Loading...
HomeMy WebLinkAboutDERR-2025-006050Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard 850 South 300 West Salt Lake City, Salt Lake County,Utah May 2, 2016 Terracon Project No. 61167208 Prepared for: Salt Lake City Corporation Salt Lake City, Utah Prepared by: Terracon Consultants, Inc. Midvale, Utah Terracon Consultants Inc. 6949 S High Tech Dr Ste 100 Midvale, UT 84047-3707 P 801-545-8500 F 801-545-8600 terracon.com May 2, 2016 Salt Lake City Corporation 451 South State Street, Room 425 Salt Lake City, Utah 84111 Attn: Mr. Todd Reeder P: (801) 535-7115 E: Todd.Reeder@slcgov.com Re: Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard 850 South 300 West Salt Lake City, Salt Lake County, Utah Terracon Project No. 61167208 Dear Mr. Reeder: Terracon Consultants, Inc. (Terracon) is pleased to submit the enclosed Phase I Environmental Site Assessment (ESA) report for the above-referenced site. This assessment was performed in accordance with Terracon Proposal No. P61167208, dated March 1, 2016. We appreciate the opportunity to be of service to you on this project. In addition to Phase I services, our professionals provide geotechnical, environmental, construction materials, and facilities services on a wide variety of projects locally, regionally and nationally. For more detailed information on all of Terracon’s services, please visit our website at www.terracon.com. If there are any questions regarding this report or if we may be of further assistance, please do not hesitate to contact us. Sincerely, Terracon Consultants, Inc. Nancy Saunders Benjamin B. Bowers Project Environmental Scientist Environmental Department Manager Attachments TABLE OF CONTENTS Page No. EXECUTIVE SUMMARY .......................................................................................................................... i Findings ....................................................................................................................................... i Opinions and Conclusions ........................................................................................................... iii Significant Data Gaps ................................................................................................................. iii Recommendations ...................................................................................................................... iii 1.0 INTRODUCTION ........................................................................................................................ 1 1.1 Site Description .............................................................................................................. 1 1.2 Scope of Services........................................................................................................... 1 1.3 Standard of Care ............................................................................................................ 1 1.4 Additional Scope Limitations, ASTM Deviations and Data Gaps ...................................... 2 1.5 Reliance ......................................................................................................................... 3 1.6 Client Provided Information ............................................................................................. 3 2.0 PHYSICAL SETTING ................................................................................................................. 4 3.0 HISTORICAL USE INFORMATION ............................................................................................ 5 3.1 Historical Topographic Maps, Aerial Photographs, Sanborn Maps................................... 5 3.2 Site Ownership ............................................................................................................... 7 3.3 Historical City Directories ................................................................................................ 7 3.4 Title Search .................................................................................................................... 8 3.5 Environmental Liens and Activity and Use Limitations ..................................................... 8 3.6 Interviews Regarding Current and Historical Site Uses.................................................... 8 3.7 Prior Report Review ....................................................................................................... 8 3.8 Historical Use Information Summary ............................................................................. 10 4.0 RECORDS REVIEW ................................................................................................................. 10 4.1 Federal and State/Tribal Databases .............................................................................. 11 4.2 Local Agency Inquiries .................................................................................................. 16 5.0 SITE RECONNAISSANCE ....................................................................................................... 16 5.1 General Site Information ............................................................................................... 16 5.2 Overview of Current Site Occupants ............................................................................. 17 5.3 Overview of Current Site Operations ............................................................................. 17 5.4 Site Observations ......................................................................................................... 18 6.0 ADJOINING PROPERTY RECONNAISSANCE ........................................................................ 22 7.0 ADDITIONAL SERVICES ......................................................................................................... 23 8.0 DECLARATION ........................................................................................................................ 24 TABLE OF CONTENTS (continued) APPENDICES APPENDIX A Exhibit 1 - Topographic Map, Exhibit 2 - Site Diagram, Exhibit 3 –Adjoining Properties APPENDIX B Site Photographs APPENDIX C Historical Documentation and User Questionnaire APPENDIX D Environmental Database Information APPENDIX E Credentials APPENDIX F Description of Terms and Acronyms Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable i EXECUTIVE SUMMARY This Phase I Environmental Site Assessment (ESA) was performed in accordance with Terracon Proposal No. P61167208, dated March 1, 2016, and was conducted consistent with the procedures included in ASTM E1527-13,Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. The ESA was conducted under the supervision or responsible charge of Nancy Saunders, Environmental Professional. Ms. Saunders performed the site reconnaissance on April 14, 2016. Findings A summary of findings is provided below. It should be recognized that details were not included or fully developed in this section, and the report must be read in its entirety for a comprehensive understanding of the items contained herein. Site Description and Use The majority of the site is used predominantly for storage by various city departments. Along the south section of the block, occupants include the Salt Lake City Police Department, K9 Unit, who use a portion of the building for training in the evenings, and the parking enforcement department for storage of parking meters and parts. The covered storage sheds along the west side of the block are essentially vacant. In the northwest corner of the site, the landscape services group stores landscaping materials, and there are two plastic aboveground storage tanks for mixing salt water for pre-wetting of roads in the open storage area. Farther to the north is an open, fenced storage area leased to Kentlands Institute, a non-profit organization, for storage of containers that are used seasonally as micro retail spaces. The northern portion of the block is unoccupied and consists of office space and one large shop building with a wash area in front. Along the east side of the block are shop and office spaces. The shop areas are used by the Salt Lake City Fire Department for storage and cleaning of vehicles (no service is conducted); and by the Salt Lake City Police Department for storage of miscellaneous items, such as tires, bicycles, and trailers. The office spaces are all currently vacant and many are dilapidated and unfit for occupancy. Historical Information The site has been used for industrial purposes since at least 1911 with the operation of a coal yard, an asphalt plant, vehicle repair shops, and fleet fueling and repair. In addition, railroad spurs crossed the northern portion of the site. Suspect uses at the site have been identified as light and heavy vehicle/equipment maintenance, engineering materials testing, street painting and stripping, sign painting, hazardous materials storage, automotive painting, vehicle washing, vehicle fueling, and waste oil collection and storage. Two subsurface investigations conducted at the site documented petroleum hydrocarbons, SVOCs, lead, and arsenic in soils at concentrations that exceeded a screening level at the site. The results of groundwater sampling Phase I Environmental Site Assessment Salt Lake City Fleet Yard Block ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable ii as part of the two sampling events reported dissolved petroleum hydrocarbons, tetrachloroethene (PCE), SVOCs, and total metals at concentrations that exceeded a screening level in groundwater at the site. Historical industrial activities represent an REC to the site. Records Review The site is listed on the UST, LUST, RCRA, and NPDES databases. While all USTs at the site have been removed, there have been two release incidents that resulted in the two listings on the LUST database. Little information was available regarding the closure and release at the site of the waste oil USTs. The lack of sample data and subsequent assessment during the Brownfields assessment represents an REC. The second LUST has undergone remediation but is currently under investigation to determine the down-gradient extent of the groundwater plume that resulted from the release. The presence of an uncharacterized groundwater plume migrating toward the site boundary represents an REC. The various RCRA listings do not appear to represent RECs, although they do indicate that a variety of hazardous materials and universal wastes have been handled at the site. The NPDES listing refers to a storm water discharge permit with the State of Utah. No violations were noted in the regulatory database report. The west-adjoining property, addressed at 370 W 900 S, is listed as a RCRA No Longer Regulated facility. Although regulators have not identified issues associated with the permit (only a minor violation was noted in the database), little information was available regarding this operation. The numerous hazardous materials and universal wastes handled at this facility presents a potential for impacts to the site. As such, this west-adjoining facility represents an REC to the site. A north-adjoining property, Salt Lake Collision Repair, addressed at 362 W 800 South, is listed as a RCRA facility. Although it is no longer in operation, it was previously permitted to handle spent solvents. Due to its proximity and upgradient location, it represents a REC to the site. Site Reconnaissance Several suspect features were observed during the site reconnaissance. There are trench drains in the shop buildings on the east and north sides of the block, two likely oil/water separators and a sump on the north side of the property, and a suspect trench drain/sump feature in the southwest corner of the block. These features were likely installed at the time the facility was developed for fleet maintenance in the 1970s. Although sampling at the site has indicated there are no widespread impacts in either soils or groundwater, these features do not appear to have been specifically assessed and may have resulted in localized areas of contamination. They represent RECs to the site. Adjoining Properties The site is adjoined to the north by several suspect businesses, specifically, two automotive repair shops and an auto body shop. These types of businesses can be associated with releases of petroleum hydrocarbons and VOCs. Sampling at the site for the Brownfields assessment included a boring placed at the northeast corner of the site, up-gradient of suspect Phase I Environmental Site Assessment Salt Lake City Fleet Yard Block ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable iii sources identified at the property, which reported PCE in groundwater. The up-gradient adjoining automotive shops may be the source of this contaminant in groundwater at the site and are considered an REC to the site. The remaining adjoining properties do not appear to be suspect properties or are located cross- or down-gradient of the site. Additional Services Per the agreed scope of services specified in the proposal, additional services (e.g. asbestos sampling, lead-based paint sampling, wetlands evaluation, lead in drinking water testing, radon testing, vapor encroachment screening, etc.) were not conducted. Opinions and Conclusions We have performed a Phase I ESA consistent with the procedures included in ASTM Practice E 1527-13 at 850 South 300 West, Salt Lake City, Salt Lake County, Utah, the site. The following Recognized Environmental Conditions (RECs) or Controlled RECs (CREC) were identified in connection with the site: n Historical Industrial Uses:The site has been used for industrial purposes since at least 1911, resulting in known impacts (contaminant concentrations in the subsurface above screening levels have been documented in two previous sampling events). There are two LUST incidents at the site, one of which is still open, and there is a potential for impacts from unassessed suspect features such as floor drains, sumps and oil/water separators. n Potential Groundwater Impacts from North-adjoining Automotive Businesses: The chlorinated solvent, PCE, was reported in groundwater from a sample collected at the northern property boundary, suggesting off-site impacts. n Potential Impacts from West-adjoining RCRA Facility:A former metals scrap yard and barrel supplier historically occupied the west-adjoining property. If regulated materials were poorly handled at this facility, contaminants may have migrated to groundwater underlying the site. Significant Data Gaps Historical records provided contradictory information about a historical gasoline tank used at the property in the 1960s and 1970s. It is not clear if the tank was an UST or an AST. The lack of definitive records describing this tank represents a data gap which could affect the conclusions of this Phase I ESA. Recommendations n Additional Investigation:Terracon recommends conducting additional investigation to evaluate subsurface conditions associated with the identified RECs and significant data gap. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 1 1.0 INTRODUCTION 1.1 Site Description Site Name Salt Lake City Fleet Yard Block Site Location/Address 850 South 300 West, Salt Lake City, County, Utah Land Area Approximately 8.5 acres Site Improvements The site is improved with several shop and maintenance buildings, offices, and fenced open and covered storage. The site location is depicted on Exhibit 1 of Appendix A, which was reproduced from a portion of the USGS 7.5-minute series topographic map. A diagram of the site is included as Exhibit 2 of Appendix A and a site map showing adjoining properties is included as Exhibit 3 of Appendix A. Acronyms and terms used in this report are described in Appendix F. 1.2 Scope of Services This Phase I ESA was performed in accordance with Terracon Proposal No. P61167208, dated March 1, 2016, and was conducted consistent with the procedures included in ASTM E1527-13, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. The purpose of this ESA was to assist the client in developing information to identify RECs in connection with the site as reflected by the scope of this report. This purpose was undertaken through user-provided information, a regulatory database review, historical and physical records review, interviews, including local government inquiries, as applicable, and a visual noninvasive reconnaissance of the site and adjoining properties. Limitations, ASTM deviations, and significant data gaps (if identified) are noted in the applicable sections of the report. ASTM E1527-13 contains a new definition of "migrate/migration," which refers to “the movement of hazardous substances or petroleum products in any form, including, for example, solid and liquid at the surface or subsurface, and vapor in the subsurface.” By including this explicit reference to migration in ASTM E1527-13, the standard clarifies that the potential for vapor migration should be addressed as part of a Phase I ESA and was considered by Terracon in evaluation of RECs associated with the site. 1.3 Standard of Care This ESA was performed in accordance with generally accepted practices of this profession, undertaken in similar studies at the same time and in the same geographical area. We have endeavored to meet this standard of care, but may be limited by conditions encountered during performance, a client-driven scope of work, or inability to review information not received by the report date. Where appropriate, these limitations are discussed in the text of the report, and an evaluation of their significance with respect to our findings has been conducted. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 2 Phase I ESAs, such as the one performed at this site, are of limited scope, are noninvasive, and cannot eliminate the potential that hazardous, toxic, or petroleum substances are present or have been released at the site beyond what is identified by the limited scope of this ESA. In conducting the limited scope of services described herein, certain sources of information and public records were not reviewed. It should be recognized that environmental concerns may be documented in public records that were not reviewed. No ESA can wholly eliminate uncertainty regarding the potential for RECs in connection with a property. Performance of this practice is intended to reduce, but not eliminate, uncertainty regarding the potential for RECs. No warranties, express or implied, are intended or made. The limitations herein must be considered when the user of this report formulates opinions as to risks associated with the site or otherwise uses the report for any other purpose. These risks may be further evaluated – but not eliminated – through additional research or assessment. We will, upon request, advise you of additional research or assessment options that may be available and associated costs. 1.4 Additional Scope Limitations, ASTM Deviations and Data Gaps Based upon the agreed-on scope of services, this ESA did not include subsurface or other invasive assessments, vapor intrusion assessments or indoor air quality assessments (i.e. evaluation of the presence of vapors within a building structure), business environmental risk evaluations, or other services not particularly identified and discussed herein. Credentials of the company (Statement of Qualifications) have not been included in this report but are available upon request. Pertinent documents are referred to in the text of this report, and a separate reference section has not been included. Reasonable attempts were made to obtain information within the scope and time constraints set forth by the client; however, in some instances, information requested is not, or was not, received by the issuance date of the report. Information obtained for this ESA was received from several sources that we believe to be reliable; nonetheless, the authenticity or reliability of these sources cannot and is not warranted hereunder. This ESA was further limited by the following: Historical records provided contradictory information about a historical gasoline tank used at the property in the 1960s and 1970s. It is not clear if the tank was an UST or an AST. The lack of definitive records describing this tank represents a significant data gap that could affect the conclusions of this Phase I ESA. As a result, this data gap is considered a REC to the site. An evaluation of the significance of limitations and missing information with respect to our findings has been conducted, and where appropriate, significant data gaps are identified and discussed in the text of the report. However, it should be recognized that an evaluation of significant data gaps is based on the information available at the time of report issuance, and an evaluation of information received after the report issuance date may result in an alteration of our conclusions, recommendations, or opinions. We have no obligation to provide information obtained or discovered by us after the issuance date of the report, or to perform any additional services, regardless of whether the information would affect any conclusions, recommendations, Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 3 or opinions in the report. This disclaimer specifically applies to any information that has not been provided by the client. This report represents our service to you as of the report date and constitutes our final document; its text may not be altered after final issuance. Findings in this report are based upon the site’s current utilization, information derived from the most recent reconnaissance and from other activities described herein; such information is subject to change. Certain indicators of the presence of hazardous substances or petroleum products may have been latent, inaccessible, unobservable, or not present during the most recent reconnaissance and may subsequently become observable (such as after site renovation or development). Further, these services are not to be construed as legal interpretation or advice. 1.5 Reliance This ESA report is prepared for the exclusive use and reliance of Salt Lake City Corporation . Use or reliance by any other party is prohibited without the written authorization of Salt Lake City Corporation and Terracon Consultants, Inc. (Terracon). Reliance on the ESA by the client and all authorized parties will be subject to the terms, conditions and limitations stated in the proposal, ESA report, and Terracon’s Agreement. The limitation of liability defined in the Agreement is the aggregate limit of Terracon’s liability to the client and all relying parties. Continued viability of this report is subject to ASTM E1527-13 Sections 4.6 and 4.8. If the ESA will be used by a different user (third party) than the user for whom the ESA was originally prepared, the third party must also satisfy the user’s responsibilities in Section 6 of ASTM E1527-13. 1.6 Client Provided Information Prior to the site visit, Mr. Todd Reeder, client’s representative, was asked to provide the following user questionnaire information as described in ASTM E1527-13 Section 6. Client Questionnaire Responses Client Questionnaire Item Client Did Not Respond Client’s Response Yes No Specialized Knowledge or Experience that is material to a REC in connection with the site.X Actual Knowledge of Environmental Liens or Activity Use Limitations (AULs) that may encumber the site.X Actual Knowledge of a Lower Purchase Price because X Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 4 Client Questionnaire Item Client Did Not Respond Client’s Response Yes No contamination is known or believed to be present at the site. Commonly Known or Reasonably Ascertainable Information that is material to a REC in connection with the site.X Obvious Indicators of Contamination at the site.X The client indicated there is ongoing remediation of an onsite LUST site which represents a REC. 2.0 PHYSICAL SETTING Physical Setting Physical Setting Information Source Topography (Refer to Appendix A for an excerpt of the Topographic Map) Site Elevation 4,230 feet (NGVD) USGS Topographic Map,Salt Lake City North,1998 Surface Runoff/ Topographic Gradient The site is essentially flat with a very gentle gradient to the southwest Closest Surface Water Jordan River, approximately one mile west of the site Soil Characteristics Soil Type Urban Land (UL) Salt Lake County, UT Web Soil Survey Report issued 4/30/16DescriptionUrban land – fill material Geology/Hydrogeology Formation Qpc: Silt and Clay Deposits of Regressive Phase of Lake Bonneville Utah Geological Survey Online MapDescriptionSandy clay to clayey silt and silty clay. Massive to thinly bedded Estimated Depth to First Occurrence of Groundwater Approximately 8 feet On-site subsurface investigations (referenced in Section 3.7) *Hydrogeological Gradient South – On-site subsurface investigations (referenced in Section 3.7) * The groundwater flow direction and the depth to shallow, unconfined groundwater, if present, would likely vary depending upon seasonal variations in rainfall and other hydrogeological features. Without the benefit of on-site groundwater monitoring wells surveyed to a datum, groundwater depth and flow direction beneath the site cannot be directly ascertained. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 5 3.0 HISTORICAL USE INFORMATION Terracon reviewed the following historical sources to develop a history of the previous uses of the site and surrounding area, in order to help identify past uses for RECs. Copies of selected historical documents are included in Appendix C. 3.1 Historical Topographic Maps, Aerial Photographs, Sanborn Maps Readily available historical USGS topographic maps, selected historical aerial photographs (at approximately 10- to 15-year intervals) and historical fire insurance maps produced by the Sanborn Map Company were reviewed to evaluate land development and obtain information concerning the history of development on and near the site. Reviewed historical topographic maps, aerial photographs and Sanborn maps are summarized below. Historical fire insurance maps produced by the Sanborn Map Company were requested from Utah Historical Society and the University of Utah’s Marriott Library to evaluate past uses and relevant characteristics of the site and surrounding properties. Utah Historical Society and the University of Utah Marriot Library provided Sanborn maps as summarized below. n Topographic map: Salt Lake City North, published in 1951 from 1950 aerial photographs (1:24,000) n Aerial photographs: Source: Geo-search: 1937, 1950, 1958, 1962, 1973, 1977, 1981, 1987, 1997, 2006, 2014; scale varies (refer to Appendix C for details). n Aerial photographs: Source: Google Earth: 1993, 2011. n Sanborn Fire Insurance Map(s):1911, 1950, 1951, 1957, and 1969 Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 6 Historical Topographic Maps, Aerial Photographs and Sanborn Maps Direction Description Site A 1911 Sanborn map shows the “Federal Coal Co’s Yards” located on the northern portion of the property with multiple O.S.L.R.R. rail spurs entering the property from the northwest and terminating on the property. Two spurs terminate on the northern portion within the coal yard, and a third spur runs along the east side of the property. The “Lemps Beer Depot” is located on the northwest corner, and the central portion of the property is occupied by “P.J. Moran Contractors Stables and Repair Shops” with a building located in the center of the property. A 1936 property tax card reported a brick structure associated with the coal house and did not identify underground storage tanks. The 1950 and 1951 Sanborn maps show a coal yard, now listed as “Wasatch Coal Co’s Yard” still present on the northern portion of the site. The beer depot on the northwest corner is now occupied by General Mills, Inc., with electric lights and steam heat. The central portion of the site is now occupied by “Salt Lake City Street Dep.” From east to west this includes a building labeled “repair shops” with a woodworking section and a welding shop. Farther west is a small paint shop and a large structure labeled “Machine Shop” and “Garage.” Moving west is an asphalt plant and a gasoline tank. The description of the tank states it is elevated 8 inches on concrete piers and appears to be contained in an enclosure with 4-foot-high concrete walls. The 1951 topographic map shows the site as a shaded area, denoting dense development, crossed by railroad spurs. Several changes are apparent in the 1957 Sanborn map. In the northeast corner of the block are now two dwellings, a drug store, and a lumber store. Farther west is a structure labeled “chem lab.” In the center of the block the Garage and Machine shops are still present. The asphalt plant is no longer indicated on the Sanborn map; however, components of it are visible in the 1958 aerial photograph. The aboveground gasoline tank is still present on the Sanborn map and is also visible in the 1958 aerial photograph. Although not designated on the Sanborn map, the 1958 aerial photo shows a structure in the south-central portion of the site where vehicles appear to be pulling through, consistent with a fuel dispenser island. The 1969 Sanborn map no longer shows a coal yard on the northern portion of the site, and a long narrow equipment shed now occupies the northern property side of the site. The northwest corner of the site is occupied by an aluminum sash manufacturer. The garages / shop buildings currently occupying the east side of the site are present by 1969, as shown on the Sanborn map. By 1971, the large machine shop and garage in the central portion of the site has been removed. The fuel dispenser island appears to be present still. A 1977 aerial photograph shows the site essentially as it is currently configured. Site continued There is substantial vehicle parking throughout the site. By 2011, the site no longer appears to be used for fleet storage. The 2015 aerial photograph shows the fuel island has been removed and a large disturbed area appears in that area of the site. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 7 Direction Description North Across 8th South Street, the 1911 Sanborn map shows the properties as residential, with the exception of a roller mill north of the northwest corner of the site block. By the 1950s, as shown in the Sanborn maps from 1950, 1951, and 1957, several residential properties have been turned to industrial uses, such as refrigeration repair, electrical repair. East On the east side of 3rd West (formerly 2nd West), the properties have been developed for residential use from at least 1911 through 1993, as shown in Sanborn maps and aerial photographs. By 1997 the southwest corner of the east-adjoining block has been developed with an industrial business. South In 1911, the Sanborn map shows 9th Street with a canal on the south side of the street to the south of the site block. All properties are designated as dwellings, with the exception of the southwest corner of the south-adjoining block which is labeled as Consolidated Salt & Refining Company. By the 1950s, as shown in the Sanborn maps from 1950, 1951, and 1957, the properties have remained mostly residential although there is an auto repair shop near the southeast corner of the block. Aerial photographs from 1965 through the 2000s and the 1969 Sanborn map show a mix of residential and light industrial (such as auto repair and lawnmower service) properties. West The southwest corner of the block, adjoining the site to the west, is a scrap metal salvaging business visible in the 1958, 1965, 1971, and 1977 aerial photographs and shown on the 1969 Sanborn map. The salvage yard is no longer visible in the 1980 aerial photograph. The database report indicates the property is occupied by Utah Barrel and Supply Co. in the 1980s. The site has been used for industrial purposes since at least 1911. It has been occupied by a coal yard, an asphalt plant, vehicle repair shops, and fleet fueling and repair operations. In addition, railroad spurs crossed the northern portion of the site. These uses of the site are associated with storage, use, and disposal of potentially hazardous or regulated materials and, as such, represent an REC to the site. In addition, the property at the southwest corner of the block (adjoining the site to the west) was used as a metal scrap yard for approximately 20 years and later as a barrel supplier. There is a potential that metals and chemicals from the scrap operation and chemicals from the barrel supplier have impacted underlying groundwater and those contaminants may have migrated to the site. This west-adjoining property represents an REC to the site. 3.2 Site Ownership Based on a review of information obtained from the Salt Lake County Assessor’s records, the current site owner is Salt Lake City Corporation. 3.3 Historical City Directories Due to the abundance of historical data available through Sanborn Maps, aerial photographs, tax cards, and previous reports, city directories were not reviewed for this Phase I ESA. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 8 3.4 Title Search At the direction of the client, a title search was not included as part of the scope of services. Unless notified otherwise, we assume that the client is evaluating this information outside the scope of this report. 3.5 Environmental Liens and Activity and Use Limitations Environmental lien and activity and use limitation records recorded against the site were not provided by the client. At the direction of the client, performance of a review of these records was not included as part of the scope of services and unless notified otherwise, we assume that the client is evaluating this information outside the scope of this report. While not requested by the client, the Utah Historical Society and the GeoSearch regulatory database report included a review of both Federal and State Engineering Control (EC) and Institutional Control (IC) databases. Based on a review of the database report, the site was not listed on the EC or IC databases. Please note that in addition to these federal and state listings, AULs can be recorded at the county and municipal level that may not be listed in the regulatory database report. Based on its limited nature, this review does not constitute a review of AULs per ASTM E1527-13. 3.6 Interviews Regarding Current and Historical Site Uses The following individuals were interviewed regarding the current and historical use of the site. Interviews Interviewer Interviewee/Phone #Title Date/Time Nancy Saunders Todd Reeder Owner Representative April 14, 2016 Mr. Reeder explained that the site had had an industrial history and was most recently used by the City of Salt Lake for fleet management, including automotive service and fueling activities. A release from an underground storage tank system resulted in subsurface soil and groundwater impacts, which are currently being addressed with oversight from the Utah DEQ. 3.7 Prior Report Review Terracon requested the client provide any previous environmental reports they are aware of for the site. Previous reports were provided by the client to Terracon for review. n Brownfields Environmental Assessment Report, Fleet Management Yard 325 West 800 South, Salt Lake City, Utah Dated: September 23, 2005 Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 9 Prepared by: Millennium Science & Engineering (MSE) For: Salt Lake City Public Services Department MSE conducted an environmental assessment, which included a subsurface investigation, on the property in 2005 as part of the Salt Lake City Gateway Brownfields Pilot Program. The Brownfields Pilot Program was funded by the Environmental Protection Agency (EPA) in an effort to evaluate properties in Salt Lake City for potential environmental conditions. The report discussed previous uses at the site and identified many suspect operations listed as light and heavy vehicle/equipment maintenance, engineering materials testing, street painting and stripping, sign painting, hazardous materials storage, automotive painting, vehicle washing, vehicle fueling, and waste oil collection and storage. The report specified the following potential areas of concern: the fueling station that was in use at the time of the assessment, former asphalt plant locations, a former gasoline tank location, the Sanitation Division garage, heavy vehicle maintenance areas, and the northern vehicle maintenance shop. Based on a review of historical information, MSE conducted a subsurface investigation to evaluate each of these areas. The investigation included the collection of 15 soil samples and 10 groundwater samples across the site. The samples were analyzed for one or more of the following analytes: total metals, volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs), polychlorinated biphenyls (PCBs), and petroleum hydrocarbons. The results of the soil investigation reported petroleum hydrocarbons, SVOCs, lead, and arsenic at concentrations that exceeded a screening level in soils at the site. Screening levels used included Utah DERR Recommended Cleanup Levels (RCLs) for unrestricted land use, DERR Tier 1 Screening Levels, which allow contaminants to remain in the soils but place restrictions on land use, and EPA Risk Based Cleanup Levels for both residential and industrial land use scenarios. The results of the groundwater investigation reported dissolved petroleum hydrocarbons, tetrachloroethene (PCE), SVOCs, and total metals at concentrations that exceeded a screening level in groundwater at the site. Screening levels for groundwater used in the study were EPA tap water screening levels, EPA Drinking Water Maximum Contaminant Levels (MCLS), Utah DERR MCLs, and Utah DERR Tier 1 Screening Levels. An abridged version of the report is included in Appendix C, including a site plan showing sample locations. Locations of samples where results exceeded a screening level are also shown on Exhibit 2, Appendix A. Although not presented in a report, in 2013 Terracon conducted a limited sampling event in the northern portion of the site to further assess impacts identified by MSE and to investigate additional suspect subsurface features. This investigation consisted of advancing and sampling 10 borings for soil and groundwater. The results of soil sampling showed minimal to non- detectable impacts to soils in the northern portion of the site from petroleum hydrocarbons, VOCs, and metals. PAHs were found in soils in the northwestern portion of the site in samples located along the historical railroad spurs and in the area of the former asphalt plants and coal yards. Several PAHs exceeded residential RSLs and one PAH exceeded its industrial RSL. Groundwater was sampled from the ten borings installed during this investigation as well as several of the MSE wells that could be accessed. The results for petroleum hydrocarbon, VOC, Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 10 and PAH analyses showed all constituents to be non-detected at laboratory reporting limits or below screening levels with the exception of TPH-DRO in samples W-1 and W-5, which had concentrations of 7.0 milligrams per liter (mg/L) and 3.7 mg/L, respectively, which exceed the ISL for TPH-DRO. Dissolved arsenic was reported at concentrations above the Utah Ground Water Quality Standards (UGQS) in samples IHI-7GW, W-2, W-6, W-7, and IHI-9. Arsenic also exceeded the EPA MCL for all 10 samples collected with the exception of W-5 and W-8. Reports providing information about the LUST site at the property resulting from a release from the fueling center are discussed in the Records Review section of this report, Section 4.0. 