HomeMy WebLinkAboutDRC-2025-002313 CLIVE SITE
LETTER OF TRANSMITTAL DATE: 2/18/2025 ATTN: LLRW
CC; Treesa Parker Karen Kirkwood RE: Transmittal 2025-010
Description of Documents Transmitted Qty
See attached for update to Quality Control. CL-QC-PO-001 Rev 15 CML Quality Manual 1 ------------------------------------------------------------------------------------------------------------ Please replace your current procedure revisions with the documents within this Transmittal. You are not required to sign any documents to verify receipt of this distribution. However, you should make every effort to ensure that your copy of the License is current. FROM: EnergySolutions Document Control Clive Facility
CL-QC-PO-001
CML Quality Manual
Revision 15
Authored By:
James Cason, Quality Control Supervisor Date
Reviewed By:
Curtis Kirk, Director, Quality Assurance Date
Approved By
Garrett Q. Dutson, PE, Engineer, Clive Facility Date
Non-Proprietary New
Proprietary Title Change
Restricted Information Revision
Safeguards Information Rewrite
Sensitive Security Information Cancellation
James Cason Digitally signed by James Cason
Date: 2025.02.14 12:22:39 -07'00'
Digitally signed by Curtis Kirk
DN: C=US, OU=EnergySolutions, O=Quality Assurance, CN=Curtis Kirk,
E=ckirk@energysolutions.com
Reason: I am the author of this documentLocation: your signing location here
Date: 2025-02-17 07:18:30Foxit PhantomPDF Version: 9.7.5
Curtis Kirk
Garrett Q. Dutson, P.E.Digitally signed by Garrett Q. Dutson, P.E.
Date: 2025.02.17 10:32:57 -07'00'
CL-QC-PO-001
CML Quality Manual Revision 15
Page 2 of 14
Table of Contents
CML Quality Manual ...................................................................................................................... 1
1 ORGANIZATION AND ORGANIZATIONAL POLICIES ................................................. 3
1.1 Legal Name and Address of the Construction Material Laboratory (CML) .......... 3
1.2 STAFF ............................................................................................................................ 5
1.3 EQUIPMENT ................................................................................................................ 6
1.4 TEST RECORDS AND REPORTS ............................................................................ 9
1.5 PROCEDURES FOR SAMPLE MANAGEMENT ................................................. 10
1.6 DIAGNOSTIC AND CORRECTIVE ACTION ...................................................... 11
1.7 INTERNAL QUALITY SYSTEM REVIEW ........................................................... 11
1.8 SUBCONTRACTING ................................................................................................ 11
2 TECHNICAL MANAGER ................................................................................................... 11
2.1 EnergySolutions’ Technical Manager ....................................................................... 11
3 QUALITY SYSTEM MANAGEMENT .............................................................................. 12
3.1 Top Management Review ........................................................................................... 12
3.2 Quality System Staff ................................................................................................... 12
4 QUALIFICATIONS, ACCREDITATIONS AND RECOGNITION OF AGENCY BY
OTHERS ....................................................................................................................................... 12
5 LIST OF APPENDICES ....................................................................................................... 13
CL-QC-PO-001
CML Quality Manual Revision 15
Page 3 of 14
1 ORGANIZATION AND ORGANIZATIONAL POLICIES
1.1 Legal Name and Address of the Construction Material Laboratory (CML)
EnergySolutions, LLC.
Corporate Address Clive/Lab Address
299 South Main Street, #1700 2235 S Saltbush
SLC, Utah 84111 Clive/Grantsville, UT 84029
1.1.1 Ownership and Management Structure
EnergySolutions, LLC is a Utah limited liability company wholly-owned
by EnergySolutions, Inc.
The management structure for the CML has been provided in Attachment
5.1 of Appendix A to this document.
Figure 1 provides a list showing ownership and affiliations of the Principal
Officers and Directors.
Figure 1. Ownership and Affiliation of the Principal Officers and
Directors
CL-QC-PO-001
CML Quality Manual Revision 15
Page 4 of 14
1.1.2 Organizational Chart of Relevant Internal Organizational Components
EnergySolutions is organized in accordance with Appendix R.
The relevant internal organizational components of EnergySolutions’
CML consist of the following:
• The President, CEO;
• President, Operational Waste Management.
• Vice President, Fixed Facilities
• General Manager, Clive Facility.
• Engineer, Clive Facility (Designated Soils Lab Manager);
• Quality Control Supervisor (Technical Manager pro tem);
• Quality Control Technicians.
