Loading...
HomeMy WebLinkAboutDERR-2025-005543Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name SAIA LTL FREIGHT Address 11465 JOHNS CREEK PRKWY 400 DULUTH, GA 30097 Contact SAIA LTL FREIGHT Phone Email jhuntley@saia.com TANK LOCATION Name SAIA LTL FREIGHT Address 794 S 6400 W SALT LAKE CITY, UT 84104 A Operator None Phone None B Operator SAME Phone SAME Facility ID: 4002669 Inspection Date: 07/22/2025 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1 Diesel Yes Steel Flex in Sump Oct. 13, 2023 Nov. 1, 2023 Yes Yes Nov. 1, 2023 None 2 - 2 Diesel Yes Steel Flex in Sump Oct. 9, 2023 Nov. 1, 2023 Yes Yes Nov. 1, 2023 None TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 2023 / 20000 / Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Asphalt Coated or Bare Steel- Double-Walled ATG / LTT Test None LLD Test None Pipe Material-Mod Flexible Plastic / Double- Walled Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 1, 2023 / 20000 / Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Asphalt Coated or Bare Steel- Double-Walled ATG / LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / Double-Walled Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Aboveground Catchment / Overfill alarm / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2025-07-22 Page 1 of 3 FACILITY RESPONSES Financial Responsibility Financial responsibility method is ok?Yes The above accurately represents the facility's release detection records Yes TANK RESPONSES Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 2 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 2 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 1 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 2 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes DISPENSER RESPONSES Dispenser 2 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 1 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Jul '24 Aug '24 Sep '24 Oct '24 Nov '24 Dec '24 Jan '25 Feb '25 Mar '25 Apr '25 May '25 Jun '25 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2025-07-22 Page 2 of 3 Prepared by fueloperator.com Inspection Information Inspector:Ottley, Melissa Record Created:July 22, 2025, 12:04 p.m. Inspection Date:July 22, 2025 2025-07-22 Page 3 of 3