Loading...
HomeMy WebLinkAboutDDW-2025-010227System Number 26059 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10 Number of other connections - - - 0 ERCs of other connections 0.0 Total Equivalent Residential Connections (ERCs)10.0 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 800 5.6 400 4,000 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > 0 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > 0%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > 0.00 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > 0.00 2 Irrigation zone 2 3 4 5 6 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 0 0.0 0 0 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone Maximum fire suppression duration (in hours) for water system or pressure zone Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > 0 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 800 5.6 400 4,000 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 5.6 gpm Existing Source Capacity 21.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 378.0% Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. System Name Source Wasatch Mobile Home Park-2025 Storage (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Source (indoor + outdoor) Storage MIN. REQUIREMENTS FOR INDOOR WATER USE MINIMUM REQUIREMENTS FOR WATER SYSTEM Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* (Example: water use of 2 factories equals to water use of 55 homes.) Source MIN. REQUIREMENTS FOR IRRIGATION USE Yes No Yes No Wasatch Mobile Home Park UTAH26059-2025 Capacity Calculations Page 1 of 2 10/20/2025 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 4,000 gal Existing Storage Capacity 0 gal Storage Capacity Deficit 4,000 gal Required Fire Storage 0 gal NO Existing % of Total Req'd 0.0% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person* GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 0 30 0 0.00 0 0.0 20 0 10 0 0.00 0 0.0 5 0 2.5 0 0.00 0 0.0 N/A 100 N/A 50 0.13 0 0.0 Number of people per camp site 0 Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 7 3.5 8.8 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)21 4.1 Projected ERCs Calculation (optional)WS001 MHP WELL 1 21 Total Projected ERCs 0 Existing Residential Connections Obligated Future ERCs (enter below) Maximum ERCs (assuming indoor use only) 37.8 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)0 Tank 2 hydropneumatic tanks on system for pressure but no storage capacity Semi-Developed Camp w/ flush toilets Wasatch Mobile Home Park-2025 Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Wasatch Mobile Home Park UTAH26059-2025 Capacity Calculations Page 2 of 2 10/20/2025