HomeMy WebLinkAboutDWQ-2023-200069APPENDIX I.U - Storm Water Discharges Associated with Industrial Activity from Food and Kindred Products Facilities
Coverage of This Section.
Discharges Covered Under This Section. The requirements listed under this Part shall apply to storm water discharges from the following activities:
Table I.U.1 – Sector U: Food and Kindred Products Facilities
SIC Code
Activity Represented
2011 – 2015
Grain Mill Products
2021 – 2026
Fats and Oils Products
2032 – 2038
Meat Products
2041 – 2048
Dairy Products
2051 – 2053
Canned, Frozen, and Preserved Fruits, Vegetables, and Food Specialties
2061 – 2068
Bakery Products
2074 – 2079
Sugar and Confectionery Products
2082 – 2087
Beverages
2091 – 2099
Miscellaneous Food Preparations and Kindred Products
2111 – 2141
Tobacco Products
Sector Specific Limitations on Coverage. There are no additional limitations on coverage other than those listed in Part I.C.
Sector Specific Prohibition of Non-Stormwater Discharges. In addition to those non-storm water discharges prohibited under Part I.D, this permit does not authorize the discharge of:
Boiler blowdown;
Cooling tower overflow and blowdown;
Ammonia refrigeration purging; and
Vehicle washing and clean-out operations.
Sector Specific Control Measures and Effluent Limits.
In addition to the control measures and effluent limits in Part III, the permittee shall implement the following to minimize pollutant discharges, as applicable:
Employee Training. Employee training shall include the following areas, at a minimum, as topics for applicable personnel:
Procedures for pest control.
Sector Specific Inspection Requirements.
In addition to the inspection requirements in Part IV.A, the permittee shall also inspect the following areas, if they are located at the facility:
Loading and unloading areas for all significant materials;
Storage areas, including associated containment areas;
Waste management units;
Vents and stacks emanating from industrial activities;
Spoiled product and broken product container holding areas;
Animal holding pens;
Staging areas; and
Air pollution control equipment.
Sector Specific Plan Requirements.
Site Map. In addition to the requirements in Part VII.D.3, the site map shall also include the locationof the following, if applicable:
Vents and stacks from cooking, drying, and similar operations;
Dry product vacuum transfer lines;
Animal holding pens;
Spoiled product; and
Broken product container storage areas.
Summary of Potential Pollutant Sources. In addition to the requirements in Part VII.D.4, the Plan summary of potential pollutant sources inventory shall also include the following, as
applicable:
Application and storage of pest control chemicals (i.e. rodenticides, insecticides, fungicides) used on plant grounds.
Monitoring Requirements.
Analytical Benchmark Monitoring. The following analytical benchmark monitoring parameters shall apply specifically to sector U facilities. Parameters found in this Part apply to both
primary industrial activities and any co-located industrial activities. The facility may be subject to the requirements of more than one of the following:
Table I.U.2 – Analytical Benchmark Monitoring Parameters for Grain Mill Products (SIC 2041 – 2048)
Parameter
Benchmark Monitoring Concentration
Total Suspended Solids 1
100 mg/L
Sampling for total suspended solids is not required for stormwater discharges that are infiltrating to groundwater.
Table I.U.3 – Analytical Benchmark Monitoring Parameters for Fats and Oils Products (SIC 2074 – 2079)
Parameter
Benchmark Monitoring Concentration
Biochemical Oxygen Demand
30 mg/L
Chemical Oxygen Demand
120 mg/L
Nitrate plus Nitrite Nitrogen
0.68 mg/L
Total Suspended Solids 1
100 mg/L
Sampling for total suspended solids is not required for stormwater discharges that are infiltrating to groundwater.
Numeric Effluent Limitation Monitoring. There are no numeric effluent limitation parameters for Sector U facilities in this permit.Any additional monitoring and reporting requirements
shall be based on the nature of activities at the facility and the facility stormwater discharges, in accordance with Part V.D.2.