An organizational chart of how these different internal components
interact has been provided in Appendix G. As indicated above,
EnergySolutions’ Engineer, Clive Facility will act as the CML’s
Designated Soils Lab Manager. He will also be responsible for ensuring
that tests proceed in accordance with current ASTM procedures as per
Section 3.2.1 of Appendix A. Should the Soil Lab Manager be away from
the CML, EnergySolutions’ Quality Control Supervisor will act as the Soil
Lab Manager’s designee.
1.1.3 Quality System Policy Statement
EnergySolutions’ Quality System Policy Statement is provided as
Appendix I. Copies of the Quality Assurance Policy can also be found on
EnergySolutions’ Intraweb, which is readily accessible in the CML.
1.1.4 Records
All records shall be maintained in accordance with Appendix L. As
mentioned in Appendix A section 3.2.6, records shall be maintained for
the life of the facility. Employee training records will be kept on file for
the duration of the individual’s employment and calibration and
certification records for a piece of equipment will be maintained for a
minimum of five (5) years.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 5 of 14
1.2 STAFF
1.2.1 Outline of Operational Personnel Positions and Their Lines of Authority
and Responsibility
Various Departments and individuals share responsibilities to ensure that
EnergySolutions’ CML functions properly and within AASHTO
certification standards and guidelines. Please refer to Section 3.2 of
Appendix A for departmental and individual responsibilities of the internal
components that will ensure the proper functioning of the CML. Also,
Section 4.1 of Appendix A illustrates the reporting structures and lines of
authority that have been established to ensure the CML operates
effectively. As discussed in Section 1.2.3, individuals working in the CML
will be required to undergo training in accordance within the confines of
an established training program.
Position descriptions for each technical operational position are located in
the custody of the Quality Control Supervisor.
1.2.2 Biographical Sketch of Supervisory Technical Staff
Biographical sketches of the supervisory technical staff (the Engineer,
Clive Facility, and Quality Control Supervisor) are located in Appendix U.
1.2.3 Training Document
All EnergySolutions personnel participating in the operations of the CML
shall be trained in accordance with EnergySolutions’ internal training and
qualifications procedures as specified in Section 4.1.2 of Appendix A to
this document. Further, CML operating staff shall be qualified and
educated to the extents listed in the most current revision of ASTM-
D3740, Minimum Requirements for Agencies in the Testing and/or
Inspection of Soil and Rock as Used in Engineering Design Construction,
as referenced in Section 4.1.1 of Appendix A.
This training shall be documented and kept in accordance with
EnergySolutions’ training program (please refer to Section 4.1.2 of
Appendix A).
CL-QC-PO-001
CML Quality Manual Revision 15
Page 6 of 14
1.2.4 Methods Used to Evaluate Staff Competency
The Quality Control Supervisor and Quality Control Technician II(s) will
be required to re-qualify for their specific testing and laboratory functions
every three years. The Quality Control Technician(s) will be required to
re-qualify for their specific testing and laboratory functions every two
years. Collectively these positions may be referred to as Quality Control
personnel below. Periodically, the Lab Manager or his qualified designee
will review the work performed by the Quality Control personnel. The Lab
Manager and his qualified designee have the authority to require Quality
Control personnel to re-qualify more often than the cited ASTM frequency
if it is deemed necessary. Original qualification documentation shall be
transmitted to Document Control and a copy shall also be kept in the Q.C.
Department files.
1.2.5 Training and Competency Evaluation Forms
EnergySolutions requires CML personnel to undergo and complete
qualification modules prior to performing unsupervised soil tests or
analyses. These qualification modules include the name of the trainee, the
name of the Subject Matter Expert (SME), or trainer, the test method
evaluated, the dates qualification requirements are completed, and the
final results of the qualification process.
Training and Competency Evaluation forms (i.e. qualification modules)
shall be documented and kept in accordance with EnergySolutions’
training program (please refer to Section 4.1.2 of Appendix A).
An example qualification module for one of the test methods utilized at
the CML is provided as Appendix B to this manual.
1.3 EQUIPMENT
The CML will use various pieces of equipment to perform soils tests in
accordance with the ASTM procedures listed in Section 4.2 of Appendix A.
Under no circumstances will the CML use equipment that does not conform to the
requirements set forth in Section 1.3 of this document.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 7 of 14
1.3.1 Inventory
A list of the equipment used in the CML has been provided as Appendix C
to this document. An updated list of equipment shall be located in the
CML at all times.
1.3.2 Equipment Calibration and Check
1.3.2.1 List and description of equipment used to perform various
testing
Appendix C also illustrates calibration due dates and
methods by which equipment calibrations shall be
performed for each piece of equipment used for testing
purposes within the CML. An updated list of calibration
dates and check standards for all equipment used in the
CML shall be located in the CML at all times.
