Loading...
HomeMy WebLinkAboutDERR-2024-005976 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-145-24 April 15, 2024 Robin Hardister Fast Stop Stores P.O. Box 150545 Ogden, Utah 84415 Re: Notice of Approval to Remove Delivery Prohibition Tags Fast Stop #1123, located at 880 West 3300 South, South Salt Lake City, Utah Facility Identification No. 4001368 Dear Robin Hardister: The Division of Environmental Response and Remediation (DERR) has received all the documentation necessary to issue the attached certificate of compliance for the 12,000-gallon regular, 7000-gallon diesel, and 5000-gallon premium underground storage tanks at this facility. This notice satisfies the requirement for written authorization to remove the delivery prohibition tags in accordance with Utah Admin. Code R311-206-8(6). Please remove and discard anytags that were attached to the fill for these tanks during installation. If you have additional questions, please contact the DERR project manager, identified on the red tag, at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/KV/ss Enclosure: Certificate of Compliance Packet cc: Ron Lund, Environmental Health Director, Salt Lake County Health Department 2024 UST CERTIFICATE OF COMPLIANCE ISSUED TO: ROBIN HARDISTER FAST STOP STORES PO BOX 150545 OGDEN, UT 84415 LOCATION OF TANKS: FAST STOP 1123 880 W 3300 S SOUTH SALT LAKE UT 84119 Facility ID: 4001368 Tank# Capacity Substance Desc Compliance Financial Assurance Mechanism 1 2A 2B 12000 7000 5000 Gasoline Diesel Gasoline Yes PST Fund Yes PST Fund Yes PST Fund This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federal UST regulations. Possession of this certificate does not signify coverage under the Utah PST Fund. Cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY Underground Storage Tank Inspection Verification Form Owner Name: FAST STOP STORES Owner Address: PO BOX 150545 OGDEN, UT 84415 Operator A: ROBIN HARDISTER/ (801) 391-8237 / 1/1/2027 Facility Name: FAST STOP 1123 Street Address: 880 W 3300 S Facility ID: 4001368 SOUTH SALT LAKE, UT 84119 Operator B: ROBIN HARDISTER/ (801) 391-8237 / 1/1/2027 Owner Email: ROBINW@FASTSTOP.US UTM Coordinates X/Y: 422559 / 4505841 -----------------------------------------------------Disp ID/Alt Substance UDC Pipe Flex Loe Install Date UDC Install Date Fire Sat UDC Test Disp Flex CP ID Valve Present Test 1 -1/2 2-3/4 3-5/6 Gasoline Gasoline Gas/Diesel Yes Yes Yes Steel Flex in Sump Steel Flex in Sump Steel Flex in Sump 03/26/2024 03/26/2024 03/26/2024 Yes Yes Yes No No No 3/26/2024 3/26/2024 3/26/2024 4 -7/8 Gas/Diesel Yes Steel Flex in Sump 03/26/2024 Yes No 3/26/2024 -----------------------------------------------------Tank ID/Alt ID: 4 / 1 EGen/AST/Stat No/ No/ No Pipe Material-Mod: Flexible Plastic -Double-Walled Siphon/Compart: No/ No PW/Stagel: Yes Tank Status: Currently In Use Installed/Cap/Loe: 1/11/2024 / 12000 / South Substance Stored: Gasoline/ Regular Co-axial Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root/ TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 4/10/2024 LTTTest: Tank ID/Alt ID: 5 / 2A Siphon/Compart: No/ Yes LLD Test: 04/10/2024 EGen/AST/Stat No/ No/ No PW/Stagel: Yes Tank Status: Currently In Use Installed/Cap/Loe: 1/12/2024 / 7000 / Northwest Substance Stored: Diesel/ Diesel #2 (U.L.S.) Co-axial Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root/ TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 4/10/2024 LTTTest: Tank ID/Alt ID: 6 / 28 Siphon/Compart: No/ Yes LLD Test: 04/10/2024 EGen/AST/Stat No/ No/ No PW/Stagel: Yes Tank Status: Currently In Use Installed/Cap/Loe: 1/12/2024 / 5000 / Northeast Substance Stored: Gasoline/ Premium Co-axial Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root/ TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 4/10/2024 LTTTest: LLD Test: 04/10/2024 4/15/2024 Page 1 of 1 Pipe Type/STP Cont: Pressurized/ Yes STP Flex Connectors: Steel Flex in Sump LLD Model: Veeder Root PLLD Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Overfill alarm / No PST Fund/Other Type: Yes/ Tank/Pipe Rel Det: Interstitial DW / Interstitial DW / ALD STP Sump Test: 03/26/2024 Spill Bk Test: Overfill Test: 4/10/2024 CP Tank Test: CP Pipe Test: Pipe Material-Mod: Flexible Plastic -Double-Walled Pipe Type/STP Cont: Pressurized/ Yes STP Flex Connectors: Steel Flex in Sump LLD Model: Veeder Root PLLD Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Overfill alarm / No PST Fund/Other Type: Yes/ Tank/Pipe Rel Det: Interstitial DW / Interstitial DW / ALD STP Sump Test: 03/26/2024 Spill Bk Test: Overfill Test: 4/10/2024 CP Tank Test: CP Pipe Test: Pipe Material-Mod: Flexible Plastic -Double-Walled Pipe Type/STP Cont: Pressurized/ Yes STP Flex Connectors: Steel Flex in Sump LLD Model: Veeder Root PLLD Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Overfill alarm / No PST Fund/Other Type: Yes/ Tank/Pipe Rel Det: Interstitial DW / Interstitial DW / ALD STP Sump Test: 03/26/2024 Spill Bk Test: Overfill Test: 4/10/2024 CP Tank Test: CP Pipe Test: