Loading...
HomeMy WebLinkAboutDERR-2025-005533pei.org 43 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-3 SPILL BUCKET INTEGRITY TESTING HYDROSTATIC TEST METHOD SINGLE AND DOUBLE-WALLED VACUUM TEST METHOD )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVSURFHGXUHLVWRWHVWWKHOHDNLQWHJULW\RIVLQJOHDQGGRXEOHZDOOHGVSLOOEXFNHWV6HH3(,536HFWLRQIRUK\GURVWDWLF WHVWPHWKRG6HFWLRQIRUVLQJOHZDOOHGYDFXXPWHVWPHWKRGDQG6HFWLRQIRUGRXEOHZDOOHGYDFXXPWHVWPHWKRG 7DQN1XPEHU 3URGXFW6WRUHG 6SLOO%XFNHW &DSDFLW\ 0DQXIDFWXUHU &RQVWUXFWLRQ6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 7HVW7\SH +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG 6SLOO%XFNHW7\SH 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU /LTXLGDQGGHEULV UHPRYHGIURP VSLOOEXFNHW" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9LVXDO,QVSHFWLRQ 1RFUDFNVORRVH SDUWVRUVHSDUD WLRQRIWKHEXFNHW IURPWKHILOOSLSH 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 7DQNULVHUFDS LQFOXGHGLQWHVW" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ ,VGUDLQYDOYH LQFOXGHGLQWHVW" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ 6WDUWLQJ/HYHO 7HVW6WDUW7LPH       (QGLQJ/HYHO 7HVW(QG7LPH 7HVW3HULRG /HYHO&KDQJH 3DVVIDLOFULWHULD0XVWSDVVYLVXDOLQVSHFWLRQ+\GURVWDWLF:DWHUOHYHOGURSRIOHVVWKDQLQFK9DFXXPVLQJOHZDOOHGRQO\ 0DLQWDLQDWOHDVWLQFKHVZDWHUFROXPQ9DFXXPGRXEOHZDOOHGPDLQWDLQDWOHDVWLQFKHVZDWHUFROXPQ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 La Pico Food Mart 7198 W. 3500 S. W.V.C., UT 84120 4002177 MN + JJ Food Stores LLC 7198 W. 3500 S. W.V.C., UT 84120 818-849-9069 06/12/2025 1 REG E. 5 Gal. OPW 4 4 4 4 4 4 4 1 REG W. 5 Gal. Franklin 4 4 4 4 4 4 2 PRM 5 Gal. Franklin 4 4 4 4 4 4 3 DSL 5 Gal. OPW 4 4 4 4 4 4 4 4 8" 0 Min. 8" 60 Min. 60 Min. 0 4 Max LaRou UT 0412 pei.org 45 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-5 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·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´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH BALL FLOAT VALVE INSPECTION 7DQNWRSILWWLQJVDUHYDSRU WLJKWDQGOHDNIUHH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWFDJHIUHHRIGHEULV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOLVIUHHRIKROHVDQGFUDFNV DQGPRYHVIUHHO\LQFDJH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9HQWKROHLQSLSHLVRSHQDQG QHDUWRSRIWDQN"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWSLSHLVSURSHU OHQJWKWRUHVWULFWIORZDW FDSDFLW\" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO  8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIDXWRPDWLFVKXWRIIGHYLFHZLOOVKXWRIIIORZDWFDSDFLW\  8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIIORZUHVWULFWLRQGHYLFHZLOOUHVWULFWIORZDWFDSDFLW\ Comments: Precision Testing Technologies Inc.801-886-9224 La Pico Food Mart 4002177 06/12/25 REG E. 1 20,055 120 N.A. 4 REG W. 1 20,055 120 Franklin 4 4 4 4 4 4 4 PRM 2 15,248 120 Franklin 4 4 4 4 4 4 4 DSL 3 5,165 91 Franklin 4 4 4 4 4 4 4 Max LaRou UT 0412 La Pico Food MartLa Pico Food Mart