3.8 Historical Use Information Summary The site has been used for industrial purposes since at least 1911 with the operation of a coal yard, an asphalt plant, vehicle repair shops, and fleet fueling and repair. In addition, railroad spurs crossed the northern portion of the site. Suspect uses at the site have been identified as light and heavy vehicle/equipment maintenance, engineering materials testing, street painting and stripping, sign painting, hazardous materials storage, automotive painting, vehicle washing, vehicle fueling, and waste oil collection and storage. Two subsurface investigations conducted at the site documented petroleum hydrocarbons, SVOCs, lead, and arsenic in soils at concentrations that exceeded a screening level at the site. The results of groundwater sampling as part of the two sampling events reported dissolved petroleum hydrocarbons, tetrachloroethene (PCE), SVOCs, and total metals at concentrations that exceeded a screening level in groundwater at the site. Historical industrial activities as well as sample results documenting impacts represent a REC to the site. 4.0 RECORDS REVIEW Regulatory database information was provided by GeoSearch, a contract information services company. The purpose of the records review was to identify RECs in connection with the site. Information in this section is subject to the accuracy of the data provided by the information services company and the date at which the information is updated, and the scope herein did not include confirmation of facilities listed as "unlocatable" by regulatory databases. In some of the following subsections, the words up-gradient, cross-gradient and down-gradient refer to the topographic gradient in relation to the site. As stated previously, the groundwater flow direction and the depth to shallow groundwater, if present, would likely vary depending upon seasonal variations in rainfall and the depth to the soil/bedrock interface. Without the benefit of on-site groundwater monitoring wells surveyed to a datum, groundwater depth and flow direction beneath the site cannot be directly ascertained. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 11 4.1 Federal and State/Tribal Databases Listed below are the facility listings identified on federal and state/tribal databases within the ASTM-required search distances from the approximate site boundaries. Database definition, descriptions, and the database search report are included in Appendix D. Federal Databases Database Description Distance (miles)Listings SEMS Superfund Enterprise Management System 0.5 1 SEMSARCH Superfund Enterprise Management System Archived Site Inventory 0.5 3 ERNS Emergency Response Notification System Site 0 IC / EC Institutional Control/Engineering Control Site 0 NPL National Priorities List 1 0 NPL (Delisted) National Priorities Delisted List 0.5 0 RCRA CORRACTS/ TSD RCRA Corrective Action Activity 1 0 RCRA Generators Resource Conservation and Recovery Act Site and adjoining properties 3 RCRA Non- CORRACTS/ TSD RCRA Non-Corrective Action Activity 0.5 0 State/Tribal Databases Database Description Distance (miles)Listings Brownfields Brownfields Assessment Sites 0.5 2 IC Institutional Controls Sites Site 0 LUST Leaking Underground Storage Tanks 0.5 52 SHWS State Hazardous Waste Sites 0.5 NA SWF/LF Solid Waste Facilities/Landfills 0.5 0 UST Underground Storage Tanks Site and adjoining properties 4 VCP Voluntary Cleanup Program 0.5 5 In addition to the above ASTM-required listings, Terracon reviewed other federal, state, local, and proprietary databases provided by the database firm. A list of the additional reviewed databases is included in the regulatory database report included in Appendix D. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 12 The following table summarizes the site-specific information provided by the database and/or gathered by this office for identified facilities.Facilities are listed in order of proximity to the site. Additional discussion for selected facilities follows the summary table. Listed Facilities Facility Name And Location Estimated Distance / Direction/Gradient Database Listings Is a REC, CREC, or HREC to the Site Salt Lake City Fleet Management / Salt Lake City Material / US Drug Enforcement Administration / Salt Lake City Shops Site UST, LUST, RCRA NLR, RCRA Generator, Brownfields, NPDES REC, discussed below Utah Barrel Inc. 370 W 900 S West-adjoining / cross- gradient RCRA, RCRA – NLR REC, discussed below Utah Barrel / Utah Barrel and Scrap / ArtSpace 850 S 400 W and 856 S 400 W West-adj across 400 W / Cross-gradient VCP, Brownfields No, based on file review discussed below Salt Lake Collision Repair 362 W 800 S / North-adj across 800 S Street RCRA - NLR No, based on file review discussed below Old Gas Station Site 800 S 300 W 120 ft. / East-adjoining across 300 W Street / cross-gradient UST, LUST No, based on file review discussed below Old Gas Station Project Site #EA-028-92 879 S 300 W / East-adj UST, LUST No, based on distance and gradient Gene Penman 66 775 S 300 W 264 ft. / NE / up-gradient UST, LUST No, based on file review discussed below DeVroom’s Garage 777 S 300 W 370 ft. / NE / up, cross- gradient UST, LUST No, based on distance and gradient Galigher Ash Co. 800 S 440 W 634 ft. / W / cross gradient SEMSARCH No, based on distance and gradient Old Salt Lake City Fire Station 200 W 700 S 792 ft. / NE / up, cross- gradient SEMSARCH No, based on file review discussed below Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 13 Fleet Management Yard The site is listed as an Underground Storage Tank (UST) and a Leaking Underground Storage Tank (LUST) facility, as well as a RCRA NLR, RCRA Generator, Brownfields, and NPDES facility. There are two facility IDs associated with the UST and LUST listings of the property.Facility ID 4001789 pertains to three waste oil USTs located at the northeast portion of the site, on the west side of the northernmost fleet maintenance shop. Records on DEQ’s website indicate one 550-gallon waste oil UST was closed by removal in 1991. A release was noted at the time of removal and issued release ID GRL. The release case was closed in 1992 and a NFA letter was issued. A copy of the NFA letter is included in Appendix C. A second waste oil UST was removed in 1999 and a third waste oil UST was closed by removal in 1999. The locations of the USTs closed in 1999 were not clear and no sampling information was provided. Samples collected by MSE and Terracon during subsequent investigations have not been situated adequately or have not analyzed for the proper constituents to evaluate impacts from these USTs, if present. The former waste oil USTs represent a REC to the site. Facility ID 4000835 is the former fueling station at the south-central portion of the site. Four USTs (two 10,000-gallon gasoline and two 10,000-gallon diesel tanks) were installed in 1987 to fuel Salt Lake City fleet vehicles. A suspected subsurface release of petroleum hydrocarbons originating from the area was reported to the Utah DERR on July 8, 1993, when petroleum odors were noted during the installation of tank system upgrades. The site was issued Facility Identification No. 4000835, and the release was recorded as Release ID IEQ. The USTs and associated pump island were excavated and removed from the site in September 2011. Closure samples collected during the removal of the USTs indicated petroleum hydrocarbons were still present at concentrations that exceeded DERR LUST Program’s Initial Screening Levels (ISLs) and Tier 1 Screening Levels. Subsequent investigations identified petroleum impacts to soil and groundwater extending beyond the tank basin. Terracon developed a corrective action plan to address the petroleum-impacted soils and groundwater remaining in the vicinity of the former UST tank basin. The selected approach included removal of the impacted soils for off-site disposal and removal of impacted groundwater from the open excavation, followed by a limited application of chemical oxidation reagents to treat residual petroleum-impacted groundwater within the excavation area prior to backfilling. Impacted soils above the ISL were removed from the area; however, groundwater monitoring conducted in 2015 identified dissolved petroleum hydrocarbon above ISLs still present down-gradient of the former tank basin. Terracon is concurrently investigating the extent of the groundwater plume resulting from the UST release. The groundwater plume with undefined downgradient extent represents a REC to the site. There are three RCRA listings for the site: Facility ID UTD980959480, Facility ID UTD981544364, and Facility ID UTD988071908. The listings cover disposal of a range of wastes, including halogenated solvents and universal wastes listed as batteries, lamps, Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 14 pesticides, and mercury-containing equipment. No violations were reported for the site for any of the listings. The RCRA listing is not considered a REC to the site. The site is listed as a Brownfield Property (DERR ID PRE14). As noted in Section 3.7 of this report, it was evaluated in 2005 as part of the Salt Lake City Gateway Brownfields Pilot Program. Details of the evaluation are presented in Section 3.7. The Brownfields listing is not considered an REC to the site. The site is also listed on the NPDES database for a 2014 permit. The permit was associated with the discharge of the treated groundwater following the UST investigation. No violations were noted. The NPDES listing is not considered a REC to the site. Utah Barrel Inc. (Facility ID UTD035387737) This RCRA facility adjoins the site immediately to the west, in the cross-gradient direction and originally registered for generator status in 1984, permitted as a small quantity generator for handling and disposing of ignitable waste, corrosive waste, spent halogenated solvents used in degreasing, and spent non-halogenated solvents. It was also permitted for handling universal wastes listed as batteries, lamps, pesticides, and mercury-containing equipment. One general violation was listed from 1986 that did not result in corrective action. Although little regulatory information is available about this facility, barrel supply businesses are frequently associated with releases of regulated materials. Due to its proximity to the site (west-adjoining), it represents an REC. Utah Barrel / Utah Barrel and Scrap / ArtSpace This facility is listed as a Brownfield Property (Facility ID 166302) and a VCP Site (Facility ID C061). It adjoins the site to the west, across 400 West Street, approximately 100 feet in the cross-gradient direction. It operated for over 45 years as an industrial scrap and salvage yard and conducted aboveground fuel storage. Contaminants of concern were identified as petroleum hydrocarbons, PCBs, and heavy metals, impacting both soil and groundwater. The site was enrolled in the Voluntary Protection Program (VCP_ in 2007 and underwent remediation, achieving a Certificate of Completion in 2010. It has subsequently been redeveloped as ArtSpace Commons, a commercial and residential development. There are institutional controls affecting land use. Due to its regulatory status, distance, and cross- gradient direction from the site, it does not represent a REC. Salt Lake Collision Repair (Facility ID UTD053807087) This facility is listed as a RCRA small quantity generator that is no longer regulated. It adjoins the site to the north, across 800 South Street, in the up-gradient direction, approximately 120 feet to the north. The facility was originally permitted for handling and disposal of spent halogenated solvents in 1985. There are no violations on record for this facility. Although it appeared to operate in compliance with regulations at the time and is no longer regulated, businesses of this type are commonly associated with releases of solvents and petroleum Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 15 hydrocarbons. Due to its distance and up-gradient direction Terracon believes it represents an REC to the site. Old Gas Station Site (Facility ID 4001922 / Release ID IBA) This UST and LUST site adjoins the site to the east, across 300 West Street, approximately 120 feet in the cross-gradient direction. A release of petroleum hydrocarbons was reported to the DEQ in 1993 when it was discovered during an investigation for a property transaction. Subsequent investigations found impacts to soil and groundwater above DERR’s regulatory cleanup levels. The release case was closed in 1995. Soil contaminants were below Tier 1 Screening Levels. Although benzene concentrations and Total Petroleum Hydrocarbons (TPH) remained above Tier 1 SLs in three of the four wells at the site, DERR concluded that risks to human health and the environment were minimal and issued a No Further Action letter on February 22, 1995. Due to the elapsed time since this release was evaluated and found to be low risk and its cross-gradient direction from the site, Terracon believes it does not represent a REC to the site. Gene Penman 66 (Facility ID 4000323 / Release ID JZO) This facility historically operated as a gas station and then as an automotive repair shop. It is located approximately 264 feet to the northeast, in the up-gradient direction. It was registered as a LUST site in 1997 during decommissioning of the USTs. The site has undergone investigations and remediation. Groundwater sampling in 2015 documented contaminant concentrations had decreased to below Initial Screening Levels (ISLs) and measured the direction of groundwater flow to the southeast. Based on the low levels of contaminants remaining at the facility, the distance and cross gradient direction from the site, this LUST and UST facility does not represent an REC to the site. Old Salt Lake City Fire Station (Facility ID UTD988066155) This facility was originally assessed for CERCLIS when solvents, detergents, greases were reportedly dumped into floor drains. Several chlorinated solvents were detected in soils and groundwater at the facility. A preliminary assessment was conducted in 1989 and later archived as it did not qualify for the National Priority List. Archived sites are typically considered low risk and designated as no further action required. Due to the distance from the site and its regulatory status, it does not represent an REC to the site. The remaining facilities listed in the database report do not appear to represent RECs to the site at this time based upon regulatory status, apparent topographic gradient, and/or distance from the site. Unlocatable facilities are those that do not contain sufficient address or location information to evaluate the facility listing locations relative to the site. The report listed one facility in the unlocatable section. Determining the location of unlocatable facilities is beyond the scope of this assessment; however, the facility was not identified as the site or adjacent properties. The facility is listed in the database report in Appendix D. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 16 4.2 Local Agency Inquiries Agency Contacted/ Contact Method Response Salt Lake Valley Health Department / by e-mail Ms. Ashley Hall, records manager, provided a report of complaints for the area surrounding and including the Fleet Management block. A review of the report of complaints did not indicate any environmental issues associated with the site or adjoining properties. 5.0 SITE RECONNAISSANCE 5.1 General Site Information Information contained in this section is based on a visual reconnaissance conducted while walking through the site and the accessible interior areas of structures, if any, located on the site. Exhibit 2 in Appendix A is a Site Diagram of the site. Photo documentation of the site at the time of the visual reconnaissance is provided in Appendix B. Credentials of the individuals planning and conducting the site visit are included in Appendix E. The site consists of the majority of one city block bounded by 800 South and 900 South Streets and 300 West and 400 West Streets. The southwest portion of the block is occupied by other commercial facilities. There are buildings, storage sheds, and open-air fenced storage areas on all sides of the block. The central area of the block is paved with asphalt. The following table lists the structures and general information about each structure or group of structures. Detailed descriptions of environmental issues identified at each building is provided in Section 5.4. General Site Information Site Reconnaissance Field Personnel Nancy Saunders Reconnaissance Date April 14, 2016 Weather Conditions Weather Site Contact/Title Todd Reeder / Capital Asset Manager Building Description Building Identification Building Use Approx Address Approx. Size (ft²) Shops K9 training, storage, storage of parking meters and parts 900 S 12,700 Covered storage sheds Currently unused 400 W 5,900 Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 17 Building Description Building Identification Building Use Approx Address Approx. Size (ft²) Storage/office building Vacant and dilapidated; previously used for office space and storage 800 S 4,100 Fleet Office Vacant and dilapidated; previously used for office space 325 W 800 S 1,250 Northern Maintenance Shop Currently unused, formerly used for large vehicle maintenance 350 W 800 S 9,910 Fleet Maintenance shops Currently used for storage of fire emergency vehicles, lawn and sidewalk maintenance supplies, miscellaneous storage 300 W 48,000 Street Maintenance Office Currently vacant, previously used as office space 300 W 5,180 Street Maintenance Garage Storage of miscellaneous equipment including city- owned bicycles 300 W 14,250 Site Utilities Drinking Water City of Salt Lake Wastewater City of Salt Lake 5.2 Overview of Current Site Occupants The majority of the site is used predominantly for storage by various city departments. Along the south section of the block, occupants include the Salt Lake City Police Department, K9 Unit, who use a portion of the building for training in the evenings, and the parking enforcement department for storage of parking meters and parts. The covered storage sheds along the west side of the block are essentially vacant. In the northwest corner of the site, the landscape services group stores landscaping materials, and there are two plastic aboveground storage tanks for mixing salt water for pre-wetting of roads in the open storage area. Farther to the north is an open, fenced storage area leased to Kentlands Institute, a non-profit organization, for storage of containers that are used seasonally as micro retail spaces. The northern portion of the block is unoccupied and consists of office space and one large shop building with a wash area in front. Along the east side of the block are shop and office spaces. The shop areas are used by the Salt Lake City Fire Department for storage and cleaning of vehicles (no service is conducted); and by the Salt Lake City Police Department for storage of miscellaneous items, such as tires, bicycles, and trailers. The office spaces are all currently vacant and many are dilapidated and unfit for occupancy. 5.3 Overview of Current Site Operations The occupied portions of the site are used for storage, as detailed above. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 18 5.4 Site Observations The following table summarizes site observations and interviews. Affirmative responses (designated by an “X”) are discussed in more detail following the table. Site Characteristics Category Item or Feature Observed or Identified Site Operations, Processes, and Equipment Emergency generators X Elevators Air compressors X Hydraulic lifts Dry cleaning Photo processing Ventilation hoods and/or incinerators Waste treatment systems and/or water treatment systems Heating and/or cooling systems Paint booths Sub-grade mechanic pits Wash-down areas or carwashes X Vehicle repair or maintenance Pesticide/herbicide production or storage Printing operations Metal finishing (e.g., electroplating, chrome plating, galvanizing, etc.) Salvage operations Oil, gas or mineral production Other processes or equipment Aboveground Chemical or Waste Storage Aboveground storage tanks X Drums, barrels and/or containers ³ 5 gallons X MSDS or SDS Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 19 Category Item or Feature Observed or Identified Underground Chemical or Waste Storage, Drainage or Collection Systems Underground storage tanks or ancillary UST equipment Sumps, cisterns, French drains, catch basins and/or dry wells X Grease traps Septic tanks and/or leach fields Oil/water separators, clarifiers, sand traps, triple traps, interceptors X Pipeline markers Interior floor drains X Electrical Transformers/ PCBs Transformers and/or capacitors X Other equipment Releases or Potential Releases Stressed vegetation Stained soil Stained pavement or similar surface Leachate and/or waste seeps Trash, debris and/or other waste materials Dumping or disposal areas Construction/demolition debris and/or dumped fill dirt Surface water discoloration, odor, sheen, and/or free floating product Strong, pungent or noxious odors Exterior pipe discharges and/or other effluent discharges Other Notable Site Features Surface water bodies Quarries or pits Wastewater lagoons Wells Site Operations, Processes, and Equipment Emergency generators One emergency generator was observed during the site reconnaissance in a fenced enclosure on the east side of the property. The generator was fueled by diesel fuel. There was significant staining around the surface in the vicinity of the unit. As the asphalt surface around the unit was deteriorating, the staining represents an REC. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 20 Air compressors One air compressor was observed on the east side of the property, outside the shop buildings. The air compressor was on a concrete pad. Minor surficial staining was observed on the compressor and in the vicinity of the air compressor at the time of the visual reconnaissance. Due to the intact concrete pad surface and the minimal staining observed, the air compressor does not represent an REC. Wash-down areas or carwashes A wash-down area was observed on the northern portion of the site. The wash-down area was equipped with four drains. It was not clear if the drains are connected to the storm water system or to the sanitary system. It is likely that when the wash down area was in use, significant amounts of sediment, oils, and detergents were introduced into the drains. This historical wash- down area represents an REC. Aboveground Chemical or Waste Storage Aboveground storage tanks Two plastic ASTs were observed on the west side of the site during the site reconnaissance. The ASTs are used for storing and mixing salt water brine. Staining and/or releases were not observed in the vicinity of the AST during the site reconnaissance. Drums, barrels, and/or containers ³ 5 gallons Three plastic 55-gallon drums were observed in the outside storage area on the west side of the site during the site reconnaissance. These were labeled “hydrogen peroxide.” Staining and/or releases were not observed on the drums or on the asphalt in the vicinity of the drums. Three drums were observed inside the second bay of the shop building on the east side of the block. These contained antifreeze and automotive cleaning fluid. They were stored on wooden pallets over an intact concrete floor. Staining and/or releases were not observed on the drums or on the floor in the vicinity of the drums. There is a concrete enclosure located on the northeast corner of the site labeled “Used Motor Oil Only.” There were no storage containers inside the enclosure at the time of the inspection; however, the concrete floor of the enclosure was heavily stained with oil. As the concrete was intact, the oil staining represents a de minimis condition. A second fenced enclosure, also along the northern property boundary, was labeled “oil barrel storage.” Significant staining was not observed in this enclosure. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 21 Underground Chemical or Waste Storage, Drainage or Collection Systems Sumps, cisterns, catch basins and/or dry wells A sump was observed outside the northern shop building during the site reconnaissance. Significant amounts of staining were noted in the vicinity of the sump. This area has not been evaluated in previous investigations. Due to the age of the feature and the presence of extensive staining, this sump constitutes an REC. A second sump was observed in the southwest portion of the site, between the covered sheds and the offices along 900 South Street. The sump appeared to be connected to a trench drain. The purpose of the sump was not clear. This area has not been evaluated in previous investigations. Although staining was not evident, the age of the feature and its unknown use constitute a REC. Oil/water separators, clarifiers, sand traps, triple traps, interceptors Two likely oil/water separators were observed at the northeast portion of the site during the site reconnaissance (Appendix A; Exhibit 2). No information was available on the units; however, they likely collect discharges from the floor drains in the northern and eastern shop buildings and possibly the wash-down areas farther west. Due to the age of the units, they constitute RECs to the site. An oil/water separator is located in the western portion of the northern shop building. During a previous site reconnaissance, Terracon observed significant amounts of oil and sludge in the separator. Due to the age of the units and the fact that they currently contain oil and sludge, they constitute RECs to the site. Interior floor drains Interior floor drains were observed at the following site locations: two trench drains were observed in the shop building on the north side of the block and five trench drains were observed in the shop buildings on the east side of the block. Staining and accumulated sludge was observed with several of the drains. It was not clear if these drains are connected to oil/water separators or if they discharge directly to the sanitary sewer system. Although no hazardous materials were observed in the vicinity of the drains during the site reconnaissance, historical and regulatory file review indicate hazardous materials and petroleum hydrocarbons have been used at the site in the past. Due to the age of these features, they represent a REC to the site. Electrical Transformers/PCBs Transformers and/or capacitors During Terracon’s site visit, one pad-mounted transformer, owned and serviced by PacifiCorp, was observed at the northeast corner of the site; however, no information with regard to PCB Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 22 content of the transformer fluids was observed. Some transformers contain mineral oil which may contain PCBs. PacifiCorp maintains responsibility for the transformers, and if the transformers were “PCB contaminated,” PacifiCorp is not required to replace the transformer fluids until a release is identified. However, evidence of current or prior release was not observed in the vicinity of the electrical equipment during the site reconnaissance. 6.0 ADJOINING PROPERTY RECONNAISSANCE Visual observations of adjoining properties (from site boundaries) are summarized below. Adjoining Properties Direction Description North The site is adjoined to the north by 800 South Street. Beyond the street, from east to west, are the following businesses: 778 S 300 W: Chic & Unique second-hand household goods; 316 W 800 S: SLJ Automotive Repair; 330 W 800 S: AAA Automotive; 334 W 800 S: Specialty Steel Service (distributors of steel products and also provides production cutting and cold sawing); 362 W 800 S: Driftwood Autobody; 380 W 800 S: Office building. East The site is adjoined to the east by 300 West Street. Beyond the street from north to south are: 813 S 300 W: Outlet Muffler and Tires; residences; 278 W 900 S: Basic Storage South The site is adjoined to the south by 900 South Street. Beyond the street, from east to west are: 910 S 300 W: Big O Tires; residences; Gale Street; 845 West 900 South: Triple “T” Maintenance Service; 865 West 900 S: Wildcat Construction; West From north to south, the site is adjoined to the west by: 400 W Street to approximately the middle of the block. On the west side of 400 West Street is: 824 S 400 W: Artspace Commons’ residential and commercial development; 370 W 900 S: City Cab. The site is adjoined on the north side by several small automotive repair and auto-body shops. These types of businesses are frequently associated with releases of petroleum hydrocarbons and solvents. The detection of PCE, a chlorinated solvent, in a sample collected by MSE in 2005 on the north side of the site property suggests there may be off-site impacts from one or more of these suspect businesses. No RECs associated with the remaining properties were observed. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 23 7.0 ADDITIONAL SERVICES Per the agreed scope of services specified in the proposal, additional services (e.g. asbestos sampling, lead-based paint sampling, wetlands evaluation, lead in drinking water testing, radon testing, vapor encroachment screening, etc.) were not conducted. Phase I Environmental Site Assessment Salt Lake City Fleet Management Yard ■ Salt Lake City, UT May 2, 2016 ■ Terracon Project No. 61167208 Responsive ■Resourceful ■Reliable 24 8.0 DECLARATION I, Nancy Saunders, declare that, to the best of my professional knowledge and belief, I meet the definition of Environmental Professional as defined in Section 312.10 of 40 CFR 312; and I have the specific qualifications based on education, training, and experience to assess a property of the nature, history, and setting of the site. I have developed and performed the All Appropriate Inquiries in conformance with the standards and practices set forth in 40 CFR Part 312. __________________________ Nancy Saunders Project Environmental Scientist I APPENDIX A EXHIBIT 1 – TOPOGRAPHIC MAP EXHIBIT 2 – SITE DIAGRAM TOPOGRAPHIC MAP Salt Lake City Fleet Management Yard 850 South 300 West Salt Lake City, UT TOPOGRAPHIC MAP IMAGE COURTESY OF THE U.S. GEOLOGICAL SURVEY QUADRANGLES INCLUDE: SALT LAKE CITY NORTH, UT (1/1/1998) and SALT LAKE CITY SOUTH, UT (1/1/1999). 6949 S High Tech Dr Ste 100 Midvale, UT 84047-3707 61167208 Project Manager: Drawn by: Checked by: Approved by: NMS BBB BBB 1”=2,000’ Ex 1 4/29/16 Project No. Scale: File Name: Date: 1 ExhibitNMS APPROXIMATE SITE BOUNDARY Project No. Task No. Scale: Date: 61167208 0 Not to Scale 4/29/16 Project Mngr: Drawn By: Checked By: Approved By: NMS NMS BBB BBB SITE DIAGRAM Salt Lake City Fleet Block 300 West to 400 West 800 South Salt Lake City, Utah EXHIBIT 2DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES. Open Storage LUST Facility 4000835 LUST Facility 4001789 Wash-down area Generator O/W/S Sump Trench Drain Storage Shop / maintenance Shop / m aintenance Shop / maintenance Trench Drain Historical Coal Yard Historical Asphalt Plant W1 Sump W5 W3 W10 B4 MSE Sample location where results exceeded a screening level Covered storage sheds Historical Garage / Machine Shop Historical Asphalt Plant Office 6949 S High Tech Dr Ste 100 Midvale, UT 84047-3707 O/W/S Oil / water separator ADJOINING PROPERTIES SLC Fleet Management Yard 850 South 300 West Salt Lake City, UT 6949 S High Tech Dr Ste 100 Midvale, UT 84047-3707 DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES 61167208 AERIAL PHOTOGRAPHY PROVIDED BY MICROSOFT BING MAPS NMS BBB BBB AS SHOWN Ex 3 4/29/16 Scale: 3 ExhibitProject Manager: Drawn by: Checked by: Approved by: Project No. File Name: Date: NMS APPROXIMATE SITE BOUNDARY Office Building 380 W 800 S Specialty Steel 334 W 800 S AAA Automotive 330 W 800 S SLJ Auto Repair 316 W 800 S Chic & Unique Furniture 778 S 300 W Driftwood Autobody 362 W 800 S ArtSpace Commons 824 S 400 W City Cab 370 W 900 S Wildcat Construction 865 West 900 S Triple “T” Maintenance Service 845 West 900 South: Big O Tires 910 S 300 W Outlet Muffler and Tire 813 S 300 W Residences Basic Storage 278 W 900 S APPENDIX B SITE PHOTOGRAPHS Phase I Environmental Site Assessment Fleet Management Yard ■Salt Lake City, Utah Photos Taken:April 14, 2016 ■Terracon Project No.61167208 Reliable ■Responsive ■Resourceful 1 Fleet Management Block East side of Fleet Block, looking northwest. Maintenance shops on east side of fleet block. Storage sheds on north side of fleet block. Northern maintenance shop.Typical covered storage shed on west side of fleet block. Phase I Environmental Site Assessment Fleet Management Yard ■Salt Lake City, Utah Photos Taken:April 14, 2016 ■Terracon Project No.61167208 Reliable ■Responsive ■Resourceful 2 Landscape material storage on west side of property. Fenced container storage area. Emergency generator located on east side of block. Air compressor located on east side of block. Wash-down area on north side of block. Plastic ASTs on west side of property. Phase I Environmental Site Assessment Fleet Management Yard ■Salt Lake City, Utah Photos Taken:April 14, 2016 ■Terracon Project No.61167208 Reliable ■Responsive ■Resourceful 3 Three drums storing hydrogen peroxide on west side of block. Drum storage inside maintenance building on east side of block. Used oil storage containment.Oil barrel storage enclosure. Sump located outside of northern shop building. Sump at southwest corner of property. Phase I Environmental Site Assessment Fleet Management Yard ■Salt Lake City, Utah Photos Taken:April 14, 2016 ■Terracon Project No.61167208 Reliable ■Responsive ■Resourceful 4 Oil/water separator on south side of northern shop building. Oil/water separator at northeast corner of property. One of seven floor drains –this one is in the northern shop bldg. One of seven floor drains –this one is in the eastern shop bldg. Pad-mounted transformer located at northeast corner of block. N-adj property: small automotive shops. Phase I Environmental Site Assessment Fleet Management Yard ■Salt Lake City, Utah Photos Taken:April 14, 2016 ■Terracon Project No.61167208 Reliable ■Responsive ■Resourceful 5 N-adj property: Specialty Steel and an auto-body shop. N-adj property:office building. E-adj property: Outlet Muffler and Tire shop. E-adj properties: residences. E-adj property: Basic Storage.S-adj property: Big O Tires. Phase I Environmental Site Assessment Fleet Management Yard ■Salt Lake City, Utah Photos Taken:April 14, 2016 ■Terracon Project No.61167208 Reliable ■Responsive ■Resourceful 6 S-adj property: residences.S-adj property: HVAC repair shop. S-adj property:Wildcat Construction.W-adj property:Artspace Commons. W-adj property: City Cab APPENDIX C HISTORICAL DOCUMENTATION AND USER QUESTIONNAIRE APPENDIX C.1 User Questionnaire APPENDIX C.2 Historical Aerials www.geo-search.com 888-396-0042 Order# 65948 Job# 143170 www.geo-search.com 888-396-0042 Order# 65948 Job# 143170 Date Source Scale Frame www.geo-search.com 888-396-0042 Order# 65948 Job# 143170 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' USDA 2014 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' USGS 08/10/2006 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 50' USGS 10/04/1997 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 1320' USGS 09/09/1987 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' USGS 08/04/1981 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' ASCS 1977 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' NASA 07/09/1973 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' USGS 08/02/1962 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' CDD 05/27/1958 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' USGS 06/20/1950 61167208 Fleet Block 325 W 800 S Salt Lake City, Utah 84101 6949 High Tech Drive, Suite 100 Midvale, Utah 84047 1" = 500' ASCS 09/13/1937 61167208 APPENDIX C.3 MSE Report, Abridged DEPARTMEN T OF ENVIRONMENTA L QUALIT Y DIVISIO N OF ENVIRONMENTA L RESPONS E AND REMEDIATIO N Norman H. Bangerter Governor Kenneth L. Alkema Executive Director Kent P. Gray Director 1950 West North Temple Salt Lake City. Utah (801)536-410 0 (801) 536-409 9 Fax Decembe r 4, 1992 Reply to- State of Utah Division ot Environmenta l Response and Remediatio n Departmen t of Environmenta l Quality Salt Lake City, Utah 84114-484 0 ERRL-1309-9 2 Ron Love Salt Lake City Corporatio n City and Count y Building Salt Lake City, Utah 8411 8 Re: Releas e Site EGR L Facility Identificatio n No. 400178 9 SCANNE D DERR h n ^ - 0^>C^^^ "^ Dear Mr. Love: The Utah Divisio n of Environmenta l Respons e and Remediatio n (Division), Undergroun d Storage Tank (UST) Branch has reviewe d the case file for the facility identified above (Facility). The Division's technica l staff has recommende d that no fiulher action be taken at this time, based upon its revie w of the informatio n contained in the file. The Division's file for this Facility primaril y consists of informatio n which you have submitted . The Division's technical staff has relied on this informatio n and has not made an independen t investigatio n of the Facility . The informatio n containe d in the file indicate s that the work conducte d at the Facilit y was performe d in accordanc e with Utah Administrativ e Code Rule R315-I0 1 (Correctiv e Actio n Cleanu p Standard s Policy). The informatio n which you have submitte d also indicate s that the petroleu m release and contaminatio n at the Facilit y no longer constitute s a threat to human health and the environment . A determinatio n has been made that no further action is required at this time. Thi s determination , however , is made subjec t to the conditio n that additional action may be require d if other evidence indicate s a spread of contaminatio n from the Facilit y which constimte s a threat to human health or the environment . Sincerely , Kent P. Gray, Executiv e Secretar y (UST ) Utah Solid and Hazardou s Waste Contro l Board KPG/RS/sb q cc: Harr y L. Gibbons, M.D., M.P.H., Director , Salt Lake City/County Health Departmen t Printed on recycled paper y ^ /o/^./,^ ^,y ^ !