Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-006261
EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 02/29/2024 1000244 Hart's #40/#80140 585 E. State St. American Fork, UT 84003 801-592-5948 John Hreinson Max LaRou UT-412 50 P.S.I. CLR 0 78 15 78 0 0 0 30 78 0 0 0 PASS Race Fuel 0 69 15 69 0 0 0 30 69 0 0 0 PASS REG E., W. Manifold 0 58 15 58 0 0 0 30 58 0 0 0 PASS DYE DSL E., W. Manifold 0 46 15 46 0 0 0 30 46 0 0 0 PASS DSL E., W. Manifold 0 34 15 34 0 0 0 30 34 0 0 0 PASS 02/29/2024 Max LaRou UT-412 EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 03/01/2024 1000244 Hart's #40 585 E. State St. American Fork, UT 84003 801-592-5948 John Hreinson Max LaRou UT-412 50 P.S.I. PRM E., W. Manifold 0 74 15 74 0 0 0 30 74 0 0 0 PASS 03/01/2024 Max LaRou UT-412 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV0//'DQGHOHFWURQLFOLQHOHDNGHWHFWRUV(//'ZLWKVXEPHUVLEOH WXUELQHSXPS673V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\POOLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGVWLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGVWKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHWWULSZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Hart’s #40 585 E. State St. American Fork, UT 84003 1000244 Rhinehart Oil Co. P.O. Box 418 American Fork, UT 84003 801-592-5948 02/29/2024 1 CLR V.R. FX1V 4 29 19 200 2 11 4 4 4 4 4 2 Race Fuel V.R. FX1V 4 30 16 180 2 12 6 4 4 4 4 4 REG V.R. PLLD 4 31 2 4 4 4 5 DYE DSL V.R. PLLD 4 30 2 4 4 4 6 DSL V.R. PLLD 4 31 2 4 4 4 7 PRM V.R. PLLD 4 30 2 4 4 4 Max LaRou UT-412 pei.org 43 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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est Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Harts #40 1000244 02/28/2024 1 E-Free 5gal Frnk 4 4 4 4 4 2 Race Fuel 5gal Frnk 4 4 4 4 4 4 4 30"wc 0min 29.77"wc 5min 5min .23"wc 4 3 Prm 5gal Frnk 4 4 4 4 4 4 Reg 5gal Frnk 4 4 4 4 4 4 Reg 5gal Frnk 4 4 4 4 4 5 Dye Dsl 5gal Frnk 4 4 4 4 Dominic Salas UT-378 pei.org 43 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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est Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Harts #40 1000244 02/28/2024 5 Dye Dsl 5gal Frnk 4 4 4 4 4 6 Dsl 5gal Frnk 4 4 4 4 4 6 Dsl 5gal Frnk 4 4 4 4 4 Dominic Salas UT-378 pei.org 45 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-5 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·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´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH BALL FLOAT VALVE INSPECTION 7DQNWRSILWWLQJVDUHYDSRU WLJKWDQGOHDNIUHH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWFDJHIUHHRIGHEULV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOLVIUHHRIKROHVDQGFUDFNV DQGPRYHVIUHHO\LQFDJH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9HQWKROHLQSLSHLVRSHQDQG QHDUWRSRIWDQN"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWSLSHLVSURSHU OHQJWKWRUHVWULFWIORZDW FDSDFLW\" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIDXWRPDWLFVKXWRIIGHYLFHZLOOVKXWRIIIORZDWFDSDFLW\ 8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIIORZUHVWULFWLRQGHYLFHZLOOUHVWULFWIORZDWFDSDFLW\ Comments: Precision Testing Technologies Inc.801-886-9224 Harts #40 1000244 02/28/24 E-Free 1 11627 92" Frnk 4 4 4 4 4 4 4 Race Fuel 2 11627 92" Frnk 4 4 4 4 4 4 4 Prm 3 11627 92" Frnk 4 4 4 4 4 4 4 Reg 4 20159 119" Frnk 4 