Loading...
HomeMy WebLinkAboutDDW-2025-007174System Number 23076 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - 729 Number of other connections - - - 24 ERCs of other connections 105.0 Total Equivalent Residential Connections (ERCs)834.0 gpd/ERC Total (gpm)Gallons/ERC Total (gallons)ac-ft/yr/ERC Total (ac-ft/yr) 800 463.3 400 333,600 0.45 375.30 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >182 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >25%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.25 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >1.60 2 Irrigation zone 4 3 4 5 6 gpd/ERC Total (gpm)Gallons/ERC Total (gallons)ac-ft/yr/ERC Total (ac-ft/yr) 1,426 186.8 712 134,319 0.47 88.19 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,500 Maximum fire suppression duration (in hours) for water system or pressure zone 2 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >180,000 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm)Gallons/ERC Total (gallons)ac-ft/yr/ERC Total (ac-ft/yr) 2,226 650.1 1,112 647,919 0.92 463.49 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 650.1 gpm Existing Source Capacity 1,867.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 287.2% MINIMUM CAPACITY REQUIREMENTS FOR WATER SYSTEM Storage (indoor + outdoor + fire)Water Rights (indoor + outdoor) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Water Rights (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) 15% irrigation by private wells, 85% from PWS Source (indoor + outdoor) Storage Source Water Rights Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 2/12/2016) *Enter the green cells only* (Example: water use of 2 factories equals to water use of 55 homes.) MINIMUM REQUIREMENTS FOR INDOOR WATER USE System Name MINIMUM REQUIREMENTS FOR IRRIGATION USE Source Oquirrh Mountain Water Co Storage Yes No Yes No Enter number of non-residential connections, e.g., 2 industrial connections. Convert "Number of other connections" (Cell E9) to ERCs here. [ERCs of other connections = peak day demand of other connections in gal per day / 800 gpd] Enter estimated irrigated acre Enter total irrigated acres of other connections here. Enter fire flow in gpm. Enter duration in hours. Autolink to 4.2 "Total Existing Source Capacity" cell below. Select Irrigated Zone # from the pick list. See "Irrigation Demands & Map" tab on the bottom of the screen. Less than 100% indicates: (1) additional source capacity is needed, and Autolink to 2 "Total Source" cell above. Source deficit indicates that: (1) additional source capacity is needed, and (2) source deficiency should be assessed. DDW-2022-040741 - Oquirrh Mtn Page 1 of 2 8/4/2025 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 647,919 gal Existing Storage Capacity 1,000,000 gal Storage Capacity Deficit None gal Required Fire Storage 180,000 gal Not Applicable Existing % of Total Req'd 154.3% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 0 30 0 0.00 0.0 20 0 10 0 0.00 0.0 5 0 2.5 0 0.00 0.0 N/A 100 N/A 50 0.13 0.0 Number of people per camp site Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 7 3.5 8.8 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)1,867 4.1 Projected ERCs Calculation (optional)WS001 Hole in the Rock 1400 Total Projected ERCs 587 WS002 Big Canyon Well 200 Existing Residential Connections 587 WS003 Conner Well 267 Obligated Future ERCs (enter below) Maximum ERCs (assuming indoor use only)3360.6 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)1,000,000 ST001 Hole in Rock Storage 1,000,000 Semi-Developed Camp w/ flush toilets Oquirrh Mountain Water Co Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Autolink to 4.3 "Total Existing Storage Capcity" cell below. If applicable, enter number of people per camp site here. Storage deficit indicates that: (1) additional storage volume is needed, and (2) storage deficiency should be assessed. Use this number in Cell I8 ("Number of residential connections") on Page 1 to calculate PROJECTED demand & req'ts (including both existing & future connections). Diaphragm or air pressure tanks shall NOT be considered effective storage volume for (1) community systems, or (2) NTNC with significant demand UNLESS an exception has been granted. Autolink to 2 "Total Storage" cell above. If applicable, use this number in cell I8 or cell I9 on Page 1. If NO, answer one of question set 2.01 to 2.05 in ESS.If YES, answer one of question set 2.06 to 2.10 in ESS. Less than 100% indicates: (1) additional storage capacity is needed, and (2) storage deficiency should be assessed. DDW-2022-040741 - Oquirrh Mtn Page 2 of 2 8/4/2025