Calibration and check records shall be maintained in
accordance with Appendix K.
1.3.2.2 Document for ensuring that all calibration and check
procedures are performed correctly and at the appropriate
intervals
EnergySolutions’ CML adheres to Appendix J, a procedure
that is designed to establish a consistent method for the
selection, receipt, acceptance, and overall control of
Measuring and Test Equipment used for activities affecting
quality and compliance.
Further, the CML will calibrate lab equipment in accordance
with Appendix K, a procedure that defines the method for
calibrating Quality Control Engineering lab (CML) and field
measuring and test equipment used at EnergySolutions’
Clive facility.
1.3.2.3 In-house equipment check and calibration procedures, or
reference to their location in the CML
Equipment check and calibration procedures shall be
performed and documented in accordance with Appendix K,
which includes the required documentation information
listed below:
CL-QC-PO-001
CML Quality Manual Revision 15
Page 8 of 14
• Detailed results of the work performed;
• Description of the equipment calibrated or checked
including model or serial number or other
acceptable I.D. number;
• Date the work was performed;
• Identification of the individual performing the
work;
• Identification of the calibration or check procedure
used;
• The previous calibration or check date and the next
due date; and,
• Identification of any in-house calibration or check
device used (including serial number, lab number or
other identification used to establish traceability of
items such as standard masses, proving rings,
standard thermometers, balances, calipers, etc.).
1.3.2.4 Traceability of in-house equipment or reference standards,
or reference to their location in the CML
EnergySolutions’ CML will adhere to Appendix K, which
requires that Materials and test equipment be calibrated with
NIST traceable instrumentation.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 9 of 14
1.3.3 Equipment Maintenance
Preventative maintenance will be performed on all equipment identified in
Appendix S. Equipment maintenance shall be performed in accordance
with the applicable manufacturer’s specifications.
EnergySolutions’ Maintenance Department shall perform equipment
maintenance/repairs when a “Work Order” is generated by the electronic
maintenance program “MP2”. An example work order can be found in
Appendix T.
1.4 TEST RECORDS AND REPORTS
1.4.1 Document Detailing Methods Used to Produce Test Records and to
Prepare, Amend and Check Test Reports
EnergySolutions’ CML adheres to Appendix L, a procedure designed to
define the methods for identification, collection, retrievability, protection
and control of quality records generated by EnergySolutions’ Clive
facility.
1.4.2 Test Report Requirements
Test reports generated by EnergySolutions’ CML will contain the
following information:
• Name and address of the testing facility;
• Identification of the report and the date issued;
• Name and address of the client or identification of the project;
• Description, identification and condition of the test sample;
• Date of receipt of the test sample;
• Date(s) of test performance;
• Identification of the standard test method used and a notation of all
known deviations from the test method;
• Test results and other pertinent data required by the standard test
method;
• Identification of any test results obtained from tests performed by a
subcontractor; and,
• Name(s) of the person(s) accepting technical responsibility for the
test report.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 10 of 14
Note, that the address of the testing facility will not be required for reports
intended for internal use only.
Please see Section 4.1.4 of Appendix A.
Test reports will also retain enough information to be able to verify any
report produced.
Typical test records are located in Appendix H.
1.4.3 Preparing and Checking Test Reports
EnergySolutions’ CML will adhere to Sections 4.1.4, 4.1.5 & 4.1.6 of
Appendix A, for preparing and checking of test reports.
Resulting records shall be kept in accordance with Appendix A.
1.4.4 Amending Reports
When a Report shall be Amended:
• The report shall be corrected by using a single line through the
error; add the corrected result(s); then initial and date the line out
and amended result(s). The corrected report shall be processed, re-
reviewed and filed in the normal manner.
-OR-
• A new report form shall be filled out indicating the amended test
results; amended test form shall be indicated on the form; the
comment section on the report form shall state the reason for the
amended report; the amended report shall be attached to the
original report. The amended report shall be processed in the
normal manner and filed with the original report.
1.5 PROCEDURES FOR SAMPLE MANAGEMENT
Samples will be managed in accordance with the recommendations set forth in the
respective ASTM procedures referenced in Section 4.2 of Appendix A. The most
current revision of ASTM C-702, Standard Practice for Reducing Field Samples
of Aggregate to Testing Size referenced in Section 4.2.5 of Appendix A will be
adhered to when procuring a test sample for analysis. A technical Memo has been
provided as Appendix D that details the methods by which samples shall be
identified, stored, retained and disposed.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 11 of 14
1.6 DIAGNOSTIC AND CORRECTIVE ACTION
1.6.1 Document Describing Participation in proficiency Sampling and On-Site
Assessment Programs.
