Loading...
HomeMy WebLinkAboutDERR-2025-006769 WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 PRODUCT PIPING INTEGRITY TESTING Facility Name: Salt Lake City Cemetery Owner: Salt Lake Public Utilities Address: 200 North N Street Address: 1530 West Temple City, State, Zip: Salt Lake City, Utah 84103 City, State, Zip: Salt Lake City, Utah 84115 Facility I.D.#: 4000842 Phone #: 801-535-6904 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/2025 This procedure is to test the integrity of product piping. Tests were performed with Petro-Tite line tester. Tank Number 1 2 Product Stored RUL DSL Piping Run Only Only Piping Type FRP FRP Test Pressure (PSI) 50 50 Test Duration (minutes) 30 30 Leak Rate (GPH) 0.002 0.002 Test Results ☒Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Taber DeHart, UT-0394 RUL DSL RULDSL WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 MECHANICAL AND ELECTRONIC LINE LEAK DETECTOR PERFORMANCE TESTS Facility Name: Salt Lake City Cemetery Owner: Salt Lake Public Utilities Address: 200 North N Street Address: 1530 West Temple City, State, Zip: Salt Lake City, Utah 84103 City, State, Zip: Salt Lake City, Utah 84115 Facility I.D.#: 4000842 Phone #: 801-535-6904 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/2025 Line Number Leak Detector Manufacturer ☐MLLD ☒ELLD ☐MLLD ☒ELLD ☐MLLD ☐ELLD ☐MLLD ☐ELLD MLLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure Check valve holding pressure Line resiliency (ml) (line bleedback volume as measured from check valve holding pressure to 0 psig) metering pressure before going to full operating pressure as pressure for at least 60 seconds when the simulated leak is ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No Does the leak detector reset (trip) when the line pressure is bled off to zero psig? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No Does STP properly clycle on/off under normal fuel system operating conditions? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" answer to any of the above questions indicates that the MLLD fails the test. ELLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure 31 32 How many test cycles are observed before alarm/shutdown occurs? 1 1 ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" answer to the above question indicates that the ELLD fails the test. Does the simulated leak cause an STP shutdown? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No Test Results Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature Taber DeHart WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Salt Lake City Cemetery Owner: Salt Lake Public Utilities Address: 200 North N Street Address: 1530 West Temple City, State, Zip: Salt Lake City, Utah 84103 City, State, Zip: Salt Lake City, Utah 84115 Facility I.D.#: 4000842 Phone #: 801-535-6904 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/2025 This procedure is to determine whether the automatic tank gauge (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank monitor stems that touch the bottom of the tank when in place. Tank Number 1 2 Product Stored RUL DSL ATG Brand and Model TLS-350 TLS-350 1. Tank Volume, gallons 6,215 6,215 2. Tank Diameter, inches 90.75 90.75 ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 76.5 76.5 corresponds with the value programmed in the ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 1 1 corresponds with the value programmed in the ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No Test Results ☒Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Taber DeHart, UT-0394 WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 LIQUID SENSER FUNCTIONALITY TESTING Facility Name: Salt Lake City Cemetery Owner: Salt Lake Public Utilities Address: 200 North N Street Address: 1530 West Temple City, State, Zip: Salt Lake City, Utah 84103 City, State, Zip: Salt Lake City, Utah 84115 Facility I.D.#: 4000842 Phone #: 801-535-6904 Westech 801-266-2545 9/11/2025 Sensor Location L-1 INT L-2 INT L-3 STP L-4 STP L-5 UDC Product Stored DSL RUL DSL RUL RUL/DSL Type of Sensor ☐Discriminating ☒ Non-Discrimi- ☐Discriminating ☒ Non-Discrimi- ☐Discriminating ☒ Non-Discrimi- ☐Discriminating ☒ Non-Discrimi- ☐Discriminating ☒ Non-Discrimi- ☐Discriminating ☐ Non-Discrimi- ☐Discriminating ☐ Non-Discrimi- Test Liquid ☒ Water ☐ Product ☒ Water ☐ Product ☒ Water ☐ Product ☒ Water ☐ Product ☒ Water ☐ Product ☐ Water ☐ Product ☐ Water ☐ Product Is the ATG Console clear of any active or recurring warnings or alarms regarding the leak sensor? If the sensor is in alarm ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No Any “No” answers indicate the sensor fails the test. Test Results: ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Taber DeHart, UT-0394 Taber DeHart WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 SPILL BUCKET INTEGRITY TESTING HYDROSTATIC TEST METHOD SINGLE- AND DOUBLE-WALLED VACUUM TEST METHOD Salt Lake City Cemetery Salt Lake Public Utilities 200 North N Street 1530 West Temple Salt Lake City, Utah 84103 Salt Lake City, Utah 84115 4000842 801-535-6904 Westech 801-266-2545 9/11/2025 5-Gallon 5-Gallon Construction ☐Double-walled ☒☐Double-walled ☒☐Double-walled ☐☐Double-walled ☐ Test Type ☒☐Vacuum ☐Double-walled ☐ ☒☐Vacuum ☐Double-walled ☐ ☐☐Vacuum ☐Double-walled ☐ ☐☐Vacuum ☐Double-walled ☐ Spill Bucket Type ☒Product ☐☒Product ☐☐Product ☐☐Product ☐ ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No parts or separation of the bucket from ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No Tank Riser cap included in test? ☒☐☐☒☐☐☐☐☐☐☐☐ Drain valve included in test? ☐Yes ☐No ☒☐Yes ☐No ☒☐Yes ☐No ☐☐Yes ☐No ☐ Starting Level Test Start Time Test End Time Test Period Level Change Test Results ☒Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Taber DeHart, UT-0394 WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054