Loading...
HomeMy WebLinkAboutDDW-2025-006861DDW-EdenRanch-SystemCapacityCalcs.xlsx Page 1 of 7/28/2025 Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* System Name Eden Ranch Water Company System Number 17036 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -9 Number of other connections - - - 0 ERCs of other connections 0.0 Total Equivalent Residential Connections (ERCs)9.0 MIN. REQUIREMENTS FOR INDOOR WATER USE Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 5.0)400 (3,600) 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >9 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >100% Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.85 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >0.00 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Irrigation zone 2 MIN. REQUIREMENTS FOR IRRIGATION USE Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 3,427 21.4 1,592 14,328 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,500 Maximum fire suppression duration (in hours) for water system or pressure zone 2 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >180,000 (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) 2. Summary of Water System Capacity Requirements MINIMUM REQUIREMENTS FOR WATER SYSTEM Source (indoor + outdoor)Storage (indoor + outdoor + fire) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 4,227 26.4 1,992 197,928 2.1 Does this system have adequate source capacity (per R309-510-7)? This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Required Source Capacity 26.4 gpm Existing Source Capacity 692.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 2619.2% DDW-EdenRanch-SystemCapacityCalcs.xlsx Page 2 of 7/28/2025 2.2 Does this system have adequate storage capacity (per R309-510-8)? This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Total Required Storage 197,928 gal Existing Storage Capacity 321,741 gal Storage Capacity Deficit None gal Required Fire Storage 180,000 gal Is storage deficiency solely due to fire storage?Not Applicable Existing % of Total Req'd 162.6% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) MINIMUM REQUIREMENTS FOR INDOOR USE Source Storage Facility Type GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Modern Recreation Camp 60 0 30 0 0.00 Semi-Developed Camp w/ flush toilets 20 0 10 0 0.00 Semi-Developed Camp w/o flush toilets 5 0 2.5 0 0.00 RV Park N/A 100 N/A 50 0.13 Number of people per camp site 0 Source (GPD/vehicle) Storage (Gal. /vehicle) ERC/1000 vehicles served Vehicles served/day ERCs Roadway Rest Stop w/ flushometer valves 7 3.5 8.8 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Eden Ranch Water Company Total Existing Source Capacity (in gpm) 4.1 Projected ERCs Calculation (optional)WS001 Eden Ranch Well Total Projected ERCs 70 Existing Residential Connections 9 Obligated Future ERCs (enter below)61 Future erc 61 Maximum ERCs (assuming indoor use only) 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons) ST001 Tank (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) DDW-EdenRanch-SystemCapacityCalcs.xlsx Page 3 of 7/28/2025 Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) (Example: water use of 2 factories equals to water use of 55 homes.) Map Zones 1 2 3 4 5 6 This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. DDW-EdenRanch-SystemCapacityCalcs.xlsx Page 4 of 7/28/2025 This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Total # of sites/pads ERCs 0 0.0 0 0.0 0 0.0 0 0.0 4.2 Summary - Existing Sources (enter in green cells below) 692 692 1245.6 4.3 Summary - Existing Storage Tanks (enter below) 321,741 321,741