HomeMy WebLinkAboutDAQ-2024-004345Submitted via EPA CEDRI
January 22, 2024
Director, US EPA Region 8
US EPA Region 8
Enforcement and Compliance Assurance Division
1595 Wynkoop Street, Mail Code 8ENF
Denver, CO 80202-1129
Re: Kinder Morgan Altamont LLC
Altamont Main Gas Processing Plant (Title V Permit #1300006003)
40 CFR 60 subpart OOOOa Semiannual LDAR Report
July 1, 2023 through December 31, 2023
Kinder Morgan Altamont LLC (Kinder Morgan) is submitting the enclosed Semi-annual Monitoring
Report as required by 40 CFR 60 Subpart OOOOa. The monitoring report covers the semi-annual period
from July 1, 2023 through December 31, 2023.
If you have any questions or concerns please contact me by phone at (303) 914-7605, or at
erin_dunman@kindermorgan.com.
Sincerely,
Erin Dunman
Environmental Engineer
Attachments:
Attachment 1: NSPS OOOOa Semiannual LDAR Report
Attachment 2: CEDRI report template
Attachment 3: Delay of Repair Form
Cc: Mr. Harold Burge, Manager
Division of Air Quality
195 North 1950 West
Salt Lake City, Utah 84116
Electronic Submittal
rcvd email 1/25/24
REVIEWED
Initials JBR Date 1/29/24
Comp Status Meets
File # 10005 Blue 2
OOOO under sep rpt
Semiannual Equipment Leak/VOC Monitoring Report pursuant to NSPS OOOOa
This report is being submitted to meet the requirements in 40 CFR 60, Subpart OOOOa, Standards of
Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification, or
Reconstruction Commenced after September 18, 2015. This report covers the period from July 1, 2023
through December 31, 2023. Below is the specific information required by §60.5422a(a)-(c).
60.487a(c)(1) Process unit identification
• Fractionation
• Inlet
• Storage
60.487a(c)(2)(i)-(iv), (vii)-(viii), and 60.5422a(c)
Provided in reporting template submitted via CEDRI.
60.487a(c)(2)(xi)
See attached.
60.487a(c)(3)
There were not process unit shutdowns during the reporting period.
60.487a(c)(4)
Component Type Component Count
(period ending 6/30/2023)
Component Count
(period ending 12/31/2023)
Valve 2587 2524
Pump 6 6
Connector 9372 9382
Facility Record No. *
(Field value will
automatically
generate.)
Facility Name * Address of Processing
Plant*Address 2 City * County *
State
Abbreviation*Zip Code *
Responsible
Agency
Facility ID
(State Facility
Identifier)
Beginning Date of
Reporting Period *
Ending Date of
Reporting Period *
Please enter any
additional
information
Enter associated file
name reference.
e.g.: ABC Company e.g.: 123 Main Street e.g.: Suite 100 e.g.: Brooklyn e.g.: Kings County e.g.: NY e.g.: 11221 e.g.: 01/01/2016 e.g.: 06/30/2016 e.g.: filename.pdf
1 Altamont Main Gas P17790 West 3750 NorthPO Box 587 Altamont Duchesne UT 84001 UDEQ 07/01/2023 12/31/2023 2024‐01‐22 Altamont Main OOOOa semiannu
FACILITY INFORMATION ADDITIONAL INFORMATION
40 CFR Part 60 ‐ Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 ‐ 60.5422a(a) Semiannual Report
The asterisk (*) next to each field indicates that the corresponding field is required.
Facility Record No. *
(Select from
dropdown list)
Month Identification*
(Select from
dropdown list)
Number of pressure
relief devices for
which leaks were
detected *
(§60.5422a(c)(1))
Number of pressure
relief devices for
which leaks were not
repaired *
(§60.5422a(c)(2))
Number of valves for
which leaks were
detected *
(§60.487a(c)(2)(i))
Number of valves for
which leaks were not
repaired *
(§60.487a(c)(2)(ii))
Number of pumps for which
leaks were detected *
(§60.487a(c)(2)(iii))
Number of pumps for
which leaks were not
repaired *
(§60.487a(c)(2)(iv))
Number of connectors
for which leaks were
detected *
(§60.487a(c)(2)(vii),
§60.5422a(a))
Number of connectors for
which leaks were not
repaired *
(§60.487a(c)(2)(viii),
§60.5422a(a))
e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5
1 July 00511 0 15 0
1 August 0 0 23 0 1 0 14 0
1 September 00500 0 10 0
1 October 00700 0 7 1
1 November 0 0 32 0 0 0 4 1
1 December 0 0 10 0 0 0 2 0
40 CFR Part 60 ‐ Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 ‐ 60.5422a(a) Semiannual Report
The asterisk (*) next to each field indicates that the corresponding field is required.
EQUIPMENT INFORMATION
Repair Delay - Current List (R323_1)Report Date:11/28/2023
Report Parameters
Unit:All Units
UNIT:FRACTIONATION AREA:
Unrepairable
Delayed
for
Shutdown
Expected
Repair
Last
Date
Last
PPM
Ref.
No.
Date
DelayedTag#:Class Location Reason For Delay Approved By
Drawing
000148.
0E
CONEC
T
SE SDE OF V-19 ON
DECK
11/13/23 1330 Repair is technically infeasible
without a process unit shutdown.
Repair of this equipment shall occ
BEN BARNS 11/15/2
3
6/30/24
FRACTIONATION
000253.
01R
VALVE N SDE OF FIN FAN E OF
DEPROP TWR
11/9/23 43299 Repair is technically infeasible
without a process unit shutdown.
Repair of this equipment shall occ
BEN BARNS 6/14/23 6/30/24
FRACTIONATION
002570.
00
VALVE NE OF V-1 DEETH
TOWER IN PIPE RACK
ABOVE 1ST INSULATED
LINE MD
11/14/23 9770 Repair is technically infeasible
without a process unit shutdown.
Repair of this equipment shall occ
BEN BARNES 7/31/23 6/30/24
FRACTIONATION
This report produced using LeakDAS.
Last modified: 4/20/2021 Page 1 of 2
Repair Delay - Current List (R323_1)Report Date:11/28/2023
Report Parameters
Unit:All Units
UNIT:INLET AREA:NORTH INLET
Unrepairable
Delayed
for
Shutdown
Expected
Repair
Last
Date
Last
PPM
Ref.
No.
Date
DelayedTag#:Class Location Reason For Delay Approved By
Drawing
001471.
0B
CONEC
T
N SDE OF HP SLUG
CATCHER
11/10/23 1633 Repair is technically infeasible
without a process unit shutdown.
Repair of this equipment shall occ
BEN BARNES 10/30/2
3
6/30/24
INLET
This report produced using LeakDAS.
Last modified: 4/20/2021 Page 2 of 2