-?/f^ APPENDIX C.4 NFA Letter for LUST Site 4001789 APPENDIX D ENVIRONMENTAL DATABASE INFORMATION Radius Report Satellite view Target Property: Fleet Block 325 W 800 S Salt Lake City, Salt Lake County, Utah 84101 Prepared For: Terracon Consultants-Salt Lake City Order #: 65948 Job #: 143169 Project #: 61167208 PO #: 61167208 Date: 04/22/2016 0 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property Summary 1 Database Summary 2 Database Radius Summary 6 Radius Map 1 10 Radius Map 2 11 Ortho Map 12 Topographic Map 13 Located Sites Summary 14 Elevation Summary 20 Unlocated Sites Summary 185 Environmental Records Definitions 187 Unlocatable Report See Attachment Zip Report See Attachment www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (UT)Environmental Records Definitions - TRIBALTable of Contents This report was designed by GeoSearch to meet or exceed the records search requirements of the All Appropriate Inquiries Rule (40 CFR §312.26) and the current version of the ASTM International E1527, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process or, if applicable, the custom requirements requested by the entity that ordered this report. The records and databases of records used to compile this report were collected from various federal,state and local governmental entities. It is the goal of GeoSearch to meet or exceed the 40 CFR §312.26 and E1527 requirements for updating records by using the best available technology. GeoSearch contacts the appropriate governmental entities on a recurring basis. Depending on the frequency with which a record source or database of records is updated by the governmental entity, the data used to prepare this report may be updated monthly, quarterly, semi-annually, or annually. The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer's interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers And independent contractors cannot be held liable For actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (UT)Environmental Records Definitions - TRIBALTable of ContentsDisclaimer Target Property Information Fleet Block 325 W 800 S Salt Lake City, Utah 84101 Coordinates Area centroid (-111.90099, 40.7509481) 4,232 feet above sea level USGS Quadrangle Salt Lake City South, UT Salt Lake City North, UT Geographic Coverage Information County/Parish: Salt Lake (UT) ZipCode(s): Salt Lake City UT: 84101, 84104, 84111, 84115 Radon * Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). 1 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property Summary FEDERAL LISTING Standard Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) EMERGENCY RESPONSE NOTIFICATION SYSTEM ERNSUT 0 1 TP/AP FEDERAL ENGINEERING INSTITUTIONAL CONTROL SITES EC 0 0 TP/AP LAND USE CONTROL INFORMATION SYSTEM LUCIS 0 0 TP/AP RCRA SITES WITH CONTROLS RCRASC 0 0 TP/AP NO LONGER REGULATED RCRA GENERATOR FACILITIES NLRRCRAG 4 0 0.1250 RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES RCRAGR08 5 0 0.1250 RESOURCE CONSERVATION & RECOVERY ACT - NON- GENERATOR FACILITIES RCRANGR08 7 0 0.1250 BROWNFIELDS MANAGEMENT SYSTEM BF 1 0 0.5000 DELISTED NATIONAL PRIORITIES LIST DNPL 0 0 0.5000 NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES NLRRCRAT 1 0 0.5000 RESOURCE CONSERVATION & RECOVERY ACT - NON-CORRACTS TREATMENT, STORAGE & DISPOSAL FACILITIES RCRAT 0 0 0.5000 SUPERFUND ENTERPRISE MANAGEMENT SYSTEM SEMS 1 0 0.5000 SUPERFUND ENTERPRISE MANAGEMENT SYSTEM ARCHIVED SITE INVENTORY SEMSARCH 3 0 0.5000 NATIONAL PRIORITIES LIST NPL 0 0 1.0000 NO LONGER REGULATED RCRA CORRECTIVE ACTION FACILITIES NLRRCRAC 0 0 1.0000 PROPOSED NATIONAL PRIORITIES LIST PNPL 0 0 1.0000 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES RCRAC 0 0 1.0000 RESOURCE CONSERVATION & RECOVERY ACT - SUBJECT TO CORRECTIVE ACTION FACILITIES RCRASUBC 0 0 1.0000 SUB-TOTAL 22 1 Additional Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) AEROMETRIC INFORMATION RETRIEVAL SYSTEM / AIR FACILITY SUBSYSTEM AIRSAFS 0 0 TP/AP BIENNIAL REPORTING SYSTEM BRS 0 0 TP/AP CERCLIS LIENS SFLIENS 0 0 TP/AP CLANDESTINE DRUG LABORATORY LOCATIONS CDL 0 0 TP/AP EPA DOCKET DATA DOCKETS 0 0 TP/AP FACILITY REGISTRY SYSTEM FRSUT 10 0 TP/AP 2 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase Summary Database Acronym Locatable Unlocatable Search Radius (miles) HAZARDOUS MATERIALS INCIDENT REPORTING SYSTEM HMIRSR08 0 0 TP/AP INTEGRATED COMPLIANCE INFORMATION SYSTEM (FORMERLY DOCKETS) ICIS 0 0 TP/AP INTEGRATED COMPLIANCE INFORMATION SYSTEM NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ICISNPDES 2 0 TP/AP MATERIAL LICENSING TRACKING SYSTEM MLTS 0 0 TP/AP NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NPDESR08 0 0 TP/AP PCB ACTIVITY DATABASE SYSTEM PADS 0 0 TP/AP PERMIT COMPLIANCE SYSTEM PCSR08 0 0 TP/AP SECTION SEVEN TRACKING SYSTEM SSTS 0 0 TP/AP TOXIC SUBSTANCE CONTROL ACT INVENTORY TSCA 0 0 TP/AP TOXICS RELEASE INVENTORY TRI 0 0 TP/AP HISTORICAL GAS STATIONS HISTPST 0 0 0.2500 OPEN DUMP INVENTORY ODI 0 0 0.5000 DEPARTMENT OF DEFENSE SITES DOD 0 0 1.0000 FORMERLY USED DEFENSE SITES FUDS 0 0 1.0000 RECORD OF DECISION SYSTEM RODS 0 0 1.0000 SUB-TOTAL 12 0 3 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase Summary STATE (UT) LISTING Standard Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) INSTITUTIONAL ENGINEERING CONTROLS REGISTRY ICEC 0 0 TP/AP REGISTERED UNDERGROUND STORAGE TANKS RUST 24 0 0.2500 BROWNFIELD PROPERTIES BF 2 0 0.5000 CERCLIS SITES CERCLIS 4 0 0.5000 LANDFILL AND SOLID WASTE DISPOSAL SITES LFSWDS 0 0 0.5000 LEAKING UNDERGROUND STORAGE TANKS LUST 52 0 0.5000 VOLUNTARY CLEANUP PROGRAM SITES VCP 5 0 0.5000 NATIONAL PRIORITIES LIST NPL 0 0 1.0000 SUB-TOTAL 87 0 Additional Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) TIER II FACILITIES TIERII 0 0 TP/AP SUB-TOTAL 0 0 4 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase Summary TRIBAL LISTING Standard Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) UNDERGROUND STORAGE TANKS ON TRIBAL LANDS USTR08 0 0 0.2500 LEAKING UNDERGROUND STORAGE TANKS ON TRIBAL LANDS LUSTR08 0 0 0.5000 OPEN DUMP INVENTORY ON TRIBAL LANDS ODINDIAN 0 0 0.5000 SUB-TOTAL 0 0 Additional Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) INDIAN RESERVATIONS INDIANRES 0 0 1.0000 SUB-TOTAL 0 0 TOTAL 121 1 5 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase Summary FEDERAL LISTING Standard environmental records are displayed in bold. Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2)> 1 Mile Total AIRSAFS 0.0200 0 NS NS NS NS NS 0 BRS 0.0200 0 NS NS NS NS NS 0 CDL 0.0200 0 NS NS NS NS NS 0 DOCKETS 0.0200 0 NS NS NS NS NS 0 EC 0.0200 0 NS NS NS NS NS 0 ERNSUT 0.0200 0 NS NS NS NS NS 0 FRSUT 0.0200 10 NS NS NS NS NS 10 HMIRSR08 0.0200 0 NS NS NS NS NS 0 ICIS 0.0200 0 NS NS NS NS NS 0 ICISNPDES 0.0200 2 NS NS NS NS NS 2 LUCIS 0.0200 0 NS NS NS NS NS 0 MLTS 0.0200 0 NS NS NS NS NS 0 NPDESR08 0.0200 0 NS NS NS NS NS 0 PADS 0.0200 0 NS NS NS NS NS 0 PCSR08 0.0200 0 NS NS NS NS NS 0 RCRASC 0.0200 0 NS NS NS NS NS 0 SFLIENS 0.0200 0 NS NS NS NS NS 0 SSTS 0.0200 0 NS NS NS NS NS 0 TRI 0.0200 0 NS NS NS NS NS 0 TSCA 0.0200 0 NS NS NS NS NS 0 NLRRCRAG 0.1250 2 2 NS NS NS NS 4 RCRAGR08 0.1250 1 3 NS NS NS NS 4 RCRANGR08 0.1250 4 3 NS NS NS NS 7 HISTPST 0.2500 0 0 0 NS NS NS 0 BF 0.5000 0 1 0 0 NS NS 1 DNPL 0.5000 0 0 0 0 NS NS 0 NLRRCRAT 0.5000 1 0 0 0 NS NS 1 ODI 0.5000 0 0 0 0 NS NS 0 RCRAT 0.5000 0 0 0 0 NS NS 0 SEMS 0.5000 0 0 0 1 NS NS 1 SEMSARCH 0.5000 0 1 1 1 NS NS 3 DOD 1.0000 0 0 0 0 0 NS 0 FUDS 1.0000 0 0 0 0 0 NS 0 NLRRCRAC 1.0000 0 0 0 0 0 NS 0 NPL 1.0000 0 0 0 0 0 NS 0 6 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius Summary Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2)> 1 Mile Total PNPL 1.0000 0 0 0 0 0 NS 0 RCRAC 1.0000 0 0 0 0 0 NS 0 RCRASUBC 1.0000 0 0 0 0 0 NS 0 RODS 1.0000 0 0 0 0 0 NS 0 SUB-TOTAL 20 10 1 2 0 0 33 7 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius Summary STATE (UT) LISTING Standard environmental records are displayed in bold. Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2)> 1 Mile Total ICEC 0.0200 0 NS NS NS NS NS 0 TIERII 0.0200 0 NS NS NS NS NS 0 RUST 0.2500 3 8 12 NS NS NS 23 BF 0.5000 1 0 0 1 NS NS 2 CERCLIS 0.5000 0 0 2 2 NS NS 4 LFSWDS 0.5000 0 0 0 0 NS NS 0 LUST 0.5000 3 4 10 35 NS NS 52 VCP 0.5000 0 1 1 3 NS NS 5 NPL 1.0000 0 0 0 0 0 NS 0 SUB-TOTAL 7 13 25 41 0 0 86 8 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius Summary TRIBAL LISTING Standard environmental records are displayed in bold. Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2)> 1 Mile Total USTR08 0.2500 0 0 0 NS NS NS 0 LUSTR08 0.5000 0 0 0 0 NS NS 0 ODINDIAN 0.5000 0 0 0 0 NS NS 0 INDIANRES 1.0000 0 0 0 0 0 NS 0 SUB-TOTAL 0 0 0 0 0 0 0 TOTAL 27 23 26 43 0 0 119 NOTES: NS = NOT SEARCHED TP/AP = TARGET PROPERTY/ADJACENT PROPERTY 9 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius Summary .2 Click here to access Satellite view 10 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryRadius Map 1 .3 Click here to access Satellite view 11 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryRadius Map 2 .4 Click here to access Satellite view 12 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryOrtho Map .5 Click here to access Satellite view 13 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryTopographic Map NOTE: Standard environmental records are displayed in bold. Map ID# Database Name Site ID#Relative Elevation Distance From Site Site Name Address PAGE # 1 FRSUT 110002262685 Lower (4,229 ft.) TP FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84101 24 1 FRSUT 110005200665 Lower (4,229 ft.) TP SALT LAKE CITY FLEET YARD 850 SOUTH 300 WEST BLDG. NO. 3, SALT LAKE CITY, UT 84101 25 1 FRSUT 110031321889 Lower (4,229 ft.) TP US DRUG ENFORCEMENT ADMINISTRATION 850 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 26 1 FRSUT 110058285653 Lower (4,229 ft.) TP SALT LAKE CITY FLEET YARD 850 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 27 1 FRSUT 110041915265 Lower (4,229 ft.) TP SALT LAKE CITY CORPORATION FLEET YARD 325 W 800 S, SALT LAKE CITY, UT 84101 28 1 ICISNPDES UTG070539INP DES Lower (4,229 ft.) TP SALT LAKE CITY FLEET YARD 850 SOUTH 300 WEST, SALT LAKE CITY, UT 29 1 ICISNPDES UTR000937INP DES Lower (4,229 ft.) TP SALT LAKE CITY CORPORATION FLEET YARD 325 W 800 S, SALT LAKE CITY, UT 84101 31 1 NLRRCRAG UTD980959480 Lower (4,229 ft.) TP SALT LAKE CITY MATERIAL 850 SOUTH 300 WEST BLDG. NO. 3, SALT LAKE CITY, UT 84101 33 1 NLRRCRAT UTD981544364 Lower (4,229 ft.) TP SALT LAKE CITY FLEET MGMT 325 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 35 1 RCRAGR08 UTD981544364 Lower (4,229 ft.) TP SALT LAKE CITY FLEET MGMT 325 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 37 1 RCRANGR08 UTD988071908 Lower (4,229 ft.) TP US DRUG ENFORCEMENT ADMINISTRATION 850 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 39 1 RCRANGR08 UTD980959480 Lower (4,229 ft.) TP SALT LAKE CITY MATERIAL 850 SOUTH 300 WEST BLDG. NO. 3, SALT LAKE CITY, UT 84101 41 1 BF PRE14 Lower (4,229 ft.) TP FLEET MANAGEMENT YARD BROWNFIELDS PILOT PROJECT BETWEEN 900 SOUTH AND 800 SOUTH AND 300 WEST AND 400 WEST, SALT LAKE CITY, UT 84101 43 1 LUST 4000835LUST Lower (4,229 ft.) TP FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 44 1 LUST 4001789LUST Lower (4,229 ft.) TP FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 45 1 RUST 4000835 Lower (4,229 ft.) TP FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 46 1 RUST 4001789 Lower (4,229 ft.) TP FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 51 1 FRSUT 110005201478 Lower (4,229 ft.) TP SALT LAKE CITY CORPORATION FLEET YARD 325 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 53 2 FRSUT 110057322026 Lower (4,229 ft.) 0.02 mi. E (106 ft.) NORMAN CO 312 WEST 800 SOUTH, SLC, UT 84101 54 2 LUST 4001922LUST Lower (4,229 ft.) 0.01 mi. E (53 ft.) OLD GAS STATION SITE 800 S 300 W, SALT LAKE CITY, UT 84101 55 2 RUST 4001922 Lower (4,229 ft.) 0.01 mi. E (53 ft.) OLD GAS STATION SITE 800 S 300 W, SALT LAKE CITY, UT 84101 56 2 FRSUT 110020108612 Lower (4,229 ft.) 0.01 mi. E (53 ft.) OLD GAS STATION SITE 800 S 300 W, SALT LAKE CITY, UT 84101 58 14 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 3 NLRRCRAG UTD053807087 Equal (4,232 ft.) 0.04 mi. NE (211 ft.) SALT LAKE COLLISON REPAIR 362 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 59 3 RCRANGR08 UTD980953574 Equal (4,232 ft.) 0.02 mi. E (106 ft.) SALT LAKE CITY SHOPS 350 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 61 3 RCRANGR08 UTD053807087 Equal (4,232 ft.) 0.04 mi. NE (211 ft.) SALT LAKE COLLISON REPAIR 362 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 63 3 FRSUT 110031313380 Equal (4,232 ft.) 0.02 mi. E (106 ft.) SALT LAKE CITY SHOPS 350 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 65 4 NLRRCRAG UTD035387737 Lower (4,229 ft.) 0.02 mi. S (106 ft.) UTAH BARREL INC.370 WEST 900 SOUTH, SALT LAKE CITY, UT 84110 66 4 RCRANGR08 UTD035387737 Lower (4,229 ft.) 0.02 mi. S (106 ft.) UTAH BARREL INC.370 WEST 900 SOUTH, SALT LAKE CITY, UT 84110 68 4 FRSUT 110005196803 Lower (4,229 ft.) 0.02 mi. S (106 ft.) UTAH BARREL INC.370 WEST 900 SOUTH, SALT LAKE CITY, UT 84110 70 5 RUST 4001923 Lower (4,229 ft.) 0.03 mi. SE (158 ft.) OLD GAS STATION - PROJECT SITE #EA- 028-92 879 S 300 W, SALT LAKE CITY, UT 84101 71 5 LUST 4001923LUST Lower (4,229 ft.) 0.03 mi. SE (158 ft.) OLD GAS STATION - PROJECT SITE #EA- 028-92 879 S 300 W, SALT LAKE CITY, UT 84101 74 6 LUST 4002432LUST Lower (4,229 ft.) 0.07 mi. E (370 ft.) DEVROOM'S GARAGE 777 S 300 W, SALT LAKE CITY, UT 84106 75 6 RUST 4000323 Lower (4,229 ft.) 0.05 mi. E (264 ft.) GENE PENMAN 66 775 S 300 W, SALT LAKE CITY, UT 84101 76 6 RUST 4002432 Lower (4,229 ft.) 0.07 mi. E (370 ft.) DEVROOM'S GARAGE 777 S 300 W, SALT LAKE CITY, UT 84106 78 6 LUST 4000323LUST Lower (4,229 ft.) 0.05 mi. E (264 ft.) GENE PENMAN 66 775 S 300 W, SALT LAKE CITY, UT 84101 79 7 RCRANGR08 UTP000000034 Lower (4,229 ft.) 0.06 mi. NE (317 ft.) ARO PICKLE FACTORY 741 SOUTH 400 WEST, SALT LAKE CITY, UT 84111 80 8 BF 166302 Lower (4,229 ft.) 0.06 mi. SW (317 ft.) UTAH BARREL AND SCRAP 850 SOUTH 400 WEST, SALT LAKE CITY, UT 84111 82 9 RCRANGR08 UTD988070934 Equal (4,232 ft.) 0.07 mi. SE (370 ft.) CITY WELDING & RADIATOR WORKS 259 WEST 900 SOUTH, SALT LAKE CITY, UT 84101 83 9 NLRRCRAG UTD988070934 Equal (4,232 ft.) 0.07 mi. SE (370 ft.) CITY WELDING & RADIATOR WORKS 259 WEST 9TH SOUTH, SALT LAKE CITY, UT 84101 85 10 RCRAGR08 UTD035347319 Equal (4,232 ft.) 0.08 mi. E (422 ft.) A&E ALTERNATOR AND STARTERS 264 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 87 11 RUST 4000536 Lower (4,229 ft.) 0.09 mi. S (475 ft.) C/O METRO STEEL 401 W 900 S, SALT LAKE CITY, UT 84101 89 12 RUST 4001610 Lower (4,229 ft.) 0.09 mi. W (475 ft.) WAREHOUSE 453 W 800 S, SALT LAKE CITY, UT 84101 91 13 VCP VCP-C061 Equal (4,232 ft.) 0.09 mi. SW (475 ft.) UTAH BARREL AND SCRAP - ARTSPACE 850 SOUTH 400 WEST AND 856 SOUTH 400 WEST, SALT LAKE CITY, UT 84101 92 14 RCRAGR08 UTD982590994 Lower (4,229 ft.) 0.09 mi. S (475 ft.) VENTURA'S CUSTOM AUTO PAINTING 372 WEST AMERICAN AVE., SALT LAKE CITY, UT 84101 94 15 RUST 4000927 Lower (4,229 ft.) 0.11 mi. SE (581 ft.) SERVCO HEATING & AIR COND., INC. 945 S 300 W, SALT LAKE CITY, UT 84101 96 16 SEMSARCH UTD056090277 Lower (4,229 ft.) 0.12 mi. W (634 ft.) GALIGHER ASH CO.800 S 440 WEST, SALT LAKE CITY, UT 84110 97 16 RUST 4001458 Lower (4,229 ft.) 0.12 mi. W (634 ft.) BGA INTERNATIONAL 440 W 800 S, SALT LAKE CITY, UT 84110 98 15 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 16 RCRAGR08 UTD056090277 Lower (4,229 ft.) 0.12 mi. W (634 ft.) WEIR SPECIALTY PUMPS 440 WEST 800 SOUTH, SALT LAKE CITY, UT 84110 99 17 RUST 4001651 Equal (4,232 ft.) 0.12 mi. S (634 ft.) DAVID ORR/JEFF LYONS 929 S RIO GRANDE ST, SALT LAKE CITY, UT 84101 101 17 LUST 4001651LUST Equal (4,232 ft.) 0.12 mi. S (634 ft.) DAVID ORR/JEFF LYONS 929 S RIO GRANDE ST, SALT LAKE CITY, UT 84101 102 18 RCRAGR08 UTR000005249 Lower (4,229 ft.) 0.13 mi. NE (686 ft.) BESTWAY PRODUCTS CO. 333 WEST 700 SOUTH, SALT LAKE CITY, UT 84101 103 19 RUST 4000547 Lower (4,231 ft.) 0.14 mi. SE (739 ft.) RICCI INVESTMENT CO #5 208 W 900 S, SALT LAKE CITY, UT 84101 105 19 RUST 4002054 Lower (4,231 ft.) 0.14 mi. SE (739 ft.) ALLEY RIGHT-OF- WAY BY METRO OIL 208 W 900 S, SALT LAKE CITY, UT 84101 107 19 LUST 4000547LUST Lower (4,231 ft.) 0.14 mi. SE (739 ft.) RICCI INVESTMENT CO #5 208 W 900 S, SALT LAKE CITY, UT 84101 108 20 CERCLIS UTD988066155 Lower (4,229 ft.) 0.15 mi. NE (792 ft.) OLD SALT LAKE CITY FIRE STATION 2ND WEST 7TH SOUTH, SALT LAKE CITY, UT 84101 109 20 SEMSARCH UTD988066155 Lower (4,229 ft.) 0.15 mi. NE (792 ft.) OLD SALT LAKE CITY FIRE STATION 2ND WEST 7TH SOUTH, SALT LAKE CITY, UT 84101 110 21 RUST 4001222 Equal (4,232 ft.) 0.15 mi. SE (792 ft.) VOGUE CLEANING 906 S 200 W, SALT LAKE CITY, UT 84101 111 21 LUST 4001222LUST Equal (4,232 ft.) 0.15 mi. SE (792 ft.) VOGUE CLEANING 906 S 200 W, SALT LAKE CITY, UT 84101 113 22 CERCLIS UTD056090277 Lower (4,229 ft.) 0.18 mi. W (950 ft.) GALIGHER ASH CO.800 SOUTH 440 WEST, SALT LAKE CITY, UT 84110 114 23 RUST 4001100 Lower (4,229 ft.) 0.2 mi. SW (1056 ft.) SALT LAKE CITY- 9TH SOUTH SEC. 900 S 500 W, SALT LAKE CITY, UT 84116 115 23 LUST 4001100LUST Lower (4,229 ft.) 0.2 mi. SW (1056 ft.) SALT LAKE CITY- 9TH SOUTH SEC. 900 S 500 W, SALT LAKE CITY, UT 84116 117 24 RUST 4000658 Lower (4,229 ft.) 0.2 mi. S (1056 ft.) NORM BULLOCK TOWING COMPANY 435 W FAYETTE AVE ( 965 S ), SALT LAKE CITY, UT 84115 118 24 LUST 4000658LUST Lower (4,229 ft.) 0.2 mi. S (1056 ft.) NORM BULLOCK TOWING COMPANY 435 W FAYETTE AVE ( 965 S ), SALT LAKE CITY, UT 84115 119 25 RUST 4000203 Lower (4,231 ft.) 0.2 mi. S (1056 ft.) CUMMINS ROCKY MOUNTAIN LLC 1030 S 300 W, SALT LAKE CITY, UT 84101 120 25 VCP VCP-C039 Lower (4,231 ft.) 0.2 mi. S (1056 ft.) CUMMINS INTERMOUNTAIN - SLC 1030 SOUTH 300 WEST, SALT LAKE CITY, UT 84125 124 25 LUST 4000203LUST Lower (4,231 ft.) 0.21 mi. S (1109 ft.) CUMMINS ROCKY MOUNTAIN LLC 1030 S 300 W, SALT LAKE CITY, UT 84101 125 26 LUST 4000550LUST Lower (4,229 ft.) 0.22 mi. S (1162 ft.) CRYSTAL TRUCKING COMPANY 451 W FAYETTE AVE ( 965 S ), SALT LAKE CITY, UT 84115 126 27 RUST 4001311 Lower (4,229 ft.) 0.25 mi. NW (1320 ft.) C.W. SILVER CO., INC. 535 W 700 S, SALT LAKE CITY, UT 84101 127 27 RUST 4001563 Lower (4,229 ft.) 0.22 mi. NW (1162 ft.) SILCO LTD.501 W 700 S ;;, SALT LAKE CITY, UT 84101 128 27 LUST 4001563LUST Lower (4,229 ft.) 0.22 mi. NW (1162 ft.) SILCO LTD.501 W 700 S ;;, SALT LAKE CITY, UT 84101 129 28 RUST 4002025 Equal (4,232 ft.) 0.22 mi. E (1162 ft.) JACKS PROPERTY 156 W 900 S, SALT LAKE CITY, UT 84111 130 28 LUST 4002025LUST Equal (4,232 ft.) 0.22 mi. E (1162 ft.) JACKS PROPERTY 156 W 900 S, SALT LAKE CITY, UT 84111 132 29 RUST 4001172 Equal (4,232 ft.) 0.22 mi. SW (1162 ft.) PIONEER WHOLESALE 920 S 500 W, SALT LAKE CITY, UT 84110 133 16 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 29 LUST 4001172LUST Equal (4,232 ft.) 0.22 mi. SW (1162 ft.) PIONEER WHOLESALE 920 S 500 W, SALT LAKE CITY, UT 84110 135 30 RUST 4002053 Lower (4,229 ft.) 0.23 mi. W (1214 ft.) ROCKMONT INDUSTRIAL CORP. 774 S 500 W, SALT LAKE CITY, UT 84101 136 31 RUST 4002206 Lower (4,229 ft.) 0.24 mi. SW (1267 ft.) NICHOLAS & COMPANY FOOD 500 W FAYETTE AVENUE ( 965 S.), SALT LAKE CITY, UT 84115 137 31 LUST 4002206LUST Lower (4,229 ft.) 0.24 mi. SW (1267 ft.) NICHOLAS & COMPANY FOOD 500 W FAYETTE AVENUE ( 965 S.), SALT LAKE CITY, UT 84115 138 32 RUST 4001733 Higher (4,236 ft.) 0.26 mi. E (1373 ft.) RICK WARNER FORD 730 S WEST TEMPLE, SALT LAKE CITY, UT 84101 139 32 LUST 4001733LUST Higher (4,236 ft.) 0.26 mi. E (1373 ft.) RICK WARNER FORD 730 S WEST TEMPLE, SALT LAKE CITY, UT 84101 140 33 LUST 4002023LUST Equal (4,232 ft.) 0.27 mi. E (1426 ft.) SATURN OF SALT LAKE 770 S WEST TEMPLE, SALT LAKE CITY, UT 84101 141 34 LUST 4000941LUST Higher (4,235 ft.) 0.29 mi. E (1531 ft.) CNG AMERICA SLC 110 W 900 S, SALT LAKE CITY, UT 84101 142 35 LUST 4001045LUST Equal (4,232 ft.) 0.29 mi. E (1531 ft.) 7-ELEVEN 1851-26282 111 W 800 S, SALT LAKE CITY, UT 84101 143 36 VCP VCP-C004 Lower (4,229 ft.) 0.29 mi. NW (1531 ft.) C. W. SILVER 550 AND 552 WEST 700 SOUTH, SALT LAKE CITY, UT 84101 144 37 BF PRE8 Equal (4,232 ft.) 0.29 mi. NE (1531 ft.) SALT LAKE CITY GATEWAY PILOT PROJECT NORTH TEMPLE ON NORTH, 300 WEST ON EAST, I15 ON WEST, 900 SOUTH STREET ON SOUTH, SALT LAKE CITY, UT 84111 145 38 LUST 4000641LUST Lower (4,229 ft.) 0.31 mi. N (1637 ft.) N.P. METTOME CO.465 W 600 S, SALT LAKE CITY, UT 84101 146 39 LUST 4000270LUST Equal (4,232 ft.) 0.32 mi. NW (1690 ft.) 5TH & 6TH STREET BUSINESS CENTER 537 W 600 S, SALT LAKE CITY, UT 84110 147 40 LUST 4000520LUST Equal (4,232 ft.) 0.33 mi. W (1742 ft.) LONE STAR INDUSTRIES, INC. 615 W 800 S, SALT LAKE CITY, UT 84104 148 41 LUST 4002065LUST Equal (4,232 ft.) 0.33 mi. N (1742 ft.) THRILLER CAR COMPANY 346 W 600 S, SALT LAKE CITY, UT 84110 149 42 LUST 4000974LUST Higher (4,236 ft.) 0.34 mi. NE (1795 ft.) SUPER SONIC CAR WASH 672 S WEST TEMPLE, SALT LAKE CITY, UT 84101 150 43 LUST 4002278LUST Equal (4,232 ft.) 0.34 mi. E (1795 ft.) FORMER COCA COLA BOTTLING 875 S WEST TEMPLE, SALT LAKE CITY, UT 84101 151 44 LUST 4000421LUST Higher (4,236 ft.) 0.34 mi. NE (1795 ft.) MAVERIK #331 615 S 200 W, SALT LAKE CITY, UT 84101 152 45 LUST 4000047LUST Higher (4,236 ft.) 0.38 mi. E (2006 ft.) RICK WARNER CHRYSLER PLYMOUTH 777 S WEST TEMPLE, SALT LAKE CITY, UT 84101 153 46 LUST 4001879LUST Higher (4,236 ft.) 0.4 mi. E (2112 ft.) VACANT PROPERTY 50 W 900 S, SALT LAKE CITY, UT 84111 154 47 LUST 4001237LUST Higher (4,236 ft.) 0.4 mi. E (2112 ft.) WAGSTAFF'S TOYOTA 84 W 700 S, SALT LAKE CITY, UT 84101 155 48 LUST 4000940LUST Higher (4,239 ft.) 0.41 mi. NE (2165 ft.) BASIN MARKETS #104 105 W 600 S, SALT LAKE CITY, UT 84101 156 49 LUST 4001539LUST Lower (4,229 ft.) 0.41 mi. SW (2165 ft.) UNISOURCE 1000 S 500 W, SALT LAKE CITY, UT 84101 157 50 VCP VCP-C009 Lower (4,229 ft.) 0.42 mi. W (2218 ft.) VAN WATERS AND ROGERS 650 WEST 800 SOUTH, SALT LAKE CITY, UT 84104 158 51 LUST 4000654LUST Equal (4,232 ft.) 0.42 mi. N (2218 ft.) NEWSPAPER AGENCY CORP. GARAGE 520 GALE ST, SALT LAKE CITY, UT 84101 159 17 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 52 LUST 4001676LUST Higher (4,239 ft.) 0.43 mi. NE (2270 ft.) OLD RICK WARNER FORD SITE 47 W 600 S, SALT LAKE CITY, UT 84101 160 53 LUST 4000785LUST Higher (4,235 ft.) 0.43 mi. SE (2270 ft.) RAVARINO PRODUCE COMPANY, INC. 1031 S WEST TEMPLE, SALT LAKE CITY, UT 84101 161 54 LUST 4000365LUST Lower (4,229 ft.) 0.43 mi. NW (2270 ft.) HARRY L. YOUNG & SONS 542 W 600 S, SALT LAKE CITY, UT 84101 162 55 CERCLIS UTN000802626 Lower (4,229 ft.) 0.44 mi. SE (2323 ft.) RETEP 216 WEST PAXTON AVENUE PLUME 216 WEST PAXTON AVE., SALT LAKE CITY, UT 84101 163 55 SEMS UTN000802626 Lower (4,229 ft.) 0.44 mi. SE (2323 ft.) RETEP 216 W. PAXTON AVE. PLUME 216 W. PAXTON AVE., SALT LAKE CITY, UT 84101 164 56 LUST 4002244LUST Higher (4,236 ft.) 0.44 mi. N (2323 ft.) ALBERTO'S MOLCASALSA 511 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 165 57 LUST 4002214LUST Lower (4,229 ft.) 0.46 mi. N (2429 ft.) FORMER A-1 PIONEER STORAGE 471 W 500 S, SALT LAKE CITY, UT 84113 166 58 CERCLIS UTD980635585 Lower (4,229 ft.) 0.47 mi. SW (2482 ft.) MORRIS P. KIRK PLT CRD 977 SOUTH 700 WEST, SALT LAKE CITY, UT 84104 167 58 SEMSARCH UTD980635585 Lower (4,229 ft.) 0.47 mi. SW (2482 ft.) MORRIS P. KIRK PLT/CRD 977 SOUTH 700 WEST, SALT LAKE CITY, UT 84104 168 59 VCP VCP-C060 Lower (4,229 ft.) 0.49 mi. S (2587 ft.) 300 WEST TOWN CENTER 1200 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 169 59 LUST 4000696LUST Lower (4,229 ft.) 0.47 mi. S (2482 ft.) PETROLEUM EQUIPMENT CO. 1174 S 300 W, SALT LAKE CITY, UT 84101 173 60 LUST 4001587LUST Higher (4,236 ft.) 0.47 mi. SE (2482 ft.) BORDEN INC., MEADOW GOLD DAIRY 1030 S MAIN ST, SALT LAKE CITY, UT 84101 174 61 LUST 4000098LUST Higher (4,242 ft.) 0.48 mi. NE (2534 ft.) PHILLIPS 66 CO # 28025 179 W 500 S, SALT LAKE CITY, UT 84101 175 62 LUST 4001517LUST Equal (4,232 ft.) 0.48 mi. N (2534 ft.) OLD WHITFIELD TRANSPORTATION 414 W 500 S, SALT LAKE CITY, UT 84101 176 63 LUST 4001141LUST Lower (4,226 ft.) 0.48 mi. SW (2534 ft.) UNION POINT CONSTRUCTION COMPANY 1132 S 500 W, SALT LAKE CITY, UT 84101 177 64 LUST 4001898LUST Higher (4,239 ft.) 0.48 mi. E (2534 ft.) MASTER MUFFLER 690 S MAIN, SALT LAKE CITY, UT 84101 178 65 LUST 4000048LUST Equal (4,232 ft.) 0.48 mi. N (2534 ft.) A & Z PRODUCE CO 380 W 500 S, SALT LAKE CITY, UT 84110 179 66 LUST 4000514LUST Lower (4,229 ft.) 0.49 mi. NW (2587 ft.) ALL RESORT COACH INC. 549 W 500 S, SALT LAKE CITY, UT 84101 180 67 LUST 4001719LUST Higher (4,239 ft.) 0.49 mi. E (2587 ft.) LELIS TRANSMISSIONS 845 S MAIN, SALT LAKE CITY, UT 84111 181 67 LUST 4001420LUST Higher (4,239 ft.) 0.49 mi. E (2587 ft.) COMMERCIAL PROPANE 865 S MAIN ST, SALT LAKE CITY, UT 84111 182 68 LUST 4002343LUST Higher (4,249 ft.) 0.49 mi. N (2587 ft.) SHERATON HOTEL 150 WEST 500 SOUTH, SALT LAKE CITY, UT 84101 183 69 LUST 4001788LUST Lower (4,229 ft.) 0.5 mi. NW (2640 ft.) KIRBY WAREHOUSE 651 W 600 S, SALT LAKE CITY, UT 84115 184 70 LUST 4000138LUST Equal (4,232 ft.) 0.5 mi. SE (2640 ft.) CARLESON CADILLAC CO. INC. 1070 S MAIN ST, SALT LAKE CITY, UT 84101 185 18 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary Elevations are collected from the USGS 3D Elevation Program 1/3 arc-second (approximately 10 meters) layer hosted at the NGTOC. . Target Property Elevation: 4232 ft. NOTE: Standard environmental records are displayed in bold. EQUAL/HIGHER ELEVATION Map ID# Database Name Elevation Site Name Address Page # 3 NLRRCRAG 4,232 ft.SALT LAKE COLLISON REPAIR 362 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 59 3 RCRANGR08 4,232 ft.SALT LAKE CITY SHOPS 350 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 61 3 RCRANGR08 4,232 ft.SALT LAKE COLLISON REPAIR 362 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 63 3 FRSUT 4,232 ft.SALT LAKE CITY SHOPS 350 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 65 9 RCRANGR08 4,232 ft.CITY WELDING & RADIATOR WORKS 259 WEST 900 SOUTH, SALT LAKE CITY, UT 84101 83 9 NLRRCRAG 4,232 ft.CITY WELDING & RADIATOR WORKS 259 WEST 9TH SOUTH, SALT LAKE CITY, UT 84101 85 10 RCRAGR08 4,232 ft.A&E ALTERNATOR AND STARTERS 264 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 87 13 VCP 4,232 ft.UTAH BARREL AND SCRAP - ARTSPACE 850 SOUTH 400 WEST AND 856 SOUTH 400 WEST, SALT LAKE CITY, UT 84101 92 17 RUST 4,232 ft.DAVID ORR/JEFF LYONS 929 S RIO GRANDE ST, SALT LAKE CITY, UT 84101 101 17 LUST 4,232 ft.DAVID ORR/JEFF LYONS 929 S RIO GRANDE ST, SALT LAKE CITY, UT 84101 102 19 RUST 4,231 ft.RICCI INVESTMENT CO #5 208 W 900 S, SALT LAKE CITY, UT 84101 105 19 RUST 4,231 ft.ALLEY RIGHT-OF-WAY BY METRO OIL 208 W 900 S, SALT LAKE CITY, UT 84101 107 19 LUST 4,231 ft.RICCI INVESTMENT CO #5 208 W 900 S, SALT LAKE CITY, UT 84101 108 21 RUST 4,232 ft.VOGUE CLEANING 906 S 200 W, SALT LAKE CITY, UT 84101 111 21 LUST 4,232 ft.VOGUE CLEANING 906 S 200 W, SALT LAKE CITY, UT 84101 113 25 RUST 4,231 ft.CUMMINS ROCKY MOUNTAIN LLC 1030 S 300 W, SALT LAKE CITY, UT 84101 120 25 VCP 4,231 ft.CUMMINS INTERMOUNTAIN - SLC 1030 SOUTH 300 WEST, SALT LAKE CITY, UT 84125 124 25 LUST 4,231 ft.CUMMINS ROCKY MOUNTAIN LLC 1030 S 300 W, SALT LAKE CITY, UT 84101 125 28 RUST 4,232 ft.JACKS PROPERTY 156 W 900 S, SALT LAKE CITY, UT 84111 130 28 LUST 4,232 ft.JACKS PROPERTY 156 W 900 S, SALT LAKE CITY, UT 84111 132 29 RUST 4,232 ft.PIONEER WHOLESALE 920 S 500 W, SALT LAKE CITY, UT 84110 133 29 LUST 4,232 ft.PIONEER WHOLESALE 920 S 500 W, SALT LAKE CITY, UT 84110 135 19 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 32 RUST 4,236 ft.RICK WARNER FORD 730 S WEST TEMPLE, SALT LAKE CITY, UT 84101 139 32 LUST 4,236 ft.RICK WARNER FORD 730 S WEST TEMPLE, SALT LAKE CITY, UT 84101 140 33 LUST 4,232 ft.SATURN OF SALT LAKE 770 S WEST TEMPLE, SALT LAKE CITY, UT 84101 141 34 LUST 4,235 ft.CNG AMERICA SLC 110 W 900 S, SALT LAKE CITY, UT 84101 142 35 LUST 4,232 ft.7-ELEVEN 1851-26282 111 W 800 S, SALT LAKE CITY, UT 84101 143 37 BF 4,232 ft.SALT LAKE CITY GATEWAY PILOT PROJECT NORTH TEMPLE ON NORTH, 300 WEST ON EAST, I15 ON WEST, 900 SOUTH STREET ON SOUTH, SALT LAKE CITY, UT 84111 145 39 LUST 4,232 ft.5TH & 6TH STREET BUSINESS CENTER 537 W 600 S, SALT LAKE CITY, UT 84110 147 40 LUST 4,232 ft.LONE STAR INDUSTRIES, INC.615 W 800 S, SALT LAKE CITY, UT 84104 148 41 LUST 4,232 ft.THRILLER CAR COMPANY 346 W 600 S, SALT LAKE CITY, UT 84110 149 42 LUST 4,236 ft.SUPER SONIC CAR WASH 672 S WEST TEMPLE, SALT LAKE CITY, UT 84101 150 43 LUST 4,232 ft.FORMER COCA COLA BOTTLING 875 S WEST TEMPLE, SALT LAKE CITY, UT 84101 151 44 LUST 4,236 ft.MAVERIK #331 615 S 200 W, SALT LAKE CITY, UT 84101 152 45 LUST 4,236 ft.RICK WARNER CHRYSLER PLYMOUTH 777 S WEST TEMPLE, SALT LAKE CITY, UT 84101 153 46 LUST 4,236 ft.VACANT PROPERTY 50 W 900 S, SALT LAKE CITY, UT 84111 154 47 LUST 4,236 ft.WAGSTAFF'S TOYOTA 84 W 700 S, SALT LAKE CITY, UT 84101 155 48 LUST 4,239 ft.BASIN MARKETS #104 105 W 600 S, SALT LAKE CITY, UT 84101 156 51 LUST 4,232 ft.NEWSPAPER AGENCY CORP. GARAGE 520 GALE ST, SALT LAKE CITY, UT 84101 159 52 LUST 4,239 ft.OLD RICK WARNER FORD SITE 47 W 600 S, SALT LAKE CITY, UT 84101 160 53 LUST 4,235 ft.RAVARINO PRODUCE COMPANY, INC. 1031 S WEST TEMPLE, SALT LAKE CITY, UT 84101 161 56 LUST 4,236 ft.ALBERTO'S MOLCASALSA 511 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 165 60 LUST 4,236 ft.BORDEN INC., MEADOW GOLD DAIRY 1030 S MAIN ST, SALT LAKE CITY, UT 84101 174 61 LUST 4,242 ft.PHILLIPS 66 CO # 28025 179 W 500 S, SALT LAKE CITY, UT 84101 175 62 LUST 4,232 ft.OLD WHITFIELD TRANSPORTATION 414 W 500 S, SALT LAKE CITY, UT 84101 176 64 LUST 4,239 ft.MASTER MUFFLER 690 S MAIN, SALT LAKE CITY, UT 84101 178 65 LUST 4,232 ft.A & Z PRODUCE CO 380 W 500 S, SALT LAKE CITY, UT 84110 179 67 LUST 4,239 ft.LELIS TRANSMISSIONS 845 S MAIN, SALT LAKE CITY, UT 84111 181 67 LUST 4,239 ft.COMMERCIAL PROPANE 865 S MAIN ST, SALT LAKE CITY, UT 84111 182 20 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 68 LUST 4,249 ft.SHERATON HOTEL 150 WEST 500 SOUTH, SALT LAKE CITY, UT 84101 183 70 LUST 4,232 ft.CARLESON CADILLAC CO. INC.1070 S MAIN ST, SALT LAKE CITY, UT 84101 185 LOWER ELEVATION Map ID# Database Name Elevation Site Name Address Page # 1 FRSUT 4,229 ft.FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84101 24 1 FRSUT 4,229 ft.SALT LAKE CITY FLEET YARD 850 SOUTH 300 WEST BLDG. NO. 3, SALT LAKE CITY, UT 84101 25 1 FRSUT 4,229 ft.US DRUG ENFORCEMENT ADMINISTRATION 850 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 26 1 FRSUT 4,229 ft.SALT LAKE CITY FLEET YARD 850 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 27 1 FRSUT 4,229 ft.SALT LAKE CITY CORPORATION FLEET YARD 325 W 800 S, SALT LAKE CITY, UT 84101 28 1 ICISNPDES 4,229 ft.SALT LAKE CITY FLEET YARD 850 SOUTH 300 WEST, SALT LAKE CITY, UT 29 1 ICISNPDES 4,229 ft.SALT LAKE CITY CORPORATION FLEET YARD 325 W 800 S, SALT LAKE CITY, UT 84101 31 1 NLRRCRAG 4,229 ft.SALT LAKE CITY MATERIAL 850 SOUTH 300 WEST BLDG. NO. 3, SALT LAKE CITY, UT 84101 33 1 NLRRCRAT 4,229 ft.SALT LAKE CITY FLEET MGMT 325 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 35 1 RCRAGR08 4,229 ft.SALT LAKE CITY FLEET MGMT 325 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 37 1 RCRANGR08 4,229 ft.US DRUG ENFORCEMENT ADMINISTRATION 850 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 39 1 RCRANGR08 4,229 ft.SALT LAKE CITY MATERIAL 850 SOUTH 300 WEST BLDG. NO. 3, SALT LAKE CITY, UT 84101 41 1 BF 4,229 ft.FLEET MANAGEMENT YARD BROWNFIELDS PILOT PROJECT BETWEEN 900 SOUTH AND 800 SOUTH AND 300 WEST AND 400 WEST, SALT LAKE CITY, UT 84101 43 1 LUST 4,229 ft.FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 44 1 LUST 4,229 ft.FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 45 1 RUST 4,229 ft.FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 46 1 RUST 4,229 ft.FLEET MANAGEMENT YARD 325 W 800 S, SALT LAKE CITY, UT 84111 51 1 FRSUT 4,229 ft.SALT LAKE CITY CORPORATION FLEET YARD 325 WEST 800 SOUTH, SALT LAKE CITY, UT 84101 53 2 FRSUT 4,229 ft.NORMAN CO 312 WEST 800 SOUTH, SLC, UT 84101 54 2 LUST 4,229 ft.OLD GAS STATION SITE 800 S 300 W, SALT LAKE CITY, UT 84101 55 2 RUST 4,229 ft.OLD GAS STATION SITE 800 S 300 W, SALT LAKE CITY, UT 84101 56 2 FRSUT 4,229 ft.OLD GAS STATION SITE 800 S 300 W, SALT LAKE CITY, UT 84101 58 4 NLRRCRAG 4,229 ft.UTAH BARREL INC.370 WEST 900 SOUTH, SALT LAKE CITY, UT 84110 66 21 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 4 RCRANGR08 4,229 ft.UTAH BARREL INC.370 WEST 900 SOUTH, SALT LAKE CITY, UT 84110 68 4 FRSUT 4,229 ft.UTAH BARREL INC.370 WEST 900 SOUTH, SALT LAKE CITY, UT 84110 70 5 RUST 4,229 ft.OLD GAS STATION - PROJECT SITE #EA-028-92 879 S 300 W, SALT LAKE CITY, UT 84101 71 5 LUST 4,229 ft.OLD GAS STATION - PROJECT SITE #EA-028-92 879 S 300 W, SALT LAKE CITY, UT 84101 74 6 LUST 4,229 ft.DEVROOM'S GARAGE 777 S 300 W, SALT LAKE CITY, UT 84106 75 6 RUST 4,229 ft.GENE PENMAN 66 775 S 300 W, SALT LAKE CITY, UT 84101 76 6 RUST 4,229 ft.DEVROOM'S GARAGE 777 S 300 W, SALT LAKE CITY, UT 84106 78 6 LUST 4,229 ft.GENE PENMAN 66 775 S 300 W, SALT LAKE CITY, UT 84101 79 7 RCRANGR08 4,229 ft.ARO PICKLE FACTORY 741 SOUTH 400 WEST, SALT LAKE CITY, UT 84111 80 8 BF 4,229 ft.UTAH BARREL AND SCRAP 850 SOUTH 400 WEST, SALT LAKE CITY, UT 84111 82 11 RUST 4,229 ft.C/O METRO STEEL 401 W 900 S, SALT LAKE CITY, UT 84101 89 12 RUST 4,229 ft.WAREHOUSE 453 W 800 S, SALT LAKE CITY, UT 84101 91 14 RCRAGR08 4,229 ft.VENTURA'S CUSTOM AUTO PAINTING 372 WEST AMERICAN AVE., SALT LAKE CITY, UT 84101 94 15 RUST 4,229 ft.SERVCO HEATING & AIR COND., INC. 945 S 300 W, SALT LAKE CITY, UT 84101 96 16 SEMSARCH 4,229 ft.GALIGHER ASH CO.800 S 440 WEST, SALT LAKE CITY, UT 84110 97 16 RUST 4,229 ft.BGA INTERNATIONAL 440 W 800 S, SALT LAKE CITY, UT 84110 98 16 RCRAGR08 4,229 ft.WEIR SPECIALTY PUMPS 440 WEST 800 SOUTH, SALT LAKE CITY, UT 84110 99 18 RCRAGR08 4,229 ft.BESTWAY PRODUCTS CO.333 WEST 700 SOUTH, SALT LAKE CITY, UT 84101 103 20 CERCLIS 4,229 ft.OLD SALT LAKE CITY FIRE STATION 2ND WEST 7TH SOUTH, SALT LAKE CITY, UT 84101 109 20 SEMSARCH 4,229 ft.OLD SALT LAKE CITY FIRE STATION 2ND WEST 7TH SOUTH, SALT LAKE CITY, UT 84101 110 22 CERCLIS 4,229 ft.GALIGHER ASH CO.800 SOUTH 440 WEST, SALT LAKE CITY, UT 84110 114 23 RUST 4,229 ft.SALT LAKE CITY-9TH SOUTH SEC.900 S 500 W, SALT LAKE CITY, UT 84116 115 23 LUST 4,229 ft.SALT LAKE CITY-9TH SOUTH SEC.900 S 500 W, SALT LAKE CITY, UT 84116 117 24 RUST 4,229 ft.NORM BULLOCK TOWING COMPANY 435 W FAYETTE AVE ( 965 S ), SALT LAKE CITY, UT 84115 118 24 LUST 4,229 ft.NORM BULLOCK TOWING COMPANY 435 W FAYETTE AVE ( 965 S ), SALT LAKE CITY, UT 84115 119 26 LUST 4,229 ft.CRYSTAL TRUCKING COMPANY 451 W FAYETTE AVE ( 965 S ), SALT LAKE CITY, UT 84115 126 22 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 27 RUST 4,229 ft.C.W. SILVER CO., INC.535 W 700 S, SALT LAKE CITY, UT 84101 127 27 RUST 4,229 ft.SILCO LTD.501 W 700 S ;;, SALT LAKE CITY, UT 84101 128 27 LUST 4,229 ft.SILCO LTD.501 W 700 S ;;, SALT LAKE CITY, UT 84101 129 30 RUST 4,229 ft.ROCKMONT INDUSTRIAL CORP.774 S 500 W, SALT LAKE CITY, UT 84101 136 31 RUST 4,229 ft.NICHOLAS & COMPANY FOOD 500 W FAYETTE AVENUE ( 965 S.), SALT LAKE CITY, UT 84115 137 31 LUST 4,229 ft.NICHOLAS & COMPANY FOOD 500 W FAYETTE AVENUE ( 965 S.), SALT LAKE CITY, UT 84115 138 36 VCP 4,229 ft.C. W. SILVER 550 AND 552 WEST 700 SOUTH, SALT LAKE CITY, UT 84101 144 38 LUST 4,229 ft.N.P. METTOME CO.465 W 600 S, SALT LAKE CITY, UT 84101 146 49 LUST 4,229 ft.UNISOURCE 1000 S 500 W, SALT LAKE CITY, UT 84101 157 50 VCP 4,229 ft.VAN WATERS AND ROGERS 650 WEST 800 SOUTH, SALT LAKE CITY, UT 84104 158 54 LUST 4,229 ft.HARRY L. YOUNG & SONS 542 W 600 S, SALT LAKE CITY, UT 84101 162 55 CERCLIS 4,229 ft.RETEP 216 WEST PAXTON AVENUE PLUME 216 WEST PAXTON AVE., SALT LAKE CITY, UT 84101 163 55 SEMS 4,229 ft.RETEP 216 W. PAXTON AVE. PLUME 216 W. PAXTON AVE., SALT LAKE CITY, UT 84101 164 57 LUST 4,229 ft.FORMER A-1 PIONEER STORAGE 471 W 500 S, SALT LAKE CITY, UT 84113 166 58 CERCLIS 4,229 ft.MORRIS P. KIRK PLT CRD 977 SOUTH 700 WEST, SALT LAKE CITY, UT 84104 167 58 SEMSARCH 4,229 ft.MORRIS P. KIRK PLT/CRD 977 SOUTH 700 WEST, SALT LAKE CITY, UT 84104 168 59 VCP 4,229 ft.300 WEST TOWN CENTER 1200 SOUTH 300 WEST, SALT LAKE CITY, UT 84101 169 59 LUST 4,229 ft.PETROLEUM EQUIPMENT CO.1174 S 300 W, SALT LAKE CITY, UT 84101 173 63 LUST 4,226 ft.UNION POINT CONSTRUCTION COMPANY 1132 S 500 W, SALT LAKE CITY, UT 84101 177 66 LUST 4,229 ft.ALL RESORT COACH INC.549 W 500 S, SALT LAKE CITY, UT 84101 180 69 LUST 4,229 ft.KIRBY WAREHOUSE 651 W 600 S, SALT LAKE CITY, UT 84115 184 23 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110002262685 NAME: FLEET MANAGEMENT YARD LOCATION ADDRESS: 325 W 800 S SALT LAKE CITY, UT 841010000 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: FLEET MANAGEMENT YARD PROGRAM/S LISTED FOR THIS FACILITY CIM - UTAH - COMMON IDENTIFIER MECHANISM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) NO SIC DATA REPORTED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 24 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110005200665 NAME: SALT LAKE CITY FLEET YARD LOCATION ADDRESS: 850 SOUTH 300 WEST BLDG. NO. 3 SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: SALT LAKE CITY MATERIAL SALT LAKE CITY FLEET YARD PROGRAM/S LISTED FOR THIS FACILITY RCRAINFO - RESOURCE CONSERVATION AND RECOVERY ACT INFORMATION SYSTEM NPDES - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) 1629 - HEAVY CONSTRUCTION, NOT ELSEWHERE CLASSIFIED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) 237990 - OTHER HEAVY AND CIVIL ENGINEERING CONSTRUCTION. Back to Report Summary 25 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110031321889 NAME: US DRUG ENFORCEMENT ADMINISTRATION LOCATION ADDRESS: 850 SOUTH 300 WEST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: US DRUG ENFORCEMENT ADMINISTRATION PROGRAM/S LISTED FOR THIS FACILITY RCRAINFO - RESOURCE CONSERVATION AND RECOVERY ACT INFORMATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) NO SIC DATA REPORTED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 26 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110058285653 NAME: SALT LAKE CITY FLEET YARD LOCATION ADDRESS: 850 SOUTH 300 WEST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: SALT LAKE CITY FLEET YARD PROGRAM/S LISTED FOR THIS FACILITY NPDES - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) 1629 - HEAVY CONSTRUCTION, NOT ELSEWHERE CLASSIFIED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) 237990 - OTHER HEAVY AND CIVIL ENGINEERING CONSTRUCTION. Back to Report Summary 27 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110041915265 NAME: SALT LAKE CITY CORPORATION FLEET YARD LOCATION ADDRESS: 325 W 800 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: SALT LAKE CITY CORPORATION FLEET YARD PROGRAM/S LISTED FOR THIS FACILITY NPDES - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) 4212 - LOCAL TRUCKING WITHOUT STORAGE NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) 484110 - GENERAL FREIGHT TRUCKING, LOCAL. 484110 - GENERAL FREIGHT TRUCKING, LOCAL. Back to Report Summary 28 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION NPDES ID: UTG070539INPDES FACILITY #: 110005200665 NAME: SALT LAKE CITY FLEET YARD PHYSICAL ADDRESS: 850 SOUTH 300 WEST SALT LAKE CITY UT NOT REPORTED COUNTY: SALT LAKE FACILITY TYPE: PRIVATELY OWNED FACILITY IMPAIRED WATERS: NOT REPORTED STANDARD INDUSTRIAL CLASSIFICATION 1629-HEAVY CONSTRUCTION PERMITS FACILITY TYPE INDICATOR: NON-POTABLE WATER PERMIT TYPE: GENERAL PERMIT COVERED FACILITY MAJOR MINOR FACILITY: MINOR DISCHARGER PERMIT STATUS: TERMINATED WATER BODY: STORM DRAIN TO JORDAN RIVER PERMIT NAME: SALT LAKE CITY CORPORATION AGENCY TYPE: STATE ORIGINAL ISSUE DATE: 3/1/2014 ISSUE DATE: 3/1/2014 ISSUING AGENCY: UTAH DIVISION OF WATER QUALITY EFFECTIVE DATE: 3/1/2014 EXPIRATION DATE: 4/30/2014 RETIREMENT DATE: NOT REPORTED TERMINATION DATE: 6/24/2014 PERMIT COMPLIANCE STATUS: YES PERMIT SUBJECT TO DMR RUN: YES REPORTABLE NONCOMPLIANCE TRACKING IS ON: YES INSPECTIONS - NO INSPECTIONS REPORTED - HISTORIC COMPLIANCE HISTORIC NON-COMPLIANCE QUARTER (YYYYQ): 20143 HISTORIC NON-COMPLIANCE: UNDETERMINED QNCR STATUS - INSUFFICIENT DATA, OR PERMITEE IS A MINOR DISCHARGER NOT SUBJECT TO MANDATORY REPORTING NUMBER OF E90 VIOLATIONS: 0 NUMBER OF COMPLIANCE SCHEDULE VIOLATIONS: 0 NUMBER OF SINGLE EVENT VIOLATIONS: 0 NUMBER OF PERMIT SCHEDULE VIOLATIONS: 0 HISTORIC NON-COMPLIANCE QUARTER (YYYYQ): 20144 HISTORIC NON-COMPLIANCE: UNDETERMINED QNCR STATUS - INSUFFICIENT DATA, OR PERMITEE IS A MINOR DISCHARGER NOT SUBJECT TO MANDATORY REPORTING 29 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) NUMBER OF E90 VIOLATIONS: 0 NUMBER OF COMPLIANCE SCHEDULE VIOLATIONS: 0 NUMBER OF SINGLE EVENT VIOLATIONS: 0 NUMBER OF PERMIT SCHEDULE VIOLATIONS: 0 SINGLE EVENT VIOLATIONS - NO SINGLE EVENT VIOLATIONS REPORTED - FORMAL ENFORCEMENT ACTIONS - NO FORMAL ENFORCEMENT ACTIONS REPORTED - EFFLUENT VIOLATIONS - NOT REPORTED - EFFLUENT VIOLATIONS contd.. - NOT REPORTED - EFFLUENT VIOLATIONS contd.. - NOT REPORTED - Back to Report Summary 30 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION NPDES ID: UTR000937INPDES FACILITY #: 110005201478 NAME: SALT LAKE CITY CORPORATION FLEET YARD PHYSICAL ADDRESS: 325 W 800 S SALT LAKE CITY UT 84101 COUNTY: SALT LAKE FACILITY TYPE: MUNICIPALITY IMPAIRED WATERS: NOT REPORTED STANDARD INDUSTRIAL CLASSIFICATION 4212-LOCAL TRUCKING, WITHOUT STORAGE PERMITS FACILITY TYPE INDICATOR: NON-POTABLE WATER PERMIT TYPE: GENERAL PERMIT COVERED FACILITY MAJOR MINOR FACILITY: MINOR DISCHARGER PERMIT STATUS: TERMINATED WATER BODY: JORDAN RIVER PERMIT NAME: SALT LAKE CITY CORPORATION FLEET MANAGEMENT AGENCY TYPE: STATE ORIGINAL ISSUE DATE: 7/1/2009 ISSUE DATE: 7/1/2009 ISSUING AGENCY: DIVISION OF WATER QUALITY EFFECTIVE DATE: 7/1/2009 EXPIRATION DATE: 12/31/2013 RETIREMENT DATE: NOT REPORTED TERMINATION DATE: 10/7/2013 PERMIT COMPLIANCE STATUS: YES PERMIT SUBJECT TO DMR RUN: YES REPORTABLE NONCOMPLIANCE TRACKING IS ON: YES INSPECTIONS MONITOR TYPE: OVERSIGHT LEAD AGENCY: STATE ACTUAL BEGIN DATE: 09/28/2011 ACTUAL END DATE: 09/28/2011 HISTORIC COMPLIANCE HISTORIC NON-COMPLIANCE QUARTER (YYYYQ): 20141 HISTORIC NON-COMPLIANCE: UNDETERMINED QNCR STATUS - INSUFFICIENT DATA, OR PERMITEE IS A MINOR DISCHARGER NOT SUBJECT TO MANDATORY REPORTING NUMBER OF E90 VIOLATIONS: 0 NUMBER OF COMPLIANCE SCHEDULE VIOLATIONS: 0 NUMBER OF SINGLE EVENT VIOLATIONS: 0 NUMBER OF PERMIT SCHEDULE VIOLATIONS: 0 31 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) SINGLE EVENT VIOLATIONS - NO SINGLE EVENT VIOLATIONS REPORTED - FORMAL ENFORCEMENT ACTIONS - NO FORMAL ENFORCEMENT ACTIONS REPORTED - EFFLUENT VIOLATIONS - NOT REPORTED - EFFLUENT VIOLATIONS contd.. - NOT REPORTED - EFFLUENT VIOLATIONS contd.. - NOT REPORTED - Back to Report Summary 32 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD980959480 OWNER TYPE: PRIVATE NAME: SALT LAKE CITY MATERIAL OWNER NAME: SALT LAKE CITY CORP. ADDRESS: 850 SOUTH 300 WEST BLDG. NO. 3 OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: LAURENCE GALLOWAY CONTACT ADDRESS: 850 SOUTH 300 WEST BLDG. NO. 3 SALT LAKE CITY UT 84101 CONTACT PHONE: 801-535-6940 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/19/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: ED DEPUTY INSPECTOR - DSHW 05/19/2010 INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/19/2010 NAME: SALT LAKE CITY MATERIAL GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 04/07/1986 NAME: SALT LAKE CITY MATERIAL GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 06/14/2010 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/19/2010 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - 33 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) HAZARDOUS WASTE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F002 THE FOLLOWING SPENT HALOGENATED SOLVENTS: TETRACHLOROETHYLENE, METHYLENE CHLORIDE,TRICHLOROETHYLENE, 1,1,1-TRICHLOROETHANE,CHLOROBENZENE, 1,1,2-TRICHLORO-1,2,2- TRIFLUOROETHANE, ORTHO-DICHLOROBENZENE, TRICHLOROFLUOROMETHANE, AND 1,1,2, TRICHLOROETHANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES YES NOT REPORTED IMPLEMENTER LAMPS YES NOT REPORTED IMPLEMENTER PESTICIDES YES NOT REPORTED IMPLEMENTER MERCURY CONTAINING EQUIPMENT YES NOT REPORTED IMPLEMENTER CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 34 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD981544364 OWNER TYPE: PRIVATE NAME: SALT LAKE CITY FLEET MGMT OWNER NAME: SALT LAKE CITY CORP ADDRESS: 325 WEST 800 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: J. DENNIS CONTACT ADDRESS: P.O. BOX 4100 SALT LAKE CITY UT 84110 CONTACT PHONE: 801-525-6921 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/19/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: MARK VALENTINE SERVICE MANAGER 05/19/2010 GUY A FAIETTE ANALYST 03/30/1992 INDUSTRY CLASSIFICATION (NAICS) 811111 - GENERAL AUTOMOTIVE REPAIR 811118 - OTHER AUTOMOTIVE MECHANICAL AND ELECTRICAL REPAIR AND MAINTENANCE 811121 - AUTOMOTIVE BODY, PAINT, AND INTERIOR REPAIR AND MAINTENANCE 811198 - ALL OTHER AUTOMOTIVE REPAIR AND MAINTENANCE SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/19/2010 NAME: SALT LAKE CITY FLEET MGMT GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 03/30/1992 NAME: SALT LAKE CITY CORP. FLEET MANAGEMENT GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 10/17/1986 NAME: SALT LAKE CITY FLEET MGMT GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR LAST UPDATED DATE: 06/14/2013 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO 35 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT) FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/19/2010 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D000 D001 IGNITABLE WASTE D009 MERCURY UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES NO NOT REPORTED NOTIFICATION LAMPS NO NOT REPORTED NOTIFICATION PESTICIDES NO NOT REPORTED NOTIFICATION MERCURY CONTAINING EQUIPMENT NO NOT REPORTED NOTIFICATION CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 36 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD981544364 OWNER TYPE: PRIVATE NAME: SALT LAKE CITY FLEET MGMT OWNER NAME: SALT LAKE CITY CORP ADDRESS: 325 WEST 800 SOUTH OPERATOR TYPE: MUNICIPAL SALT LAKE CITY, UT 84101 OPERATOR NAME: SALT LAKE CITY FLEET MGMT CONTACT NAME: JOHN JENNINGS CONTACT ADDRESS: P.O. BOX 145542 SALT LAKE CITY UT 84114 CONTACT PHONE: 8015356918 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/19/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: MARK VALENTINE SERVICE MANAGER 05/19/2010 GUY A FAIETTE ANALYST 03/30/1992 INDUSTRY CLASSIFICATION (NAICS) 811111 - GENERAL AUTOMOTIVE REPAIR 811118 - OTHER AUTOMOTIVE MECHANICAL AND ELECTRICAL REPAIR AND MAINTENANCE 811121 - AUTOMOTIVE BODY, PAINT, AND INTERIOR REPAIR AND MAINTENANCE 811198 - ALL OTHER AUTOMOTIVE REPAIR AND MAINTENANCE SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/19/2010 NAME: SALT LAKE CITY FLEET MGMT GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 03/30/1992 NAME: SALT LAKE CITY CORP. FLEET MANAGEMENT GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 10/17/1986 NAME: SALT LAKE CITY FLEET MGMT GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR LAST UPDATED DATE: 06/14/2013 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO 37 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/19/2010 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D000 D001 IGNITABLE WASTE D009 MERCURY UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES NO NOT REPORTED NOTIFICATION LAMPS NO NOT REPORTED NOTIFICATION PESTICIDES NO NOT REPORTED NOTIFICATION MERCURY CONTAINING EQUIPMENT NO NOT REPORTED NOTIFICATION CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 38 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD988071908 OWNER TYPE: PRIVATE NAME: US DRUG ENFORCEMENT ADMINISTRATION OWNER NAME: US GOVERNMENT ADDRESS: 850 SOUTH 300 WEST OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: DREW-R MOREN CONTACT ADDRESS: 850 SOUTH 300 WEST SALT LAKE CITY UT 84101 CONTACT PHONE: 8015244155 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 02/22/2007 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 02/22/2007 NAME: US DRUG ENFORCEMENT ADMINISTRATION GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 07/15/1991 NAME: US DRUG ENFORCEMENT ADMINISTRATION GENERATOR CLASSIFICATION: NOT A GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 09/16/2014 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS - NO EVALUATIONS REPORTED - VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D001 IGNITABLE WASTE 39 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 40 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD980959480 OWNER TYPE: PRIVATE NAME: SALT LAKE CITY MATERIAL OWNER NAME: SALT LAKE CITY CORP. ADDRESS: 850 SOUTH 300 WEST BLDG. NO. 3 OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: LAURENCE GALLOWAY CONTACT ADDRESS: 850 SOUTH 300 WEST BLDG. NO. 3 SALT LAKE CITY UT 84101 CONTACT PHONE: 8015356940 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/19/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: ED DEPUTY INSPECTOR - DSHW 05/19/2010 INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/19/2010 NAME: SALT LAKE CITY MATERIAL GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 04/07/1986 NAME: SALT LAKE CITY MATERIAL GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 06/14/2010 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/19/2010 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - 41 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) HAZARDOUS WASTE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F002 THE FOLLOWING SPENT HALOGENATED SOLVENTS: TETRACHLOROETHYLENE, METHYLENE CHLORIDE,TRICHLOROETHYLENE, 1,1,1-TRICHLOROETHANE,CHLOROBENZENE, 1,1,2-TRICHLORO-1,2,2- TRIFLUOROETHANE, ORTHO-DICHLOROBENZENE, TRICHLOROFLUOROMETHANE, AND 1,1,2, TRICHLOROETHANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES YES NOT REPORTED IMPLEMENTER LAMPS YES NOT REPORTED IMPLEMENTER PESTICIDES YES NOT REPORTED IMPLEMENTER MERCURY CONTAINING EQUIPMENT YES NOT REPORTED IMPLEMENTER CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 42 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: PRE14 DERR ID: PRE14 FACILITY NAME: FLEET MANAGEMENT YARD BROWNFIELDS PILOT PROJECT ADDRESS: BETWEEN 900 SOUTH AND 800 SOUTH AND 300 WEST AND 400 WEST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE SITE TYPE: BROWNFIELDS PROJECT - PRE14 PROJECT MANAGER: [PHILLIP (PHIL) GREER] CONTACT PHONE: 8015364100 PROJECT DESCRIPTION: NOT REPORTED Back to Report Summary 43 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000835LUST FACILITY ID: 4000835 FACILITY NAME: FLEET MANAGEMENT YARD ADDRESS: 325 W 800 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: SALT LAKE CITY FLEET MANAGEMENT ADDRESS: 1990 W 500 S SALT LAKE CITY, UT 84104 FACILITY DETAILS PROJECT MANAGER: HONG LEI TAO NOTIFICATION DATE: 7/15/1993 CLOSED DATE: NOT REPORTED CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: OTHER: UPGRADE INVESTIGATION CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: OTHER: UPGRADE INVESTIGATION Back to Report Summary 44 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001789LUST FACILITY ID: 4001789 FACILITY NAME: FLEET MANAGEMENT YARD ADDRESS: 325 W 800 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: SALT LAKE CITY FLEET MANAGEMENT ADDRESS: 1990 W 500 S SALT LAKE CITY, UT 84104 FACILITY DETAILS PROJECT MANAGER: [ROCKY STONESTREET] NOTIFICATION DATE: 3/28/1991 CLOSED DATE: 12/4/1992 CAUSE AND RELEASE CAUSE OF RELEASE: SPILL/OVERFILL SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: OTHER: FAILED TRACER TEST CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: TTT, REMOVAL, 8015 M, 413.1 Back to Report Summary 45 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000835 FACILITY ID: 3645 FACILITY NAME: FLEET MANAGEMENT YARD ADDRESS: 325 W 800 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: SALT LAKE CITY FLEET MANAGEMENT ADDRESS: 1990 W 500 S SALT LAKE CITY, UT 84104 OWNER PHONE: (801) 535-6904 TOTAL TANK: 10 CLOSED TANK: 10 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: CURRENTLY IN USE SUBSTANCE: DIESEL TANK CAPACITY: 10000 LAST USE: NOT REPORTED DATE CLOSED: NOT REPORTED CLOSURE STATUS: NOT REPORTED DATE INSTALLED: 1/1/1987 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: YES ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: CURRENTLY IN USE SUBSTANCE: DIESEL TANK CAPACITY: 10000 LAST USE: NOT REPORTED DATE CLOSED: NOT REPORTED CLOSURE STATUS: NOT REPORTED DATE INSTALLED: 1/1/1987 46 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: YES ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: CURRENTLY IN USE SUBSTANCE: GASOLINE TANK CAPACITY: 10000 LAST USE: NOT REPORTED DATE CLOSED: NOT REPORTED CLOSURE STATUS: NOT REPORTED DATE INSTALLED: 1/1/1987 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: OTHER PST FUND: YES ----------------------- TANK ID: 4 ALTERNATIVE TANK ID: 4 STATUS: CURRENTLY IN USE SUBSTANCE: GASOLINE TANK CAPACITY: 10000 LAST USE: NOT REPORTED DATE CLOSED: NOT REPORTED CLOSURE STATUS: NOT REPORTED DATE INSTALLED: 1/1/1987 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE 47 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: YES ----------------------- TANK ID: 5 ALTERNATIVE TANK ID: 5 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 12000 LAST USE: 1/1/1987 DATE CLOSED: 1/1/1987 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 2/11/1966 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 6 ALTERNATIVE TANK ID: 6 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 12000 LAST USE: 1/1/1987 DATE CLOSED: 1/1/1987 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 2/11/1966 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER 48 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) PST FUND: NO ----------------------- TANK ID: 7 ALTERNATIVE TANK ID: 7 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 12000 LAST USE: 1/1/1987 DATE CLOSED: 1/1/1987 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 2/11/1966 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 8 ALTERNATIVE TANK ID: 8 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 12000 LAST USE: 1/1/1987 DATE CLOSED: 1/1/1987 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 2/11/1974 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 9 ALTERNATIVE TANK ID: 9 49 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 12000 LAST USE: 1/1/1987 DATE CLOSED: 1/1/1987 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 2/11/1974 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST COMPLIANCE DATE: 06/01/11 CITATION DESCRIPTION: NOTIFICATION AND UPDATE OF TANKS AND FACILITY ----------------------- COMPLIANCE DATE: 06/01/11 CITATION DESCRIPTION: FAILURE TO MONITOR TANKS AT LEAST EVERY 30 DAYS, IF APPROPRIATE. ----------------------- COMPLIANCE DATE: 06/01/11 CITATION DESCRIPTION: FAILURE TO PERFORM ANNUAL TEST OF AUTOMATIC LINE LEAK DETECTOR ----------------------- COMPLIANCE DATE: 06/01/11 CITATION DESCRIPTION: FAILURE TO PROVIDE ADEQUATE LINE TIGHTNESS TESTING SYSTEM FOR UNDERGROUND PIPING SYSTEM. Back to Report Summary 50 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001789 FACILITY ID: 4521 FACILITY NAME: FLEET MANAGEMENT YARD ADDRESS: 325 W 800 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: SALT LAKE CITY FLEET MANAGEMENT ADDRESS: 1990 W 500 S SALT LAKE CITY, UT 84104 OWNER PHONE: (801) 535-6904 TOTAL TANK: 3 CLOSED TANK: 3 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 550 LAST USE: 2/21/1991 DATE CLOSED: 12/19/1991 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: NO PIPING PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 550 LAST USE: 12/15/1998 DATE CLOSED: 12/21/1999 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 6/6/1985 51 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: NO PIPING PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: YES ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 550 LAST USE: 12/15/1998 DATE CLOSED: 1/21/1999 CLOSURE STATUS: TANK CLOSED IN PLACE DATE INSTALLED: 6/6/1985 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: NO PIPING PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: YES COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 52 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) MAP ID# 1 Distance from Property: 0 mi. (0 ft.) X Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110005201478 NAME: SALT LAKE CITY CORPORATION FLEET YARD LOCATION ADDRESS: 325 WEST 800 SOUTH SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: SALT LAKE CITY CORPORATION FLEET YARD SALT LAKE CITY FLEET MGMT PROGRAM/S LISTED FOR THIS FACILITY NPDES - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM RCRAINFO - RESOURCE CONSERVATION AND RECOVERY ACT INFORMATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) 4212 - LOCAL TRUCKING WITHOUT STORAGE NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) 811111 - GENERAL AUTOMOTIVE REPAIR. 484110 - GENERAL FREIGHT TRUCKING, LOCAL. 484110 - GENERAL FREIGHT TRUCKING, LOCAL. Back to Report Summary 53 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT) MAP ID# 2 Distance from Property: 0.02 mi. (106 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110057322026 NAME: NORMAN CO LOCATION ADDRESS: 312 WEST 800 SOUTH SLC, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: NORMAN CO PROGRAM/S LISTED FOR THIS FACILITY OSHA-IMIS - *DEFINITION NOT PROVIDED BY REPORTING AGENCY STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) 3599 - INDUSTRIAL AND COMMERCIAL MACHINERY AND EQUIPMENT, NOT ELSEWHERE CLASSIFIED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 54 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT) MAP ID# 2 Distance from Property: 0.01 mi. (53 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001922LUST FACILITY ID: 4001922 FACILITY NAME: OLD GAS STATION SITE ADDRESS: 800 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: FIRST INTERSTATE BANK OF UTAH NA ADDRESS: 3815 S WEST TEMPLE SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [DALE URBAN] NOTIFICATION DATE: 3/26/1993 CLOSED DATE: 2/22/1995 CAUSE AND RELEASE CAUSE OF RELEASE: SLT. TANK CORROSION, LEAK? SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: TANK REMOVAL, ODOR Back to Report Summary 55 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST) MAP ID# 2 Distance from Property: 0.01 mi. (53 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001922 FACILITY ID: 4646 FACILITY NAME: OLD GAS STATION SITE ADDRESS: 800 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: FIRST INTERSTATE BANK OF UTAH NA ADDRESS: 3815 S WEST TEMPLE SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 350-7128 TOTAL TANK: 3 CLOSED TANK: 3 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 8000 LAST USE: 6/22/1988 DATE CLOSED: 6/22/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 8000 LAST USE: 6/22/1988 DATE CLOSED: 6/22/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 56 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 8000 LAST USE: 6/22/1988 DATE CLOSED: 6/22/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 57 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 2 Distance from Property: 0.01 mi. (53 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110020108612 NAME: OLD GAS STATION SITE LOCATION ADDRESS: 800 S 300 W SALT LAKE CITY, UT 841012801 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: OLD GAS STATION SITE PROGRAM/S LISTED FOR THIS FACILITY CIM - UTAH - COMMON IDENTIFIER MECHANISM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) NO SIC DATA REPORTED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 58 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT) MAP ID# 3 Distance from Property: 0.04 mi. (211 ft.) NE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: UTD053807087 OWNER TYPE: PRIVATE NAME: SALT LAKE COLLISON REPAIR OWNER NAME: DIANA L. JONES ADDRESS: 362 WEST 800 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: RICHARD-C JONES CONTACT ADDRESS: 362 WEST 800 SOUTH SALT LAKE CITY UT 84101 CONTACT PHONE: 801-534-1406 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 03/12/2008 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 03/12/2008 NAME: SALT LAKE COLLISON REPAIR GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 09/27/1985 NAME: SALT LAKE COLLISON REPAIR GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 03/13/2008 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 03/12/2008 CAV COMPLIANCE ASSISTANCE VISIT 03/12/1986 FCI FOCUSED COMPLIANCE INSPECTION VIOLATIONS 03/12/1986 262.A GENERATORS - GENERAL ENFORCEMENTS 59 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) 03/17/1986 120 WRITTEN INFORMAL HAZARDOUS WASTE D001 IGNITABLE WASTE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F002 THE FOLLOWING SPENT HALOGENATED SOLVENTS: TETRACHLOROETHYLENE, METHYLENE CHLORIDE,TRICHLOROETHYLENE, 1,1,1-TRICHLOROETHANE,CHLOROBENZENE, 1,1,2-TRICHLORO-1,2,2- TRIFLUOROETHANE, ORTHO-DICHLOROBENZENE, TRICHLOROFLUOROMETHANE, AND 1,1,2, TRICHLOROETHANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 60 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) MAP ID# 3 Distance from Property: 0.02 mi. (106 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: UTD980953574 OWNER TYPE: NOT REPORTED NAME: SALT LAKE CITY SHOPS OWNER NAME: NOT REPORTED ADDRESS: 350 WEST 800 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: NOT REPORTED CONTACT ADDRESS: NOT REPORTED CONTACT PHONE: NOT REPORTED NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 02/22/2007 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 02/22/2007 NAME: SALT LAKE CITY SHOPS GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 01/01/1980 NAME: SALT LAKE CITY SHOPS GENERATOR CLASSIFICATION: NOT A GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 09/16/2014 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 03/21/1985 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 01/24/1985 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - 61 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) HAZARDOUS WASTE - NO HAZARDOUS WASTE INFORMATION REPORTED - UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 62 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 3 Distance from Property: 0.04 mi. (211 ft.) NE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: UTD053807087 OWNER TYPE: PRIVATE NAME: SALT LAKE COLLISON REPAIR OWNER NAME: DIANA L. JONES ADDRESS: 362 WEST 800 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: RICHARD-C JONES CONTACT ADDRESS: 362 WEST 800 SOUTH SALT LAKE CITY UT 84101 CONTACT PHONE: 8015341406 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 03/12/2008 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 03/12/2008 NAME: SALT LAKE COLLISON REPAIR GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 09/27/1985 NAME: SALT LAKE COLLISON REPAIR GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 03/13/2008 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 03/12/2008 CAV COMPLIANCE ASSISTANCE VISIT 03/12/1986 FCI FOCUSED COMPLIANCE INSPECTION VIOLATIONS 03/12/1986 262.A GENERATORS - GENERAL ENFORCEMENTS 63 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) 03/17/1986 120 WRITTEN INFORMAL HAZARDOUS WASTE D001 IGNITABLE WASTE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F002 THE FOLLOWING SPENT HALOGENATED SOLVENTS: TETRACHLOROETHYLENE, METHYLENE CHLORIDE,TRICHLOROETHYLENE, 1,1,1-TRICHLOROETHANE,CHLOROBENZENE, 1,1,2-TRICHLORO-1,2,2- TRIFLUOROETHANE, ORTHO-DICHLOROBENZENE, TRICHLOROFLUOROMETHANE, AND 1,1,2, TRICHLOROETHANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 64 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 3 Distance from Property: 0.02 mi. (106 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION REGISTRY ID: 110031313380 NAME: SALT LAKE CITY SHOPS LOCATION ADDRESS: 350 WEST 800 SOUTH SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: SALT LAKE CITY SHOPS PROGRAM/S LISTED FOR THIS FACILITY RCRAINFO - RESOURCE CONSERVATION AND RECOVERY ACT INFORMATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) NO SIC DATA REPORTED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 65 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT) MAP ID# 4 Distance from Property: 0.02 mi. (106 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD035387737 OWNER TYPE: NOT REPORTED NAME: UTAH BARREL INC.OWNER NAME: NOT REPORTED ADDRESS: 370 WEST 900 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84110 OPERATOR NAME: NOT REPORTED CONTACT NAME: SANFORD PEPPER CONTACT ADDRESS: P O BOX 1657 SALT LAKE CITY UT 84210 CONTACT PHONE: 801-363-1933 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/19/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: ED DEPUTY INSPECTOR - DSHW 05/19/2010 INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/19/2010 NAME: UTAH BARREL INC. GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 12/03/1984 NAME: UTAH BARREL INC. GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 06/14/2010 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/19/2010 CAV COMPLIANCE ASSISTANCE VISIT 05/01/2008 CAV COMPLIANCE ASSISTANCE VISIT 03/12/1986 FCI FOCUSED COMPLIANCE INSPECTION 66 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) VIOLATIONS 03/12/1986 262.A GENERATORS - GENERAL ENFORCEMENTS 03/17/1986 120 WRITTEN INFORMAL HAZARDOUS WASTE D000 D001 IGNITABLE WASTE D002 CORROSIVE WASTE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F002 THE FOLLOWING SPENT HALOGENATED SOLVENTS: TETRACHLOROETHYLENE, METHYLENE CHLORIDE,TRICHLOROETHYLENE, 1,1,1-TRICHLOROETHANE,CHLOROBENZENE, 1,1,2-TRICHLORO-1,2,2- TRIFLUOROETHANE, ORTHO-DICHLOROBENZENE, TRICHLOROFLUOROMETHANE, AND 1,1,2, TRICHLOROETHANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F003 THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE, ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS; AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F005 THE FOLLOWING SPENT NONHALOGENATED SOLVENTS: TOLUENE, METHYL ETHYL KETONE,CARBON DISULFIDE, ISOBUTANOL, PYRIDINE,BENZENE, 2-ETHOXYETHANOL, AND 2-NITROPROPANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F002, OR F004; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES YES NOT REPORTED IMPLEMENTER LAMPS YES NOT REPORTED IMPLEMENTER PESTICIDES YES NOT REPORTED IMPLEMENTER MERCURY CONTAINING EQUIPMENT YES NOT REPORTED IMPLEMENTER CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 67 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) MAP ID# 4 Distance from Property: 0.02 mi. (106 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD035387737 OWNER TYPE: NOT REPORTED NAME: UTAH BARREL INC.OWNER NAME: NOT REPORTED ADDRESS: 370 WEST 900 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84110 OPERATOR NAME: NOT REPORTED CONTACT NAME: SANFORD PEPPER CONTACT ADDRESS: P O BOX 1657 SALT LAKE CITY UT 84210 CONTACT PHONE: 8013631933 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/19/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: ED DEPUTY INSPECTOR - DSHW 05/19/2010 INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/19/2010 NAME: UTAH BARREL INC. GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 12/03/1984 NAME: UTAH BARREL INC. GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 06/14/2010 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/19/2010 CAV COMPLIANCE ASSISTANCE VISIT 05/01/2008 CAV COMPLIANCE ASSISTANCE VISIT 03/12/1986 FCI FOCUSED COMPLIANCE INSPECTION 68 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) VIOLATIONS 03/12/1986 262.A GENERATORS - GENERAL ENFORCEMENTS 03/17/1986 120 WRITTEN INFORMAL HAZARDOUS WASTE D000 D001 IGNITABLE WASTE D002 CORROSIVE WASTE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F002 THE FOLLOWING SPENT HALOGENATED SOLVENTS: TETRACHLOROETHYLENE, METHYLENE CHLORIDE,TRICHLOROETHYLENE, 1,1,1-TRICHLOROETHANE,CHLOROBENZENE, 1,1,2-TRICHLORO-1,2,2- TRIFLUOROETHANE, ORTHO-DICHLOROBENZENE, TRICHLOROFLUOROMETHANE, AND 1,1,2, TRICHLOROETHANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F003 THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE, ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS; AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F005 THE FOLLOWING SPENT NONHALOGENATED SOLVENTS: TOLUENE, METHYL ETHYL KETONE,CARBON DISULFIDE, ISOBUTANOL, PYRIDINE,BENZENE, 2-ETHOXYETHANOL, AND 2-NITROPROPANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F002, OR F004; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES YES NOT REPORTED IMPLEMENTER LAMPS YES NOT REPORTED IMPLEMENTER PESTICIDES YES NOT REPORTED IMPLEMENTER MERCURY CONTAINING EQUIPMENT YES NOT REPORTED IMPLEMENTER CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 69 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 4 Distance from Property: 0.02 mi. (106 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110005196803 NAME: UTAH BARREL INC. LOCATION ADDRESS: 370 WEST 900 SOUTH SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE EPA REGION: 08 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: UTAH BARREL INC. PROGRAM/S LISTED FOR THIS FACILITY RCRAINFO - RESOURCE CONSERVATION AND RECOVERY ACT INFORMATION SYSTEM STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) NO SIC DATA REPORTED NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 70 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT) MAP ID# 5 Distance from Property: 0.03 mi. (158 ft.) SE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001923 FACILITY ID: 4647 FACILITY NAME: OLD GAS STATION - PROJECT SITE #EA-028-92 ADDRESS: 879 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: FIRST INTERSTATE BANK OF UTAH NA ADDRESS: 3815 S WEST TEMPLE SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 350-7128 TOTAL TANK: 5 CLOSED TANK: 5 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 4000 LAST USE: 6/21/1983 DATE CLOSED: 6/21/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 4000 LAST USE: 6/21/1983 DATE CLOSED: 6/21/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 71 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 4000 LAST USE: 6/21/1983 DATE CLOSED: 6/21/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 4 ALTERNATIVE TANK ID: 4 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: UNKNOWN TANK CAPACITY: 1000 LAST USE: 6/21/1983 DATE CLOSED: 6/21/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE 72 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST) TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 5 ALTERNATIVE TANK ID: 5 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 500 LAST USE: 6/21/1983 DATE CLOSED: 6/21/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 73 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST) MAP ID# 5 Distance from Property: 0.03 mi. (158 