Loading...
HomeMy WebLinkAboutDRC-2025-002697 CLIVE SITE LETTER OF TRANSMITTAL DATE: 8/18/2025 ATTN: LLRW CC; Karen Kirkwood Treesa Parker RE: Transmittal 2025-049 Description of Documents Transmitted Qty See attached list for updates to Mixed Waste Disposal. CL-MD-PR-211 Rev 9, Mixed Waste Site Inspections 1 ------------------------------------------------------------------------------------------------------------ Please replace your current procedure revisions with the documents within this Transmittal. You are not required to sign any documents to verify receipt of this distribution. However, you should make every effort to ensure that your copy of the License is current. FROM: EnergySolutions Document Control Clive Facility Electronic documents, once printed, are uncontrolled and may become outdated. Refer to the Intranet or the Document Control authority for the correct revision. CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Authored By: Brett Davis, Mixed Waste Treatment Supervisor Date Reviewed By: Steve Gurr, Environmental Engineer Date Approved By Thomas A. Brown, Radiation Safety Officer (RSO) Date Approved By Brennon Dick, Operations Manager Date Non-Proprietary New Proprietary Title Change Restricted Information Revision Safeguards Information Rewrite Sensitive Security Information Cancellation CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 2 of 27 Table of Contents 1 PURPOSE AND SCOPE ........................................................................................................ 3 1.1 Purpose........................................................................................................................... 3 1.2 Scope............................................................................................................................... 3 2 REFERENCES ....................................................................................................................... 3 3 GENERAL .............................................................................................................................. 3 3.1 Definitions ...................................................................................................................... 3 3.2 Responsibilities .............................................................................................................. 3 3.3 Precautions and Limitations ........................................................................................ 4 3.4 Document Control and Records .................................................................................. 4 4 REQUIREMENTS AND GUIDANCE .................................................................................. 5 5 ATTACHMENTS AND FORMS......................................................................................... 10 CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 PAGE 3 OF 27 1 PURPOSE AND SCOPE 1.1 Purpose The following procedure outlines the site inspection requirements in the State- issued Part B Permit, and Ground Water Quality Discharge Permit. 1.2 Scope This procedure addresses items that shall be inspected, the requirements for resolving any problems found during inspections, and the required documentation of Permit required inspections at the Mixed Waste Facility. 2 REFERENCES 2.1 ES-AD-PR-008, Condition Reports 2.2 Groundwater Quality Discharge Permit UGW450005, Appendix J, BAT Performance Monitoring Plan 2.3 State-issued Part B Permit Attachment II-3, Site Inspection Plan 2.4 CL-EN-PR-011, Clive Engineering Field Inspections 3 GENERAL 3.1 Definitions 3.1.1 Acceptable - Items that meet the stated criteria on the inspection forms. 3.1.2 Unacceptable - Items that do not meet the criteria on the inspection form, including: Problems posing an immediate threat to human health or the environment. 3.1.3 Notable Items – Items which do not meet the definition of Unacceptable but could lead to a future noncompliance situation if left unchecked and/or unattended. 3.1.4 Mixed Waste Evaporation Pond- Pond located in the southwest area of the Mixed Waste Facility. Designed to collect liquid drainage from the storage areas inside the restricted of the Mixed Waste Facility. Not approved for management of Leachate. This pond does not contain hazardous waste and is regulated by Reference 2.2. 3.1.5 Mixed Waste Surface Impoundment (MWSI)- The impoundment is in the northeast corner of Mixed Waste designed to contain leachate. 3.2 Responsibilities 3.2.1 The Operations Manager or designee is responsible for reviewing completed inspection forms and ensuring that corrective actions are identified for unacceptable items. 3.2.2 Qualified RCRA & BAT Inspectors are responsible for completing Permit required daily, weekly, and monthly inspections. 3.2.3 The Groundwater Program Manager is responsible for certifying CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 4 of 27 Groundwater Monitoring Equipment and Wells annual inspections. 3.2.4 The Manager, Compliance and Permitting is responsible for regulatory notifications required within this procedure. 3.2.5 The Environmental Engineer is responsible for ensuring the sampling requirements of the MW Surface Impoundment are completed. 