. REINFORCEMENT STEEL EMBEDMENT, ETC. 42 fJRORTOFLACEIJeJJOFCONCKFJE.CO^ ENSURE AU OPENINGS. SLEEVES. CURBS, CONDUITS, INSERTS, ANCHOR RODS. ETC., WHETHER SHOWN ON THE ENGINEERING DRAWINGS OR OMITTED. HAVE BEEN IDENTIFIED AND PROPERLY PLACED. 43 PRIOR TO PLACEMENT OF CONCRETE. THE CONTRACTOR SHAU INSPECT AU OPENINGS OF PIPES, CONDUITS, ETC PLACED BY OTHER TRADES TO MAKE CERTAIN THE INTEGRITY OF THE COVER IS SOUND AND ABLE TO WITHSTAND ACCIDENTAL DAMAGE OR IMPACT DURING CONCRETE PLACEMENT. THE CONTRACTOR IS RESPONSIBLE TO ENSURE FUU AND COMPLETE EMBEDMENT AT OPENINGS SUCH THAT NO OBSTT<UCTION OCCURS DURING OR AFTER THE PLACEMENT OF CONCRETE. THE COVERING SHAU REMAIN IN PLACE AND SHAU BE REMOVED BY THE TRADE RESPONSIBLE FOR THE EMBEDMENT. 44. CONTRACTOR SHAU AVOID PLACING CONCRETE DURING INCLEMENT WEATHER IF SUCH IS FORECASTED WITHIN 36 HOURS OF PLACEMENT. CONTRACTOR SHAU TAKE PROPER STEPS TO ENSURE CONCRETE DOES NOT SUFFER EITHER STRUCTURAL OR COSMETIC DAMAGE. 45. CONCRETE SHAU NOT BE PLACED WHEN TEMPERATURES ARE BELOW 50" F OR ANTICIPATED TO DROP BELOW 50*F WITHIN THE FERST 48 HOURS AFTER PLACEMENT WITHOUT PROPER PROTECTION TO ENSURE CONCRETE CURES PROPERLY ADDITIVES TO SHORTEN TIME/STRENGTH RATIO, OR REDUCE FREEZING SHAU BE APPROVED BY THE ENGINEER OF RECORD PRIOR TO PLACEMENT OF CONCRETE. 46. CONCRETE SHAU BE FINISHED LEVEL WITHIN THE FOUOWING TOLERANCE UNLESS NOTED OTHERWISE ON THE ENGINEERING DRAWINGS LOW SPOTS SHAU BE MINIMIZED AND MUST UMIT PONDING WATER TO NO MORE THAN 1/16 INCH DEEP. ELEVATION ±1/8 INCH POSITION ±1/8 INCH 11/8 INCH IN 120 INCHES IN ANY DRECT10N 47 ETjGESOFAUEXPCtSFjDCOrVO^Sl^^ INCH CHAMFER EDGE. 48 AU HORIZONTAL FLAT SURFACES OF CONCRETE INCLUDING TOPS OF WALLS, PIERS. ANO SLABS SHAU HAVE A ROUGH BROOM FINISH TO PREVENT SUPS AND FALLS WHEN SURFACE tS WET. 49 FORMS SHAU REMAIN IN PLACE FOR A MINIMUM OF 24 HOURS UNLESS SPECIFIED OTHERWISE IN THE ENGINEERING SPECIFICATIONS 50. CUT JOINTS IN SLABS, WHERE SPECIFIED ON PLAN, SHAU BE CUT AS SCON AS THE CONCRETE HAS HARDENED SUFFICIENTLY TO PERMIT CUTTING WITHOUT CHIPPING, SPAUING OR TEARING BUT NOT MORE THAN 12 HOURS AFTER CASTING 51 UMITATIONS FOR HOT-WEATHER CONCRETING SHAU CONFORM TO ACI 3051 OR 30SR 52. REPAIR OF CONCRETE SURFACE DEFECTS SHAU CONFORM TO ACI 301 ISSUED FOR CONSTRUCTION PWC No KffllENcE MAwbVg" lltVstONS •as issue mm EUC CHECK MECH CHECK PIPING CHK DRAWN PROJECT MGRl ENG WANACCRT PESO IWR EWGMEBIIHG RECORD STANDARD CONCRETE GENERAL NOTES NONE PROJECT NO CAD NO CSD001 CSD001 A -4 3-4 1% GRADE 17-4 29-4" 35' ® ® ® EXISTING CONCRETE FOOTINGS FOR TANK SUPPORT STRUCTRURE EXISTING CONCRETE PAD UNDER AMMONIUM SULFATE STORAGE TANKS ® ® 27' PLAN NOTES: SEAL 2" TYP #4 REBAR 24" OC NEW CONCRETE CAP 6" SECTION - A 2 TYP NEW CONCRETE CAP , #4 REBAR 24" OC i 6" ® ® SECTION - B 10' A 1. THIS DRAWING IS FOR SURFACE REPAIR OF DETERIORATED CONCRETE UNDER THE AMMONIUM SULFATE STORAGE AREA. 2. EXISTING CONCRETE SHALL BE CLEANED TO REMOVE LOOSE DEBRIS AND AMMONIUM SULFATE PRIOR TO NEW CONCRETE PLACEMENT. SITE ENGINEERING APPROVAL REQUIRED PRIOR TO NEW CONCRETE PLACEMENT. 3. SURROUNDING AREA DETAILS: A. NORTH - PULP STORAGE IMPOUND B. EAST - TRUCK UNLOADING AREA - NEW CONCRETE SURFACE WITH SUMP C. SOUTH & WEST - MILL BUILDING 4. REBAR MAT SHALL BE CONNECTED TO THE EXISTING CONCRETE BY DOWELING INTO THE EXISTING CONCRETE AND SECURING WITH EPOXY. LOCATIONS ARE DESIGNATED BY (®). MINIMUM DEPTH 5". 5. NEW CONCRETE SHALL BE PLACED AS A 6" CAP ON THE EXISTING CONCRETE. ACTUAL THICKNESS MAY VARY DUE TO THE DETERIORATION AND GRADE OF THE EXISTING CONCRETE. MINIMUM THICKNESS SHALL BE NO LESS THAN 5". 6. STANDARD CONCRETE NOTES APPLY. REFERENCE PSE DRAWING CSD001. SLUMP AND COMPRESSIVE CYLINDER TESTING IS NOT REQUIRED. 7. WATERSTOP SHALL BE GREENSTREAK SWELLSTOP OR EQUIVALENT. £j@JpEnergy Fuels Resources (USA) Inc. REVISIONS By pAMMONIUM SULFATE CONCRETE REPAIR County: State: Location: AMMONIUM SULFATE STORAGE AREA CONCRETE REPAIR DETAILS Drafted By: