Loading...
HomeMy WebLinkAboutDDW-2025-006453System Number 09093 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - 125 Number of other connections - - - 0 ERCs of other connections 0.0 Total Equivalent Residential Connections (ERCs)125.0 gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 69.4 400 50,000 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >0 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >0%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.05 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >0.00 2 Irrigation zone 1 3 4 5 6 gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 163 0.0 89 0 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 0 Maximum fire suppression duration (in hours) for water system or pressure zone 1 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >0 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 963 69.4 489 50,000 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 69.4 gpm Existing Source Capacity 135.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 194.4% MIN. REQUIREMENTS FOR INDOOR WATER USE MINIMUM REQUIREMENTS FOR WATER SYSTEM Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* (Example: water use of 2 factories equals to water use of 55 homes.) Source MIN. REQUIREMENTS FOR IRRIGATION USE System Name Source Beaver Dam Village SSD Storage (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Source (indoor + outdoor) Storage Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Yes No Yes No Enter number of non-residential connections, e.g., 2 industrial connections. Convert "Number of other connections" (Cell E9) to ERCs here. [ERCs of other connections = peak day demand of other connections in gal per day / 800 gpd] Enter estimated irrigated acre per residential lot here. Enter total irrigated acres of other connections here. Enter fire flow in gpm. Enter duration in hours. Autolink to 4.2 "Total Existing Source Capacity" cell below. Select Irrigated Zone # from the pick list. See "Irrigation Demands & Map" tab on the bottom of the screen or WaterLink. Less than 100% indicates: (1) additional source capacity is needed, and (2) source deficiency should be assessed. Autolink to 2 "Total Source" cell above. Source deficit indicates that: (1) additional source capacity is needed, and (2) source deficiency should be assessed. Beaver Dam Village SSD Capacity 2025 Page 1 of 2 7/18/2025 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 50,000 gal Existing Storage Capacity 182,000 gal Storage Capacity Deficit None gal Required Fire Storage 0 gal Not Applicable Existing % of Total Req'd 364.0% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 0 30 0 0.00 0 0.0 20 0 10 0 0.00 0 0.0 5 0 2.5 0 0.00 0 0.0 N/A 100 N/A 50 0.13 0 0.0 Number of people per camp site 0 Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 7 3.5 8.8 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)135 4.1 Projected ERCs Calculation (optional)WS001 Estates Well 45 Total Projected ERCs 0 WS002 Village A Well 20 Existing Residential Connections 0 WS003 Village B Well 40 Obligated Future ERCs (enter below)0 WS004 Village C Well 30 Maximum ERCs (assuming indoor use only)243 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)182,000 ST001 Storage Tank 22K 22,000 ST002 Storage Tank 30K 30,000 St004 Storage Tank 80K 80,000 ST005 Storage Tank 25K#1 25,000 ST006 Storage Tank 25K#2 25,000(Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Semi-Developed Camp w/ flush toilets Beaver Dam Village SSD Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? Autolink to 4.3 "Total Existing Storage Capcity" cell below. If applicable, enter number of people per camp site here. Storage deficit indicates that: (1) additional storage volume is needed, and (2) storage deficiency should be assessed. Use this number in Cell I8 ("Number of residential connections") on Page 1 to calculate PROJECTED demand & req'ts (including both existing & future connections). Diaphragm or air pressure tanks shall NOT be considered effective storage volume for (1) community systems, or (2) NTNC with significant demand UNLESS an exception has been granted. Autolink to 2 "Total Storage" cell above. If applicable, use this number in cell I8 or cell I9 on Page 1. If NO, answer one of question set 2.01 to 2.05 in ESS.If YES, answer one of question set 2.06 to 2.10 in ESS. Less than 100% indicates: (1) additional storage capacity is needed, and (2) storage deficiency should be assessed. Beaver Dam Village SSD Capacity 2025 Page 2 of 2 7/18/2025