Loading...
HomeMy WebLinkAboutDRC-2018-004161 - 0901a0688080606eIxsppcrtox Rmonr lnspection Module: RADMOD-AFIL: Alternate Feed and Insitu Leach Inspection Location: Energy Fuels Resources Inc. (EFRI) - White Mesa Uranium Mill, Blanding Utah. lnspection ltems: Alternate Feed Material storage and processing, l le(2) disposal, and Equivalent Feed and Yellowcake Slurry storage and processing; ALARA Audit Inspection Dates: April 16,2018 through April 18,2018 Inspectors: Ryan Johnson, Utah Division Waste Management and Radiation Control (DWMRC) Tim Butler, DWMRC Personnel Contacted: David Turk, Energy Fuels Resources, Radiation Safety Officer (RSO) Terry Slade, Energy Fuels Resources, ChemisVAssistant RSO Justin Perkins, Energy Fuels Resources, Radiation Safety Technician (RST) Kathy Weinel, Energy Fuels Resources, Quality Assurance Manager Julia Yeckes, Energy Fuels Resources, Staff Attorney Peter Luthiger, Enerry Fuels Resources, Mestefla ISL facility Governing Documents:o UAC R3l3-15o Radioactive Materials License (RML) UTI900479. Applicable Mill procedures and manuals Openins Meetins Energy Fuels Resources: David Turk, RSO Utah DWMRC: Ryan Johnson (Health Physics Inspector) Tim Butler (Health Physics Inspector) During the opening meeting, the inspector discussed the inspection items and documentation to be reviewed during the inspection. The main portion of the Mill was not in operation during this inspection except for the grizzly and pulp storage which is being used for the Sequoyah Fuels alternate feed. The Mill staff reminded the inspectors of the safety requirements for the Mill. Inspection Summarv the inspection consisted of an RSO interview, reviewing applicable documentation and a mill tour. The following discussion provides more detail of the specific items reviewed. I ofPage 4 \\Cbwft2\shw\Shared\RAD\COMMON\Uranium mills\UT1900479 EnergyFuels Res - White Mesa UMillWP Inspection modules\2018\lnspection Reports\lnspection Report RADMOD-AFIL 04'18-l8.docx DRC Meters Used Model SerialNumber Calibration Due Date Dose Rate Ludlum 19 101673 711212018 Item 1. Documentation Review: The Inspector reviewed applicable documentation. Obseryations: The DWMRC inspector reviewed the following documents:. I le.(2) Shipment paperwork;o Alternate Feed receipts;. Equivalent Feed paperwork; ando Tailing Capacity Form. The I I e.(2) shipment paperwork documented:o Where and how the I le.(2) material was disposed of in Tailing Cell #3;o Where the I le.(2) material came from and how much material has been sent to the White Mesa Uranium mill for disposal; ando The radiological surveys of the truck and I le.(2) materialthat was received by the mill. The alternate feed receipts documented:o Which alternate feed material is currently being accepted and stored on the Mill's ore pad; ando How much alternate feed material is currently onsite. The equivalent feed paperwork documented how much equivalent feed material has been accepted and processed at the mill. The Tailing Capacity Form documents that there is space in the tailing cells for the amount of feed material (both alternate feed and conventional ore) that is currently stored on the ore pad. Deficiencies: None Item 2. Mill Tour: The Inspector walked through the restricted area on a general site tour. The tour included the ore pad, the mill, and the alternate feed circuit. Currently KOH alternate feed material is being processed at the alternate feed circuit, Sequoyah Fuels alternate feed is being placed into the grizzly and being stored in the pulp tanks. Observations: The DWMRC inspector also observed:r Alternate feed being stored on the ore pad;o Two Sequoyah Fuels alternate feed shipments being accepted, unloaded and staged next to theMill's grizzly in bags. Due to high winds and a clogged pipe inside the Mill on Monday and Tuesday the Sequoyah Fuels material was not put into Grizzly during the inspection;o Proper PPE was being worn by Mill employees within all observed areas of the Mill;o Proper Radiological Posting were being used within all observed areas of the Mill:o Proper Radiological Monitoring was being done at the Alternate Feed Circuit; andr OSL badges were appropriately being used by all observed employees at the Mill; 2 ofPage 4 \\Cbwfo2\shw\Shared\.RAD\COMMOl.l\Uranium mills\UT1900479 EnergyFuels Res - White Mesa UMill\Hp Inspection modulesp0lg\lnspectionReports\lnspection Reporr RADMOD-AFIL 04- l 8- I 8.docx Radio read observed durins Mill tour Location Dose Rate (uR/hr) Product Storage Yard 450 Alternate Feed Pad 250 Sequoyah Fuels Bags 2,1 00 Solvent Extraction 180 Alternate Feed Circuit 50 Deficiencies: None Item 3. ALARA Audit: During this inspection EFRI was performing an intemal ALARA Audit. The inspectors observed part of that audit. Observations: During the inspection the Inspectors observed:o That the ALARA Audit was being conducted by three qualified EFRI Personnel o Kathy Weinel, Quality Assurance Manager; o Julia Yeckes, Staff Attorney; and o Peter Luthiger, from the EFRI Mestefla ISL facility; o A checklist was prepared prior to the ALARA Audit to aid in the Audit process. The list is made up ofi o ALARA Audit requirements found in NRC Reg. Guide 8.31; o Follow-up items from the previous year; o Recommendations from the DWMRC; and o MSHA requirements; and r The Audit was an examination of records and onsite observations. The records that were being reviewed by the Audit team at the time of the inspection included (but not limited to): o Training Records; o Standard Operating Procedures; and o Radiation Work Permits. A member of the Audit Team also observed the receiving and unloading of trvo Sequoyah Fuels alternate feed shipments. Deficiencies: None Closeout Meetins Energy Fuels: David Turk (RSO) Kathy Weinel, Energy Fuels Resources, Quality Assurance Manager Julia Yeckes, Energy Fuels Resources, Staff Attorney Peter Luthiger, Enerry Fuels Resources, Mestefra ISL facility Utah DWMRC: Ryan Johnson (Health Physics lnspector) Tim Butler (Health Physics Inspector) Findinss None Recommendations None 3 ofPage 4 \\Cbwfp2\shw\Shared\RAD\COMMON\Uranium mills\UT1900479 EnergyFuels Res - White Mesa UMillV{P lnspection modulesu0l8\lnspection Reports\lnspection Report RADMOD-AFIL 04-l 8-l 8.docx r-l Recommendation for Next AFIL Insnectionl. Confirm procedures are being followed if Alternate Feeds are stored offthe ore pad;2. Veriff appropriate postings and radio itoring for processing alternate feeds; Prepared By: Ryan Johnson (Print Name) Reviewed By: Phil Goble (Print Name) ? z r-4uzr (Signature) \cbwb2\shwLShared\RAD\COMMOMUranium m,u**,ro*rx 3"{rl,?tirx.o - *,,. roa UMiil\Frp rnspection modutes\20l8\tnspectionReports\lnspection Reporr RADMOD-AFIL 04-l g-l g.docx