Appendix E discusses EnergySolutions’ participation in proficiency
sampling and on-site assessment programs. It is the responsibility of the
Quality Control Supervisor to review all proficiency sampling results, on-
site inspection and quality evaluations and report poor results to the
appropriate unit supervisor. Appendix E also delineates the steps to be
taken when deficiencies in sample testing and on-site inspections occur.
1.6.2 Method Used for Responding to External Technical Complaints.
EnergySolutions will respond to external complaints in accordance with
Appendix M, which is implemented in order to provide a consistent
method for determining the root cause of deficiencies in systems at
EnergySolutions’ Clive facility. Appendix N will also be implemented in
order to establish a consistent method for prompt identification,
documentation, notification, tracking, analysis, resolutions, follow up, and
status of regulatory or programmatic deficiencies and overall process
improvements.
1.7 INTERNAL QUALITY SYSTEM REVIEW
Appendix F describes EnergySolutions’ scope for internal quality system reviews,
frequency, individuals responsible, distribution to management and location of the
resulting records.
1.8 SUBCONTRACTING
EnergySolutions’ CML shall control the procurement of items and subcontracting
services in accordance with Appendix O and Appendix P, internal procedures
used to assure that specific safety, quality and compliance requirements are met.
2 TECHNICAL MANAGER
The CML shall have a Soils Lab Manager who has overall responsibility for the technical
operations of the laboratory. In addition, the CML shall nominate an individual to serve
in the Technical Manager’s absence.
2.1 EnergySolutions’ Technical Manager
As listed in Section 1.1.2 above, EnergySolutions’ Engineer, Clive Facility shall
act as the Soils Lab Manager for the CML. In his absence, the Quality Control
Supervisor shall act in his stead.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 12 of 14
3 QUALITY SYSTEM MANAGEMENT
3.1 Top Management Review
The laboratory’s top management shall review the quality system at least
annually, and whenever a technical complaint cast doubt on the quality of the
CML’s work, to ensure the quality system’s continuing suitability and
effectiveness, and introduce any necessary changes or improvements. At a
minimum, management review shall include the following:
• Results of internal and external audits.
• Proficiency Sample performance.
• Status of corrective actions.
• Personnel staffing changes and training needs.
• Updates to QMS policies and procedures, and
• Customer Complaints.
Any changes to this Quality Manual will require the review and signature of the
Engineer, Clive Facility, the Quality Control Supervisor, and the Director, Quality
Assurance.
3.2 Quality System Staff
3.2.1 The Quality Control Supervisor has the responsibility for determining if
the quality system implementation activities are being conducted by the
CML staff in a manner specified in the CML’s Quality Manual.
3.2.2 Section 3.2.5 of Appendix A, discusses the responsibilities of Quality
Assurance to ensure the quality of work performed by the CML.
4 QUALIFICATIONS, ACCREDITATIONS AND RECOGNITION OF AGENCY
BY OTHERS
A list showing applicable dates of qualifications, accreditations and recognition of agency
by others is provided as Appendix Q, of this manual.
CL-QC-PO-001
CML Quality Manual Revision 15
Page 13 of 14
5 LIST OF APPENDICES
Appendix A: CL-QC-PR-025, Standard Practice for Achieving Certified AASHTO
Results
Appendix B: Q1123 Sample Qualification Form and Test
Appendix C: Equipment Inventory and Measuring and Testing Equipment Tracking
Sheet
Appendix D: Sample Processing
Appendix E: Procedures Related to Proficiency Sample Testing and On-Site Inspections
Appendix F: Quality System Review Procedures & Internal Quality System Review
Check Sheet
Appendix G: CML’s Organization Chart
Appendix H: Example Test Reports
Appendix I: Quality System Policy Statement
Appendix J: ES-AD-PR-009, Control of Measuring and Test Equipment &
CL-QA-WI-120, Control of Measuring and Test Equipment
Appendix K: CL-QC-PR-001, Quality Control Inspections and Testing & CL-QC-PR-
011, M&TE Calibration
Appendix L: CL-QA-PR-005, Records
Appendix M: ES-AD-PR-012, Cause Analysis
Appendix N: ES-AD-PR-008, Condition Reports
Appendix O: ES-QA-PR-003, Supplier Evaluation
Appendix P: ES-QA-PR-009, Quality Levels (Q-List)
Appendix Q: Accreditation Dates
Appendix R: Organization
Appendix S: Routine Preventative Maintenance
Appendix T: Work Order (Example)
Appendix U: Biographical Sketch and Resume
Appendix V: Clive Training Procedure
CL-QC-PO-001
CML Quality Manual Revision 15
Page 14 of 14