ft.) SE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001923LUST FACILITY ID: 4001923 FACILITY NAME: OLD GAS STATION - PROJECT SITE #EA-028-92 ADDRESS: 879 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: FIRST INTERSTATE BANK OF UTAH NA ADDRESS: 3815 S WEST TEMPLE SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [DALE URBAN] NOTIFICATION DATE: 3/26/1993 CLOSED DATE: 6/5/1996 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL OF TANKS Back to Report Summary 74 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 6 Distance from Property: 0.07 mi. (370 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002432LUST FACILITY ID: 4002432 FACILITY NAME: DEVROOM'S GARAGE ADDRESS: 777 S 300 W SALT LAKE CITY, UT 84106 COUNTY: SALT LAKE OWNER NAME: J.P. DEVROOM LLC ADDRESS: 777 S 300 W SALT LAKE CITY, UT 84106 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 6/4/2009 CLOSED DATE: NOT REPORTED CAUSE AND RELEASE CAUSE OF RELEASE: CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE SAMPLES Back to Report Summary 75 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 6 Distance from Property: 0.05 mi. (264 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000323 FACILITY ID: 3178 FACILITY NAME: GENE PENMAN 66 ADDRESS: 775 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: GENE PENMAN 66 ADDRESS: 775 S 300 W SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 532-9041 TOTAL TANK: 3 CLOSED TANK: 3 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 7000 LAST USE: 7/15/1996 DATE CLOSED: 4/8/1997 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 6/1/1956 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 7000 LAST USE: 7/15/1996 DATE CLOSED: 4/8/1997 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 4/1/1956 76 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: NO ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 300 LAST USE: 7/15/1996 DATE CLOSED: 4/8/1997 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 4/1/1956 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 77 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 6 Distance from Property: 0.07 mi. (370 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002432 FACILITY ID: 7497 FACILITY NAME: DEVROOM'S GARAGE ADDRESS: 777 S 300 W SALT LAKE CITY, UT 84106 COUNTY: SALT LAKE OWNER NAME: J.P. DEVROOM LLC ADDRESS: 777 S 300 W SALT LAKE CITY, UT 84106 OWNER PHONE: (801) 910-4539 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 500 LAST USE: NOT REPORTED DATE CLOSED: 6/4/2009 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1971 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 78 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) MAP ID# 6 Distance from Property: 0.05 mi. (264 ft.) E Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000323LUST FACILITY ID: 4000323 FACILITY NAME: GENE PENMAN 66 ADDRESS: 775 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: GENE PENMAN 66 ADDRESS: 775 S 300 W SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: HONG LEI TAO NOTIFICATION DATE: 4/9/1997 CLOSED DATE: 4/23/2015 CAUSE AND RELEASE CAUSE OF RELEASE: DISPENSER FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT Back to Report Summary 79 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 7 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTP000000034 OWNER TYPE: PRIVATE NAME: ARO PICKLE FACTORY OWNER NAME: EDWARD EISEN ADDRESS: 741 SOUTH 400 WEST OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84111 OPERATOR NAME: NOT REPORTED CONTACT NAME: MARK LOB CONTACT ADDRESS: 741 SOUTH 400 WEST SALT LAKE CITY UT 84111 CONTACT PHONE: 8012255659 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 02/22/2007 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 02/22/2007 NAME: ARO PICKLE FACTORY GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 03/09/1993 NAME: ARO PICKLE FACTORY GENERATOR CLASSIFICATION: NOT A GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 02/27/2007 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS - NO EVALUATIONS REPORTED - VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D001 IGNITABLE WASTE 80 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 81 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 8 Distance from Property: 0.06 mi. (317 ft.) SW Elevation: 4,229 ft. (Lower than TP) SITE INFORMATION ID#: 166302 NAME: UTAH BARREL AND SCRAP ADDRESS: 850 SOUTH 400 WEST SALT LAKE CITY, UT 84111 TYPE FUNDING: H PREDOMINANT PAST USE (ACREAGE): GREENSPACE: NOT REPORTED RESIDENTIAL: NOT REPORTED COMMERCIAL: NOT REPORTED INDUSTRIAL: 3.67 FUTURE USE (ACREAGE): GREENSPACE: NOT REPORTED RESIDENTIAL: NOT REPORTED COMMERCIAL: NOT REPORTED INDUSTRIAL: 3.67 PROPERTY HIGHLIGHT: NOT REPORTED PROPERTY SIZE (Acres): 3.67 CURRENT OWNER: ARTSPACE LLC PROPERTY DESCRIPTION/ FORMER USE: HISTORIC INDUSTRIAL OPERATIONS AT THIS SITE IN DOWNTOWN SLC INCLUDED OVER 75 YEARS OF ACTIVITY, INCLUDING 45 YEARS AS A FORMER SCRAP AND SALVAGE YARD. TWO PETROLEUM ASTS WERE ONCE LOCATED ON THE SITE AND REMOVED. CONTAMINATE(S): PETROLEUM, PCBS, OTHER METALS CONTAMINATE(S) CLEANED UP: PETROLEUM, PCBS, OTHER METALS MEDIA(S) AFFECTED: SOIL, GROUND WATER MEDIA(S) CLEANED UP: SOIL, GROUND WATER TYPE OF BROWNFIELD GRANT: SECTION 128(A) STATE/TRIBAL ENVIRONMENTAL ASSESSMENT ACTIVITY: PHASE II ENVIRONMENTAL ASSESSMENT ASSESSMENT START DATE: 3/19/1997 0:00 ASSESSMENT COMPLETION DATE: 6/7/1999 0:00 CLEANUP REQUIRED: YES STATE & TRIBAL ENROLLMENT ID: VCP C061 STATE & TRIBAL ENROLLMENT DATE: NOT REPORTED PROPERTY ENROLLED IN A STATE & TRIBAL PROGRAM?: 11/24/2007 0:00 ARE INSTITUTIONAL CONTROLS REQUIRED?: YES Back to Report Summary 82 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF) MAP ID# 9 Distance from Property: 0.07 mi. (370 ft.) SE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: UTD988070934 OWNER TYPE: PRIVATE NAME: CITY WELDING & RADIATOR WORKS OWNER NAME: INTERMOUNTAIN RADIATOR ADDRESS: 259 WEST 900 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: DON HUNTER CONTACT ADDRESS: 259 WEST 900 SOUTH SALT LAKE CITY UT 84101 CONTACT PHONE: 8013551112 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 11/15/2011 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 11/15/2011 NAME: CITY WELDING & RADIATOR WORKS GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 04/22/1991 NAME: CITY WELDING & RADIATOR WORKS GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 05/29/2013 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 10/21/2011 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE 83 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) D000 D008 LEAD UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 84 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) MAP ID# 9 Distance from Property: 0.07 mi. (370 ft.) SE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: UTD988070934 OWNER TYPE: PRIVATE NAME: CITY WELDING & RADIATOR WORKS OWNER NAME: INTERMOUNTAIN RADIATOR ADDRESS: 259 WEST 9TH SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: DON HUNTER CONTACT ADDRESS: 259 WEST 9TH SOUTH SALT LAKE CITY UT 84101 CONTACT PHONE: 801-355-1112 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 11/15/2011 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 11/15/2011 NAME: CITY WELDING & RADIATOR WORKS GENERATOR CLASSIFICATION: NOT A GENERATOR DATE RECEIVED BY AGENCY: 04/22/1991 NAME: CITY WELDING & RADIATOR WORKS GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: NOT A GENERATOR LAST UPDATED DATE: 05/29/2013 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 10/21/2011 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE 85 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) D000 D008 LEAD UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 86 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG) MAP ID# 10 Distance from Property: 0.08 mi. (422 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: UTD035347319 OWNER TYPE: PRIVATE NAME: A&E ALTERNATOR AND STARTERS OWNER NAME: WOOLF, MILTON ADDRESS: 264 WEST 800 SOUTH OPERATOR TYPE: PRIVATE SALT LAKE CITY, UT 84101 OPERATOR NAME: A & E ALTERNATOR AND STARTERS CONTACT NAME: PETE KEEN CONTACT ADDRESS: 264 WEST 800 SOUTH SALT LAKE CITY UT 84101 CONTACT PHONE: 8013288689 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 04/08/2009 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: PETE KEEN VICE PRESIDENT 04/01/2009 INDUSTRY CLASSIFICATION (NAICS) 81111 - AUTOMOTIVE MECHANICAL AND ELECTRICAL REPAIR AND MAINTENANCE SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 04/08/2009 NAME: A&E ALTERNATOR AND STARTERS GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 10/23/1986 NAME: A&E GENERATOR INC. GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR LAST UPDATED DATE: 09/16/2014 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 04/01/2009 CAV COMPLIANCE ASSISTANCE VISIT 87 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) 07/03/1996 FCI FOCUSED COMPLIANCE INSPECTION VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D001 IGNITABLE WASTE F003 THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE, ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS; AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F005 THE FOLLOWING SPENT NONHALOGENATED SOLVENTS: TOLUENE, METHYL ETHYL KETONE,CARBON DISULFIDE, ISOBUTANOL, PYRIDINE,BENZENE, 2-ETHOXYETHANOL, AND 2-NITROPROPANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F002, OR F004; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES NO NOT REPORTED NOTIFICATION LAMPS NO NOT REPORTED NOTIFICATION PESTICIDES NO NOT REPORTED NOTIFICATION MERCURY CONTAINING EQUIPMENT NO NOT REPORTED NOTIFICATION CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 88 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) MAP ID# 11 Distance from Property: 0.09 mi. (475 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000536 FACILITY ID: 3380 FACILITY NAME: C/O METRO STEEL ADDRESS: 401 W 900 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: WILLIS L BOND ADDRESS: 401 W 900 S SALT LAKE CITY, UT 84101 OWNER PHONE: NOT REPORTED TOTAL TANK: 2 CLOSED TANK: 2 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 1000 LAST USE: 6/22/1988 DATE CLOSED: 6/22/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 5/5/1976 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 500 LAST USE: 6/22/1988 DATE CLOSED: 6/22/1988 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 5/5/1976 89 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 90 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST) MAP ID# 12 Distance from Property: 0.09 mi. (475 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001610 FACILITY ID: 4347 FACILITY NAME: WAREHOUSE ADDRESS: 453 W 800 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: BUSH SALES & MFG ADDRESS: 344 W 800 S SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 322-1058 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 1800 LAST USE: 1/1/1975 DATE CLOSED: 5/14/1990 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1965 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: SAFE SUCTION PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 91 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) MAP ID# 13 Distance from Property: 0.09 mi. (475 ft.) SW Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: VCP-C061 FACILITY ID: C061 FACILITY NAME: UTAH BARREL AND SCRAP - ARTSPACE ADDRESS: 850 SOUTH 400 WEST AND 856 SOUTH 400 WEST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE STATUS: NOT REPORTED ACRES: NOT REPORTED AMENDED AGREEMENT DATE: 1/27/2009 ORIGINAL CERTIFICATE OF COMPLETION DATE: 5/6/2009 AMENDED CERTIFICATE OF COMPLETION DATE: 12/16/2009 EPA CERCLIS ARCHIVE DATE: NOT REPORTED TERMINATION DATE: NOT REPORTED PROJECT MANAGER: ELIZABETH PALMER NOTES: NOT REPORTED CERCLA BRANCH MAJOR ACTIVITIES MAJOR ACTIVITY STATE DESCRIPTION: COC AMENDMENT ISSUED START DATE: 12/16/2009 COMPLETION DATE: 12/16/2009 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: SITE MANAGEMENT CLOSED-OUT, ALL COC CONDITIONS MET START DATE: 12/16/2009 COMPLETION DATE: 12/16/2009 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: COC ISSUED START DATE: 5/6/2009 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: ENVIRONMENTAL COVENANT EXECUTED/ACCEPTED START DATE: 4/29/2009 COMPLETION DATE: 4/29/2009 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT AMENDED START DATE: 1/27/2009 COMPLETION DATE: 1/27/2009 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: SITE MANAGEMENT PLAN ACCEPTED START DATE: 12/16/2008 COMPLETION DATE: 12/16/2008 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT EXECUTED 92 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP) START DATE: 12/11/2007 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VOLUNTARY CLEANUP SITE APPLICATION RECEIVED START DATE: 10/24/2007 COMPLETION DATE: NOT REPORTED Back to Report Summary 93 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP) MAP ID# 14 Distance from Property: 0.09 mi. (475 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD982590994 OWNER TYPE: PRIVATE NAME: VENTURA'S CUSTOM AUTO PAINTING OWNER NAME: BILL VENTURA ADDRESS: 372 WEST AMERICAN AVE.OPERATOR TYPE: PRIVATE SALT LAKE CITY, UT 84101 OPERATOR NAME: VENTURA'S CUSTOM AUTO PAINTING CONTACT NAME: BILL VENTURA CONTACT ADDRESS: 372 WEST AMERICAN AVE. SALT LAKE CITY UT 84101 CONTACT PHONE: 8013289135 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 04/07/2010 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: BILL VENTURA MANAGER 04/07/2010 INDUSTRY CLASSIFICATION (NAICS) 811121 - AUTOMOTIVE BODY, PAINT, AND INTERIOR REPAIR AND MAINTENANCE SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 04/07/2010 NAME: VENTURA'S CUSTOM AUTO PAINTING GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 04/03/1989 NAME: VENTURA'S CUSTOM AUTO PAINTING GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR LAST UPDATED DATE: 06/18/2013 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 04/07/2010 CAV COMPLIANCE ASSISTANCE VISIT 94 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D001 IGNITABLE WASTE D018 BENZENE D035 METHYL ETHYL KETONE F003 THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE, ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS; AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F005 THE FOLLOWING SPENT NONHALOGENATED SOLVENTS: TOLUENE, METHYL ETHYL KETONE,CARBON DISULFIDE, ISOBUTANOL, PYRIDINE,BENZENE, 2-ETHOXYETHANOL, AND 2-NITROPROPANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F002, OR F004; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE WASTE TYPE:ACCUMULATED WASTE ON-SITE: GENERATED WASTE ON-SITE: SOURCE TYPE: BATTERIES NO NOT REPORTED NOTIFICATION LAMPS NO NOT REPORTED NOTIFICATION PESTICIDES NO NOT REPORTED NOTIFICATION MERCURY CONTAINING EQUIPMENT NO NOT REPORTED NOTIFICATION CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 95 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) MAP ID# 15 Distance from Property: 0.11 mi. (581 ft.) SE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000927 FACILITY ID: 3733 FACILITY NAME: SERVCO HEATING & AIR COND., INC. ADDRESS: 945 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SERVCO HEATING & AIR COND INC ADDRESS: 945 S 300 W SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 328-8734 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 1000 LAST USE: 7/10/1987 DATE CLOSED: 7/10/1987 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 5/1/1964 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 96 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST) MAP ID# 16 Distance from Property: 0.12 mi. (634 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD056090277 SITE ID#: 0800628 NAME: GALIGHER ASH CO. ADDRESS: 800 S 440 WEST SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE FEDERAL FACILITY: NOT A FEDERAL FACILITY NPL: NOT ON THE NPL NON NPL STATUS: NFRAP-SITE DOES NOT QUALIFY FOR THE NPL BASED ON EXISTING INFORMATION Below information was gathered from the prior NFRAP update completed in 10/2013 update: ACTION START DATE COMPLETION DATE RESPONSIBILITY DS - DISCOVERY NOT REPORTED 4/1/1981 EPA FUND PA - PRELIMINARY ASSESSMENT NOT REPORTED 12/1/1984 STATE (FUND) VS - ARCHIVE SITE NOT REPORTED 12/1/1984 EPA IN-HOUSE ACTION DESCRIPTIONS DS - (DISCOVERY) - THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. PA - (PRELIMINARY ASSESSMENT) - COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. VS - (ARCHIVE SITE) - THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE. Back to Report Summary 97 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH) MAP ID# 16 Distance from Property: 0.12 mi. (634 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001458 FACILITY ID: 4203 FACILITY NAME: BGA INTERNATIONAL ADDRESS: 440 W 800 S SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE OWNER NAME: BGA INTERNATIONAL ADDRESS: 440 W 800 S SALT LAKE CITY, UT 84110 OWNER PHONE: (801) 359-8731 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 1000 LAST USE: 11/20/1990 DATE CLOSED: 11/20/1990 CLOSURE STATUS: TANK CLOSED IN PLACE DATE INSTALLED: 12/14/1982 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: CONCRETE TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 98 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST) MAP ID# 16 Distance from Property: 0.12 mi. (634 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD056090277 OWNER TYPE: PRIVATE NAME: WEIR SPECIALTY PUMPS OWNER NAME: WEIR GROUP PCL ADDRESS: 440 WEST 800 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84110 OPERATOR NAME: NOT REPORTED CONTACT NAME: THOMAS DAWSON CONTACT ADDRESS: P.O. BOX 209 SALT LAKE CITY UT 84110 CONTACT PHONE: 8015307869 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 06/07/2001 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: LYNN R MARLOR DIR. HUMAN RES.02/09/1990 INDUSTRY CLASSIFICATION (NAICS) 333911 - PUMP AND PUMPING EQUIPMENT MANUFACTURING SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 06/07/2001 NAME: WEIR SPECIALTY PUMPS GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 12/21/1994 NAME: WEIR SPECIALTY PUMPS GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 02/09/1990 NAME: BGA INTERNATIONAL GENERATOR CLASSIFICATION: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: SMALL QUANTITY GENERATOR LAST UPDATED DATE: 09/16/2014 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION 99 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) EVALUATIONS 08/27/2014 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 01/16/2008 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE 12/15/1988 CEI COMPLIANCE EVALUATION INSPECTION ON-SITE VIOLATIONS 12/15/1988 262.A GENERATORS - GENERAL ENFORCEMENTS 02/22/1989 120 WRITTEN INFORMAL HAZARDOUS WASTE D000 D001 IGNITABLE WASTE D002 CORROSIVE WASTE D003 REACTIVE WASTE D006 CADMIUM D007 CHROMIUM D008 LEAD D018 BENZENE D035 METHYL ETHYL KETONE D039 TETRACHLOROETHYLENE D040 TRICHLORETHYLENE F001 THE FOLLOWING SPENT HALOGENATED SOLVENTS USED IN DEGREASING: TETRACHLOROETHYLENE,TRICHLORETHYLENE, METHYLENE CHLORIDE, 1,1,1-TRICHLOROETHANE, CARBON TETRACHLORIDE ANDCHLORINATED FLUOROCARBONS; ALL SPENT SOLVENT MIXTURES/BLENDS USED IN DEGREASING CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE HALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F003 THE FOLLOWING SPENT NON-HALOGENATED SOLVENTS: XYLENE, ACETONE, ETHYL ACETATE, ETHYL BENZENE, ETHYL ETHER, METHYL ISOBUTYL KETONE, N-BUTYL ALCOHOL, CYCLOHEXANONE, AND METHANOL; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONLY THE ABOVE SPENT NONHALOGENATED SOLVENTS; AND ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS, AND A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THOSE SOLVENTS LISTED IN F001, F002, F004, AND F005; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. F005 THE FOLLOWING SPENT NONHALOGENATED SOLVENTS: TOLUENE, METHYL ETHYL KETONE,CARBON DISULFIDE, ISOBUTANOL, PYRIDINE,BENZENE, 2-ETHOXYETHANOL, AND 2-NITROPROPANE; ALL SPENT SOLVENT MIXTURES/BLENDS CONTAINING, BEFORE USE, A TOTAL OF TEN PERCENT OR MORE (BY VOLUME) OF ONE OR MORE OF THE ABOVE NONHALOGENATED SOLVENTS OR THOSE SOLVENTS LISTED IN F001,F002, OR F004; AND STILL BOTTOMS FROM THE RECOVERY OF THESE SPENT SOLVENTS AND SPENT SOLVENT MIXTURES. UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 100 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) MAP ID# 17 Distance from Property: 0.12 mi. (634 ft.) S Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001651 FACILITY ID: 4387 FACILITY NAME: DAVID ORR/JEFF LYONS ADDRESS: 929 S RIO GRANDE ST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: DAVID ORR/JEFF LYONS ADDRESS: 929 S RIO GRANDE ST SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 359-0244 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 500 LAST USE: 6/15/1990 DATE CLOSED: 6/15/1990 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 101 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST) MAP ID# 17 Distance from Property: 0.12 mi. (634 ft.) S Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001651LUST FACILITY ID: 4001651 FACILITY NAME: DAVID ORR/JEFF LYONS ADDRESS: 929 S RIO GRANDE ST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: DAVID ORR/JEFF LYONS ADDRESS: 929 S RIO GRANDE ST SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [ROBIN JENKINS] NOTIFICATION DATE: 8/3/1990 CLOSED DATE: 4/20/1993 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: 413.1 Back to Report Summary 102 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 18 Distance from Property: 0.13 mi. (686 ft.) NE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTR000005249 OWNER TYPE: PRIVATE NAME: BESTWAY PRODUCTS CO.OWNER NAME: MARTY BECKSTEAD ADDRESS: 333 WEST 700 SOUTH OPERATOR TYPE: NOT REPORTED SALT LAKE CITY, UT 84101 OPERATOR NAME: NOT REPORTED CONTACT NAME: MARTY BECKSTEAD CONTACT ADDRESS: 333 WEST 700 SOUTH SALT LAKE CITY UT 84101 CONTACT PHONE: 8013284818 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 09/27/1999 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 09/27/1999 NAME: BESTWAY PRODUCTS CO. GENERATOR CLASSIFICATION: LARGE QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: CONDITIONALLY EXEMPT SMALL QUANTITY GENERATOR LAST UPDATED DATE: 09/16/2014 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS 05/14/2008 CAV COMPLIANCE ASSISTANCE VISIT VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D001 IGNITABLE WASTE D002 CORROSIVE WASTE UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - 103 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 104 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) MAP ID# 19 Distance from Property: 0.14 mi. (739 ft.) SE Elevation: 4,231 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000547 FACILITY ID: 3390 FACILITY NAME: RICCI INVESTMENT CO #5 ADDRESS: 208 W 900 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: RICCI INVESTMENT CO ADDRESS: 8 E BROADWAY STE 500 SALT LAKE CITY, UT 84111 OWNER PHONE: (801) 266-6383 TOTAL TANK: 3 CLOSED TANK: 3 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 12000 LAST USE: 9/1/1994 DATE CLOSED: 10/5/1995 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1969 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: GALVANIC CATHODIC PROTECTION (STIP3) TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 7500 LAST USE: 9/1/1994 DATE CLOSED: 10/5/1995 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1964 105 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: NO ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 7500 LAST USE: 9/1/1994 DATE CLOSED: 10/5/1995 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1964 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 106 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST) MAP ID# 19 Distance from Property: 0.14 mi. (739 ft.) SE Elevation: 4,231 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002054 FACILITY ID: 4770 FACILITY NAME: ALLEY RIGHT-OF-WAY BY METRO OIL ADDRESS: 208 W 900 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SALT LAKE CITY FLEET MANAGEMENT ADDRESS: 1990 W 500 S SALT LAKE CITY, UT 84104 OWNER PHONE: (801) 535-6904 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 4 ALTERNATIVE TANK ID: 4 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 250 LAST USE: 1/1/1985 DATE CLOSED: 10/5/1995 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1964 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 107 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) MAP ID# 19 Distance from Property: 0.14 mi. (739 ft.) SE Elevation: 4,231 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000547LUST FACILITY ID: 4000547 FACILITY NAME: RICCI INVESTMENT CO #5 ADDRESS: 208 W 900 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: RICCI INVESTMENT CO ADDRESS: 8 E BROADWAY STE 500 SALT LAKE CITY, UT 84111 FACILITY DETAILS PROJECT MANAGER: KEVIN BEERY NOTIFICATION DATE: 12/8/2015 CLOSED DATE: NOT REPORTED ----------------------- PROJECT MANAGER: [ROCKY STONESTREET] NOTIFICATION DATE: 6/4/1991 CLOSED DATE: 12/23/1994 CAUSE AND RELEASE CAUSE OF RELEASE: OVERFILL, 12K TANK HAD PRODUCT IN IT, ALSO HAD NUM SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE SAMPLES CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: INSPECTION, REMOVAL Back to Report Summary 108 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 20 Distance from Property: 0.15 mi. (792 ft.) NE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: UTD988066155 DERR ID: UTD988066155 FACILITY NAME: OLD SALT LAKE CITY FIRE STATION ADDRESS: 2ND WEST 7TH SOUTH SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE PROJECT MANAGER: NOT REPORTED CONTACT PHONE: NOT REPORTED PROJECT DESCRIPTION: THIS SITE IS LOCATED AT 2ND WEST 7TH SOUTH N SALT LAKE CITY, UTAH. SOLVENTS, DETERGENTS, GREASES, ETC. WERE DUMPED INTO FLOOR DRAIN SUMPS. CHLOROBENZENE, O-DICHLOROBENZENE, TOLUENE, XYLENE, ACETONE, AND ETHYLBENZENE HAVE BEEN DETECTED. MATERIALS IN SUMP FLOWED INTO SURROUNDING SOILS. SOIL CONTAMINATION AND SLUDGES ARE PRESENT BELOW THE WATER TABLE. CONTAMINATED AREAS HAVE SINCE BEEN ADEQUATELY COVERED. THE SITE BEGAN OPERATION IN 1964. IT ENDED OPERATION IN 1984 OR 1985. EMERGENCY RESPONSE BRANCH: NO NATIONAL PRIORITY LIST: NO PROPOSED FOR NPL: NO ARCHIVED FOR CERCLIS: YES Back to Report Summary 109 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS) MAP ID# 20 Distance from Property: 0.15 mi. (792 ft.) NE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD988066155 SITE ID#: 0800272 NAME: OLD SALT LAKE CITY FIRE STATION ADDRESS: 2ND WEST 7TH SOUTH SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE FEDERAL FACILITY: NOT A FEDERAL FACILITY NPL: NOT ON THE NPL NON NPL STATUS: NFRAP-SITE DOES NOT QUALIFY FOR THE NPL BASED ON EXISTING INFORMATION Below information was gathered from the prior NFRAP update completed in 10/2013 update: ACTION START DATE COMPLETION DATE RESPONSIBILITY DS - DISCOVERY NOT REPORTED 2/25/1989 EPA FUND PA - PRELIMINARY ASSESSMENT NOT REPORTED 12/19/1989 STATE (FUND) VS - ARCHIVE SITE NOT REPORTED 12/19/1989 EPA IN-HOUSE ACTION DESCRIPTIONS DS - (DISCOVERY) - THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. PA - (PRELIMINARY ASSESSMENT) - COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. VS - (ARCHIVE SITE) - THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE. Back to Report Summary 110 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH) MAP ID# 21 Distance from Property: 0.15 mi. (792 ft.) SE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001222 FACILITY ID: 4004 FACILITY NAME: VOGUE CLEANING ADDRESS: 906 S 200 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: VOGUE CLEANING ADDRESS: 906 S 200 W SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 363-2627 TOTAL TANK: 2 CLOSED TANK: 2 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: HAZARDOUS SUBSTANCE TANK CAPACITY: 500 LAST USE: 1/1/1988 DATE CLOSED: 12/11/1990 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 4/11/1971 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: LINED INTERIOR TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: HAZARDOUS SUBSTANCE TANK CAPACITY: 500 LAST USE: 1/1/1988 DATE CLOSED: 12/11/1990 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 4/11/1971 111 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: LINED INTERIOR TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 112 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST) MAP ID# 21 Distance from Property: 0.15 mi. (792 ft.) SE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001222LUST FACILITY ID: 4001222 FACILITY NAME: VOGUE CLEANING ADDRESS: 906 S 200 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: VOGUE CLEANING ADDRESS: 906 S 200 W SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [EVAN SULLIVAN] NOTIFICATION DATE: 12/14/1990 CLOSED DATE: 10/29/1996 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 113 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 22 Distance from Property: 0.18 mi. (950 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: UTD056090277 DERR ID: UTD056090277 FACILITY NAME: GALIGHER ASH CO. ADDRESS: 800 SOUTH 440 WEST SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE PROJECT MANAGER: NOT REPORTED CONTACT PHONE: NOT REPORTED PROJECT DESCRIPTION: MANUFACTURING PLANT. NO ON-SITE WASTE DISPOSAL. EMERGENCY RESPONSE BRANCH: NO NATIONAL PRIORITY LIST: NO PROPOSED FOR NPL: NO ARCHIVED FOR CERCLIS: YES Back to Report Summary 114 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS) MAP ID# 23 Distance from Property: 0.2 mi. (1,056 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001100 FACILITY ID: 3896 FACILITY NAME: SALT LAKE CITY-9TH SOUTH SEC. ADDRESS: 900 S 500 W SALT LAKE CITY, UT 84116 COUNTY: SALT LAKE OWNER NAME: UNION PACIFIC RAILROAD CO ADDRESS: 1416 DODGE ST ROOM 930 OMAHA, NE 68179 OWNER PHONE: (402) 271-3031 TOTAL TANK: 2 CLOSED TANK: 2 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 250 LAST USE: 4/1/1976 DATE CLOSED: 1/30/1990 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 4/30/1971 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: OTHER TANK CAPACITY: 10000 LAST USE: 4/1/1976 DATE CLOSED: 1/30/1990 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 115 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 116 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST) MAP ID# 23 Distance from Property: 0.2 mi. (1,056 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001100LUST FACILITY ID: 4001100 FACILITY NAME: SALT LAKE CITY-9TH SOUTH SEC. ADDRESS: 900 S 500 W SALT LAKE CITY, UT 84116 COUNTY: SALT LAKE OWNER NAME: UNION PACIFIC RAILROAD CO ADDRESS: 1416 DODGE ST ROOM 930 OMAHA, NE 68179 FACILITY DETAILS PROJECT MANAGER: [SHELLY QUICK] NOTIFICATION DATE: 3/28/1990 CLOSED DATE: 2/7/1996 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, SOIL SAMPLING Back to Report Summary 117 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 24 Distance from Property: 0.2 mi. (1,056 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000658 FACILITY ID: 3493 FACILITY NAME: NORM BULLOCK TOWING COMPANY ADDRESS: 435 W FAYETTE AVE ( 965 S ) SALT LAKE CITY, UT 84115 COUNTY: SALT LAKE OWNER NAME: FORD ENTERPRISES ADDRESS: 1904 E 5150 S SALT LAKE CITY, UT 84117 OWNER PHONE: (801) 278-8752 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: DIESEL TANK CAPACITY: 8000 LAST USE: 9/1/1989 DATE CLOSED: 9/1/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 4/12/1971 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 118 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 24 Distance from Property: 0.2 mi. (1,056 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000658LUST FACILITY ID: 4000658 FACILITY NAME: NORM BULLOCK TOWING COMPANY ADDRESS: 435 W FAYETTE AVE ( 965 S ) SALT LAKE CITY, UT 84115 COUNTY: SALT LAKE OWNER NAME: FORD ENTERPRISES ADDRESS: 1904 E 5150 S SALT LAKE CITY, UT 84117 FACILITY DETAILS PROJECT MANAGER: JOHN MENATTI NOTIFICATION DATE: 9/1/1989 CLOSED DATE: 6/21/1999 CAUSE AND RELEASE CAUSE OF RELEASE: PROBABLE SPILLAGE SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: NOT INDICATED/UNKNOWN CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, 8015 MOD Back to Report Summary 119 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 25 Distance from Property: 0.2 mi. (1,056 ft.) S Elevation: 4,231 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000203 FACILITY ID: 3068 FACILITY NAME: CUMMINS ROCKY MOUNTAIN LLC ADDRESS: 1030 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: CUMMINS ROCKY MOUNTAIN LLC ADDRESS: 2167 S 5370 W WEST VALLEY CITY, UT 84120 OWNER PHONE: (801) 355-6500 TOTAL TANK: 8 CLOSED TANK: 8 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 2 STATUS: TEMPORARILY OUT OF USE SUBSTANCE: NEW OIL TANK CAPACITY: 4000 LAST USE: 2/1/2010 DATE CLOSED: NOT REPORTED CLOSURE STATUS: NOT REPORTED DATE INSTALLED: 10/20/1989 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: U.S. SUCTION PIPE RELEASE DETECTION: LTT PST FUND: YES ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 3 STATUS: CURRENTLY IN USE SUBSTANCE: DIESEL TANK CAPACITY: 2000 LAST USE: NOT REPORTED DATE CLOSED: NOT REPORTED CLOSURE STATUS: NOT REPORTED DATE INSTALLED: 10/20/1989 120 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: PRESSURIZED PIPE RELEASE DETECTION: LTT PST FUND: YES ----------------------- TANK ID: 3 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 1000 LAST USE: NOT REPORTED DATE CLOSED: 6/20/2003 CLOSURE STATUS: TANK CLOSED IN PLACE DATE INSTALLED: 10/20/1989 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: FIBERGLASS REINFORCED PLASTIC TANK MODSDE: NONE TANK RELEASE DETECTION: AUTOMATIC TANK GAUGING PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: YES ----------------------- TANK ID: 4 ALTERNATIVE TANK ID: 4 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 2000 LAST USE: 10/9/1989 DATE CLOSED: 10/9/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 3/26/1973 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE 121 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 5 ALTERNATIVE TANK ID: 5 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: NEW OIL TANK CAPACITY: 5000 LAST USE: 10/9/1989 DATE CLOSED: 10/9/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 3/26/1968 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 6 ALTERNATIVE TANK ID: 6 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: NEW OIL TANK CAPACITY: 5000 LAST USE: 10/9/1989 DATE CLOSED: 10/9/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 3/26/1968 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER 122 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) PST FUND: NO ----------------------- TANK ID: 7 ALTERNATIVE TANK ID: 7 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: DIESEL TANK CAPACITY: 5000 LAST USE: 10/9/1989 DATE CLOSED: 10/9/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 3/26/1968 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 8 ALTERNATIVE TANK ID: 8 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 5000 LAST USE: 10/9/1989 DATE CLOSED: 10/9/1989 CLOSURE STATUS: TANK CLOSED IN PLACE DATE INSTALLED: 3/26/1968 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 123 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 25 Distance from Property: 0.2 mi. (1,056 ft.) S Elevation: 4,231 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: VCP-C039 FACILITY ID: C039 FACILITY NAME: CUMMINS INTERMOUNTAIN - SLC ADDRESS: 1030 SOUTH 300 WEST SALT LAKE CITY, UT 84125 COUNTY: SALT LAKE STATUS: NOT REPORTED ACRES: NOT REPORTED AMENDED AGREEMENT DATE: NOT REPORTED ORIGINAL CERTIFICATE OF COMPLETION DATE: 2/19/2008 AMENDED CERTIFICATE OF COMPLETION DATE: NOT REPORTED EPA CERCLIS ARCHIVE DATE: NOT REPORTED TERMINATION DATE: NOT REPORTED PROJECT MANAGER: DAVID BIRD NOTES: NOT REPORTED CERCLA BRANCH MAJOR ACTIVITIES MAJOR ACTIVITY STATE DESCRIPTION: COC ISSUED START DATE: 2/19/2008 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT EXECUTED START DATE: 5/24/2005 COMPLETION DATE: 5/24/2005 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VOLUNTARY CLEANUP SITE APPLICATION RECEIVED START DATE: 2/24/2005 COMPLETION DATE: 2/24/2005 Back to Report Summary 124 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP) MAP ID# 25 Distance from Property: 0.21 mi. (1,109 ft.) S Elevation: 4,231 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000203LUST FACILITY ID: 4000203 FACILITY NAME: CUMMINS ROCKY MOUNTAIN LLC ADDRESS: 1030 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: CUMMINS ROCKY MOUNTAIN LLC ADDRESS: 2167 S 5370 W WEST VALLEY CITY, UT 84120 FACILITY DETAILS PROJECT MANAGER: HONG LEI TAO NOTIFICATION DATE: 7/5/2012 CLOSED DATE: 9/7/2012 ----------------------- PROJECT MANAGER: [DEANN RASMUSSEN] NOTIFICATION DATE: 10/6/1989 CLOSED DATE: 12/20/1996 CAUSE RELEASE NO CAUSE AND RELEASE REPORTED Back to Report Summary 125 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST) MAP ID# 26 Distance from Property: 0.22 mi. (1,162 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000550LUST FACILITY ID: 4000550 FACILITY NAME: CRYSTAL TRUCKING COMPANY ADDRESS: 451 W FAYETTE AVE ( 965 S ) SALT LAKE CITY, UT 84115 COUNTY: SALT LAKE OWNER NAME: M & M