Loading...
HomeMy WebLinkAboutDDW-2025-008654System Number 12002 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -647 Number of other connections - - - 19 ERCs of other connections 20.0 Total Equivalent Residential Connections (ERCs)667.0 gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 370.6 400 266,800 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation 647 Percentage of Residential ERCs using DW for irrigation 100%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.10 1 Total irrigated acreage of other connections (park, school, etc.)10.00 2 Irrigation zone 3 3 4 5 6 gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 488 253.2 253 188,842 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,000 Maximum fire suppression duration (in hours) for water system or pressure zone 1 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - -60,000 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 1,288 623.8 653 515,642 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 623.8 gpm Existing Source Capacity 840.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 134.7% Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* equals to water use of 55 homes.) MIN. REQUIREMENTS FOR IRRIGATION USE System Name Mona Town (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Source (indoor + outdoor)Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Yes No Yes No Enter number of non-residential connections, e.g., 2 industrial connections. Convert "Number of other connections" (Cell E9) to ERCs here. [ERCs of other connections = peak day demand of other connections in gal per day / 800 gpd] Enter estimated irrigated acre per here. Enter total irrigated acres of other connections here. Enter fire flow in gpm. Enter duration in hours. from the pick list. See "Irrigation Demands & Map" tab on the bottom of the screen or WaterLink. Less than 100% indicates: (1) additional source capacity is needed, and Source deficit indicates that: (1) additional source capacity is needed, Mona Capacity 2025 Page 1 of 2 9/11/2025 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 515,642 gal Existing Storage Capacity 1,600,000 gal Storage Capacity Deficit None gal Required Fire Storage 60,000 gal Not Applicable Existing % of Total Req'd 310.3% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of ERCs 60 0 30 0 0.00 0.0 20 0 10 0 0.00 0.0 5 0 2.5 0 0.00 0.0 N/A 100 N/A 50 0.13 0.0 Number of people per camp site Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 7 3.5 8.8 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)840 4.1 Projected ERCs Calculation (optional)WS001 Clover Spring 240 Total Projected ERCs 0 WS002 Well #1 600 Existing Residential Connections 0 Obligated Future ERCs (enter below)0 Maximum ERCs (assuming indoor use only)1512 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)1,600,000 ST001 250K Tank 250,000 ST003 350 K Tank 350,000 ST004 1MG Tank 1,000,000 Notes" tab on the bottom of the screen.) RV Park Facility Type Modern Recreation Camp Semi-Developed Camp w/ flush toilets Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely to fire storage? Autolink to 4.3 "Total Existing Storage Capcity" cell below. If applicable, enter number of people per camp site here. Storage deficit indicates that: (1) additional storage volume is needed, and (2) storage deficiency should be assessed. Cell I8 ("Number of residential connections") on Page 1 to calculate PROJECTED demand & req'ts (including both existing & future connections). pressure tanks shall NOT be considered effective storage volume for (1) community systems, or (2) NTNC with significant demand UNLESS an exception has been granted. Autolink to 2 "Total Storage" cell above. number in cell I8 or cell I9 on Page 1. If NO, answer one of question set 2.01 to 2.05 in ESS.If YES, answer one of question set 2.06 to 2.10 in ESS. Less than 100% indicates: (1) additional storage capacity is needed, and (2) storage deficiency should be assessed. Mona Capacity 2025 Page 2 of 2 9/11/2025