Loading...
HomeMy WebLinkAboutDERR-2025-005196Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name UTAH STATE FUEL NETWORK Address 4315 S 2700 W SALT LAKE CITY, UT 84129 Contact UTAH STATE FUEL NETWORK Phone Email brettgurney@utah.gov TANK LOCATION Name ROY CITY SHOPS Address 5460 S 2700 W ROY, UT 84067 A Operator BRETT GURNEY Phone (801) 957-7261 B Operator GEORGE STURM Phone (385) 602-4872 Facility ID: 1200423 Inspection Date: 07/11/2025 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 3 - 1/2 Gas/Diesel Yes Steel Flex in Sump Jan. 22, 2025 Jan. 22, 2025 Yes No Jan. 24, 2025 None 4 - Transition Gas/Diesel Yes Steel Flex in Sump Jan. 22, 2025 Jan. 22, 2025 No No None None TANK DETAILS Tank ID/Alt ID 4 / 1A E-Gen/AST No / Yes Siphon/Compart No / Yes Tank Status Currently In Use Installed/Cap/Loc Jan. 22, 2025 / 6000 / North Substance Stored Gasoline / Regular Tank Material- Mod Asphalt Coated or Bare Steel- Double-Walled ATG Veeder Root / TLS-300 LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / Double-Walled Pipe type/STP Cont Pressurized / Yes STP Flex Connectors Steel Flex in Sump LLD Model Red Jacket / VR FX1DV Spill/Overfill/Sm Delivery 5 gal. Per Prod. APST Cont. Sump / Overfill alarm / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 5 / 1B E-Gen/AST No / Yes Siphon/Compart No / Yes Tank Status Currently In Use Installed/Cap/Loc Jan. 22, 2025 / 4000 / South Substance Stored Diesel / Tank Material- Mod Asphalt Coated or Bare Steel- Double-Walled ATG Veeder Root / TLS-300 LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / Double-Walled Pipe type/STP Cont Pressurized / Yes STP Flex Connectors Steel Flex in Sump LLD Model Red Jacket / VR FX1DV Spill/Overfill/Sm Delivery 5 gal. Per Prod. APST Cont. Sump / Overfill alarm / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS 2025-07-11 Page 1 of 4 None 2025-07-11 Page 2 of 4 FACILITY RESPONSES Financial Responsibility Financial responsibility method is ok?Yes The above accurately represents the facility's release detection records Yes TANK RESPONSES Tank 1A Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 1B Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 1B Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 1A Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 1A Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 1B Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes DISPENSER RESPONSES Dispenser Transition Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 1/2 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Jul '24 Aug '24 Sep '24 Oct '24 Nov '24 Dec '24 Jan '25 Feb '25 Mar '25 Apr '25 May '25 Jun '25 Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 5 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2025-07-11 Page 3 of 4 Prepared by fueloperator.com Inspection Information Inspector:Ottley, Melissa Record Created:July 11, 2025, 10:35 a.m. Inspection Date:July 11, 2025 2025-07-11 Page 4 of 4