Loading...
HomeMy WebLinkAboutDDW-2024-005973SITE LOCATION Ͳ LATIThE ϯϳ͘ϯϳϯϰϵϵ͕ LON'IThE ͲϭϭϮ͘ϵϴϰϱϲϯ DA I N S T R E E T <OLO RESERsOIR hϭϰ CONTINhES OsER CEAR DOhNTAIN RI',T ,AN CANzON ROA Iϭ ϱ T O S A L T L A < E C I T z Iϭϱ T O S T ͘ ' E O R ' E DILTS STA'E STOW LAsA WOINT ROA Ͳ CAN E ACCESSE &ROD sIR'IN AN ,I',WAz ϵ TOWAR SWRIN'ALE <OLO TERRACE ROA <OLO ROA TOWNS,IW ϯϵ S RAN'E ϭϬ W͕ SECTION ϯϮ͕ WARCEL ηϭϮϬ SEE S,EET 'Ϭ͘Ϯ ϮϬϬϬ T,E C,hRC, O& :EShS C,RIST O& LATTER Az SAINTS ,ENERSON͕ NEsAA LS zOhT, CADW SCALE IN &EET ϭϬϬϬϬ hILIN' NEAREST TO WROWERTz LINE х ϭ͕ϬϬϬ &T͘ ϭ SCALE: sARIES SITE LOCATION AN sICINITz DAW <OLO EER ,AsEN RCDW C,LORINATION WRO:ECT ;ϱϭϯͲϲϲϲϬͲϮϯϬϴϬϭϬϭͿ WRO:ECT ESCRIWTION: ϭ͘CONSTRhCT A C,LORINATION hILIN' NEAR T,E WATER STORA'E TAN<S͘ Ϯ͘CONSTRhCT A SOLAR ARRAz AN ATTERz WOWER ShWWLz SzSTED TO ACCODDOATE sALsE CONTROLS AN IN:ECTION AT T,E hILIN' AN TAN<S͘ ϯ͘INSTALL A C,LORINATION SzSTED WIT, T,E AWWROWRIATE WIWIN'͕ sALsES AN CONTROLS IN T,E hILIN' AN AT T,E TAN<S͘ ϰ͘INSTALL A C,LORINE RESIhAL TESTIN' STATION AN CONSTRhCT A SOLAR ARRAz AN ATTERz WOWER ShWWLz SzSTED AT T,E CENTRAL S,OWER ,OhSE͘ ϱ͘INSTALL A C,LORINE RESIhAL TESTIN' STATION AN CONSTRhCT A SOLAR ARRAz AN ATTERz WOWER ShWWLz SzSTED AT T,E DENΖS RESTROOD͘ 'Ϭ͘ϭ: COsER͕ sICINITz DAW͕ S,EET INEy AN WRO:ECT ESCRIWTION 'Ϭ͘Ϯ: SITE DAW AN 'ENERAL NOTES SϬ͘ϭ: 'ENERAL STRhCThRAL NOTES SϬ͘Ϯ: SWECIAL INSWECTION AN TESTIN' NOTES AN TALES SϬ͘ϯ: TzWICAL ETAILS AN SC,EhLES Sϭ͘Ϭ: C,LORINATION hILIN' SITE AN WLAN sIEWS SϮ͘Ϭ: ELEsATIONS SϮ͘ϭ: OOR AN sENT ETAILS Sϯ͘Ϭ: SECTION &RONT TO AC< Sϯ͘ϭ: SECTION SIE TO SIE Sϰ͘Ϭ:ETAILS Cϭ͘Ϭ: CADW IDWROsEDENTS SITE WLAN Cϭ͘ϭ: C,LORINE hILIN' SITE WLAN Cϭ͘Ϯ: 'ENERAL CIsIL NOTES CϮ͘Ϭ: 'ENERAL CIsIL ETAILS Ͳ ϭ Dϭ͘Ϭ: DEC,ANICAL WLAN Dϭ͘ϭ: C,LORINE OSIN' WRCS͘ SzSTED SC,ED͘ DϮ͘Ϭ: WIWE DATERIAL SC,EhLE DϮ͘ϭ: 'ENERAL DEC,ANICAL ETAILS Ͳ ϭ DϮ͘Ϯ: 'ENERAL DEC,ANICAL ETAILS Ͳ Ϯ Eϭ͘Ϭ:ELECTRICAL SzDOLS AN NOTES EϮ͘Ϭ:ELECT͘ C,LORINATION L'͘ WLAN sIEW EϮ͘ϭ: ELECT͘ RSTRD͘ AN CENT͘ S,WR͘ WLAN sIEW Eϯ͘Ϭ: ELECTRICAL CONTROL IA'RADS Eϰ͘Ϭ:Ws WIRIN' IA'RADS Eϰ͘ϭ: ELECT͘ CONTROLS WIRIN' IA'RADS Eϱ͘Ϭ: 'ENERAL ELECTRICAL ETAILS S,EET INEy: WAS,IN'TON COhNTz WROWERTz ESCRIWTION: OWNER:LS CORWORATION O& T,E WRESIENT O& T,E C,hRC,͕ ϱϬ EAST NORT, TEDWLE STREET͕ STE ϮϮϮϱ͕ SALT LA<E CITz͕ hTA, ϴϰϭϱϬ sIR'IN RIsER &ACILITIES DANA'ER: LAWRENCE &EAT,ERSTONE ;ϰϯϱͿ ϲϳϯͲϰϵϴϯ͘ ϭ WARCEL : ENTIRE WARCEL ϭϮϬ: ϰϲϬ ACRES LE'AL ESCRIWTION: S: ϯϮ T: ϯϵS R: ϭϬW ALL SEC ϯϮ TϯϵS RϭϬW SLD Property Number: Plan Series: Project Number: Release Date: KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Pr o j e c t f o r : Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 COVER VICINITY MAP SHEET INDEX PROJ. DESC. G0.1 - - Ma r k De s c r i p t i o n Da t e (D - M - Y ) - - - - - - - - - - - - ROA ϭ: &ASTEST ROhTE TO CADW ROA Ϯ:ROhTE WIT, DIL SLOWES INTO CADW &IRE ESCAWE ROA TIE ROA T,ROh', TAN< AREA 1 2 KEYNOTES : APPROXIMATE LOCATION OF EXISTING WATER LINES, TANKS AND VALVES AND TOPOGRAPHY. TOPOGRAPHY IS INCLUDED TO SHOW GENERAL SLOPES, BUT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. THE BOWEN AND COLLINS SHEETS SHALL BE REFERRED TO FOR ALL WATER SYSTEM, MECHANICAL, ELECTRICAL AND PHOTOVOLTAIC SYSTEM UPDATES. SEE S SHEETS FOR BUILDING. COORDINATION DURING LAYOUT WITH OWNER AND ENGINEER OF RECORD IS REQUIRED. APPROXIMATE LOCATION OF WATERLINES TO AND FROM CHLORINATION BUILDING. SEE BOWEN AND COLLINS SHEETS. APPROXIMATE LOCATION OF SOLAR CELLS AND AND BATTERY PACK TO BE MOUNTED TO THE SIDE OF THE BUILDING. SEE BOWEN AND COLLINS SHEETS. SOLAR CELLS AND BATTERY PACK TO BE MOUNTED TO THE WALL OF THE CENTRAL SHOWER BUILDING WITH THE TESTING COMPONENTS AND CONTROLS INSIDE THE MECHANICAL ROOM. SOLAR CELLS AND BATTERY PACK TO BE MOUNTED TO THE WALL OF THE MEN'S RESTROOM WITH THE TESTING COMPONENTS AND CONTROLS INSIDE THE MECHANICAL ROOM. 3 4 5 6 1 SCALE: NONE SITE/RESTROOM LAYOUT GENERAL NOTES: A.THE INVITED CONTRACTORS HAVE VISITED THE SITE PRIOR TO SUBMITTING BID AND SHALL REFER TO THE PROJECT SPECIFICATIONS FOR ALL ITEMS NOT NOTED. B.ALL SAFETY AND CLEANUP AT THE SITE IS THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL ALSO PROVIDE RESTROOM AND TRASH DISPOSAL FACILITIES DURING THE PROJECT. ALL CONSTRUCTION WASTE SHALL BE REMOVED FROM THE SITE. POWER WILL NOT BE PROVIDED, BUT WATER CAN BE TAKEN FROM THE SITE. HOWEVER, IF MORE WATER THAN A STANDARD TAP CAN PROVIDE IS REQUIRED DURING COMPACTION, THE CONTRACTOR SHALL MAKE ARRANGEMENTS TO PROVIDE WATER. ANY COSTS SHALL BE CONSIDERED BEFORE SUBMITTING A BID AND WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. C.ALL WORK SHOWN IN THE DRAWINGS RELATIVE TO THE FINAL CONDITION OF THE PROJECT IS THE CONTRACTOR'S RESPONSIBILITY AND UNLESS A LEGITIMATE SCOPE OF WORK CHANGE OR EXTREME UNFORESEEN CONDITIONS ARE ENCOUNTERED, THE CONTRACTOR WILL BE RESPONSIBLE TO COMPLETE THE WORK DETAILED.. D.ALL GRADING, SOILS, GRAVEL, DISPOSAL AND PRODUCTS NECESSARY FOR PROJECT COMPLETION SHALL BE INCLUDED IN BID ACCOUNTING FOR VARIOUS EXISTING CONDITIONS. E.THE WASHINGTON COUNTY BUILDING DEPARTMENT WAS CONTACTED AND IT WAS AGREED THAT NO PERMIT WILL BE EXPECTED FOR THE BUILDING. HOWEVER, THE GEOTECHNICAL, CIVIL AND STRUCTURAL REQUIREMENTS WILL STILL BE MET AND SPECIAL INSPECTION AND MATERIALS TESTING WILL STILL BE OCCURRING. F.THE WATER SYSTEM PERMITTING WILL BE COORDINATED THROUGH BOWEN AND COLLINS. G.THE CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH LANDMARK