4 4 4 4 4 4 Reg 4 20159 119" Frnk 4 4 4 4 4 4 4 Dye Dsl 5 20159 119" Frnk 4 4 4 4 4 4 4 Dominic Salas UT-378 Harts #40Harts #40 pei.org 45 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-5 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·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´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH BALL FLOAT VALVE INSPECTION 7DQNWRSILWWLQJVDUHYDSRU WLJKWDQGOHDNIUHH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWFDJHIUHHRIGHEULV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOLVIUHHRIKROHVDQGFUDFNV DQGPRYHVIUHHO\LQFDJH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9HQWKROHLQSLSHLVRSHQDQG QHDUWRSRIWDQN"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWSLSHLVSURSHU OHQJWKWRUHVWULFWIORZDW FDSDFLW\" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIDXWRPDWLFVKXWRIIGHYLFHZLOOVKXWRIIIORZDWFDSDFLW\ 8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIIORZUHVWULFWLRQGHYLFHZLOOUHVWULFWIORZDWFDSDFLW\ Comments: Precision Testing Technologies Inc.801-886-9224 Harts #40 1000244 02/28/24 Dye Dsl 5 20159 119" Frnk 4 4 4 4 4 4 4 Dsl 6 20159 119" Frnk 4 4 4 4 4 4 4 Dsl 6 20159 119" Frnk 4 4 4 4 4 4 4 Dominic Salas UT-378 Harts #40Harts #40 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Hart’s #40 1000244 1 CLR V.R. TLS 350 11,627 92" 4 4 4 4 76 1/4" 4 2" 4 4 2 Race Fuel V.R. TLS 350 11,627 92" 4 4 4 4 76 1/4" 4 2" 4 4 4 REG V.R. TLS 350 20,159 119" 4 4 4 4 101 7/8" 4 2" 4 4 5 DYE DSL V.R. TLS 350 20,159 119" 4 4 4 4 101 7/8 4 2 4 4 Max LaRou UT-412 02/29/2024 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Hart’s #40 1000244 6 DSL V.R. TLS 350 20,159 119" 4 4 4 4 101 7/8" 4 2" 4 4 7 PRM V.R. TLS 350 11,627 92" 4 4 4 4 76 1/4" 4 2" 4 4 Max LaRou UT-412 02/29/2024 pei.org 51 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-11 EMERGENCY STOP SWITCH OPERATION INSPECTION )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVSURFHGXUHLVWRYHULI\WKHRSHUDWLRQRIDOOHPHUJHQF\VWRSVZLWFKHVEXWWRQV(VWRSV(DFK(VWRSPXVWGLVFRQQHFWSRZHUWRGLV SHQVHUVVXEPHUVLEOHWXUELQHSXPSV673VDQGDOOQRQLQWULQVLFDOO\VDIHHOHFWULFDOHTXLSPHQWLQFODVVLILHGDUHDV7HVWHDFK(VWRSVHSD UDWHO\6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH (VWRS1XPEHURU,' /RFDWLRQ (VWRSVODEHOHGDQGORFDWHG ZKHUHHDVLO\DFFHVVLEOH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 6\VWHPLVIXOO\SRZHUHGDQG LQQRUPDORSHUDWLQJFRQGLWLRQ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $IWHUDFWLYDWLQJ(VWRSSRZHUKDVEHHQGLVFRQQHFWHGIURP D$OOGLVSHQVLQJGHYLFHVRQDOO LVODQGV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R E$OO673VIRUDOOIXHOJUDGHV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R F$OOSRZHUFRQWURODQGVLJQDO FLUFXLWVDVVRFLDWHGZLWKWKHGLV SHQVLQJGHYLFHVDQGWKH673V" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R G$OORWKHUQRQLQWULQVLFDOO\ VDIHHOHFWULFDOHTXLSPHQWLQ FODVVLILHGDUHDVVXUURXQGLQJ IXHOGLVSHQVLQJGHYLFHV" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $OOLQWULQVLFDOO\VDIHHOHFWULFDO HTXLSPHQWUHPDLQVHQHUJL]HG DIWHU(VWRSDFWLYDWLRQ" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $IWHUWHVWLQJKDV(VWRSEHHQ UHVHWDQGSRZHUUHHVWDEOLVKHG WRQRUPDORSHUDWLQJFRQGLWLRQ" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµWROLQHVDGLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Hart’s #40 1000244 801-886-9224Precision Testing Technologies Inc.03-01-24 1 Ext. Frt. Door Max LaRou UT-412