Loading...
HomeMy WebLinkAboutDDW-2025-007334Sanitary Survey - Deficiency Report PWS Number:UTAH14056 Deficiency Points:60 Survey Date:08/04/2025 Survey Name:FOOL CREEK CULINARY WATER COMPANY Surveyor:Joshua Owens Sanitary Survey Category: SM SDWIS Severity Code: Recommendation Management and Operations | DS001 | UTAH14056 DISTRIBUTION SYSTEM 31. Does your water system have an Emergency Response Plan? Rule: R309-105-18 All suppliers are advised to develop contingency plans to cope with possible emergency situations. In many areas of the state the possibility of earthquake damage shall be realistically considered. Notes:No plan provided at inspection. Deficiency Points: 0 Days until points become effective on IPS: 0 SDWIS Deficiency Description: M001 NO CURRENT EMERGENCY RESPONSE PROGRAM Sanitary Survey Category: SO SDWIS Severity Code: Minor Deficiency Springs | WS003 | BLACK WILLOW SPRING 91. Spring box has a means to release overflow? Rule: R309-515-7(7)(d), R309-545-13(1)All junction boxes and collection boxes, must comply with R309-545 with respect to access openings, venting, and tank overflow. Lids for these spring boxes shall be gasketed and the box adequately vented. Notes:Inactive Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: SS23 SPRING BOX LACKS A MEANS OF PROVIDING OVERFLOW Sanitary Survey Category: SO SDWIS Severity Code: Minor Deficiency Springs | WS003 | BLACK WILLOW SPRING 98. Is a spring box vent present? ... if yes, answer the following question(s) Rule: R309-515-7(7)(d), R309-545-15 Rule requires junction boxes and collection boxes to comply with R309-545 with respect to venting. Therefore, a junction or collection box requires a vent to be fitted with #14 mesh or finer non-corrodible screen, be fitted with a protective heavy-gauge screen or covering if 6 inches in diameter or greater, be down-turned and shielded to prevent the entrance of contaminants, be located and sized to avoid blockage during winter, and have the end of the vent discharge a minimum of 24 inches above the earth on buried structures. Notes:Inactive Deficiency Points: 5 Days until points become effective on IPS: 0 SDWIS Deficiency Description: SS11 SPRING BOX LACKS A MEANS OF VENTING Sanitary Survey Category: TR SDWIS Severity Code: Minor Deficiency Gaseous Chlorination | TP001 | FOOL CREEK CHLORINATOR 144A. Leak response/repair plan available Rule: R309-105-7, 8 & 18, R309-100 through 605 Trigger for regulatory followup to address concerns. Notes:Representative of water system was not the water operator and did not know if they had a plan available. I havenât been able to get in contact with the operator. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: TGR9 TRIGGER FOR REGULATORY FOLLOWUP TO ADDRESS CONCERNS Sanitary Survey Category: TR SDWIS Severity Code: Significant Deficiency Gaseous Chlorination | TP001 | FOOL CREEK CHLORINATOR 144C. Immediate access to NIOSH respirator available Rule: R309-520-7(2)(k)(ii)Where 150 pound chlorine cylinders are used, a respirator recommended the National Institute of Occupational Safety and Health must be available. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:No mask. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: TD04 150-POUND CYLINDER FACILITY LACKS IMMEDIATE ACCESS TO NIOSH RESPIRATOR