TESTING FOR COMPACTION TESTING AND CONCRETE TESTING. THEIR SERVICES WILL BE UNDER SEPARATE CONTRACT BUT COORDINATION IS THE RESPONSIBILITY OF THE CONTRACTOR. RECORDS OF THE TESTS SHALL BE PROVIDED TO CDCE. H.ALL CONCRETE SHALL BE MIX TYPE F AS DEFINED IN THE SPECIFICATIONS. THE CONTRACTOR SHALL PROVIDE DELAY-SET ADDITIVES AS NECESSARY TO MEET THE SPECIFIED REQUIREMENTS WHILE ACCOUNTING FOR THE DISTANCE FROM THE BATCH PLANT. PROVIDE SEALER/HARDENER AT EACH CONCRETE SURFACE PER THE SPECIFICATIONS. I.ANY WATER/ELECTRICAL/SEWER LINES SHALL BE PROTECTED IN PLACE AND THOSE LINES INTERSECTED/DAMAGED DURING THE INSTALLATION OF NEW IMPLEMENTS SHALL EITHER BE SPLICED/REPAIRED OR MODIFIED AT THE CONTRACTOR'S EXPENSE. J.CDCE SHALL APPROVE THE WORK AT THE FOLLOWING TIMES, BEFORE WORK CAN CONTINUE: J.A.AT A PRE-CONSTRUCTION MEETING. J.B.AT CHLORINATION BUILDING LOCATING AND SOLAR BASE/TOWER LOCATING. J.C.AFTER FORM-WORK INSTALLATION AND BEFORE CONCRETE PLACEMENT AT EACH STAGE. J.D.BOWEN AND COLLINS WILL BE PRESENT FOR THE PRE-CONSTRUCTION MEETING AND TO OBSERVE STARTUP, TRAINING AND COMMISSIONING. J.E.AFTER ALL SYSTEMS ARE OPERATIONAL, TESTED AND THE SITE GRADING HAS BEEN COMPLETED. K.ONLY APPROXIMATE WATERLINE LOCATIONS ARE AVAILABLE AND THE CONTRACTOR IS RESPONSIBLE TO INVESTIGATE AND COORDINATE WITH THE BOWEN COLLINS RECORD DRAWINGS PRIOR TO INSTALLATION. THE CONTRACTOR SHALL ACCOUNT FOR ADEQUATE PIPE AND FITTINGS TO ACCOMPLISH THE WORK DETAILED. L.THE FINAL LAYOUT FOR THE CHLORINATION BUILDING AND SOLAR TOWER SHALL BE COORDINATED AND LAID OUT TOGETHER WITH THE OWNER AND THE ENGINEER OF RECORD TO MINIMIZE THE NUMBER OF TREES REMOVED. THE CONTRACTOR SHALL PROVIDE A LASER, PAINT, STAKES AND TAPE AS NECESSARY FOR THIS PROCESS. M.ALL TREES/VEGETATION, ROCKS/DEBRIS ENCOUNTERED IN GAINING ACCESS TO THE SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE EXCAVATED, GRADED, DISPOSED OF, AS REQUIRED TO COMPLETE THE PROJECT. N.ALL TREES LARGER THAN 3" IN DIAMETER THAT MUST BE FELLED, MOVED, CUT, ETC. SHALL BE CUT INTO 20" LENGTHS AND SHALL BE STOCKPILED (STACKED NEATLY) NEAR THE CLOSEST FIRE PIT IN A MANNER THAT DOES NOT IMPEDE TRAVEL, DRAINAGE OR WALKING FLOW AND DOES NOT POSE A FIRE RISK BASED ON PROXIMITY TO THE EXISTING FIRE RINGS. ALL TREES/SHRUBS SMALLER THAN 3" SHALL BE HAULED OFF AND DISPOSED OF. O.ANY TREES THAT MUST BE FELLED FOR PROJECT INSTALLATION MUST BE DISPOSED OF PER NOTE N. P.ALL DEBRIS SHALL BE REMOVED FROM THE SITE AND HAULED OFF BY THE CONTRACTOR. NO DEBRIS SHALL BE LEFT IN AREAS OF CONSTRUCTION OR ON THE SITE. ANY EXISTING PILES OF DEBRIS THAT ARE CLEARLY OUT OF THE AREA OF WORK SHALL BE LEFT AND NO NEW MATERIALS SHALL BE ADDED TO THEM. ANY EXISTING PILES HAVING DEBRIS ADDED TO THEM