Loading...
HomeMy WebLinkAboutDERR-2025-0051467/10/2025 M.O. 7/10/2025 36.0' D D DE F 10.0' D D STRM STRM STRM STR M STR M STR M STR M STR M STR M 28.4' P I-84 13 0 1 A c a d e m y C o u r t , F o r t C o l l i n s C O 8 0 5 2 4 T e l : ( 9 7 0 ) 4 9 3 - 7 7 8 0 w w w . c g r s . c o m DATE:DRAWN BY: SHEET: G-001 SITE #:PROJECT #: TI T L E : PR O J E C T I N F O R M A T I O N : TH E U S E O F T H E S E D R A W I N G S A N D S P E C I F I C A T I O N S S H A L L B E R E S T R I C T E D T O T H E OR I G I N A L U S E F O R W H I C H T H E Y W E R E P R E P A R E D . R E U S E , R E P R O D U C T I O N , MO D I F I C A T I O N O R P U B L I C A T I O N , I N W H O L E O R I N P A R T , I S P R O H I B I T E D W I T H O U T TH E W R I T T E N C O N S E N T O F T H E E N G I N E E R O F R E C O R D A N D C G R S , I N C . RE V DA T E RE V I S I O N S DE S QC A B C D E A B C D E 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SNOWBASIN RESORT CONTACT: BO BOWMAN, P.E., 1301 ACADEMY CT. FORT COLLINS, CO 80524 PH#: (970) 493-7780 1. NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE/NFPA 30A, MOTOR FUEL DISPENSING FACILITIES REPAIR CODE. 2. NFPA 70, NATIONAL ELECTRIC CODE (NEC) 3. U.S. DEPT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) 29 CFR 1910.206, FLAMMABLE AND COMBUSTIBLE LIQUIDS, & 29 CFR 1910.106, PERSONAL PROTECTIVE EQUIPMENT. A. UST REMOVAL GUIDANCE AND REFERENCES: 4. PEI: PUBLICATION RP1700 - RECOMMENDED PRACTICES FOR THE CLOSURE OF UNDERGROUND STORAGE TANK AND SHOP-FABRICATED ABOVEGROUND STORAGE TANK SYSTEMS. 5. API: 1604 CLOSURE OF UNDERGROUND PETROLEUM STORAGE TANKS. 6. API: 2003 PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, AND STRAY CURRENTS. 7. API: 2015 REQUIREMENTS FOR SAFE ENTRY AND CLEANING OF PETROLEUM STORAGE TANKS. B. UST INSTALLATION GUIDANCE AND REFERENCES: 8. PETROLEUM EQUIPMENT INSTITUTE (PEI) INSTALLATION i. PUBLICATION RP 100 - RECOMMENDED PRACTICES FOR INSTALLATION OF UNDERGROUND LIQUID STORAGE SYSTEMS. ii. PUBLICATION RP 300 - RECOMMENDED PRACTICES FOR INSTALLATION AND TESTING OF VAPOR RECOVERY SYSTEMS. iii. PUBLICATION RP 500 - RECOMMENDED PRACTICES FOR INSPECTION AND MAINTENANCE OF MOTOR FUEL DISPENSING EQUIPMENT. iv. PUBLICATION RP 1200 - RECOMMENDED PRACTICES FOR THE TESTING AND VERIFICATION OF SPILL, OVERFILL, LEAK DETECTION AND SECONDARY CONTAINMENT EQUIPMENT AT UST FACILITIES. 9. UNDERWRITERS LABORATORIES, INC. (UL) i. UL-1316 FIBERGLASS UNDERGROUND TANKS FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS. ii.UL-971 FRP NONMETALLIC UNDERGROUND PIPING FOR FLAMMABLE LIQUIDS. iii. UL-2039 FLEXIBLE CONNECTOR PIPING FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS. iv.UL-330 A&B HOSE AND HOSE ASSEMBLIES FOR USE WITH DISPENSING DEVICES. CGRS, INC. G-001 TITLE SHEET 0 15 20 30 SCALE IN FEET 5 10 25 C-100 