DISTRIBUTING CORP ADDRESS: 1890 S 500 W SALT LAKE CITY, UT 84115 FACILITY DETAILS PROJECT MANAGER: JOHN MENATTI NOTIFICATION DATE: 2/23/1995 CLOSED DATE: 2/28/2001 CAUSE AND RELEASE CAUSE OF RELEASE: NOT STATED - TANKS REMOVED SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: ANLYT-SOIL: STAINING, ANLYT-H20: SHEEN Back to Report Summary 126 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 27 Distance from Property: 0.25 mi. (1,320 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001311 FACILITY ID: 4081 FACILITY NAME: C.W. SILVER CO., INC. ADDRESS: 535 W 700 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SILCO INC ADDRESS: P O BOX 17695 SALT LAKE CITY, UT 84117 OWNER PHONE: (801) 277-7327 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 500 LAST USE: 10/1/1989 DATE CLOSED: 10/1/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 9/30/1978 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: UNKNOWN PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 127 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 27 Distance from Property: 0.22 mi. (1,162 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001563 FACILITY ID: 4302 FACILITY NAME: SILCO LTD. ADDRESS: 501 W 700 S ;; SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: ESTATE OF CW SILVER ADDRESS: 550 W 700 S SALT LAKE CITY, UT 84101 OWNER PHONE: (801) 359-0832 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 1000 LAST USE: 1/1/1970 DATE CLOSED: 12/30/1989 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: SAFE SUCTION PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 128 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) MAP ID# 27 Distance from Property: 0.22 mi. (1,162 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001563LUST FACILITY ID: 4001563 FACILITY NAME: SILCO LTD. ADDRESS: 501 W 700 S ;; SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: ESTATE OF CW SILVER ADDRESS: 550 W 700 S SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [VICTOR SCHERER] NOTIFICATION DATE: 1/23/1990 CLOSED DATE: 5/16/1995 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: CLOSURE, OVA Back to Report Summary 129 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 28 Distance from Property: 0.22 mi. (1,162 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4002025 FACILITY ID: 4743 FACILITY NAME: JACKS PROPERTY ADDRESS: 156 W 900 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: JACK HILL ADDRESS: 1486 N MAIN LAYTON, UT 84041 OWNER PHONE: (801) 000-0000 TOTAL TANK: 2 CLOSED TANK: 2 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: NOT LISTED TANK CAPACITY: 8000 LAST USE: 5/5/1965 DATE CLOSED: 6/30/1997 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: NOT LISTED TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: NOT LISTED TANK CAPACITY: 8000 LAST USE: 5/5/1965 DATE CLOSED: 6/30/1997 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1910 130 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: NOT LISTED TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: NOT LISTED PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 131 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 28 Distance from Property: 0.22 mi. (1,162 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4002025LUST FACILITY ID: 4002025 FACILITY NAME: JACKS PROPERTY ADDRESS: 156 W 900 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: JACK HILL ADDRESS: 1486 N MAIN LAYTON, UT 84041 FACILITY DETAILS PROJECT MANAGER: [VICTOR SCHERER] NOTIFICATION DATE: 5/4/1995 CLOSED DATE: 1/4/1999 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: FIELD INSTRUMENTATION CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: ANALYT: SOIL, H2O Back to Report Summary 132 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 29 Distance from Property: 0.22 mi. (1,162 ft.) SW Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001172 FACILITY ID: 3959 FACILITY NAME: PIONEER WHOLESALE ADDRESS: 920 S 500 W SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE OWNER NAME: PIONEER WHOLESALE ADDRESS: 920 S 500 W SALT LAKE CITY, UT 84110 OWNER PHONE: (801) 355-5456 TOTAL TANK: 2 CLOSED TANK: 2 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: GASOLINE TANK CAPACITY: 1000 LAST USE: 6/1/1984 DATE CLOSED: 6/1/1984 CLOSURE STATUS: TANK CLOSED IN PLACE DATE INSTALLED: 5/20/1961 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO ----------------------- TANK ID: 2 ALTERNATIVE TANK ID: 2 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: DIESEL TANK CAPACITY: 2000 LAST USE: 6/30/1991 DATE CLOSED: 11/5/1991 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 5/21/1975 133 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: TTT/IC PIPE MATERIAL: GALVANIZED STEEL PIPE MODDES: NONE PIPE TYPE: U.S. SUCTION PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 134 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 29 Distance from Property: 0.22 mi. (1,162 ft.) SW Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001172LUST FACILITY ID: 4001172 FACILITY NAME: PIONEER WHOLESALE ADDRESS: 920 S 500 W SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE OWNER NAME: PIONEER WHOLESALE ADDRESS: 920 S 500 W SALT LAKE CITY, UT 84110 FACILITY DETAILS PROJECT MANAGER: [VICTOR SCHERER] NOTIFICATION DATE: 8/25/1993 CLOSED DATE: 5/9/1995 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL - PERMANENT - 2000 GAL. Back to Report Summary 135 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 30 Distance from Property: 0.23 mi. (1,214 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002053 FACILITY ID: 4769 FACILITY NAME: ROCKMONT INDUSTRIAL CORP. ADDRESS: 774 S 500 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: ROCKMONT INDUSTRIAL CORP ADDRESS: 774 S 500 W SALT LAKE CITY, UT 84101 OWNER PHONE: NOT REPORTED TOTAL TANK: NOT REPORTED CLOSED TANK: NOT REPORTED TANK INFORMATION NO TANK INFORMATION REPORTED COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 136 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 31 Distance from Property: 0.24 mi. (1,267 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002206 FACILITY ID: 6620 FACILITY NAME: NICHOLAS & COMPANY FOOD ADDRESS: 500 W FAYETTE AVENUE ( 965 S.) SALT LAKE CITY, UT 84115 COUNTY: SALT LAKE OWNER NAME: M & M DISTRIBUTING CORP ADDRESS: 1890 S 500 W SALT LAKE CITY, UT 84115 OWNER PHONE: (801) 972-4255 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 3 ALTERNATIVE TANK ID: 3 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: DIESEL TANK CAPACITY: 3000 LAST USE: 1/1/1977 DATE CLOSED: 2/24/1995 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/1/1972 IN COMPLIANCE: NO ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: ASPHALT COATED OR BARE STEEL TANK MODSDE: NONE TANK RELEASE DETECTION: OTHER PIPE MATERIAL: BARE STEEL PIPE MODDES: NONE PIPE TYPE: NOT LISTED PIPE RELEASE DETECTION: OTHER PST FUND: NO COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 137 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST) MAP ID# 31 Distance from Property: 0.24 mi. (1,267 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002206LUST FACILITY ID: 4002206 FACILITY NAME: NICHOLAS & COMPANY FOOD ADDRESS: 500 W FAYETTE AVENUE ( 965 S.) SALT LAKE CITY, UT 84115 COUNTY: SALT LAKE OWNER NAME: M & M DISTRIBUTING CORP ADDRESS: 1890 S 500 W SALT LAKE CITY, UT 84115 FACILITY DETAILS PROJECT MANAGER: JOHN MENATTI NOTIFICATION DATE: 4/7/1995 CLOSED DATE: 3/20/1998 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 138 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 32 Distance from Property: 0.26 mi. (1,373 ft.) E Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001733 FACILITY ID: 4466 FACILITY NAME: RICK WARNER FORD ADDRESS: 730 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: LARRY H MILLER CORP SOUTHTOWNE INC ADDRESS: 10986 S STATE SANDY, UT 84070 OWNER PHONE: (801) 563-4134 TOTAL TANK: 1 CLOSED TANK: 1 TANK INFORMATION TANK ID: 1 ALTERNATIVE TANK ID: 1 STATUS: PERMANENTLY OUT OF USE SUBSTANCE: USED OIL TANK CAPACITY: 4000 LAST USE: 12/17/2001 DATE CLOSED: 12/18/2001 CLOSURE STATUS: TANK REMOVED FROM GROUND DATE INSTALLED: 1/25/1990 IN COMPLIANCE: YES ABOVE TANK: NO TANK EMERGE: NO TANK MATERIAL: GALVANIC CATHODIC PROTECTION (STIP3) TANK MODSDE: DOUBLE-WALLED TANK RELEASE DETECTION: INTERSTITIAL DW PIPE MATERIAL: FIBERGLASS REINFORCED PLASTIC PIPE MODDES: NONE PIPE TYPE: GRAVITY FEED PIPE RELEASE DETECTION: OTHER PST FUND: YES COMPLIANCE UST NO COMPLIANCE UST REPORTED Back to Report Summary 139 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST) MAP ID# 32 Distance from Property: 0.26 mi. (1,373 ft.) E Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001733LUST FACILITY ID: 4001733 FACILITY NAME: RICK WARNER FORD ADDRESS: 730 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: LARRY H MILLER CORP SOUTHTOWNE INC ADDRESS: 10986 S STATE SANDY, UT 84070 FACILITY DETAILS PROJECT MANAGER: HONG LEI TAO NOTIFICATION DATE: 1/24/2002 CLOSED DATE: 4/25/2002 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: PERMANENT CLOSURE Back to Report Summary 140 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST) MAP ID# 33 Distance from Property: 0.27 mi. (1,426 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4002023LUST FACILITY ID: 4002023 FACILITY NAME: SATURN OF SALT LAKE ADDRESS: 770 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SATURN OF SALT LAKE ADDRESS: 770 S WEST TEMPLE SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: UST NOTIFICATION DATE: 11/14/2000 CLOSED DATE: 11/22/2000 CAUSE AND RELEASE CAUSE OF RELEASE: OVERFILL PROTECTION FAILURE SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: PERMANENT CLOSURE SAMPLES Back to Report Summary 141 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 34 Distance from Property: 0.29 mi. (1,531 ft.) E Elevation: 4,235 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000941LUST FACILITY ID: 4000941 FACILITY NAME: CNG AMERICA SLC ADDRESS: 110 W 900 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: UINTAH COMMERICAL INVESTMENT, LLC ADDRESS: 3199 ROCKPORT BLVD WANSHIP, UT 84017 FACILITY DETAILS PROJECT MANAGER: [DEANN RASMUSSEN] NOTIFICATION DATE: 12/15/1997 CLOSED DATE: 3/28/2005 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: OTHER: VAPORS IN RESTAURANT Back to Report Summary 142 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 35 Distance from Property: 0.29 mi. (1,531 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001045LUST FACILITY ID: 4001045 FACILITY NAME: 7-ELEVEN 1851-26282 ADDRESS: 111 W 800 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: 7-ELEVEN INC ADDRESS: PO BOX 711 DALLAS, TX 75221 FACILITY DETAILS PROJECT MANAGER: MIKE PECORELLI NOTIFICATION DATE: 10/12/2012 CLOSED DATE: 9/20/2013 CAUSE RELEASE NO CAUSE AND RELEASE REPORTED Back to Report Summary 143 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 36 Distance from Property: 0.29 mi. (1,531 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: VCP-C004 FACILITY ID: C004 FACILITY NAME: C. W. SILVER ADDRESS: 550 AND 552 WEST 700 SOUTH SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE STATUS: NOT REPORTED ACRES: NOT REPORTED AMENDED AGREEMENT DATE: NOT REPORTED ORIGINAL CERTIFICATE OF COMPLETION DATE: 1/11/1999 AMENDED CERTIFICATE OF COMPLETION DATE: NOT REPORTED EPA CERCLIS ARCHIVE DATE: NOT REPORTED TERMINATION DATE: NOT REPORTED PROJECT MANAGER: KRISTEN (LEIGH) ANDERSON NOTES: NOT REPORTED CERCLA BRANCH MAJOR ACTIVITIES MAJOR ACTIVITY STATE DESCRIPTION: COC ISSUED START DATE: 1/11/1999 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT EXECUTED START DATE: 9/18/1997 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VOLUNTARY CLEANUP SITE APPLICATION RECEIVED START DATE: 8/11/1997 COMPLETION DATE: NOT REPORTED Back to Report Summary 144 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP) MAP ID# 37 Distance from Property: 0.29 mi. (1,531 ft.) NE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: PRE8 DERR ID: PRE8 FACILITY NAME: SALT LAKE CITY GATEWAY PILOT PROJECT ADDRESS: NORTH TEMPLE ON NORTH, 300 WEST ON EAST, I15 ON WEST, 900 SOUTH STREET ON SOUTH SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE SITE TYPE: BROWNFIELDS PROJECT - PRE8 PROJECT MANAGER: [BRENT EVERETT] CONTACT PHONE: 8015364171 PROJECT DESCRIPTION: NOT REPORTED Back to Report Summary 145 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF) MAP ID# 38 Distance from Property: 0.31 mi. (1,637 ft.) N Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000641LUST FACILITY ID: 4000641 FACILITY NAME: N.P. METTOME CO. ADDRESS: 465 W 600 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: N P METTOME COMPANY ADDRESS: 471 W 600 S SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [ROCKY STONESTREET] NOTIFICATION DATE: 11/5/1990 CLOSED DATE: 1/4/1996 CAUSE AND RELEASE CAUSE OF RELEASE: OTHER: TANK FAILURE, PIPING, DISPENSER SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 146 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST) MAP ID# 39 Distance from Property: 0.32 mi. (1,690 ft.) NW Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4000270LUST FACILITY ID: 4000270 FACILITY NAME: 5TH & 6TH STREET BUSINESS CENTER ADDRESS: 537 W 600 S SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE OWNER NAME: BAKER HUGHES INC ADDRESS: P O BOX 4740 HOUSTON, TX 77210 FACILITY DETAILS PROJECT MANAGER: [KATE JOHNSON] NOTIFICATION DATE: 1/31/1992 CLOSED DATE: 6/29/1994 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: OTHER: PERMANENT CLOSURE-SOIL STAINING CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: OTHER: PERMANENT CLOSURE- SOIL STAINING CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: OTHER: PERMANENT CLOSURE-SOIL STAINING Back to Report Summary 147 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 40 Distance from Property: 0.33 mi. (1,742 ft.) W Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4000520LUST FACILITY ID: 4000520 FACILITY NAME: LONE STAR INDUSTRIES, INC. ADDRESS: 615 W 800 S SALT LAKE CITY, UT 84104 COUNTY: SALT LAKE OWNER NAME: LONE STAR INDUSTRIES INC ADDRESS: ONE GREENWICH PLAZA GREENWICH, CT 06836 FACILITY DETAILS PROJECT MANAGER: [SHELLY QUICK] NOTIFICATION DATE: 11/8/1989 CLOSED DATE: 1/5/1995 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 148 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 41 Distance from Property: 0.33 mi. (1,742 ft.) N Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4002065LUST FACILITY ID: 4002065 FACILITY NAME: THRILLER CAR COMPANY ADDRESS: 346 W 600 S SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE OWNER NAME: QUAIL RUN ENTERPRIZES ADDRESS: 9565 WASATCH BLVD SANDY, UT 84092 FACILITY DETAILS PROJECT MANAGER: [DEANN RASMUSSEN] NOTIFICATION DATE: 5/3/1996 CLOSED DATE: 8/6/1996 CAUSE AND RELEASE CAUSE OF RELEASE: PROBABLE SPILL/OVERFILL SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: PROBABLE SPILL/OVERFILL SUBSTANCE RELEASE: OTHER:NEW OIL/LUBE OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: CLOSURE INSPECTION Back to Report Summary 149 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 42 Distance from Property: 0.34 mi. (1,795 ft.) NE Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000974LUST FACILITY ID: 4000974 FACILITY NAME: SUPER SONIC CAR WASH ADDRESS: 672 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SUPER SONIC CAR WASH ADDRESS: 3851 RIVERDALE RD OGDEN, UT 84405 FACILITY DETAILS PROJECT MANAGER: [DALE URBAN] NOTIFICATION DATE: 10/10/1990 CLOSED DATE: 3/30/1995 CAUSE AND RELEASE CAUSE OF RELEASE: MINOR OVERFILL SPILLAGE SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: MINOR OVERFILL SPILLAGE SUBSTANCE RELEASE: OTHER:NEW OIL/LUBE OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, 413.1 Back to Report Summary 150 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 43 Distance from Property: 0.34 mi. (1,795 ft.) E Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4002278LUST FACILITY ID: 4002278 FACILITY NAME: FORMER COCA COLA BOTTLING ADDRESS: 875 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: WEST HOUSTON TECHNOLOGY VENTURES ADDRESS: 6100 HILLCROFT STE 600 HOUSTON, TX 77081 FACILITY DETAILS PROJECT MANAGER: JOHN MENATTI NOTIFICATION DATE: 12/1/2000 CLOSED DATE: 4/12/2001 CAUSE AND RELEASE CAUSE OF RELEASE: PIPING FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: OTHER: ANALYTICAL SOIL RESULTS CAUSE OF RELEASE: PIPING FAILURE SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: OTHER: ANALYTICAL SOIL RESULTS Back to Report Summary 151 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 44 Distance from Property: 0.34 mi. (1,795 ft.) NE Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000421LUST FACILITY ID: 4000421 FACILITY NAME: MAVERIK #331 ADDRESS: 615 S 200 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: MAVERIK COUNTRY STORES INC. ADDRESS: 880 W CENTER STREET NORTH SALT LAKE, UT 84054 FACILITY DETAILS PROJECT MANAGER: UST NOTIFICATION DATE: 9/30/2015 CLOSED DATE: 11/5/2015 ----------------------- PROJECT MANAGER: ROBIN DAVIS NOTIFICATION DATE: 10/12/2006 CLOSED DATE: 3/12/2013 CAUSE RELEASE NO CAUSE AND RELEASE REPORTED Back to Report Summary 152 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 45 Distance from Property: 0.38 mi. (2,006 ft.) E Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000047LUST FACILITY ID: 4000047 FACILITY NAME: RICK WARNER CHRYSLER PLYMOUTH ADDRESS: 777 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: RICK WARNER CHRYSLER PLYMOUTH ADDRESS: 777 S WEST TEMPLE SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 1/11/1999 CLOSED DATE: 3/5/1999 ----------------------- PROJECT MANAGER: [ROBERT GRANDY] NOTIFICATION DATE: 8/8/1994 CLOSED DATE: 5/9/1995 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: NOT REPORTED Back to Report Summary 153 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 46 Distance from Property: 0.4 mi. (2,112 ft.) E Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001879LUST FACILITY ID: 4001879 FACILITY NAME: VACANT PROPERTY ADDRESS: 50 W 900 S SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: JEWELL REICHERT MAXINE BLACK ADDRESS: 5250 S SPRING LEAF DR SALT LAKE CITY, UT 84117 FACILITY DETAILS PROJECT MANAGER: [DALE URBAN] NOTIFICATION DATE: 5/27/1992 CLOSED DATE: 7/1/1998 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT CAUSE OF RELEASE: PIPING FAILURE SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: 8015M/8020 Back to Report Summary 154 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 47 Distance from Property: 0.4 mi. (2,112 ft.) E Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001237LUST FACILITY ID: 4001237 FACILITY NAME: WAGSTAFF'S TOYOTA ADDRESS: 84 W 700 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: WAGSTAFFS TOYOTA ADDRESS: 84 W 700 S SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [EVAN SULLIVAN] NOTIFICATION DATE: 3/16/1990 CLOSED DATE: 2/10/1997 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: OTHER METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: SOIL BORINGS Back to Report Summary 155 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 48 Distance from Property: 0.41 mi. (2,165 ft.) NE Elevation: 4,239 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000940LUST FACILITY ID: 4000940 FACILITY NAME: BASIN MARKETS #104 ADDRESS: 105 W 600 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: BASIN MARKETS ADDRESS: PO BOX 17333 HOLLADAY, UT 84117 FACILITY DETAILS PROJECT MANAGER: HONG LEI TAO NOTIFICATION DATE: 3/2/2009 CLOSED DATE: 2/9/2012 ----------------------- PROJECT MANAGER: [DOUG HANSEN] NOTIFICATION DATE: 6/8/1993 CLOSED DATE: 1/15/1999 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: VAPORS/ODORS Back to Report Summary 156 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 49 Distance from Property: 0.41 mi. (2,165 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001539LUST FACILITY ID: 4001539 FACILITY NAME: UNISOURCE ADDRESS: 1000 S 500 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: UNISOURCE ADDRESS: 1000 S 500 W SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [EVAN SULLIVAN] NOTIFICATION DATE: 11/8/1989 CLOSED DATE: 12/23/1994 CAUSE AND RELEASE CAUSE OF RELEASE: HOLE IN TANK; SPILLAGE/LEAKAGE NEAR DISPENSERS SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: HOLE IN TANK; SPILLAGE/LEAKAGE NEAR DISPENSERS SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, 602, 8020/8015 MOD Back to Report Summary 157 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 50 Distance from Property: 0.42 mi. (2,218 ft.) W Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: VCP-C009 FACILITY ID: C009 FACILITY NAME: VAN WATERS AND ROGERS ADDRESS: 650 WEST 800 SOUTH SALT LAKE CITY, UT 84104 COUNTY: SALT LAKE STATUS: NOT REPORTED ACRES: NOT REPORTED AMENDED AGREEMENT DATE: NOT REPORTED ORIGINAL CERTIFICATE OF COMPLETION DATE: NOT REPORTED AMENDED CERTIFICATE OF COMPLETION DATE: NOT REPORTED EPA CERCLIS ARCHIVE DATE: NOT REPORTED TERMINATION DATE: 4/15/2003 PROJECT MANAGER: BILL REES NOTES: NOT REPORTED CERCLA BRANCH MAJOR ACTIVITIES MAJOR ACTIVITY STATE DESCRIPTION: APPLICANT TERMINATION START DATE: 4/15/2003 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT EXECUTED START DATE: 9/8/1998 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VOLUNTARY CLEANUP SITE APPLICATION RECEIVED START DATE: 12/10/1997 COMPLETION DATE: NOT REPORTED Back to Report Summary 158 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP) MAP ID# 51 Distance from Property: 0.42 mi. (2,218 ft.) N Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4000654LUST FACILITY ID: 4000654 FACILITY NAME: NEWSPAPER AGENCY CORP. GARAGE ADDRESS: 520 GALE ST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: NEWSPAPER AGENCY CORP ADDRESS: 143 S MAIN ST P O BOX 45838 SALT LAKE CITY, UT 84145 FACILITY DETAILS PROJECT MANAGER: UST NOTIFICATION DATE: 3/5/1998 CLOSED DATE: 3/11/1998 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 159 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST) MAP ID# 52 Distance from Property: 0.43 mi. (2,270 ft.) NE Elevation: 4,239 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001676LUST FACILITY ID: 4001676 FACILITY NAME: OLD RICK WARNER FORD SITE ADDRESS: 47 W 600 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SINCLAIR MARKETING, INC. /PAUL CONRAD ADDRESS: 333 WEST HAMPDEN STE 906 ENGLEWOOD, CO 80110 FACILITY DETAILS PROJECT MANAGER: [EVAN SULLIVAN] NOTIFICATION DATE: 12/11/1990 CLOSED DATE: 12/11/1997 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: SPILL/OVERFILL SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: OTHER METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, 8015 MOD Back to Report Summary 160 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 53 Distance from Property: 0.43 mi. (2,270 ft.) SE Elevation: 4,235 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000785LUST FACILITY ID: 4000785 FACILITY NAME: RAVARINO PRODUCE COMPANY, INC. ADDRESS: 1031 S WEST TEMPLE SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: HOUSING AUTHORITY OF SALT LAKE CITY ADDRESS: 1776 S WEST TEMPLE SALT LAKE CITY, UT 84115 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 1/11/2005 CLOSED DATE: 4/15/2005 ----------------------- PROJECT MANAGER: [ROBIN JENKINS] NOTIFICATION DATE: 11/14/1989 CLOSED DATE: 8/22/1995 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: UNKNOWN METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT Back to Report Summary 161 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 54 Distance from Property: 0.43 mi. (2,270 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000365LUST FACILITY ID: 4000365 FACILITY NAME: HARRY L. YOUNG & SONS ADDRESS: 542 W 600 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: HARRY L YOUNG & SONS INC ADDRESS: P O BOX 1104 SALT LAKE CITY, UT 84110 FACILITY DETAILS PROJECT MANAGER: KEVIN BEERY NOTIFICATION DATE: 2/19/1998 CLOSED DATE: NOT REPORTED ----------------------- PROJECT MANAGER: [DOUG HANSEN] NOTIFICATION DATE: 1/16/1991 CLOSED DATE: 8/31/1998 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: FP IN MW-3 Back to Report Summary 162 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 55 Distance from Property: 0.44 mi. (2,323 ft.) SE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: UTN000802626 DERR ID: UTN000802626 FACILITY NAME: RETEP 216 WEST PAXTON AVENUE PLUME ADDRESS: 216 WEST PAXTON AVE. SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE PROJECT MANAGER: KIM VIEHWEG CONTACT PHONE: 8015364161 PROJECT DESCRIPTION: UPDATE 01-07-09:THE SITE IS AN URBAN AREA CONSISTING OF MIXED INDUSTRIAL, COMMERCIAL, AND RESIDENTIAL USE, OCCUPYING APPROXIMATELY ONE ACRE. THE JORDAN RIVER IS LOCATED ONE MILE WEST OF THE SITE, AND THE GREAT SALT LAKE IS APPROXIMATELY SEVEN MILES NORTHWEST OF THE SITE. THE SITE IS ON PRIVATE PROPERTY, IS GATED AND LOCKED, AND IS NOT DIRECTLY ACCESSIBLE TO THE PUBLIC FROM THE STREET. CURRENTLY VACANT, THE MAIN OFFICE BUILDING AND REAR STORAGE AREA/GARAGE REMAIN ON THE PROPERTY. THE NEAREST RESIDENT IS SOMEWHAT MORE THAN 500 FEET FROM THE SITE. THERE ARE APPROXIMATELY 10,000 RESIDENTS LIVING WITHIN ONE MILE OF THE SITE.UNTIL CLOSING OPERATIONS IN 1989, THE RETEP BUSINESS STORED VARIOUS KINDS OF HAZARDOUS WASTES ON-SITE SUCH AS SPENT ELECTROPLATING METALS, SOLVENTS, AND DEGREASERS. EXISTING TANKS AND DRUMS WERE REMOVED BY THE OWNER IN 1994. ACCORDING TO SAMPLING RESULTS PERFORMED BY A PRIVATE CONSULTANT IN 2002, CHLORINATED SOLVENTS, INCLUDING VINYL CHLORIDE, TRICHLOROETHYLENE (TCE), AND TETRACHLOROETHYLENE (PCE), WERE DETECTED IN THE GROUNDWATER AT LEVELS ABOVE THEIR RESPECTIVE MCLS.VINYL CHLORIDE WAS DETECTED AT 307 PPB, TCE AT 43,200 PPB, AND PCE AT 355 PPB IN GROUNDWATER. DEPTH TO GROUNDWATER AS THE SITE IS BELIEVED TO BE LESS THAN 10 FEET BGS. CHLORINATED SOLVENTS WERE ALSO DETECTED IN ON-SITE SOILS.THERE ARE 34 MUNICIPAL DRINKING WATER SOURCES WITHIN FOUR MILES OF THE SITE. BECAUSE GROUNDWATER CONTAMINATION AT THIS SITE HAS BEEN DOCUMENTED, DERR CONSIDERS THE RETEP 216 W. PAXTON AVE. PLUME SITE A POTENTIAL HEALTH THREAT TO HUMAN POPULATIONS IN THE AREA VIA THE GROUNDWATER (DRINKING WATER) PATHWAY, AND RECOMMENDS FURTHER INVESTIGATION OF THE SITE UNDER THE CERCLA PROGRAM.THE SITE WAS DISCOVERED AND LISTED ON CERCLIS 02-08-06. THE DERR PRELIMINARY ASSESSMENT REPORT WAS APPROVED BY THE EPA ON 11-13-06. IF THE SITE MOVES ON TO THE SITE INVESTIGATION PHASE, A WORK PLAN WOULD BE THE FIRST THING PRODUCED EMERGENCY RESPONSE BRANCH: NO NATIONAL PRIORITY LIST: NO PROPOSED FOR NPL: NO ARCHIVED FOR CERCLIS: NO Back to Report Summary 163 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS) MAP ID# 55 Distance from Property: 0.44 mi. (2,323 ft.) SE Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTN000802626 SITE ID#: 0802626 NAME: RETEP 216 W. PAXTON AVE. PLUME ADDRESS: 216 W. PAXTON AVE. SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE FEDERAL FACILITY: N - NOT A FEDERAL FACILITY NPL: NOT ON THE NPL NON NPL STATUS: SI ONGOING Below information was gathered from the prior CERCLIS update completed in 10/2013 update: NON-NPL STATUS DATE: 07/02/09 PHYSICAL CLASSIFICATION OF SITE / INCIDENT: NO INFORMATION AVAILABLE SITE DESCRIPTION THE PROPERTY IDENTIFIED AT 216 W. PAXTON AVENUE IN A PHASE I AND II REPORT IS THE LOCATION OF THE FOMER RETEP FACILITY, A DISTRIBUTOR OF HALOGENATED SOLVENTS, SOLVENTS, LUBRICANTS AND EQUIPMENT FOR INDUSTRY. GROUNDWATER SAMPLES COLLECTED FOR THIS PHASE I & II REPORT DETECTED VARIOUS CHLORINATED SOLVENTS CONTAMINATING THE GROUNDWATER AT LEVELS WELL ABOVE THE MCL BENCHMARKS. SITE IS CURRENTLY VACANT WITH THE MAIN BUILDING AND REAR STORAGE AREA/GARAGE REMAINING ON THE PROPERTY. SITE HISTORY - NO SITE HISTORY INFORMATION AVAILABLE - ACTIONS TYPE: DS - DISCOVERY START DATE: NOT REPORTED COMPLETION DATE: 02/08/2006 ACTION TYPE DEFINITION: THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. TYPE: PA - PRELIMINARY ASSESSMENT START DATE: NOT REPORTED COMPLETION DATE: 11/13/2006 ACTION TYPE DEFINITION: COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. CONTAMINANTS - NO CONTAMINATION INFORMATION AVAILABLE - LISTING OF PUBLISHED INSTITUTIONAL CONTROL SITE REPORT - NOT AN INSTITUTIONAL CONTROL SITE - Back to Report Summary 164 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS) MAP ID# 56 Distance from Property: 0.44 mi. (2,323 ft.) N Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4002244LUST FACILITY ID: 4002244 FACILITY NAME: ALBERTO'S MOLCASALSA ADDRESS: 511 SOUTH 300 WEST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: LARRY WILKINS ADDRESS: 3243 E MCKELL COURT SALT LAKE CITY, UT 84121 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 3/23/1999 CLOSED DATE: 10/12/1999 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: UNKNOWN METHOD DETERMINED: NOT INDICATED/UNKNOWN Back to Report Summary 165 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST) MAP ID# 57 Distance from Property: 0.46 mi. (2,429 ft.) N Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4002214LUST FACILITY ID: 4002214 FACILITY NAME: FORMER A-1 PIONEER STORAGE ADDRESS: 471 W 500 S SALT LAKE CITY, UT 84113 COUNTY: SALT LAKE OWNER NAME: SALT LAKE CITY FLEET MANAGEMENT ADDRESS: 1990 W 500 S SALT LAKE CITY, UT 84104 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 10/16/1998 CLOSED DATE: 12/15/1999 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: HEATING OIL METHOD DETERMINED: PERMANENT CLOSURE Back to Report Summary 166 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 58 Distance from Property: 0.47 mi. (2,482 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: UTD980635585 DERR ID: UTD980635585 FACILITY NAME: MORRIS P. KIRK PLT CRD ADDRESS: 977 SOUTH 700 WEST SALT LAKE CITY, UT 84104 COUNTY: SALT LAKE PROJECT MANAGER: NOT REPORTED CONTACT PHONE: NOT REPORTED PROJECT DESCRIPTION: NOT REPORTED EMERGENCY RESPONSE BRANCH: NO NATIONAL PRIORITY LIST: NO PROPOSED FOR NPL: NO ARCHIVED FOR CERCLIS: YES Back to Report Summary 167 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS) MAP ID# 58 Distance from Property: 0.47 mi. (2,482 ft.) SW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: UTD980635585 SITE ID#: 0800667 NAME: MORRIS P. KIRK PLT/CRD ADDRESS: 977 SOUTH 700 WEST SALT LAKE CITY, UT 84104 COUNTY: SALT LAKE FEDERAL FACILITY: NOT A FEDERAL FACILITY NPL: NOT ON THE NPL NON NPL STATUS: NFRAP-SITE DOES NOT QUALIFY FOR THE NPL BASED ON EXISTING INFORMATION Below information was gathered from the prior NFRAP update completed in 10/2013 update: ACTION START DATE COMPLETION DATE RESPONSIBILITY DS - DISCOVERY NOT REPORTED 6/1/1981 EPA FUND PA - PRELIMINARY ASSESSMENT NOT REPORTED 2/28/1985 EPA FUND VS - ARCHIVE SITE NOT REPORTED 2/28/1985 EPA IN-HOUSE ACTION DESCRIPTIONS DS - (DISCOVERY) - THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. PA - (PRELIMINARY ASSESSMENT) - COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. VS - (ARCHIVE SITE) - THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE. Back to Report Summary 168 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH) MAP ID# 59 Distance from Property: 0.49 mi. (2,587 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: VCP-C060 FACILITY ID: C060 FACILITY NAME: 300 WEST TOWN CENTER ADDRESS: 1200 SOUTH 300 WEST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE STATUS: NOT REPORTED ACRES: NOT REPORTED AMENDED AGREEMENT DATE: 1/29/2013 ORIGINAL CERTIFICATE OF COMPLETION DATE: 7/23/2013 AMENDED CERTIFICATE OF COMPLETION DATE: NOT REPORTED EPA CERCLIS ARCHIVE DATE: NOT REPORTED TERMINATION DATE: NOT REPORTED PROJECT MANAGER: JOSEPH KATZ NOTES: NOT REPORTED CERCLA BRANCH MAJOR ACTIVITIES MAJOR ACTIVITY STATE DESCRIPTION: COC ISSUED START DATE: 7/23/2013 COMPLETION DATE: 7/23/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: ENVIRONMENTAL COVENANT RECEIVED START DATE: 7/3/2013 COMPLETION DATE: 7/3/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: ENVIRONMENTAL COVENANT RECORDED START DATE: 7/2/2013 COMPLETION DATE: 7/2/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: ENVIRONMENTAL COVENANT EXECUTED/ACCEPTED START DATE: 7/2/2013 COMPLETION DATE: 7/2/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: SITE MANAGEMENT PLAN ACCEPTED START DATE: 5/30/2013 COMPLETION DATE: 5/30/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT AMENDED START DATE: 1/29/2013 COMPLETION DATE: 1/29/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK 169 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP) START DATE: 1/8/2013 COMPLETION DATE: 1/9/2013 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: COC REQUESTED START DATE: 10/31/2012 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 10/2/2012 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 7/11/2012 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 4/3/2012 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: RISK ASSESSMENT REPORT RECEIVED START DATE: 2/3/2012 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 1/24/2012 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION FIELD WORK START DATE: 1/24/2012 COMPLETION DATE: 1/25/2012 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION REPORT RECEIVED START DATE: 11/23/2011 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 10/12/2011 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 7/19/2011 COMPLETION DATE: NOT REPORTED ----------------------- 170 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP) MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION FIELD WORK START DATE: 7/19/2011 COMPLETION DATE: 7/20/2011 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 4/19/2011 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 1/10/2011 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 9/28/2010 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION FIELD WORK START DATE: 9/22/2010 COMPLETION DATE: 9/30/2010 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING WORK PLAN RECEIVED START DATE: 9/13/2010 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 11/12/2009 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 8/27/2009 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 5/28/2009 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 2/26/2009 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: GROUND WATER MONITORING FIELD WORK START DATE: 9/26/2008 COMPLETION DATE: NOT REPORTED 171 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP) ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: SITE CHARACTERIZATION FIELD WORK START DATE: 9/24/2008 COMPLETION DATE: 9/26/2008 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION WORK PLAN ACCEPTED START DATE: 9/4/2008 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: PUBLIC COMMENT PERIOD START DATE: 7/28/2008 COMPLETION DATE: 8/28/2008 ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION WORK PLAN RECEIVED START DATE: 7/3/2008 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION WORK PLAN RESPONSE RECEIVED START DATE: 7/3/2008 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: REMEDIAL ACTION WORK PLAN COMMENTS SENT START DATE: 6/20/2008 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: ENVIRONMENTAL ASSESSMENT COMMENTS SENT START DATE: 2/8/2008 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: SITE CHARACTERIZATION REPORT RECEIVED START DATE: 12/18/2007 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VCP AGREEMENT EXECUTED START DATE: 12/11/2007 COMPLETION DATE: NOT REPORTED ----------------------- MAJOR ACTIVITY STATE DESCRIPTION: VOLUNTARY CLEANUP SITE APPLICATION RECEIVED START DATE: 10/19/2007 COMPLETION DATE: NOT REPORTED Back to Report Summary 172 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP) MAP ID# 59 Distance from Property: 0.47 mi. (2,482 ft.) S Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000696LUST FACILITY ID: 4000696 FACILITY NAME: PETROLEUM EQUIPMENT CO. ADDRESS: 1174 S 300 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: PETROLEUM EQUIPMENT CO ADDRESS: 1174 S 300 W SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: HONG LEI TAO NOTIFICATION DATE: 12/2/1999 CLOSED DATE: 12/3/2003 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 173 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST) MAP ID# 60 Distance from Property: 0.47 mi. (2,482 ft.) SE Elevation: 4,236 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001587LUST FACILITY ID: 4001587 FACILITY NAME: BORDEN INC., MEADOW GOLD DAIRY ADDRESS: 1030 S MAIN ST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: BORDEN INC ADDRESS: 1050 KINGSMILL PARKWAY COLUMBUS, OH 43229 FACILITY DETAILS PROJECT MANAGER: [ROBIN JENKINS] NOTIFICATION DATE: 3/16/2000 CLOSED DATE: 5/1/2000 ----------------------- PROJECT MANAGER: [ROBIN JENKINS] NOTIFICATION DATE: 3/20/1990 CLOSED DATE: 4/29/1996 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT Back to Report Summary 174 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 61 Distance from Property: 0.48 mi. (2,534 ft.) NE Elevation: 4,242 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4000098LUST FACILITY ID: 4000098 FACILITY NAME: PHILLIPS 66 CO # 28025 ADDRESS: 179 W 500 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: CK MANAGEMENT LLC ADDRESS: 2089 E FORT UNION BLVD SALT