Loading...
HomeMy WebLinkAboutDERR-2024-006393Table of Contents 1.Internal Memorandum 2.RBCA Tier 1 Worksheet 3.Overview Maps 4.Site Map 5.Line Tightness Test 6.Topographic Map Closure Packet for No Further Action Facility ID 4001122 Release ID OJV located at 17800 Riverton Road, Riverton, Utah Facility Information Facility Name:UTAH NATIONAL GUARD, CAMP WILLIAMS Release ID:OJV Facility Address:17800 RIVERTON RD RIVERTON, UT 84065 Facility ID:4001122 Notification Date:01/25/2024 Owner Name:UTAH STATE FUEL NETWORK Reporting Party:April Abate Owner Address:4315 S 2700 W SALT LAKE CITY, UT 84129 Project Manager:Alex Thompson Site Assessment Information a. Contaminant Source Information Cause of Release (if known) Product Released Amount Released (gal) Size (gal) # of USTs Tank Piping Disp Over/Spill Other Comments Gasoline Diesel Waste Oil Unknown Other Tank Piping Disp Free Prod Cont Soil Sources Removed:No No No No No b. Land Use Information Current Land use at the Site:Industrial Surrounding Neighborhood:Industrial (Note: Surrounding land use is Residential if one or more residences share a common property line with the Facility) c. Soil Information Soil Type(s) Depth to Contaminated Soil (feet below land surface): Unkn Method of Soil Type Identification: d. Groundwater Information Was groundwater encountered?:No Thickness of Free Product:None Depth to groundwater (feet below land surface): Is groundwater impacted at any concentration: No Groundwater flow direction: Inferred Slope direction of surface topography:N e. Distance from Highest Measured Contaminated Concentrations and Sampling Location to Nearest Potential Receptor Receptors:(Enter distance to each receptor from corresponding sampling location in feet) Distance- Location Distance- Location Water Line: - Sewer Line: - Building Desc: Electrical: - Natural Gas: - Other Desc: Building: - Telephone: - Property Line - Storm Drain: - Other(specify): - Receptors Within 500 feet: Municipal Well:>500'Domestic Well:>500'Irrigation Well:>500' Other: Surface Water(specify type: lake, stream, creek, river, wetland):Dist: >500' Desc: Jordan River Utah's RBCA Tier 1 Worksheet Printed on: 3/5/2024 2:38:44 PM Facility History - Executive Summary RBCA Tier 1 Screening Level Evaluation Groundwater(mg/L)Soil(mg/Kg) Constituent ISL/Tier 1 Level Highest Concentration and Sampling Location ISL/Tier 1 Level Highest Concentration and Sampling Location Benzene 0.005/0.30 0.20/0.90 Toluene 1.0/3.00 9.0/25.0 Ethylbenzene 0.7/4.00 5.0/23.0 Xylenes 10.0/10.0 142.0/142.0 Napthalene 0.70/0.70 51.0/51.0 MTBE 0.20/0.20 0.30/0.30 TPH-gasoline 1.0/10.0 150/1500 TPH-diesel 1.0/10.0 500/5000 Oil and Grease/TRPH 10.0/10.0 1000/10000 Recommended Tier 1 Actions All contaminant concentration levels are below ISLs or below Tier 1 screening levels and no receptors are within the critical distances. Recommendation - No further action. Tier 1 criteria (contaminant concentration and/or distance to receptors) are exceeded at the site. Recommendation - See attached supplemental information worksheet. Evaluation Completed by:Date: DERR Project Manager's Signature Utah's RBCA Tier 1 Worksheet Printed on: 3/5/2024 2:38:44 PM 3/5/2024 Poin t of th e M ou n tain Overview 5 mi N ➤➤ N Image © 2024 A ir bus Image © 2024 A irbus Image © 2024 A irbus Camp W i lliams State M il itary Reservation Overview 3000 ft N ➤➤ N Camp W i lliam's F uel Dep ot Legend 400 ft N ➤➤ N APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 TEI 5000 NON VOLUMETRIC, TEI 4000 VOLUMETRIC, TEI ULLAGE, TEI LT3 PRECISION TANK & LINE TEST RESULTS SUMMARY INVOICE ADDRESS:TANK LOCATION: WORK ORDER # TECH # 94027 TECHNICIAN: SM STATE TECH # STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141 CAMP WILLIAMS #4001122 REDWOOD ROAD RIVERTON, UTAH 24005 UT 0121 DATE: 2-12-2024 TIME START:TIME END:GROUNDWATER DEPTH: N/A TANK # 1 2 3 4 5 6 7 8 TANK CAPACITY 10000 10000 10000 10000 10000 10000 10000 10000 PRODUCT R/UL DSL DSL DSL DSL DSL DSL DSL TANK N/T N/T N/T N/T N/T N/T N/T N/T VENT N/T N/T N/T N/T N/T N/T N/T N/T PRODUCT LINE PASS PASS PASS N/T N/T N/T N/T N/T LINE LEAK DETECTOR N/T N/T N/T N/A N/A N/A N/A N/A WATER IN TANK PUMP TYPE PRESS PRESS PRESS N/A SCT SCT SCT SCT TANK MATERIAL AST AST AST AST AST AST AST AST PRODUCT LINES TESTED AT50 PSI FOR 15 MIN LINE RATES (GPH) 1. 2. 3. 6. 7. R/UL -.010 DSL -.014 ADDITIONAL INFORMATION:DIESEL TANKS 2 AND 3 PRODUCT LINES ARE MANIFOLDED ABOVEGROUND. ABOVEGROUND TANKS WITH UNDERGROUND PRODUCT LINES TO DISPENSERS ONLY TANKS 1,2 AND 3 HAVE UNDERGROUND PRODUCT LINES CERTIFIED TECHNICIAN SIGNATURE:DATE:2-12-2024 These systems meet all requirements set forth by USEPA 40 CFR and has received third party certification. 5. TEST METHODS USED FOR THIS LOCATION TEI 5000 NON VOLUMETRIC TANK TEST TEI 4000 VOLUMETRIC TANK TEST TEI TANK ULLAGE TEST TEI LT3 LINE TEST X LINE LEAK DETECTOR TYPE & SIMULATED LEAK RATE 1. 2. 3. M = MECHANICAL E = ELECTRONIC # = (GPH) RATE 5. 6. 7. All tests were performed according to manufacturer protocol, and within the common practices of the industry. However due to the variables of tightness testing, these results cannot be guaranteed. There are no warranties expressed, written or implied. 4.8.4. 8. Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.02.13 10:16:19 -07'00' Reason: I am the author of this document ElUSGS •oi•n�frx•chlJ!/P/l{/-111 U.S. DEPARTMENT OF THE INTERIOR U.S. GEOLOGICAL SURVEY JORDAN NARROWS QUADRANGLE : Location of Site