Loading...
HomeMy WebLinkAboutDDW-2025-010243 Mailing Address: P.O. Box 144830 • Salt Lake City, UT 84114-Telephone (801) 536-4200 • Fax (801-536-4211 • T.D.D. (801) 536- www.deq.utah.gov Printed on 100% recycled paper State of Utah Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Tim Davis Executive Director DIVISION OF DRINKING WATER Nathan Lunstad, Ph.D., P.E. Director October 22, 2025 CERTIFIED MAIL Lisa Chauvin Dammeron Valley Water Works LLC 1 Dammeron Vly East Dammeron Valley, UT 84783 Subject: NOTICE OF VIOLATION – Failure to Fix Significant Deficiency Treatment Technique Violation, Water System #UTAH27030 Lisa Chauvin: Our records indicate that your system is in violation of the State of Utah Public Drinking Water Rules as follows: On May 8, 2025, Dammeron Valley Water Works LLC received three significant deficiencies. The system was notified of these deficiencies on May 10, 2025. Two of these deficiencies remain uncorrected: • V011 End of storage tank overflow lacks a clearance of between 12 and 24 inches from ground surface ST002 • V011 End of storage tank overflow lacks a clearance of between 12 and 24 inches from ground surface ST003 Utah Public Drinking Water Rules require all significant deficiencies to be corrected within 120 days of the date of notification or the system must enter a corrective action plan (CAP) with the Division to address the significant deficiencies as specified in R309-215-16(3)(a)(v). The system chose not to request a corrective action plan or submit a correction for this deficiency within the given timeframe. This results in the system being assessed a treatment technique violation in accordance with R309-215-16(4)(a) and the assessment of 50 Improvement Priority System (IPS) points to the system’s IPS Report. Be advised this could adversely affect your water system’s rating (R309-400). As a result of this Tier 2 violation, the system must provide public notice as soon as practical, but no later than 30 days after the system learns of the violation. If the public notice is posted, the notice must remain in place for as long as the violation or situation persists, but in no case for less than seven days, even if the violation or situation is resolved (see R309-220-6(1)(a) and R309- 220-6(1)(b)). This public notice requirement cannot be waived once a violation occurs. Proof of Lisa Chauvin Page 2 of 2 public notification must be provided to the Division at (ddwreports@utah.gov) within 30 days of notifying the water system customers and resubmitted each quarter the deficiencies remain unresolved. Failure to submit quarterly public notification may result in a public notice violation and an additional 50 points on the IPS report. If any of the above deficiencies have been corrected, please complete the enclosed IPS Deficiency Correction Notice and submit the information to the Division at ddwips@utah.gov immediately. We ask that you respond to this letter as soon as possible. Please contact Jennifer Yee at (385) 515-1501 or ddwips@utah.gov if you have questions or need assistance. Sincerely, Helen Lau Compliance Section Manager Enclosures: IPS Report Deficiency Correction Form Tier 2 Public Notice Template cc: Jeremy Roberts, Southwest Utah Public Health Departmentjroberts@swuhealth.gov Paul Wright, P.E., District Engineer,pwright@utah.gov Helen Lau (Oct 22, 2025 16:15:06 MDT) Utah Department Of Environmental Quality Division Of Drinking Water Admin Contacts IPS 2020 Report IPS Report DAMMERON VALLEY WATER WORKS LLC PWS ID: UTAH27030 Rating: Approved 05/23/1989 Active Legal Contact DAMMERON VALLEY WTR WORKS LISA CHAUVIN 1 DAMMERON VLY EAST DAMERON VALLEY, UT 84783 Phone: 435-574-2295 County: WASHINGTON COUNTY System Type: Community Population: 885 Site Updates Last Inventory Update: 09/03/2025 Last Surveyor Update: 05/08/2025 Surveyor: CHRIS BOWLES Operating Period: 1/1 - 12/31 Last IPS Update: 10/22/2025 14:22:26 Consumptive Use Zone Irrigation Zone: null Date: Name Title Office Emergency Email CHAUVIN, LISA 435-574-2295 water@dammeronvalley.com IPS Summary Total IPS Pts: 190 Admin & Physical Facilities Quality & Monitoring Significant Deficiency 90 0 100.0 DEQ | Drinking Water Run Date: 10/22/2025 16:07:57 | Rating: Approved UTAH27030 DAMMERON VALLEY WATER WORKS LLC page 1 of 3 Physical Facility Points 2020 Total Pts: 90 Facility Facility Name Status Points Effective DS001 UTAH27030 DISTRIBUTION SYSTEM A 30.0 Code Description Severity Comments Determined Date Not Assessed Assessed M019 FAILURE TO SUBMIT REQUIRED WATER USE DATA ANNUALLY OR VERIFY DATA ACCURACY MIN DUE DATE NOVEMBER 30, 2023 10/01/2022 15 M007 CCC-LACKS ON- GOING ENFORCEMENT IMPLEMENTATION MIN Needs to create a bigger inventory of connections and create a Letter to mail to customers to start and continue enforcement. 05/08/2025 15 ST002 NORTH RIDGE TANK A 25.0 Code Description Severity Comments Determined Date Not Assessed Assessed V011 END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG Flows to dry creek next to road no Air Gap 05/08/2025 25 ST003 NORTH RIDGE TANK #2 A 25.0 Code Description Severity Comments Determined Date Not Assessed Assessed V011 END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG No Air Gap where it discharges to Dry creek bed, evidence of wash and silt from storm run off water in dry creek bed. Photo's will be attached on follow up email 05/08/2025 25 WS004 NORTH RIDGE 3A A 5.0 Code Description Severity Comments Determined Date Not Assessed Assessed S024 NO CHECK VALVE ON WELL DISCHARGE PIPING MIN Missing the check valve 10/06/2022 5 WS005 NORTH RIDGE #4 A 5.0 Code Description Severity Comments Determined Date Not Assessed Assessed S024 NO CHECK VALVE ON WELL DISCHARGE PIPING MIN No check valve visible.05/08/2025 5 Significant Deficiency Violations Total Pts: 100 ID Violation Code Deficiency Determined Point Effective ST002 45 FAILURE ADDRESS DEFICIENCY (GWR) V011 END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE 10/22/2025 50.0 ST003 45 FAILURE ADDRESS DEFICIENCY (GWR) V011 END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE 10/22/2025 50.0 DEQ | Drinking Water Run Date: 10/22/2025 16:07:57 | Rating: Approved UTAH27030 DAMMERON VALLEY WATER WORKS LLC page 2 of 3 Operator Certification Type Level Required Highest Certificate Distribution Dist 1 Dist 4 Treatment Treat 1 Open Compliance Schedule Type Required Activities Severity Created Due Complete PFAS Initial Monitoring SUBMIT PFAS INITIAL MONITORING SAMPLES 04/26/2024 04/26/2027 Physical deficiency schedule END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG 05/10/2025 09/07/2025 Physical deficiency schedule END OF STORAGE TANK OVERFLOW LACKS A CLEARANCE OF BETWEEN 12 AND 24 INCHES FROM GROUND SURFACE SIG 05/10/2025 09/07/2025 Corrective Action Agreement CAA INSTALL EQUIPMENT 11/30/2023 Corrective Action Agreement CAA SUBMIT PLANS 11/30/2022 Corrective Action Agreement CAA COLLECT AND RECORD WATER USE DATA MIN 11/30/2023 DEQ | Drinking Water Run Date: 10/22/2025 16:07:57 | Rating: Approved UTAH27030 DAMMERON VALLEY WATER WORKS LLC page 3 of 3