3.2.6 The QA Department is responsible for reviewing and transmitting completed inspections to Document Control. 3.2.7 The Document Control Department is responsible for filing completed inspection forms in the operating record. 3.3 Precautions and Limitations 3.3.1 Personnel shall follow the requirements of the applicable Radiation Work Permit while performing work inside the Restricted Area. 3.3.2 Daily inspections are required any day that work is performed in the Mixed Waste Facility. Days that there’s no activity (e.g., regularly scheduled days off, weekends, or holidays) no inspection form is required. 3.3.3 Weekly inspection is required once per calendar week. 3.3.4 Monthly inspection is required once per calendar month. It is recommended that monthly inspections be conducted at least three weeks apart. 3.3.5 Annual inspection is required once per calendar year and at least four months later than the inspection for the previous calendar year. 3.3.6 If an inspection is not required for that day for a given area, line through the inspection page, write “N/A” or “No Activity” (or similar), then initial and date the line. 3.3.7 The State-issued Part B Permit inspections shall only be performed by those individuals who are RCRA & BAT Inspector qualified in accordance with site procedures. 3.3.8 The Monthly Groundwater Equipment Inspections identified in the Site Inspection Plan, are performed by the Groundwater Department and are not included in this procedure. 3.3.9 If an item is identified during an inspection that cannot be immediately corrected (i.e., within one working day), site management will be notified (preferably in writing) to ensure that any required notifications can be made. Document this notification on the inspection form. 3.3.10 Implement the Contingency Plan in the event of a spill, fire or explosion. 3.3.11 Employees shall keep off the pond liners. If at any time access to the liner becomes necessary, a buddy system will be used, and a life vest with rescue rope worn. 3.4 Document Control and Records CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 5 of 27 3.4.1 Within 60 days of the final review date, the original inspections shall be transmitted to Document Control for inclusion into the operating record. 3.4.2 The analytical results from the MW Surface Impoundment required in Condition 4.1.5.5.1 shall be transmitted to document control within 60 days of receipt. 4 REQUIREMENTS AND GUIDANCE 4.1 Compliance 4.1.1 Daily inspections of the Mixed Waste Evaporation Pond are completed as required by Reference 2.2. All other inspections are completed as required by Reference 2.3. 4.1.2 Except as noted below, daily inspections shall be recorded on CL-MD-PR- 211-F1 and conducted for the following areas: 4.1.2.1 The Mixed Waste Evaporation Pond inspection recorded on forms CL-MD-PR-211 F6 and CL-MD-PR-211 F7. This daily inspection is required on days when off-site shipments are received into the Mixed Waste Facility. 4.1.2.2 General Facility Inspection. This daily inspection is required on days when off-site shipments are received into the Mixed Waste Facility. 4.1.2.3 Leachate Collection. This daily inspection is required on days when waste is transferred to, from, or within disposal facility areas. Note: During partial closure operations, leachate inspections need only be made bi-weekly. 4.1.2.4 Decontamination Tank System Operation. This daily inspection is required: 4.1.2.4.1 On days when waste is transferred to, from, or within the Decontamination Tanks. 4.1.2.4.2 On days when decontamination activities involving these tanks are conducted. 4.1.2.5 Treatment Facility Tank System Operation. This daily inspection is required: 4.1.2.5.1 On days when waste is transferred to, from, or within the Treatment Facility tanks. 4.1.2.5.2 On days when waste management activities are conducted within the Mixed Waste Treatment Building. 4.1.2.6 Treatment Building Baghouse System: Waste management activities which involve the management of waste in units, including miscellaneous units, shall not be performed unless the CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 6 of 27 HVAC system is operating. Operations of the HVAC system include operation of the baghouse and HEPA filtration system. 4.1.2.7 Operations Building Baghouse System: Waste management activities which involve the management of waste in units, including miscellaneous units, shall not be performed unless the HVAC system is operating and a negative pressure is attained within the operations bay. Operations of the HVAC system includes: operation of the baghouse, the HEPA filtration system, the organic carbon filtration system. The carbon filters shall be replaced every two years in baghouse 940-BH-003. An expiration date for the carbon filters shall be labeled on that baghouse. Filter change outs shall be documented in the notes on the inspection form. 4.1.2.8 Baghouse filter differential pressure for all baghouses shall not be lower than 0.1 inH2O, or higher than 6.0 inH2O when treatment operations are in progress. Note: If the differential pressure exceeds 6.0 inH2O, the collection container below the baghouse shall be replaced with a larger container. The replacement container shall be a minimum of 1.0 yd3 to adequately contain the volume of material on the bags. The larger contain will remain in-place throughout the purge process. Once the levels fall below 6.0 inH2O, and the condition that caused the excessive build-up are corrected, work can resume. 