CGRS INC. C-101 NORTH CONTACT: JAKE HURLBUT 1301 ACADEMY CT. FORT COLLINS, CO 80524 PH#: (970) 493-7780 CONTACT: 3925 E OLD SNOWBASIN RD HUNTSVILLE, UT 84317 PH#: (888) 437-5488 LEGEND WA R N I N G : T H I S D R A W I N G M A Y H A V E B E E N R E D U C E D FR O M I T S O R I G I N A L S C A L E REMOVE ONE (1) 11K-GAL SPLIT-COMPARTMENT UST AND INSTALL ONE (1) 16K-GAL SPLIT-COMPARTMENT DOUBLE WALL FIBERGLASS UST FOR FLEET FUELING. THE TASKS ARE AS FOLLOWS: 1. REMOVE EXISTING FUEL ISLAND. REMOVE TWO (2) DISPENSERS AND RELOCATE FUELMASTER CARD READER FOR REINSTALL. DEMO FUEL ISLAND CONCRETE. 2. RELOCATE 2K-GAL DEF TANK FOR NEW FUEL ISLAND. 3. REMOVE ONE (1) UST. DEMO CONCRETE/ASPHALT OVER UST AREA. 4. CLOSURE PLAN AND NOTIFICATIONS TO UT DEPARTMENT OF ENVIRONMENTAL QUALITY AND WEBER FIRE DISTRICT. REQUIREMENTS INCLUDING 10-DAY NOTIFICATION. ENVIRONMENTAL SAMPLING PER UT DEQ. 5. EXCAVATE SOIL FOR NEW UST & PIPING INSTALLATION. 6. PERMIT & INSTALL ONE (1) 16K-GAL SPLIT-COMPARTMENT (4K RUL / 12K DSL) UL-2085 DOUBLE WALL FIBERGLASS UST. 7. INSTALL ANCILLARY TANK TOP EQUIPMENT. 8. INSTALL 3" OVER 2" DOUBLE-WALLED FRP PIPING & FRP SUMPS. 9. INSTALL NEW CONCRETE FUEL ISLAND & LIGHTPOLE PIERS. 10. INSTALL ONE (1) SINGLE-PRODUCT TWO HOSE DISPENSER & ONE (1) MULTI-PRODUCT TWO HOSE DISPENSER. 11. REINSTALL EXISTING 2K-GAL DEF TANK & EXISTING CARD READER. 12. INSTALL TWO (2) LIGHTPOLES ONTO FUEL ISLAND PIERS. 13. INSTALL ELECTRICAL. 14. IOTA TESTING OF PIPING & COMMISSIONING OF UST PER UT DEQ. C-201 CONCRETE PLAN 1 EXISTING UNDERGROUND STORAGE TANK (UST) G-002 BUILDING DESIGN CODES 1. 2021 INTERNATIONAL BUILDING CODE (IBC) 2. 2023 NATIONAL ELECTRICAL CODE (NEC) 3. 2021 INTERNATIONAL FIRE CODE (IFC) 4. 2021 NFPA30 5. 2021 NFPA30A 6. UTAH PETROLEUM STORAGE TANK PROGRAM VICINITY MAP NO T T O S C A L E DEF (DIESEL EXHAUST FLUID) M-100 SPLIT TANK DRAWING M-200 TANK ANCILLARY EQUIPMENT M-300 FUEL PIPING DETAILS E-100 ELECTRICAL SINGLE LINE E-STOP STORM SEWER LINE (EXISTING) WATER LINE (EXISTING) STRM SPECIFICATIONS DEMO PLAN PIPING PLAN SHEET #TITLE DESIGN CODES DESIGN STANDARDS SCOPE OF WORK CONTRACTORCLIENT ENGINEER 3925 EAST OLD SNOWBASIN ROAD, HUNTSVILLE, UT 84317 NEW LOW-FLOW MULTI-PRODUCT (RUL & DSL) DISPENSER EXISTING DEF FOR RELOCATION 6/6/2025 JH 22060 29508 TI T L E S H E E T 0 5 SCALE IN MILES 1 2 3 4 EXISTING FUEL ISLAND FOR REMOVAL EXISTING 11K-GAL UST FOR REMOVAL NEW HIGH-FLOW SINGLE-PRODUCT (DSL) DISPENSER EXISTING DEF NEW LOCATION ELECTRICAL SN O W B A S I N R E S O R T 39 2 5 E O L D S N O W B A S I N R O A D HU N T S V I L L E , U T 8 4 3 1 7 C-202 CONCRETE PLAN 2 NEW UST FIRE HYDRANT NEW UST 16K-GAL DW SPLIT (4K RUL / 12K DSL) EXISTING UST CONCRETE COVER NEW LIGHTPOLE (2) T R A P P E R S L O O P R O A D HW Y 8 9 OGDE N C A N Y O N ROAD SITE T1 T2 USC P1USC DSP1USC Piping