Loading...
HomeMy WebLinkAboutDAQ-2024-007380Clean Harbors Aragonite, LLC I 1600 North Aptus Road Aragonite, UT 84029 435.884.8100 www.cleanharbors.com FedEx # 7726 9481 5210 DIVISION OF AIR QUAL,II Jily 10,2023 Mr. Bryce Bird Division of Air Quality (DAQ) Department of Environmental Quality 195 North 1950 West P.O. Box 144880 Salt Lake city, UT 84414-4880 RE: Semi-Annual Startup, Shutdown, and Malfunction Report Clean Harbors Aragonite, LLC Title V Operating Permit 4500048004 Dear Mr. Bird, In accordance with Title V Permit condition II.B.2.k.3(i), Clean Harbors Aragonite, LLC (CHA) is submitting the Semi-Annual Startup, Shutdown, and Malfunction Report for January through June of 2023. This report requires CHA to submit all startups, shutdowns, and malfunctions that occurred in the reporting period and include the number, duration, and a brief description of each occurrence. This information can be seen in Table 1. All occurrences were handled consistent with the facilities Startup, Shutdown, and Malfunction Plan. Table 1: Start-Shutdow nd Malfunctions t,TAH DEPARTMENT OF EI.IVIBONMENTAL QUAUT'{ JUL 12 ..,(- .,.t u Ilr lt a SSMP Reason SSMP Cause Number Duration (hr:min:sec) Kiln Temperature Cutoff AWFCO - (product fuel didn't maintain heat ouick enoush)I 0l : 19:59 Smoke Blinds Infrareds 1 00:03:48 No Fuel (pump or lance failures)J 04:30:36 Afterburner Temperature Cutoff No Fuel (pump failures)2 0l :17:00 Activated Carbon Below Permissive Cutoff Plugged Line 6 08:01:28 I't and 2nd Stage Low pH and 2nd Stage Rundown PH Soda Ash Plussed Line 2 0l:24:01 oH Probes Fail 2 00:38:01 Soda Ash Pump Failed 1 00:19:00 l" and 2no Stage Brine Flow Rate Valve or Pine Failure 2 00:00:04 High Combustion Zone Pressure Cutoff Builduo Fall 8 00:00:23 ID Fan Failure 00:00:53 Power Failure I 00:00:37 Kiln Seal Issue I 00:00:01 "People and Technologt Creating a Better Environment" REVIEWEDInitials: Date: March 27, 2024Compliance Status: OKFile #: 10725 (B2) SSMP Reason SSMP Cause Number Duration (hr:min:sec) Baghouse Pressure Drop/Opacity Cutoff Bashouse Bas Failure 7 00:00:20 Dust in Outlet Duct 8 00:00:49 Leakins Bypass Damper 00:00:02 Pressure Tubins Plugeed 00:00: l7 High Instrument Span - Baghouse Inlet Pressure Baghouse Bag Failure 2 00:00:07 High Instrument Span - Activated Carbon Feed Rate Carbon Build Up Around Platform l0 00:06:40 Power Failure Utilitv Power Loss 4 03:29:32 In accordance with Permit Condition I.K and Utah Administrative Code R307-415-5d, I certiff under penalty of law that this document and all affachments were prepared under my direct supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based upon my inquiry of persons or persons who manage the system, or those persons directly responsible for gathering the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of imprisonment for known violations.'wh William L. Simmons Facility GM III Clean Harbors Aragonite, LLC I1600 North Atpus Road PO Box 1339 Grantsville, Utah 84029 -1339 (o) 435.8a4.8351 (c) 870.310.6029 simmons. william@cleanharbors. com www.cleanharbors.com