Loading...
HomeMy WebLinkAboutDAQ-2024-007388Submitted via EPA CEDRI January 24, 2024 Director, U.S. EPA Region 8 1595 Wynkoop Street Mail Code 8ENF – AT Denver, CO 80202-1129 Re: Kinder Morgan Altamont LLC Bluebell Facility, Title V Operating Permit # 1300033003 40 CFR 60 subpart OOOOa Semiannual LDAR Report July 1, 2023 through December 31, 2023 Kinder Morgan Altamont LLC (Kinder Morgan) is submitting the enclosed Semi-annual Report as required by 40 CFR 60 Subpart OOOOa for the Bluebell Facility. The monitoring report covers the semi-annual period from July 1, 2023 through December 31, 2023. If you have any questions or concerns, please contact me by phone at (918) 588-5044 or by email at janel_nelson@kindermorgan.com. Sincerely, Janel Nelson EHS Specialist – Air Permitting/Compliance Sr II Attachments: OOOOa Delay of Repair report for semiannual reporting period OOOOa Semi-Annual Report (July 1, 2023 through December 31, 2023) Bluebell Facility Part 60 Subpart OOOOa – 60.5422a(a) Semiannual Report Template Cc: Joe Randolph Utah Division of Air Quality 195 North 1950 West Salt Lake City, Utah 84116 Electronic Submittal REVIEWED Initials JBR Date 4/15/2024 Comp Status Meets File # 10219 Blue 2 Semiannual Equipment Leak/VOC Monitoring Report pursuant to NSPS OOOOa This report is being submitted to meet the requirements in 40 CFR 60, Subpart OOOOa, Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification, or Reconstruction Commenced after September 18, 2015. This report covers the period from July 1, 2023 through December 31, 2023. Below is the specific information required by §60.5422a(a)-(c). 60.487a(c)(1) Process unit identification  Condensate  Fractionation  Inlet  Refrigeration  Storage  Truck Loading Rack 60.487a(c)(2)(i)-(iv), (vii)-(viii), and 60.5422a(c) Provided in reporting template submitted via CEDRI. 60.487a(c)(2)(xi) Please see attached. There are no active DOR components as of the end of the reporting period (December 31, 2023). All components on DOR during the semiannual period were repaired during a plant shutdown in July 2023. 60.487a(c)(3) A plant shutdown occurred in July 2023. 60.487a(c)(4) Component Type Component Count (period ending 6/30/2023) Component Count (period ending 12/31/2023) Valve 1115 1111 Pump 11 12 Connector 4621 4657 1/29/24, 10:02 AM View Report | CEDRI https://cdxapps.epa.gov/oar-cedri-phase2/_ui/index.html#/reports/2030915/view?back=%2Fhistory&displayStart=0 1/1 Revise & Re-submit Report CEDRI Repor t Details 60.5422a(a) Semiannual Repor t for KINDER MORGAN ALTAMONT LLC - BLUEBELL GAS PLANT Repor t Facility Cer tifier Revisions Documents Download All Name Size (kb)Date Archived 2024-01-24 Bluebell Semiannual LDAR Report_CEDRI Submittal.zip 336.3 2024-01-29 09:54:02 Repor t Submission Information Report Status Submitted Certification Date 2024-01-29 09:53:51 Available in WebFIRE 2024-02-28 (30 Days) CROMERR Activity ID _ebbf00e2-1435-4081-b4e7-136b3720f914 CROMERR Document ID 01eb0a1f-00ca-4b8d-8838-702e1204e5b3 Repor t Type Information Report Name 60.5422a(a) Semiannual Report Citation 60.5422a(a) - Part 60 Subpart OOOOa - Crude Oil and Natural Gas Facilities for which Construction, Modification, or Reconstruction Commenced after 9/18/2015 Report Type Periodic Report Format Spreadsheet (Template v1.00) OMB Control Number 2060-0721 CDX Help Desk Policy Questions? (cedri@epa.gov) About CDX Frequently Asked Questions Terms and Conditions Contact Us EPA Home Privacy and Security Notice Accessibility Facility Record No. * (Field value will automatically generate.) Facility Name * Address of Processing Plant*Address 2 City * County * State Abbreviation*Zip Code * Responsible Agency Facility ID (State Facility Identifier) Beginning Date of Reporting Period * Ending Date of Reporting Period * Please enter any additional information Enter associated file name reference. e.g.: ABC Company e.g.: 123 Main Street e.g.: Suite 100 e.g.: Brooklyn e.g.: Kings County e.g.: NY e.g.: 11221 e.g.: 01/01/2016 e.g.: 06/30/2016 e.g.: filename.pdf 1 Bluebell Gas Plant 5564 North 5000 West Cedarview Duchesne UT 84066 07/01/2023 12/31/2023 2024-01-24 Bluebell Semiannual LDAR Report_CEDRI Submittal.pdf FACILITY INFORMATION ADDITIONAL INFORMATION 40 CFR Part 60 - Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 - 60.5422a(a) Semiannual Report The asterisk (*) next to each field indicates that the corresponding field is required. Facility Record No. * (Select from dropdown list) Month Identification* (Select from dropdown list) Number of pressure relief devices for which leaks were detected * (§60.5422a(c)(1)) Number of pressure relief devices for which leaks were not repaired * (§60.5422a(c)(2)) Number of valves for which leaks were detected * (§60.487a(c)(2)(i)) Number of valves for which leaks were not repaired * (§60.487a(c)(2)(ii)) Number of pumps for which leaks were detected * (§60.487a(c)(2)(iii)) Number of pumps for which leaks were not repaired * (§60.487a(c)(2)(iv)) Number of connectors for which leaks were detected * (§60.487a(c)(2)(vii), §60.5422a(a)) Number of connectors for which leaks were not repaired * (§60.487a(c)(2)(viii), §60.5422a(a)) e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 e.g.: 5 1 July 00400 0 0 0 1 August 00900 0 4 0 1 September 00900 0 5 0 1 October 00700 0 6 0 1 November 0 0 20 0 0 0 2 0 1 December 0 0 14 0 0 0 1 0 40 CFR Part 60 - Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 - 60.5422a(a) Semiannual Report The asterisk (*) next to each field indicates that the corresponding field is required. EQUIPMENT INFORMATION Report Date :1/23/2024 Compliance Repair Delay List Regulation : Begin Date : End Date : Compliance Group : Tag / Drawing Class Stream ID / Stream Inspection Date Placed On Delay Reason Documentation Expected Repair Removed from Delay / / Number of Components Delayed for Compliance Group = 0 Signature of Owner or Operator Responsible for Delay of Repair Decision TI_R800_3.xml Page 1 of 1 Repair Delayed History (R323)Report Date:1/23/2024 Report Parameters Unit:All Process Units Area:All Areas Regulation:EPA60-OOOOa Tag#:All Tags KINDER MORGAN BLUEBELL -All Leaks 7/1/2023 12/31/2023Class:All Component Classes Leak Option:Reporting Period: UNIT:INLET Exp. Repair Date: Insp. Date Date On Delay Date WR Closed Insp. PPM DOR Insp. PPM Date Off Delay:Tag#:Class Location Area:Reason For Delay Approved By 00637.03 CONECT ULTRA FAB BLDG SESD V-110 PRV 2/16/23 37197 2/21/23 37200 Repair is technically infeasible without a process unit shutdown. Repair of this equipment shall occ AUSTIN ATWOOD - MECHANIC 10/2/23 7/13/23 8/2/23 00637.04 CONECT ULTRA FAB BLDG SESD V-110 PRV 2/16/23 12097 2/21/23 12092 Repair is technically infeasible without a process unit shutdown. Repair of this equipment shall occ AUSTIN ATWOOD - MECHANIC 10/2/23 7/13/23 8/2/23 00637.02 CONECT ULTRA FAB BLDG SESD V-110 PRV BTM SVE 3/10/23 25896 3/13/23 25896 Repair is technically infeasible without a process unit shutdown. Repair of this equipment shall occ AUSTIN ATWOOD 10/1/23 7/13/23 8/2/23 This report produced using LeakDAS. Last modified: 4/20/2021 Page 1 of 2 Repair Delayed History (R323)Report Date:1/23/2024 Report Parameters Unit:All Process Units Area:All Areas Regulation:EPA60-OOOOa Tag#:All Tags KINDER MORGAN BLUEBELL -All Leaks 7/1/2023 12/31/2023Class:All Component Classes Leak Option:Reporting Period: UNIT:REFRIGERATION Exp. Repair Date: Insp. Date Date On Delay Date WR Closed Insp. PPM DOR Insp. PPM Date Off Delay:Tag#:Class Location Area:Reason For Delay Approved By 00869.00 VALVE E OF V-463 ON SKID 5 ALONG WALK WAY LCV-463 3/10/23 1098 3/13/23 1098 Repair is technically infeasible without a process unit shutdown. Repair of this equipment shall occ AUSTIN ATWOOD 10/1/23 7/13/23 8/3/23 This report produced using LeakDAS. Last modified: 4/20/2021 Page 2 of 2