HomeMy WebLinkAboutDRC-2009-006037 - 0901a0688036199dbtlL-.^A^l CDAC-il
From: Steve Landau <SLandau@denisonmines.com>
To: "DFINERFROCK@utah.gov" <DFINERFROCK@utah.gov>
CC: Harold Roberts <HRoberts@denisonmines.com>. David Frydenlund <DFrydenlun...
Date: 10/19/2009 11:22 AM
Subject: White Mesa Mill Proposed Reagent Building
Attachments: ScanOOl 6871.PDF
Dear Mr. Finerfrock.
Please find attached the containment design for the reagent building which Mr. Harold Roberts discussed with you during his recent
visit to your offices. If you should have any questions regarding this design, please coniaci Mr. Roberts or me.
Yours Truly,
Steven D. Landau
Manager, Environmental Affairs
Steve Landau
Manager, Environmental Affairs
t; (303) 389-4132 ( f: (303) 389-4125
1050 17th Street, Suite 950. Denver. CO 80265
DENISON MINES (USA) CORP
www.denlsonmlnes.com<http://www.denlsonmlnes.com/>
This e-mail is intended for exclusive use the person(s) mentioned as the recipient(s). This message and any attached files with it
are confidential and may contain privileged or proprietary information. If you are not the intended recipient(s) please delete this
message and notify the sender. You may nol use, distribute print or copy this message if you are not the intended recipient(s).
Denlaon Mines (USA) Corp.
1050 17lh Street, Su{te 960
ji».m».tM^^i^m.m— m^ a^ n^n•^w, co 80265
DENISON ^BkM
fVl I N E S "l*^'' ^^ 62B-7798
FM : 303 389-4125
wii*w.(l*nlGDnnilnu.com
October 19, 2009
Sent Via Electronic fPPF) and Recular Mail
Mr. Dane L. Finerfrock
Executive Secretary
Utah Radiation Control Board
Siute of Ulah Departraem of Environmental Qualily
168 Nonh 1950 West
Sail Liifcc City, UT S41 i4-4S50
Re: White Mesa Mill-Reflgem Building Containment Design
Ground Water Discharge Permit (GWDP) UGW370004
Dear Mc, Finerfrock:
In accordance wilh your recent discussion wilh Mr. Harold Roberts of DUSA, please find enclosed
the contairunenl design and localion for the proposed construction of a reagent building al the White
Mesa Mill. Iu accordance with Part I.D.3.g) of ihe GWDP (i.e. Mill Site Chemical Reagent
Storage), the containment has been designed to "prevent any contact of tlie spilled or otherwise
released reagent or product with the ground surface". As has been previously mentioned, il is
Denison's intention to construct ti\is facility early this winter and, as such, we would request that
this design review be completed as cxpcdiliou.sly as possible.
If you should have any quesiions about the design, please eonlact Mr. Roberts or mc.
Yours very truly.
^^A>-:;tA^^
(S-^DENISON MINES (USA) CORP.
Slaver D. Landau
Manager, Environmental Affairs
IF
"1 •
o u** f
b te 3 tl -n f C £ +-VI a SI W •• 0, t U L Ll I- 0.0 M S c o c c
"ofo.
1^ g "
. W . . .k. .1.
J ™ L D ^ fin V