LAKE CITY, UT 84121 FACILITY DETAILS PROJECT MANAGER: [DOUG HANSEN] NOTIFICATION DATE: 7/7/2000 CLOSED DATE: 8/25/2004 ----------------------- PROJECT MANAGER: [DOUG HANSEN] NOTIFICATION DATE: 4/21/1996 CLOSED DATE: 5/11/1996 CAUSE AND RELEASE CAUSE OF RELEASE: OVERFILL PROTECTION FAILURE SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT Back to Report Summary 175 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 62 Distance from Property: 0.48 mi. (2,534 ft.) N Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4001517LUST FACILITY ID: 4001517 FACILITY NAME: OLD WHITFIELD TRANSPORTATION ADDRESS: 414 W 500 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: GEORGE CLARK ADDRESS: 600 W 557 S SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 8/30/1989 CLOSED DATE: NOT REPORTED CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: OTHER: 8020/8015 MOD CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: OTHER: 8020/8015 MOD CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 176 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 63 Distance from Property: 0.48 mi. (2,534 ft.) SW Elevation: 4,226 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001141LUST FACILITY ID: 4001141 FACILITY NAME: UNION POINT CONSTRUCTION COMPANY ADDRESS: 1132 S 500 W SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: UNION COMMERCIAL CORPORATION ADDRESS: 1132 S 500 W SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [EVAN SULLIVAN] NOTIFICATION DATE: 6/23/1994 CLOSED DATE: 3/14/1995 CAUSE AND RELEASE CAUSE OF RELEASE: SPILL/OVERFILL OF 1000 GAL USED OIL TANK SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: VISUAL:SOILS SATURATED & STAINED Back to Report Summary 177 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 64 Distance from Property: 0.48 mi. (2,534 ft.) E Elevation: 4,239 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001898LUST FACILITY ID: 4001898 FACILITY NAME: MASTER MUFFLER ADDRESS: 690 S MAIN SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: QUALITY OIL CO, ATTN: NED CALLISTER ADDRESS: 5445 S HIGHLAND DR #10 SALT LAKE CITY, UT 84117 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 5/8/2000 CLOSED DATE: 7/7/2000 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: NOT REPORTED Back to Report Summary 178 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 65 Distance from Property: 0.48 mi. (2,534 ft.) N Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4000048LUST FACILITY ID: 4000048 FACILITY NAME: A & Z PRODUCE CO ADDRESS: 380 W 500 S SALT LAKE CITY, UT 84110 COUNTY: SALT LAKE OWNER NAME: A & Z PRODUCE CO ADDRESS: P O BOX 1782 SALT LAKE CITY, UT 84110 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 11/3/1998 CLOSED DATE: 11/20/2013 ----------------------- PROJECT MANAGER: [SHELLY QUICK] NOTIFICATION DATE: 10/30/1990 CLOSED DATE: 7/3/1995 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE SAMPLES Back to Report Summary 179 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 66 Distance from Property: 0.49 mi. (2,587 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4000514LUST FACILITY ID: 4000514 FACILITY NAME: ALL RESORT COACH INC. ADDRESS: 549 W 500 S SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: ALL RESORT COACH INC. ADDRESS: 549 W 500 S SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [DALE URBAN] NOTIFICATION DATE: 2/22/2006 CLOSED DATE: 6/18/2007 ----------------------- PROJECT MANAGER: ROBIN DAVIS NOTIFICATION DATE: 2/22/2006 CLOSED DATE: 9/5/2006 ----------------------- PROJECT MANAGER: JOHN MENATTI NOTIFICATION DATE: 4/20/1992 CLOSED DATE: 12/6/2000 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: DIESEL METHOD DETERMINED: PERMANENT CLOSURE SAMPLES Back to Report Summary 180 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 67 Distance from Property: 0.49 mi. (2,587 ft.) E Elevation: 4,239 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001719LUST FACILITY ID: 4001719 FACILITY NAME: LELIS TRANSMISSIONS ADDRESS: 845 S MAIN SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: LELIS AUTOMATIC TRANSMISSION ADDRESS: 845 S MAIN SALT LAKE CITY, UT 84111 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 5/14/1991 CLOSED DATE: NOT REPORTED CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, 8015 M Back to Report Summary 181 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 67 Distance from Property: 0.49 mi. (2,587 ft.) E Elevation: 4,239 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4001420LUST FACILITY ID: 4001420 FACILITY NAME: COMMERCIAL PROPANE ADDRESS: 865 S MAIN ST SALT LAKE CITY, UT 84111 COUNTY: SALT LAKE OWNER NAME: GORDON F CROFTS ADDRESS: 242 S 200 E SALT LAKE CITY, UT 84111 FACILITY DETAILS PROJECT MANAGER: [DEANN RASMUSSEN] NOTIFICATION DATE: 8/30/1996 CLOSED DATE: 10/21/1996 CAUSE AND RELEASE CAUSE OF RELEASE: SPILL/OVERFILL & CORRODED TANKS - 7 TANKS WERE REM SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: SPILL/OVERFILL & CORRODED TANKS - 7 TANKS WERE REM SUBSTANCE RELEASE: OTHER:NEW OIL/LUBE OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: SPILL/OVERFILL & CORRODED TANKS - 7 TANKS WERE REM SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: NOT REPORTED CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: ANALY Back to Report Summary 182 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 68 Distance from Property: 0.49 mi. (2,587 ft.) N Elevation: 4,249 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 4002343LUST FACILITY ID: 4002343 FACILITY NAME: SHERATON HOTEL ADDRESS: 150 WEST 500 SOUTH SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: SUNSTONE HOTEL INVESTORS ADDRESS: 903 CALLE AMANECER STE 100 SAN CLEMENTE, CA 92673 FACILITY DETAILS PROJECT MANAGER: MORGAN ATKINSON NOTIFICATION DATE: 6/30/2003 CLOSED DATE: 4/16/2004 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: UNKNOWN METHOD DETERMINED: ENVIRONMENTAL ASSESSMENT Back to Report Summary 183 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 69 Distance from Property: 0.5 mi. (2,640 ft.) NW Elevation: 4,229 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 4001788LUST FACILITY ID: 4001788 FACILITY NAME: KIRBY WAREHOUSE ADDRESS: 651 W 600 S SALT LAKE CITY, UT 84115 COUNTY: SALT LAKE OWNER NAME: KIRBY COMPANY ADDRESS: 1639 S STATE SALT LAKE CITY, UT 84115 FACILITY DETAILS PROJECT MANAGER: JOHN MENATTI NOTIFICATION DATE: 8/28/1991 CLOSED DATE: 12/3/1999 CAUSE AND RELEASE CAUSE OF RELEASE: TANK FAILURE-CORROSION SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NOT REPORTED METHOD DETERMINED: REMOVAL, 8020/8015, 602 Back to Report Summary 184 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 70 Distance from Property: 0.5 mi. (2,640 ft.) SE Elevation: 4,232 ft. (Equal to TP) FACILITY INFORMATION GEOSEARCH ID: 4000138LUST FACILITY ID: 4000138 FACILITY NAME: CARLESON CADILLAC CO. INC. ADDRESS: 1070 S MAIN ST SALT LAKE CITY, UT 84101 COUNTY: SALT LAKE OWNER NAME: CARLESON CADILLAC CO INC ADDRESS: 1070 S MAIN SALT LAKE CITY, UT 84101 FACILITY DETAILS PROJECT MANAGER: [SHELLY QUICK] NOTIFICATION DATE: 7/10/1990 CLOSED DATE: 10/12/1993 CAUSE AND RELEASE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: GASOLINE METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: USED OIL METHOD DETERMINED: PERMANENT CLOSURE CAUSE OF RELEASE: UNKNOWN SUBSTANCE RELEASE: NEW OIL METHOD DETERMINED: PERMANENT CLOSURE Back to Report Summary 185 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) This list contains sites that could not be mapped due to limited or incomplete address information. Database Name Site ID#Site Name Address City/State/Zip/County ERNSUT 555253 SITE SPECIFIC 5600 W. 900 SOUTH SALT LAKE CITY 186 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites Summary AIRSAFS Aerometric Information Retrieval System / Air Facility Subsystem VERSION DATE: 10/20/14 The United States Environmental Protection Agency (EPA) modified the Aerometric Information Retrieval System (AIRS) to a database that exclusively tracks the compliance of stationary sources of air pollution with EPA regulations: the Air Facility Subsystem (AFS). Since this change in 2001, the management of the AIRS/AFS database was assigned to EPA's Office of Enforcement and Compliance Assurance. BRS Biennial Reporting System VERSION DATE: 12/31/11 The United States Environmental Protection Agency (EPA), in cooperation with the States, biennially collects information regarding the generation, management, and final disposition of hazardous wastes regulated under the Resource Conservation and Recovery Act of 1976 (RCRA), as amended. The Biennial Report captures detailed data on the generation of hazardous waste from large quantity generators and data on waste management practices from treatment, storage and disposal facilities. Currently, the EPA states that data collected between 1991 and 1997 was originally a part of the defunct Biennial Reporting System and is now incorporated into the RCRAInfo data system. CDL Clandestine Drug Laboratory Locations VERSION DATE: 01/20/16 The U.S. Department of Justice ("the Department") provides this information as a public service. It contains addresses of some locations where law enforcement agencies reported they found chemicals or other items that indicated the presence of either clandestine drug laboratories or dumpsites. In most cases, the source of the entries is not the Department, and the Department has not verified the entry and does not guarantee its accuracy. Members of the public must verify the accuracy of all entries by, for example, contacting local law enforcement and local health departments. The Department does not establish, implement, enforce, or certify compliance with clean-up or remediation standards for contaminated sites; the public should contact a state or local health department or environmental protection agency for that information. DOCKETS EPA Docket Data VERSION DATE: 12/22/05 The United States Environmental Protection Agency Docket data lists Civil Case Defendants, filing dates as far back as 1971, laws broken including section, violations that occurred, pollutants involved, penalties assessed and superfund awards by facility and location. Please refer to ICIS database as source of current data. EC Federal Engineering Institutional Control Sites VERSION DATE: 08/03/15 This database includes site locations where Engineering and/or Institutional Controls have been identified as part 187 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL of a selected remedy for the site as defined by United States Environmental Protection Agency official remedy decision documents. A site listing does not indicate that the institutional and engineering controls are currently in place nor will be in place once the remedy is complete; it only indicates that the decision to include either of them in the remedy is documented as of the completed date of the document. Institutional controls are actions, such as legal controls, that help minimize the potential for human exposure to contamination by ensuring appropriate land or resource use. Engineering controls include caps, barriers, or other device engineering to prevent access, exposure, or continued migration of contamination. ERNSUT Emergency Response Notification System VERSION DATE: 02/21/16 This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. FRSUT Facility Registry System VERSION DATE: 02/03/16 The United States Environmental Protection Agency's Office of Environmental Information (OEI) developed the Facility Registry System (FRS) as the centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. The Facility Registry System replaced the Facility Index System or FINDS database. HMIRSR08 Hazardous Materials Incident Reporting System VERSION DATE: 11/08/15 The HMIRS database contains unintentional hazardous materials release information reported to the U.S. Department of Transportation located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. ICIS Integrated Compliance Information System (formerly DOCKETS) VERSION DATE: 12/06/15 ICIS is a case activity tracking and management system for civil, judicial, and administrative federal Environmental Protection Agency enforcement cases. ICIS contains information on federal administrative and federal judicial cases under the following environmental statutes: the Clean Air Act, the Clean Water Act, the Resource Conservation and Recovery Act, the Emergency Planning and Community Right-to-Know Act - Section 313, the Toxic Substances Control Act, the Federal Insecticide, Fungicide, and Rodenticide Act, the Comprehensive Environmental Response, Compensation, and Liability Act, the Safe Drinking Water Act, and the Marine Protection, Research, and Sanctuaries Act. 188 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL ICISNPDES Integrated Compliance Information System National Pollutant Discharge Elimination System VERSION DATE: 12/20/15 In 2006, the Integrated Compliance Information System (ICIS) - National Pollutant Discharge Elimination System (NPDES) became the NPDES national system of record for select states, tribes and territories. ICIS-NPDES is an information management system maintained by the United States Environmental Protection Agency's Office of Compliance to track permit compliance and enforcement status of facilities regulated by the NPDES under the Clean Water Act. ICIS-NPDES is designed to support the NPDES program at the state, regional, and national levels. LUCIS Land Use Control Information System VERSION DATE: 09/01/06 The LUCIS database is maintained by the U.S. Navy and contains information for former Base Realignment and Closure (BRAC) properties across the United States. MLTS Material Licensing Tracking System VERSION DATE: 02/12/16 MLTS is a list of approximately 8,100 sites which have or use radioactive materials subject to the United States Nuclear Regulatory Commission (NRC) licensing requirements. NPDESR08 National Pollutant Discharge Elimination System VERSION DATE: 04/01/07 Information in this database is extracted from the Water Permit Compliance System (PCS) database which is used by United States Environmental Protection Agency to track surface water permits issued under the Clean Water Act. This database includes permitted facilities located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. The NPDES database was collected from December 2002 until April 2007. Refer to the PCS and/or ICIS-NPDES database as source of current data. PADS PCB Activity Database System VERSION DATE: 07/01/14 The PCB Activity Database System (PADS) is used by the United States Environmental Protection Agency to monitor the activities of polychlorinated biphenyls (PCB) handlers. PCSR08 Permit Compliance System VERSION DATE: 08/01/12 189 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL The Permit Compliance System is used in tracking enforcement status and permit compliance of facilities controlled by the National Pollutant Discharge Elimination System (NPDES) under the Clean Water Act and is maintained by the United States Environmental Protection Agency's Office of Compliance. PCS is designed to support the NPDES program at the state, regional, and national levels. This database includes permitted facilities located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. PCS has been modernized, and no longer exists. National Pollutant Discharge Elimination System (ICIS-NPDES) data can now be found in Integrated Compliance Information System (ICIS). RCRASC RCRA Sites with Controls VERSION DATE: 02/23/16 This list of Resource Conservation and Recovery Act sites with institutional controls in place is provided by the U.S. Environmental Protection Agency. SFLIENS CERCLIS Liens VERSION DATE: 06/08/12 A Federal CERCLA ("Superfund") lien can exist by operation of law at any site or property at which United States Environmental Protection Agency has spent Superfund monies. These monies are spent to investigate and address releases and threatened releases of contamination. CERCLIS provides information as to the identity of these sites and properties. This database contains those CERCLIS sites where the Lien on Property action is complete. SSTS Section Seven Tracking System VERSION DATE: 12/08/14 The United States Environmental Protection Agency tracks information on pesticide establishments through the Section Seven Tracking System (SSTS). SSTS records the registration of new establishments and records pesticide production at each establishment. The Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) requires that production of pesticides or devices be conducted in a registered pesticide-producing or device- producing establishment. ("Production" includes formulation, packaging, repackaging, and relabeling.) TRI Toxics Release Inventory VERSION DATE: 12/31/14 The Toxics Release Inventory, provided by the United States Environmental Protection Agency, includes data on toxic chemical releases and waste management activities from certain industries as well as federal and tribal facilities. This inventory contains information about the types and amounts of toxic chemicals that are released each year to the air, water, and land as well as information on the quantities of toxic chemicals sent to other facilities for further waste management. 190 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL TSCA Toxic Substance Control Act Inventory VERSION DATE: 12/31/06 The Toxic Substances Control Act (TSCA) was enacted in 1976 to ensure that chemicals manufactured, imported, processed, or distributed in commerce, or used or disposed of in the United States do not pose any unreasonable risks to human health or the environment. TSCA section 8(b) provides the United States Environmental Protection Agency authority to "compile, keep current, and publish a list of each chemical substance that is manufactured or processed in the United States." This TSCA Chemical Substance Inventory contains non-confidential information on the production amount of toxic chemicals from each manufacturer and importer site. NLRRCRAG No Longer Regulated RCRA Generator Facilities VERSION DATE: 02/09/16 This database includes RCRA Generator facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly generated hazardous waste. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. RCRAGR08 Resource Conservation & Recovery Act - Generator Facilities VERSION DATE: 02/09/16 This database includes sites listed as generators of hazardous waste (large, small, and exempt) in the RCRAInfo 191 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). This database includes sites located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. RCRANGR08 Resource Conservation & Recovery Act - Non-Generator Facilities VERSION DATE: 02/09/16 This database identifies RCRAInfo system sites that only handle hazardous waste, such as transporters, without generating any amount hazardous waste. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). This database includes sites located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. HISTPST Historical Gas Stations VERSION DATE: NR This historic directory of service stations is provided by the Cities Service Company. The directory includes 192 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL Cities Service filling stations that were located throughout the United States in 1930. BF Brownfields Management System VERSION DATE: 01/28/16 Brownfields are real property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant. Cleaning up and reinvesting in these properties takes development pressures off of undeveloped, open land, and both improves and protects the environment. The United States Environmental Protection Agency maintains this database to track activities in the various brown field grant programs including grantee assessment, site cleanup and site redevelopment. This database included tribal brownfield sites. DNPL Delisted National Priorities List VERSION DATE: 07/22/15 This database includes sites from the United States Environmental Protection Agency’s Final National Priorities List (NPL) where remedies have proven to be satisfactory or sites where the original analyses were inaccurate, and the site is no longer appropriate for inclusion on the NPL, and final publication in the Federal Register has occurred. NLRRCRAT No Longer Regulated RCRA Non-CORRACTS TSD Facilities VERSION DATE: 02/09/16 This database includes RCRA Non-Corrective Action TSD facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly treated, stored or disposed of hazardous waste. ODI Open Dump Inventory VERSION DATE: 06/01/85 The open dump inventory was published by the United States Environmental Protection Agency. An “open dump” is defined as a facility or site where solid waste is disposed of which is not a sanitary landfill which meets the criteria promulgated under section 4004 of the Solid Waste Disposal Act (42 U.S.C. 6944) and which is not a facility for disposal of hazardous waste. This inventory has not been updated since June 1985. RCRAT Resource Conservation & Recovery Act - Non-CORRACTS Treatment, Storage & Disposal Facilities VERSION DATE: 02/09/16 This database includes Non-Corrective Action sites listed as treatment, storage and/or disposal facilities of hazardous waste in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 193 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). SEMS Superfund Enterprise Management System VERSION DATE: 03/07/16 The U.S. Environmental Protections Agency's (EPA) Office of Solid Waste and Emergency Response, Office of Superfund Remediation and Technology Innovation (OSRTI), has implemented The Superfund Enterprise Management System (SEMS), formerly known as CERCLIS (Comprehensive Environmental Response, Compensation and Liability Information System) to track and report on clean-up and enforcement activities taking place at Superfund sites. SEMS represents a joint development and ongoing collaboration between Superfund's Remedial, Removal, Federal Facilities, Enforcement and Emergency Response programs. SEMSARCH Superfund Enterprise Management System Archived Site Inventory VERSION DATE: 03/16/16 The Superfund Enterprise Management System Archive listing (SEMS-ARCHIVE) has replaced the CERCLIS NFRAP reporting system in 2015. This listing reflect sites that have been assessed and no further remediation is planned and is of no further interest under the Superfund program. DOD Department of Defense Sites VERSION DATE: 06/21/10 This information originates from the National Atlas of the United States Federal Lands data, which includes lands owned or administered by the Federal government. Army DOD, Army Corps of Engineers DOD, Air Force DOD, Navy DOD and Marine DOD areas of 640 acres or more are included. FUDS Formerly Used Defense Sites VERSION DATE: 06/01/15 The Formerly Used Defense Sites (FUDS) inventory includes properties previously owned by or leased to the United States and under Secretary of Defense Jurisdiction, as well as Munitions Response Areas (MRAs). The remediation of these properties is the responsibility of the Department of Defense. This data is provided by the U.S. Army Corps of Engineers (USACE), the boundaries/polygon data are based on preliminary findings and not all properties currently have polygon data available. DISCLAIMER: This data represents the results of data collection/processing for a specific USACE activity and is in no way to be considered comprehensive or to be used in any legal or official capacity as presented on this site. While the USACE has made a reasonable effort to insure the accuracy of the maps and associated data, it should be explicitly noted that USACE makes no warranty, representation or guaranty, either expressed or implied, as to the content, sequence, accuracy, timeliness or completeness of any of the data provided herein. For additional information on Formerly Used Defense Sites please contact the USACE Public Affairs Office at (202) 528-4285. 194 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL NLRRCRAC No Longer Regulated RCRA Corrective Action Facilities VERSION DATE: 02/09/16 This database includes RCRA Corrective Action facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. NPL National Priorities List VERSION DATE: 12/15/15 This database includes United States Environmental Protection Agency (EPA) National Priorities List sites that fall under the EPA's Superfund program, established to fund the cleanup of the most serious uncontrolled or abandoned hazardous waste sites identified for possible long-term remedial action. PNPL Proposed National Priorities List VERSION DATE: 07/22/15 This database contains sites proposed to be included on the National Priorities List (NPL) in the Federal Register. The United States Environmental Protection Agency investigates these sites to determine if they may present long-term threats to public health or the environment. RCRAC Resource Conservation & Recovery Act - Corrective Action Facilities VERSION DATE: 02/09/16 This database includes all hazardous waste sites with ongoing corrective action activity and where corrective action is statutorily required to be address but have not had corrective action imposed in the RCRAInfo system. The Corrective Action Program requires owners or operators of RCRA facilities (or treatment, storage, and disposal facilities) to investigate and cleanup contamination in order to protect human health and the environment. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). RCRASUBC Resource Conservation & Recovery Act - Subject to Corrective Action Facilities VERSION DATE: 02/09/16 This database includes hazardous waste sites which are potentially subject to corrective action regardless of whether they have correction action underway, plus any sites showing a corrective action event of RFI or beyond in the RCRAInfo system. Sites conducting corrective action under analogous state authorities are also included. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and 195 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). RODS Record of Decision System VERSION DATE: 07/01/13 These decision documents maintained by the United States Environmental Protection Agency describe the chosen remedy for NPL (Superfund) site remediation. They also include site history, site description, site characteristics, community participation, enforcement activities, past and present activities, contaminated media, the contaminants present, and scope and role of response action. 196 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL ICEC Institutional Engineering Controls Registry VERSION DATE: 02/23/16 The Utah Department of Environmental Quality is required to maintain a record of the properties subject to environmental covenants/institutional controls established under Utah Code, Title 19, Chapter 10. This list Leaking Underground Storage Tank sites, CERCLA/Superfund Branch Sites, and Voluntary Cleanup sites that have environmental controls established under this statute and pursuant to Utah Code Ann. §§ 57-25-101 et seq and controls established prior to the enactment of this statute. The controls have been recorded by the owner of the real property in the county recorder's office in the county where the real property is located. TIERII Tier II Facilities VERSION DATE: 12/03/15 This database contains locations of Tier II facilities under the Emergency Planning and Community Right-to- Know Act (EPCRA). This data is maintained by the Utah Department of Environmental Quality’s Division of Environmental Response and Remediation (DERR). The DERR assumes no responsibility or liability for the accuracy of the location of these facilities. This database also includes some Tier II facility information from the Utah Automated Geographic Reference Center (AGRC) for informational purposes. Qualifying facilities report on hazardous and toxic chemicals and are labeled either tier I or tier II. Locations are based on coordinates derived from maps and GPS data. These locations represent sites, not contaminated areas. RUST Registered Underground Storage Tanks VERSION DATE: 02/01/16 The Utah State Underground Storage Tank program of the Department of Environmental Quality provides this list of underground storage tank sites. BF Brownfield Properties VERSION DATE: 02/01/16 This database of brownfields (targeted) and other brownfield (non-targeted) properties is maintained by the Utah Department of Environmental Quality’s Division of Environmental Response and Remediation (DERR). Brownfields are real property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant. Cleaning up and reinvesting in these properties takes development pressures off of undeveloped open land, and both improves and protects the environment. The DERR assumes no responsibility or liability for the accuracy of the location of these properties. CERCLIS CERCLIS Sites VERSION DATE: 02/01/16 This database of Comprehensive Environmental Response, Compensation, and Liability System sites is 197 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (UT) maintained by the Utah Department of Environmental Quality’s Division of Environmental Response and Remediation (DERR). The CERCLA Branch of the DERR performs site investigations of potentially contaminated sites within the State of Utah to determine whether or not they pose a threat to human health and the environment and should be included on the Federal Superfund National Priorities List. The DERR assumes no responsibility or liability for the accuracy of the location of these properties. LFSWDS Landfill and Solid Waste Disposal Sites VERSION DATE: 02/29/16 This list of permitted solid waste facilities is provided by the Utah Department of Environmental Quality. LUST Leaking Underground Storage Tanks VERSION DATE: 02/01/16 The Utah State Underground Storage Tank program of the Department of Environmental Quality provides this list of leaking underground storage tank sites. The primary goal of this program is to protect human health and the environment from leaking underground storage tanks. The UST staff oversees UST notification, installation, inspection, removal, and compliance with State and Federal UST regulations concerning release prevention and remediation. VCP Voluntary Cleanup Program Sites VERSION DATE: 02/01/16 This list of Voluntary Cleanup Program sites is maintained by the Utah Department of Environmental Quality’s Division of Environmental Response and Remediation (DERR). The DERR assumes no responsibility or liability for the accuracy of the location of these facilities. In 1997, the Utah Voluntary Cleanup Program (VCP) was created to promote the voluntary cleanup of contaminated sites. The VCP is intended to encourage redevelopment of Brownfields and other impacted sites by providing a streamlined cleanup program. This database also includes some Voluntary Cleanup information from the Utah Automated Geographic Reference Center (AGRC) for informational purposes. Locations are based on coordinates derived from maps and GPS data. NPL National Priorities List VERSION DATE: 02/01/16 The National Priorities List (NPL) is provided by the Utah Department of Environmental Quality’s Division of Environmental Response and Remediation (DERR). Before a cleanup of a hazardous waste site can take place under Superfund, it must be included on the National Priority List . The NPL is a published list of hazardous waste sites that are eligible for extensive, long-term cleanup action under the Superfund program. When no responsible party can be found, listing on the NPL allows EPA and the State to access the Superfund Trust fund to pay for site cleanup. The DERR assumes no responsibility or liability for the accuracy of the location of these properties. 198 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (UT) 199 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (UT) USTR08 Underground Storage Tanks On Tribal Lands VERSION DATE: 04/01/15 This database, provided by the United States Environmental Protection Agency (EPA), contains underground storage tanks on Tribal lands located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. LUSTR08 Leaking Underground Storage Tanks On Tribal Lands VERSION DATE: 04/01/15 This database, provided by the United States Environmental Protection Agency (EPA), contains leaking underground storage tanks on Tribal lands located in EPA Region 8. This region includes the following states: Colorado, Montana, North Dakota, South Dakota, Utah, and Wyoming. ODINDIAN Open Dump Inventory on Tribal Lands VERSION DATE: 11/08/06 This Indian Health Service database contains information about facilities and sites on tribal lands where solid waste is disposed of, which are not sanitary landfills or hazardous waste disposal facilities, and which meet the criteria promulgated under section 4004 of the Solid Waste Disposal Act (42 U.S.C. 6944). INDIANRES Indian Reservations VERSION DATE: 01/01/00 The Department of Interior and Bureau of Indian Affairs maintains this database that includes American Indian Reservations, off-reservation trust lands, public domain allotments, Alaska Native Regional Corporations and Recognized State Reservations. 