Loading...
HomeMy WebLinkAboutDERR-2024-006247Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name WIND RIVER PETROLEUM Address 5097 S 900 E, SUITE 200 SALT LAKE CITY, UT 84117 Contact WIND RIVER PETROLEUM Phone Email jkuddes@topstopstores.com TANK LOCATION Name TOP STOP C-40 Address 1355 E HWY 40 VERNAL, UT 84078 A Operator JESSICA KUDDES Phone (435) 753-1025 B Operator DUSTI BURTON Phone (801) 272-9229 Facility ID: 9000221 Inspection Date: 04/10/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 Gasoline No None None No No None None 2 - 3/4 Gasoline No None None No No None None 3 - 5/6 Gasoline No None None No No None None 4 - 7/8 Gasoline No None None No No None None 5 - 9/10 Diesel No None None No Yes None None 6 - 11/12 Diesel No None None No Yes None None 7 - 13/14 Diesel No None None No Yes None None 8 - 15/16 Diesel No None None No Yes None None 9 - 17/18 Diesel No None None No Yes None None TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 1950 / 17000 / Substance Stored Gasoline / Regular Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Overfill alarm / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None 2024-04-10 Page 1 of 6 Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 1950 / 10000 / Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Overfill alarm / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None Tank ID/Alt ID 3 / 3 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 1950 / 12000 / Substance Stored Gasoline / Premium Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Overfill alarm / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None Tank ID/Alt ID 4 / 4 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 1950 / 12000 / Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Overfill alarm / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None Tank ID/Alt ID 5 / 5 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 2002 / 9600 / Substance Stored Diesel / Off-road Diesel Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Containment Sump / Overfill alarm / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None INSPECTION COMMENTS 2024-04-10 Page 2 of 6 None 2024-04-10 Page 3 of 6 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 2 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 2 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 3 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 4 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 4 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 5 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 1 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 2 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 3 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 3 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 4 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No 2024-04-10 Page 4 of 6 Tank 5 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 5 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes DISPENSER RESPONSES MONTHLY LEAK DETECTION MONITORING Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 3 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 5 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS TANK 2 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 4 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None 2024-04-10 Page 5 of 6 Prepared by fueloperator.com Inspection Information Inspector:Perdue, Laura Record Created:April 10, 2024, 9 a.m. Inspection Date:April 10, 2024 2024-04-10 Page 6 of 6