4.1.2.9 Mixed Waste Operations Building process area. This daily inspection is required on days when waste management activities are conducted in this building. 4.1.2.10 Thermal Desorption System. This daily inspection is required: 4.1.2.10.1 On days when waste is transferred to, from, or within the thermal desorption system. 4.1.2.10.2 On days when waste is processed within the thermal desorption system. 4.1.2.11 MW Surface Impoundment (recorded on CL-MD-PR-211- F4 and CL-MD-PR-211-F5). This daily inspection is required on days when leachate is transferred to, from, or within the Surface Impoundment. 4.1.2.12 Secondary containment vaults shall be inspected for leaks, CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 7 of 27 corrosion, cracks, and deterioration. 4.1.3 Weekly inspections shall be recorded on CL-MD-PR-211-F2 and conducted for the following areas: 4.1.3.1 Perimeter and General Facility 4.1.3.2 Container Storage 4.1.3.3 MW Surface Impoundment 4.1.4 Monthly inspections shall be recorded on CL-MD-PR-211-F3 and conducted for the following area: 4.1.4.1 Safety and Emergency Equipment 4.1.5 Annual inspections are recorded in report format and conducted areas as described below: 4.1.5.1 Annual Tank Condition Assessment 4.1.5.1.1 This assessment is to be conducted for each permitted tank. 4.1.5.1.2 This assessment is to be performed by an independent Utah-registered professional engineer. 4.1.5.1.3 Empty the tank and document that it has been emptied. 4.1.5.1.4 Inspect internal surface area for leaks and corrosion, erosion, cracks, and pitting. 4.1.5.1.5 Assess the wall thickness using an appropriate device. The independent Utah- registered professional engineer will make a determination in the report that sufficient wall thickness remains. 4.1.5.2 Annual Fire Suppression System 4.1.5.2.1 This inspection is to be performed by an independent certified or qualified fire system inspector. 4.1.5.2.2 Check the pump flow for adequacy in accordance with applicable building codes. 4.1.5.2.3 Check gauges for proper function and accuracy. 4.1.5.3 Groundwater Monitoring Equipment 4.1.5.3.1 This inspection is to be certified by the Groundwater Program Manager. 4.1.5.3.2 Check dedicated pumps for general integrity. CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 8 of 27 4.1.5.4 Groundwater Monitoring Wells 4.1.5.4.1 This inspection is to be certified by the Groundwater Program Manager. 4.1.5.4.2 Visually inspect groundwater monitoring wells and aprons for cracks, corrosion, damage and degradation. 4.1.5.4.3 Visually inspect groundwater monitoring wells and aprons for frost heave, vandalism, and structural integrity problems. 4.1.5.4.4 Visually and manually inspect wells for security and for the presence and integrity of locks. 4.1.5.5 Annual MW Surface Impoundment Assessment. 4.1.5.5.1 Collect a sample and analyze for the following radiological parameters: ▪ Alpha Emitters: Np-237, Sr-90, Th-230, Th-232, U-233, U-234, U-235, U-236, and U-238. ▪ Beta/Gamma Emitters: C-14, I-129, Tc-99, and H-3. ▪ Combined: Ra-226 + Ra-228. 4.1.5.5.2 The analytical data shall be reviewed by the Environmental Engineer prior to transmitting to document control. 4.1.5.5.3 Check the winding resistance and insulation resistance from the submersible pump, in accordance with Reference 2.4. 4.1.6 The following requirements for problem resolution shall be followed for unacceptable items identified during inspections. Note: Items on CL-MD-PR-211-F1 that are marked with an asterisk (*) are items that are not listed in Reference 2.2. If these items cannot be fixed immediately, sections 4.1.6.2., 4.1.6.4., and 4.1.6.5 shall be followed. Section 4.1.6.3. is not required for these items. 4.1.6.1 Problems that pose an imminent threat to human health or the environment shall be corrected immediately. Notify the Operations Manager or designee immediately upon discovery. 4.1.6.2 If an identified problem is corrected within 72 hours of identification, record how and when (date/time) the problem was corrected in the “Immediate Corrective Action” column. CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 9 of 27 4.1.6.3 If an identified problem cannot be corrected within 72 hours, the Manager, Compliance and Licensing or designee will be informed, and regulatory notification made prior to the end of the 72-hour period. The notification will include a proposed time schedule for correcting the problem. 4.1.6.4 If an identified problem cannot be corrected within one week a Condition Report shall be issued in accordance with Reference 2.1. 4.1.6.5 The Operations Manager will ensure that long term problems are properly addressed and documented in the “Long Term Corrective Action” column, along with “Initials/Date.” Note: Reference the Condition Report number (if needed) in the “Long Term Corrective Action Column” to provide traceability between the deficiency and the tracking mechanism. 