200 of 200 www.geo-search.com 888-396-0042 Order# 65948 Job# 143169 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryFacility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES) Integrated Compliance Information System National Pollutant Discharge Elimination System (ICISNPDES)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)No Longer Regulated RCRA Non-CORRACTS TSD Facilities (NLRRCRAT)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)Facility Registry System (FRSUT)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08) Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Facility Registry System (FRSUT)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)Brownfield Properties (BF)Resource Conservation & Recovery Act - Non-Generator Facilities (RCRANGR08)No Longer Regulated RCRA Generator Facilities (NLRRCRAG)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR08)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Registered Underground Storage Tanks (RUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Brownfield Properties (BF)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System (SEMS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)CERCLIS Sites (CERCLIS)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)Voluntary Cleanup Program Sites (VCP)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (UT)Environmental Records Definitions - TRIBAL insert PDFs below: APPENDIX E CREDENTIALS Geotechnical Ŷ Environmental Ŷ Construction Materials Ŷ Facilities NANCY SAUNDERS ENVIRONMENTAL SCIENTIST PROFESSIONAL EXPERIENCE Ms. Saunders is a geologist with expertise in conducting Phase I Environmental Site Assessments (ESAs). She has conducted over 100 assessments in conformance with current ASTM standards at a range of properties, including heavy industrial sites, airports, automotive repair facilities, and large tracts of raw land. In addition, she has had extensive experience investigating and evaluating environmental issues at many types of properties and has managed investigations and monitoring programs conducted at LUST, RCRA, and CERCLA facilities. She has been responsible for the preparation and implementation of Sampling and Analysis Plans and Quality Assurance Project Plans for large-scale Remedial Investigation/Feasibility Studies conducted under careful EPA and State of Utah scrutiny. These projects included soil and sediment sampling, monitoring well installation, groundwater sampling, and aquifer testing. PROJECT EXPERIENCE Airport Facility Phase I ESA Ms. Saunders participated in a Phase I ESA project for a general aviation fixed-based operations entity in Salt Lake City. The project involved evaluating over 40 separate facilities in support of a time-critical property transaction. The properties included sites with large-scale bulk fuel operations, regulated release sites, and military facilities with sensitive security requirements. The project was completed on time and allowed the prospective purchaser to evaluate risks associated with the transaction. Retail Fuel Outlets Phase I ESAs Ms. Saunders assisted in a fast turnaround Phase I project for a client interested in assessing twelve retail gas stations in three weeks. The assessments involved reviewing regulatory and compliance files for the tank systems. In addition, several of the properties were regulated as active release sites. Ogden Defense Depot CERCLA Site Ms. Saunders coordinated field investigation activities at a U.S. Army Depot in Ogden, Utah, during a Remedial Investigation/Feasibility Study. Soils and shallow groundwater were contaminated with chlorinated solvents, semi-volatile compounds and metals from past disposal practices at the Depot. This phase of the investigation included the installation of 25 shallow monitoring wells and 3 deeper monitoring wells, and soil sampling from borings and surface soils. Aquifer tests were conducted on the deeper wells and slug tests were performed on the shallow wells. Ms. Saunders oversaw the activities of two field crews and tracked and validated all data from the investigation. Education B.S., Geology, University of California, Santa Cruz, 1984 Certifications AHERA: Building Inspector Work History Terracon Consultants, Inc., Environmental Scientist, September 1, 2012-Present IHI Environmental, Inc., Senior Geologist, 1991-2012 J. M. Montgomery Consulting Engineers, Associate Hydrogeologist, 1988-1991 Harding Lawson Associates, Staff Geologist, 1987-1988 U. S. Forest Service, Field Geologist, Fall 1984 Geotechnical Ŷ Environmental Ŷ Construction Materials Ŷ Facilities Retail Shopping Center Methane Remediation During construction of a large retail shopping complex, construction workers ignited a pocket of methane gas that had accumulated in an elevator shaft jack hole. Ms. Saunders oversaw the investigation into the cause of the explosion, which consisted of installing and sampling twenty soil gas probes at the property, as well as at seven offsite locations. The investigation revealed a naturally occurring methane gas plume underneath a large area of the project site, with concentrations of methane well above explosive levels. The next phase of the project involved conducting pilot tests and overseeing the design of an extraction system. Because substantial work had already been completed at the shopping center, the design utilized existing and proposed infrastructure, where possible, to keep costs down and avoid disruption to the construction schedule. Ms. Saunders supervised the installation and operation of the remediation system, which was completed in five months, prior to the opening of the mall. Long term monitoring has been recommended for the site. Undeveloped Property A prospective developer was interested in the potential setbacks in developing a parcel of land in a commercial area of West Boise, Idaho. The property was immediately down-gradient of the source of a documented PCE groundwater plume that extended approximately three miles down-gradient of the subject property and had already impacted several private wells and threatened a municipal supply well. A major cleanup effort was in progress and was being overseen by Idaho DEQ. The owner was interested in developing the property but wanted to identify specific areas of liability that might be incurred. Soil vapors collecting inside structures built on the site, exposure to construction workers, and the need to discharge groundwater during construction, were three areas that seemed to present liability. Ms. Saunders developed a sampling plan to collect sufficient site-specific information to assess these potential issues. In addition, interviews were conducted with local and state regulators to identify additional issues pertaining to the development. Through this interview process, Ms. Saunders learned that surface water runoff in this area was not collected in a sewer system and would need to be handled some way by the developer. Typically, this was handled by construction of an infiltration lagoon on the property. However, IHI advised the developer that this practice could potentially alter the movement of the underlying PCE groundwater plume. IHI worked with a local design firm to evaluate several options for fulfilling the stormwater runoff requirements that would not impact the groundwater plume. Geotechnical Ŷ Environmental Ŷ Construction Materials Ŷ Facilities BENJAMIN B. BOWERS ENVIRONMENTAL DEPARTMENT MANAGER PROFESSIONAL EXPERIENCE Mr. Bowers is the Environmental Department Manager at Terracon’s Salt Lake City office. He has more than 15 years of valuable and proactive experience in the environmental, construction materials and geotechnical consulting fields. His experience includes Phase I, II, and III environmental site assessments (ESAs), National Environmental Policy Act (NEPA), Brownfields, subsurface investigations, remediation, asbestos inspections, construction materials testing, and geotechnical engineering. His expertise complements projects that require multiple consulting services and enhances the sharing of information and understanding between the environmental, construction materials, and geotechnical disciplines. Mr. Bowers has acted as project manager for numerous site investigations and remediation projects for petroleum distributors, Brownfield projects, municipalities, and commercial and industrial property owners. He has developed remedial action plans based upon the property owners’ objective and hydrogeologic conditions. Remedial actions included soil excavation, mechanical soil and groundwater treatment systems, in-situ bioremediation, oxidization, and natural attenuation. Mr. Bowers is responsible for the management and overview of over 100 environmental site assessments a year and has participated in more than 1,000 Phase I, Phase II, and remediation projects. Over his 15-year career, Mr. Bowers has personally completed hundreds of Phase I ESAs on a variety of sites, ranging from retail, industrial, residential, agricultural and undeveloped. PROJECT EXPERIENCE Phase I Environmental Site Assessments Norbest Foods – Various Sites - Utah Managed the completion of Phase I ESAs on 13 individual properties as part of a commercial refinancing portfolio for the property owner. The subject sites varied from vacant land, gasoline/service stations, food- processing facilities, and turkey farms. During the ESA process, numerous RECs were identified associated with leaking aboveground and underground storage tanks, oil spills originating from automotive maintenance on the sites and compressor blow-down. Mr. Bowers managed site soil remediation at three of the 13 sites and achieved no further action status for the releases. FDIC – Various Sites - Utah Served as technical reviewer for over 40 Phase I ESAs and Phase IIs. Sites included retail, office, commercial, industrial, proposed residential developments, and vacant properties. Education Bachelor of Science, Environmental Policy, St. Norbert College, 1998 Certifications 40-Hour OSHA Hazardous Wastes Operations Training, Utah (2000) State of Utah UST Certified Consultant, Utah CC 195 Certified UST Groundwater and Soil Sampler, Utah GS-1419 Nuclear Density Gauge Safety Training (1998) Affiliations Utah Alliance For Economic Development Work History Terracon Consultants, Inc. Environmental Service Line Dept. Manager, 2006 –Present Project Manager, 2004 – 2006 Staff Scientist, 2003-2004 PSI, Inc. Environmental Project Manager, 2002-2003 Giles Engineering Assoc., Inc., Staff Scientist, 1999-2002 CMT Field Technician 1998-1999 Geotechnical Ŷ Environmental Ŷ Construction Materials Ŷ Facilities BOWERS, BENJAMIN B. 2 In-N-Out Burgers – Various Sites – Utah, Nevada, California and Texas As the National Account Manager for In-N-Out Burgers located in California, Mr. Bowers has managed the completion of over 100 Phase I ESAs, Limited Site Investigations, and geotechnical investigations in Utah, Nevada, California, and Texas. Telecommunications Over 800 Towers for Telecommunication Firms– Utah, Idaho and Wyoming Managed the completion of Phase I ESAs, Section 106 and NEPA work for more than 800 cell tower sites for various cellular companies throughout the states of Utah, Idaho, and Wyoming. Clients include AT&T, Verizon Wireless, T-Mobile, Cricket, Sprint, and other telecommunication service companies, such as General Dynamics, Clearwire, Pacific Telecom Service, Overland, and Black & Veatch Company among others. UST/LUST Former Roadway Express Facility – Salt Lake City, Utah Project Manager for the investigation and remediation of the site after a failing leak detection test was reported on a new oil product line that serviced three fuel islands at the trucking terminal. During the investigation, new motor oil was detected above regulatory limits in the soil and groundwater on the site. Terracon prepared an Underground Storage Tank (UST) closure plan and closure notice before abandoning the oil product lines in-place. Soil sampling indicated widespread oil and diesel contamination along the product lines and dispensers. Mr. Bowers prepared a Corrective Action Plan (CAP) to excavate the petroleum-impacted soils. Approximately 720 tons of impacted soils were removed and disposed at a licensed facility. Terracon implemented a quarterly groundwater sampling program and was able to remediate soil and groundwater below regulatory limits and received no further action for the site release. At the same site, Mr. Bowers managed a Limited Site Investigation in the area of the on-site maintenance building and diesel tank farm that serviced the site and identified oil and diesel constituents above regulatory limits in the soil and groundwater. Terracon developed and completed a pilot test to determine the feasibility of full-scale anaerobic bioremediation using an oil digestant, BioRem 2000®. The pilot test included physical contaminant removal using vacuum-enhanced fluid recovery (VEFR) to remove vapor and dissolved and free-phase volatile organic compounds (VOCs) from the subsurface. Approximately 16,000-gallons of petroleum-impacted water was removed, treated on site with an air sparging system, and discharged under a one-time UPDES permit. Following the VEFR event, Terracon conducted injection events into 44 monitoring / injection wells for a total of three nutrient injections and two BioRem injections over a five-week period. TPH-DRO concentrations were reduced by 54% during the 35 day pilot test. Following the successful completion of the pilot test, Terracon was approved by the State to conduct full-scale remediation at the site. Upon approval from the state, approximately 280 tons of impacted soils were removed from the areas near dispensers. Free product (diesel) was discovered in several monitoring area surrounding the diesel tank farm. Injections were conducted on the site for approximately three years, after which Terracon was able to achieve no further action status for the release. 9th Street Marketplace Shopping Center – Former San Marcos Property – Murray, Utah The site was a former corner gasoline service station that was abandoned in the late 1960s. A local developer purchased the property with plans to develop the site within 180 days. Terracon conducted a Limited Site Investigation and it was determined that the soil and groundwater at the site were impacted with gasoline, used oil, and diesel constituents above Initial Screening Levels. In addition, trichloroethene (TCE) was detected above EPA National Primary Drinking Water Standards in a groundwater monitoring well on the perimeter of the site. It was later determined that the TCE had migrated on to the site from a nearby dry cleaners. Terracon met with members of the Division of Solid and Hazardous Waste to Geotechnical Ŷ Environmental Ŷ Construction Materials Ŷ Facilities BOWERS, BENJAMIN B. 3 discuss the chlorinated solvents in the groundwater, and devised a remediation plan to address the impacted soils and groundwater on the site. There was additional collaboration with the Division of Environmental Response and Remediation (DERR) on this remediation approach due to the petroleum hydrocarbons impacts and former USTs on the site. Due to the short time-frame for development, Terracon used a "dig and haul" approach to remediate the site. Approximately 1,150 tons of petroleum- impacted soils were excavated and disposed at ET Technologies Soil Regeneration site for land farming. Upon completion of remediation services, the site received a No Further Action letter from the DERR for the Leaking Underground Storage Tank (LUST) release. The DSHW provided a letter indicating that the TCE contamination appeared to be from an off-site source and no additional sampling was necessary. Tesoro #40 – South Salt Lake, Utah A release was discovered following the closure of three USTs in April 2008. Terracon is providing ongoing services for site characterization, vapor intrusion evaluation, groundwater monitoring and remediation. Using a phased site investigation approach, Terracon defined the vertical and lateral extent of impact to subsurface soils and groundwater. The site investigation determined that constituent concentrations exceeding applicable action levels (Tier 1 Screening Levels and Initial Screening Levels) extend from the source area down gradient to adjacent off-site properties. Of particular concern is an adjacent residential apartment building (down gradient from the source area) where elevated gasoline constituent concentrations are present in underlying soils and groundwater. To assess vapor intrusion (VI) potential, Terracon worked closely with DERR representatives (who are using this site as a VI case study) to conduct quarterly rounds of sub-slab soil vapor sampling through the basement floor of both of the affected apartments. This intrusive activity required proactive public relations directly with the affected apartment residents. The vapor analytical results were compared to risk-based screening levels (RBSLs) for indoor air, which Terracon calculated using the procedures in DERR’s Guidelines for Utah’s Corrective Action Process. The results indicated vapor concentrations below the calculated RBSLs, and therefore are not contributing to excess risk to the apartment residents. Terracon developed a Corrective Action Plan (CAP) including a detailed remedial alternatives evaluation, selection of the preferred remedy, and remedial design. The selected remedy involves in-situ anaerobic bioremediation along with source removal and disposal. The CAP was approved by DERR in 2010 and Terracon directed the removal of impacted soils in the area of the former USTs and installed a network of 30 injection wells on the site and adjoining residential property for the injection of an anaerobic oil digester. To date, Terracon has directed 18 injection events, and benzene concentrations have been reduced by more than 85% since the initiation of corrective action on the site. Construction Truck and Trailer – Salt Lake City, Utah Project Manager for the ongoing investigation/remediation project after a diesel UST and new oil AST leaked on the site. Mr. Bowers conducted a Limited Site Investigation and identified TRPH and diesel constituents above regulatory limits in the soil and groundwater of the site. Several of the wells located between the existing shop area and former UST had measurable levels of free product (new oil) in the wells. Terracon directed the excavation of an area approximately 90’ x 90’ x 8’ and 2,442 tons of impacted soil were disposed at a permitted disposal facility. Terracon is currently awaiting the approval of a Corrective Action Plan from the DERR and intends to remediate the remaining “hot spots” of soil and groundwater contamination that could not be excavated due to physical barriers on the site, (existing building and property fence line) with an anaerobic oil digester. Brent Brown Chevrolet – Provo, Utah As part of a property transaction, Terracon conducted a subsurface investigation in the service area of the Brent Brown Chevrolet and discovered that several underground hydraulic hoists had leaked and impacted the soil and groundwater of the site. Terracon directed the removal of the leaking hoists and excavated an area approximately 90’x 25’x8’ and removed the impacted soils for off-site disposal. Once the excavation was complete, approximately 2,000 gallons of free product (hydraulic oil) was removed from the groundwater surface within the excavation with a vacuum truck. Ten injection wells were installed within the impacted area for injections of BioRem 2000® oil digester. Twelve injection events Geotechnical Ŷ Environmental Ŷ Construction Materials Ŷ Facilities BOWERS, BENJAMIN B. 4 were conducted over a one-year time-frame. Following the injection events, groundwater levels were reported below regulatory cleanup levels and a no further action letter was issued by the Utah Department of Water Quality. Site Investigation The Scoular Company – Utah As part of a property transaction, conducted an extensive subsurface investigation, including the delineation of a trichloroethylene (TCE) groundwater plume that migrated off the grain-handling facility site impacting an adjoining industrial park. The TCE plume is currently listed on the CERCLIS database as the “Ogden Industrial Park Plume.” Mr. Bowers is currently providing the client litigation support and document review for additional site remediation efforts conducted by the previous owner’s consultant. The Scoular Company – Southeastern Idaho Terracon conducted subsurface investigations on four grain-handling facilities in southeastern Idaho. Phase I ESAs previously conducted on the sites indicated the potential of soil and groundwater contamination from carbon tetrachloride that was used at one of the sites and potentially used at the others. Analytical results from the subsurface investigation were compared to the proper State of Utah, Federal and Idaho DEQ Risk Screening Process. Associated Foods Stores – Salt Lake City, Utah Project Manager for remediation efforts of a soil, groundwater, and free-phase product cleanup. The site was previously used as a fleet truck repair and refueling center. Site remediation activities included a pump and treat system, air sparging, free product recovery, and extensive soil excavations. Richmond American Homes – South Jordan, Utah Completed numerous limited site investigations to evaluate the presence of lead and arsenic in the on- site soils/fills for more than 250 residential lots within the Kennecott Land Daybreak development. Terracon conducted X-ray fluorescence (XRF) screening measurements on soil/fill samples to identify target samples for laboratory testing. All Resort Coach, Inc. DBA Lewis Stages – Salt Lake City, Utah Terracon conducted a Phase I ESA and limited site investigation as part of a property transaction. The limited site investigation revealed the presence of soil and groundwater contamination from existing underground storage tanks (USTs) above regulatory limits. Terracon directed efforts for the removal of three USTs, the contaminated soil removal and the repair of existing USTs to meet State of Utah standards and achieve regulatory closure. APPENDIX F DESCRIPTION OF TERMS AND ACRONYMS Description of Selected General Terms and Acronyms Term/Acronym Description ACM Asbestos Containing Material. Asbestos is a naturally occurring mineral, three varieties of which (chrysotile, amosite, crocidolite) have been commonly used as fireproofing or binding agents in construction materials. Exposure to asbestos, as well as ACM, has been documented to cause lung diseases including asbestosis (scarring of the lung), lung cancer and mesothelioma (a cancer of the lung lining). Regulatory agencies have generally defined ACM as a material containing greater that one (1) percent asbestos, however some states (e.g. California) define ACM as materials having 0.1% asbestos. In order to define a homogenous material as non-ACM, a minimum number of samples must be collected from the material dependent upon its type and quantity. Homogenous materials defined as non-ACM must either have 1) no asbestos identified in all of its samples or 2) an identified asbestos concentration below the appropriate regulatory threshold. Asbestos concentrations are generally determined using polarized light microscopy or transmission electron microscopy. Point counting is an analytical method to statistically quantify the percentage of asbestos in a sample. The asbestos component of ACM may either be friable or non-friable. Friable materials, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure and have a higher potential for a fiber release than non-friable ACM. Non-friable ACM are materials that are firmly bound in a matrix by plastic, cement, etc. and, if handled carefully, will not become friable. Federal and state regulations require that either all suspect building materials be presumed ACM or that an asbestos survey be performed prior to renovation, dismantling, demolition, or other activities that may disturb potential ACM. Notifications are required prior to demolition and/or renovation activities that may impact the condition of ACM in a building. ACM removal may be required if the ACM is likely to be disturbed or damaged during the demolition or renovation. Abatement of friable or potentially friable ACM must be performed by a licensed abatement contractor in accordance with state rules and NESHAP. Additionally, OSHA regulations for work classification, worker training and worker protection will apply. AHERA Asbestos Hazard Emergency Response Act AST Aboveground Storage Tanks. ASTs are generally described as storage tanks less than 10% of which are below ground (i.e., buried). Tanks located in a basement, but not buried, are also considered ASTs. Whether, and the extent to which, an AST is regulated, is determined on a case-by-case basis and depends upon tank size, its contents and the jurisdiction of its location. BGS Below Ground Surface Brownfields State and/or tribal listing of Brownfield properties addressed by Cooperative Agreement Recipients or Targeted Brownfields Assessments. BTEX Benzene, Toluene, Ethylbenzene, and Xylenes. BTEX are VOC components found in gasoline and commonly used as analytical indicators of a petroleum hydrocarbon release. CERCLA Comprehensive Environmental Response, Compensation and Liability Act (a.k.a. Superfund). CERCLA is the federal act that regulates abandoned or uncontrolled hazardous waste sites. Under this Act, joint and several liability may be imposed on potentially responsible parties for cleanup-related costs. CERCLIS Comprehensive Environmental Response, Compensation and Liability Information System. An EPA compilation of sites having suspected or actual releases of hazardous substances to the environment. CERCLIS also contains information on site inspections, preliminary assessments and remediation of hazardous waste sites. These sites are typically reported to EPA by states and municipalities or by third parties pursuant to CERCLA Section 103. CESQG Conditionally Exempt Small Quantity Generators CFR Code of Federal Regulations Description of Selected General Terms and Acronyms Term/Acronym Description CREC Controlled Recognized Environmental Condition is defined in ASTM E1527-13 as “a recognized environmental condition resulting from a past release of hazardous substances or petroleum products that has been addressed to the satisfaction of the applicable regulatory authority (for example, as evidenced by the issuance of a no further action letter or equivalent, or meeting risk-based criteria established by regulatory authority) , with hazardous substances or petroleum products allowed to remain in place subject to the implementation of required controls (for example, property use restrictions, activity and use limitations, institutional controls, or engineering controls). A condition considered by the environmental professional to be a controlled recognized environmental condition shall be listed in the findings section of the Phase I Environmental Site Assessment report, and as a recognized environmental condition in the conclusions section of the Phase I Environmental Site Assessment report.” DOT U.S. Department of Transportation EPA U.S. Environmental Protection Agency ERNS Emergency Response Notification System. An EPA-maintained federal database which stores information on notifications of oil discharges and hazardous substance releases in quantities greater than the applicable reportable quantity under CERCLA. ERNS is a cooperative data- sharing effort between EPA, DOT, and the National Response Center. ESA Environmental Site Assessment FRP Fiberglass Reinforced Plastic Hazardous Substance As defined under CERCLA, this is (A) any substance designated pursuant to section 1321(b)(2)(A) of Title 33, (B) any element, compound, mixture, solution, or substance designated pursuant to section 9602 of this title; (C) any hazardous waste having characteristics identified under or listed pursuant to section 3001 of the Solid Waste Disposal Act (with some exclusions); (D) any toxic pollutant listed under section 1317(a) of Title 33; (E) any hazardous air pollutant listed under section 112 of the Clean Air Act; and (F) any imminently hazardous chemical substance or mixture with respect to which the EPA Administrator has taken action under section 2606 of Title 15. This term does not include petroleum, including crude oil or any fraction thereof which is not otherwise listed as a hazardous substance under subparagraphs (A) through (F) above, and the term include natural gas, or synthetic gas usable for fuel (or mixtures of natural gas and such synthetic gas). Hazardous Waste This is defined as having characteristics identified or listed under section 3001 of the Solid Waste Disposal Act (with some exceptions). RCRA, as amended by the Solid Waste Disposal Act of 1980, defines this term as a “solid waste, or combination of solid wastes, which because of its quantity, concentration, or physical, chemical, or infectious characteristics may (A) cause, or significantly contribute to an increase in mortality or an increase in serious irreversible, or incapacitating reversible illness; or (B) pose a substantial present or potential hazard to human health or the environment when improperly treated, stored, transported, or disposed of, or otherwise managed.” HREC Historical Recognized Environmental Condition is defined in ASTM E1527-13 as “a past release of any hazardous substances or petroleum products that has occurred in connection with the property and has been addressed to the satisfaction of the applicable regulatory authority or meeting unrestricted residential use criteria established by a regulatory authority, without subjecting the property to any required controls (for example, property use restrictions, activity and use limitations, institutional controls, or engineering controls). Before calling the past release a historical recognized environmental condition, the environmental professional must determine whether the past release is a recognized environmental condition at the time of the Phase I Environmental Site Assessment is conducted (for example, if there has been a change in the regulatory criteria). If the EP considers the past release to be a recognized environmental condition at the time the Phase I ESA is conducted, the condition shall be included in the conclusions section of the report as a recognized environmental condition.” IC/EC A listing of sites with institutional and/or engineering controls in place. IC include administrative measures, such as groundwater use restrictions, construction restrictions, property use restrictions, and post remediation care requirements intended to prevent exposure to contaminants remaining on site. Deed restrictions are generally required as part of the institutional controls. EC include various forms of caps, building foundations, liners, and treatment methods to create pathway elimination for regulated substances to enter environmental media or effect human health. ILP Innocent Landowner/Operator Program LQG Large Quantity Generators LUST Leaking Underground Storage Tank. This is a federal term set forth under RCRA for leaking USTs. Some states also utilize this term. Description of Selected General Terms and Acronyms Term/Acronym Description MCL Maximum Contaminant Level. This Safe Drinking Water concept (and also used by many states as a ground water cleanup criteria) refers to the limit on drinking water contamination that determines whether a supplier can deliver water from a specific source without treatment. MSDS Material Safety Data Sheets. Written/printed forms prepared by chemical manufacturers, importers and employers which identify the physical and chemical traits of hazardous chemicals under OSHA’s Hazard Communication Standard. NESHAP National Emissions Standard for Hazardous Air Pollutants (Federal Clean Air Act). This part of the Clean Air Act regulates emissions of hazardous air pollutants. NFRAP Facilities where there is “No Further Remedial Action Planned,” as more particularly described under the Records Review section of this report. NOV Notice of Violation. A notice of violation or similar citation issued to an entity, company or individual by a state or federal regulatory body indicating a violation of applicable rule or regulations has been identified. NPDES National Pollutant Discharge Elimination System (Clean Water Act). The federal permit system for discharges of polluted water. NPL The NPL is the EPA’s database of uncontrolled or abandoned hazardous waste facilities that have been listed for priority remedial actions under the Superfund Program. OSHA Occupational Safety and Health Administration or Occupational Safety and Health Act PACM Presumed Asbestos-Containing Material. A material that is suspected of containing or presumed to contain asbestos but which has not been analyzed to confirm the presence or absence of asbestos. PCB Polychlorinated Biphenyl. A halogenated organic compound commonly in the form of a viscous liquid or resin, a flowing yellow oil, or a waxy solid. This compound was historically used as dielectric fluid in electrical equipment (such as electrical transformers and capacitors, electrical ballasts, hydraulic and heat transfer fluids), and for numerous heat and fire sensitive applications. PCB was preferred due to its durability, stability (even at high temperatures), good chemical resistance, low volatility, flammability, and conductivity. PCBs, however, do not break down in the environment and are classified by the EPA as a suspected carcinogen. 1978 regulations, under the Toxic Substances Control Act, prohibit manufacturing of PCB-containing equipment; however, some of this equipment may still be in use today. pCi/L picoCuries per Liter of Air. Unit of measurement for Radon and similar radioactive materials. PLM Polarized Light Microscopy (see ACM section of the report, if included in the scope of services) PST Petroleum Storage Tank. An AST or UST that contains a petroleum product. Radon A radioactive gas resulting from radioactive decay of naturally-occurring radioactive materials in rocks and soils containing uranium, granite, shale, phosphate, and pitchblende. Radon concentrations are measured in picoCuries per Liter of Air. Exposure to elevated levels of radon creates a risk of lung cancer; this risk generally increases as the level of radon and the duration of exposure increases. Outdoors, radon is diluted to such low concentrations that it usually does not present a health concern. However, radon can accumulate in building basements or similar enclosed spaces to levels that can pose a risk to human health. Indoor radon concentrations depend primarily upon the building's construction, design and the concentration of radon in the underlying soil and ground water. The EPA recommended annual average indoor “action level” concentration for residential structures is 4.0 pCi/l. RCRA Resource Conservation and Recovery Act. Federal act regulating solid and hazardous wastes from point of generation to time of disposal (‘cradle to grave”). 42 U.S.C. 6901 et seq. RCRA Generators The RCRA Generators database, maintained by the EPA, lists facilities that generate hazardous waste as part of their normal business practices. Generators are listed as either large (LQG), small (SQG), or conditionally exempt (CESQG). LQG produce at least 1000 kg/month of non-acutely hazardous waste or 1 kg/month of acutely hazardous waste. SQG produce 100-1000 kg/month of non-acutely hazardous waste. CESQG are those that generate less than 100 kg/month of non-acutely hazardous waste. RCRA CORRACTS/TS Ds The USEPA maintains a database of RCRA facilities associated with treatment, storage, and disposal (TSD) of hazardous materials which are undergoing “corrective action”. A “corrective action” order is issued when there is a release of hazardous waste or constituents into the environment from a RCRA facility. RCRA Non- CORRACTS/TS Ds The RCRA Non-CORRACTS/TSD Database is a compilation by the USEPA of facilities which report storage, transportation, treatment, or disposal of hazardous waste. Unlike the RCRA CORRACTS/TSD database, the RCRA Non-CORRACTS/TSD database does not include RCRA facilities where corrective action is required. Description of Selected General Terms and Acronyms Term/Acronym Description RCRA Violators List RAATS. RCRA Administrative Actions Taken. RAATS information is now contained in the RCRIS database and includes records of administrative enforcement actions against facilities for noncompliance. RCRIS Resource Conservation and Recovery Information System, as defined in the Records Review section of this report. REC Recognized Environmental Conditions are defined by ASTM E1527-13 as “the presence or likely presence of any hazardous substances or petroleum products in, on, or at a property: 1) due to any release to the environment; 2) under conditions indicative of a release to the environment.De minimis conditions are not recognized environmental conditions.” SCL State “CERCLIS” List (see SPL /State Priority List, below). SPCC Spill Prevention, Control and Countermeasures. SPCC plans are required under federal law (Clean Water Act and Oil Pollution Act) for any facility storing petroleum in tanks and/or containers of 55-gallons or more that when taken in aggregate exceed 1,320 gallons. SPCC plans are also required for facilities with underground petroleum storage tanks with capacities of over 42,000 gallons. Many states have similar spill prevention programs, which may have additional requirements. SPL State Priority List. State list of confirmed sites having contamination in which the state is actively involved in clean up activities or is actively pursuing potentially responsible parties for clean up. Sometimes referred to as a State “CERCLIS” List. SQG Small Quantity Generator SWF/LF State and/or Tribal database of Solid Waste/Landfill facilities. The database information may include the facility name, class, operation type, area, estimated operational life, and owner. TPH Total Petroleum Hydrocarbons TRI Toxic Release Inventory. Routine EPA report on releases of toxic chemicals to the environment based upon information submitted by entities subject to reporting under the Emergency Planning and Community Right to Know Act. TSCA Toxic Substances Control Act. A federal law regulating manufacture, import, processing and distribution of chemical substances not specifically regulated by other federal laws (such as asbestos, PCBs, lead-based paint and radon). 15 U.S.C 2601 et seq. USACE United States Army Corps of Engineers USC United States Code USGS United States Geological Survey USNRCS United States Department of Agriculture-Natural Resource Conservation Service UST Underground Storage Tank. Most federal and state regulations, as well as ASTM E1527-13, define this as any tank, incl., underground piping connected to the tank, that is or has been used to contain hazardous substances or petroleum products and the volume of which is 10% or more beneath the surface of the ground (i.e., buried). VCP State and/or Tribal facilities included as Voluntary Cleanup Program sites. VOC Volatile Organic Compound Description of Selected General Terms and Acronyms Term/Acronym Description Wetlands Areas that are typically saturated with surface or ground water that creates an environment supportive of wetland vegetation (i.e., swamps, marshes, bogs). The Corps of Engineers Wetlands Delineation Manual (Technical Report Y-87-1) defines wetlands as areas inundated or saturated by surface or ground water at a frequency and duration sufficient to support, and that under normal circumstances do support, a prevalence of vegetation typically adapted for life in saturated soil conditions. For an area to be considered a jurisdictional wetland, it must meet the following criteria: more than 50 percent of the dominant plant species must be categorized as Obligate, Facultative Wetland, or Facultative on lists of plant species that occur in wetlands; the soil must be hydric; and, wetland hydrology must be present. The federal Clean Water Act which regulates “waters of the US,” also regulates wetlands, a program jointly administered by the USACE and the EPA. Waters of the U.S. are defined as: (1) waters used in interstate or foreign commerce, including all waters subject to the ebb and flow of tides; (2) all interstate waters including interstate wetlands; (3) all other waters such as intrastate lakes, rivers, streams (including intermittent streams), mudflats, sandflats, wetlands, sloughs, prairie potholes, wet meadows, playa lakes, or natural ponds, etc., which the use, degradation, or destruction could affect interstate/ foreign commerce; (4) all impoundments of waters otherwise defined as waters of the U. S., (5) tributaries of waters identified in 1 through 4 above; (6) the territorial seas; and (7) wetlands adjacent to waters identified in 1 through 6 above. Only the USACE has the authority to make a final wetlands jurisdictional determination.