Loading...
HomeMy WebLinkAboutDERR-2024-006068Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name FAST STOP 1129 Address PO BOX 150545 OGDEN, UT 84415 Contact FAST STOP 1129 Phone Email Fuel@faststop.us TANK LOCATION Name FAST STOP 1129 Address 604 W LOGAN RD GARDEN CITY, UT 84028 A Operator LEIGHANNE TOMAZICH Phone (801) 920-9850 B Operator ROBIN HARDISTER Phone (801) 391-8237 Facility ID: 0100658 Inspection Date: 04/11/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 12000 / Substance Stored Gasoline / Regular Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Automatic shutoff / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankATG / TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 12000 / Substance Stored Gasoline / Premium Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Automatic shutoff / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankATG / TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None 2024-04-16 Page 1 of 5 Tank ID/Alt ID 3 / 3 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 12000 / Substance Stored Gasoline / Non-Ethanol Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Automatic shutoff / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankATG / TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None Tank ID/Alt ID 4 / 4 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 12000 / Substance Stored Diesel / Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Not in contact with soil LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Automatic shutoff / No PST Fund/Other Type No / None Tank/Pipe Rel Det TankATG / TankLDNotListed PipeLDNotListed CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-04-16 Page 2 of 5 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 2 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 2 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? No Tank 3 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 4 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 4 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? No Tank 1 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? No Tank 2 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 3 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 3 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? No Tank 4 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No DISPENSER RESPONSES 2024-04-16 Page 3 of 5 MONTHLY LEAK DETECTION MONITORING Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 3 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS TANK 1 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 1 No Photos Question:Does the spill bucket have a valid 3-year test, valid monthly monitoring for DW buckets, or the tank is exempt? Comments:None TANK 2 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 2 No Photos Question:Does the spill bucket have a valid 3-year test, valid monthly monitoring for DW buckets, or the tank is exempt? Comments:None TANK 3 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 3 No Photos Question:Does the spill bucket have a valid 3-year test, valid monthly monitoring for DW buckets, or the tank is exempt? Comments:None TANK 4 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 4 No Photos Question:Does the spill bucket have a valid 3-year test, valid monthly monitoring for DW buckets, or the tank is exempt? Comments:None 2024-04-16 Page 4 of 5 Prepared by fueloperator.com Inspection Information Inspector:Rasmussen, DeAnn Record Created:April 16, 2024, 7:06 a.m. Inspection Date:April 11, 2024 2024-04-16 Page 5 of 5