4.1.6.6 A comprehensive list of notable items shall be maintained and available for review on site. This comprehensive list shall be documented on the individual daily, weekly and monthly inspection forms. 4.2 Inspection Process 4.2.1 Inspection Completion 4.2.1.1 The inspector shall complete the date and time of inspection on the top of each form. 4.2.1.2 The inspector shall inspect the facility for each of the items listed on the inspection form. 4.2.1.3 For each item, the inspector shall document whether the item is acceptable. Items that pass the criteria listed in the “Item Description” column are acceptable. Items that fail the criteria or may harm people or the environment are not acceptable. 4.2.1.4 For unacceptable and notable items, the inspector shall record the problem in the “Observations” column. Note: The inspector may make notes of items found to be in accordance with requirements. Documentation of such items is not required. 4.2.1.5 Inspectors should include enough detailed information on the inspection form regarding identified issues and observations to clearly identify the nature and location of the issue/observation. 4.2.1.6 Once the inspection is complete, the inspector shall print and sign the last page of the inspection packet. 4.2.1.7 The completed inspection packet is reviewed by the Operations CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 10 of 27 Manager and Quality Assurance personnel. This review is documented by initialing and dating the bottom of the final page of the inspection packet. 4.2.2 Mixed Waste Evaporation Pond and Mixed Waste Surface Impoundment Inspection Completion 4.2.2.1 The Mixed Waste Surface Impoundment Daily Inspection uses form CL-MD-PR-211-F4. 4.2.2.1.1 Once each week, an average daily leakage volume from the Mixed Waste Surface Impoundment will be calculated using form CL-MD-PR-211-F5. 4.2.2.2 The Mixed Waste Evaporation Pond Daily Inspections uses form CL-MD-PR-211 F6. 4.2.2.2.1 Once each week, an average daily leakage volume from the Mixed Waste Evaporation Pond will be calculated using form CL-MD- PR-211 F7. 5 ATTACHMENTS AND FORMS 5.1 CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form - Example 5.2 CL-MD-PR-211 F2, Mixed Waste Weekly Inspection Form - Example 5.3 CL-MD-PR-211 F3, Mixed Waste Monthly Inspection Form – Example 5.4 CL-MD-PR-211 F4, Mixed Waste Surface Impoundment Form - Example 5.5 CL-MD-PR-211 F5, Mixed Waste Surface Impoundment Leak Detection System Volume Weekly Calculation Form – Example 5.6 CL-MD-PR-211 F6, Mixed Waste Evaporation Pond Daily Inspection Form - Example 5.7 CL-MD-PR-211 F7, Mixed Waste Evaporation Pond Leak Detection System Volume Weekly Calculation Form - Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 11 of 27 Attachment 5.1- CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form, Page 1 – Example . CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 12 of 27 Attachment 5.1- CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form, Page 2 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 13 of 27 Attachment 5.1- CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form, Page 3 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 14 of 27 Attachment 5.1- CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form, Page 4 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 15 of 27 Attachment 5.1- CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form, Page 5– Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 16 of 27 Attachment 5.1- CL-MD-PR-211 F1, Mixed Waste Daily Inspection Form, Page 6 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 17 of 27 Attachment 5.2 - CL-MD-PR-211 F2, Mixed Waste Weekly Inspection Form Page 1 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 18 of 27 Attachment 5.2 - CL-MD-PR-211 F2, Mixed Waste Weekly Inspection Form Page 2 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 19 of 27 Attachment 5.2 - CL-MD-PR-211 F2, Mixed Waste Weekly Inspection Form Page 3 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 20 of 27 Attachment 5.2 - CL-MD-PR-211 F2, Mixed Waste Weekly Inspection Form Page 4 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 21 of 27 Attachment 5.3 - CL-MD-PR-211 F3, Mixed Waste Monthly Inspection Form, Page 1– Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 22 of 27 Attachment 5.3 - CL-MD-PR-211 F3, Mixed Waste Monthly Inspection Form, Page 2 – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 23 of 27 Attachment 5.4 – CL-MD-PR-211 F4, Mixed Waste Surface Impoundment Inspection Form – Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 24 of 27 Attachment 5.5 – CL-MD-PR-211 F5, Mixed Waste Surface Impoundment Leak Detection System Volume Weekly Calculation Form - Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 25 of 27 Attachment 5.6 – CL-MD-PR-211 F6, Mixed Waste Evaporation Pond Daily Inspection Form - Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 26 of 27 Attachment 5.7 – CL-MD-PR-211 F7, Mixed Waste Evaporation Pond Leak Detection System Volume Weekly Calculation Form - Example CL-MD-PR-211 Mixed Waste: Site Inspections Revision 9 Non-Proprietary Page 27 of 27 DOCUMENT SUMMARY FORM