WILL BECOME THE RESPONSIBILITY OF THE CONTRACTOR AND WILL HAVE TO BE HAULED OFF AT THE CONTRACTOR'S EXPENSE. Q.ALL AREAS SHALL BE LOCATED/GRADED TO PROVIDE ADEQUATE DRAINAGE FROM THE BUILDING, AND ALL SOILS SHALL BE CLEANED AND RAKED, GRADED TO PROVIDE A PLEASING FINISH AT THE COMPLETION OF WORK.AS REQUIRED, ADDITIONAL SOILS FOR FINE GRADING MAY BE TAKEN FROM THE ADJACENT AREA. AT THE COMPLETION OF THE PROJECT, THE SITE MUST BE CLEAN AND PLANAR AND OPERABLE FOR ITS INTENDED PURPOSE. ALL EDGES MUST BE BLENDED AND RAKED SMOOTH. THE CONTRACTOR SHALL ACCOUNT FOR THE SPECIFIED FILL MATERIALS, ROAD BASE AND PEA GRAVEL TO ACCOMPLISH THE WORK. R.THE TOP OF SLAB SHALL BE LOCATED AS SHOWN IN THE PLAN VIEW AND BUILDING SECTIONS. S.ALL STUMPS WITHIN 30' OF THE RADIUS OF THE BUILDING SHALL BE REMOVED AND DISPOSED OF AND THE HOLES BACKFILLED. T.AFTER ALL FINE GRADING AT DISTURBED AREAS HAS BEEN COMPACTED BACK INTO PLACE AND RAKED SMOOTH, SEED AND FERTILIZER SHALL BE PROVIDED AT THE FOLLOWING MIX AND RATE: T.A.REMOVE ALL STICKS, STONES 2" IN DIAMETER AND LARGER AND REMOVE ALL OTHER DEBRIS DETRIMENTAL TO APPLICATION, OR GROWTH. T.B.APPLY SEED BY THE DRY METHOD. APPLY WITH SEEDERS OR DRILLS TO ENSURE ADEQUATE PENETRATION AND LIGHTLY COMPACT SURFACE AFTER INSTALLATION. T.C.SEED MIX SHALL BE PURE LIVE SEED TO THE FOLLOWING RATIOS: T.C.A.TYPE OF SEED:QUANTITY OF PURE LIVE SEED (LBS/ACRE): T.C.B.CRESTED WHEAT GRASS (FAIRWAY)3 LBS - 13.6% T.C.C.INTERMEDIATE WHEATGRASS (OAHE)3 LBS - 13.6% T.C.D.TRITICALE 12 LBS - 54.6% T.C.E.INDIAN RICEGRASS (RIMROCK)2 LBS - 9.1% T.C.F.WESTERN WHEATGRASS (VNS)2 LBS - 9.1% T.D.AFTER INSTALLATION AND RE-RAKING, PROVIDE LIQUID APPLIED SPRAY FERTILIZER (READILY AVAILABLE WITH THE LEAST PERCENTAGE OF NUTRIENTS POSSIBLE). Property Number: Plan Series: Project Number: Release Date: KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Pr o j e c t f o r : Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 SITE MAP AND GENERAL NOTES G0.2 - - Ma r k De s c r i p t i o n Da t e (D - M - Y ) - - - - - - - - - - - - 1 2 3 4 5 6 CRITICAL NOTES: SCHEDULE NOTES/TIMELINE: 1.THE CONTRACTOR MUST BE PREPARED TO ENTER THE SITE AND START WORK ON MAY 1ST, 2024 AND MUST KEEP THEIR SCHEDULE/CAPACITY OPEN TO START WORK WITHIN THREE BUSINESS DAYS OF BEING NOTIFIED THAT THE SITE IS ACCESSIBLE. 2.IT IS EXPECTED THAT THE CONTRACTOR WILL WORK CONTINUOUSLY AND AGGRESSIVELY TO MEET THE CONTRACTED TIMELINE AND HAVE THE BUILDING SUBSTANTIALLY COMPLETE AND THE WATER SYSTEM OPERATIONAL STARTING THE FIRST WEEK THE SITE IS ACCESSIBLE TO ENSURE STATE COMPLIANCE AND SOON AS POSSIBLE AND AVOID THE NEED FOR CAMPERS TO HAUL WATER. 3.THIS WILL PARTIALLY ACCOMPLISHED BY HAVING ALL SUBMITTALS IN AND APPROVED WITHIN 30 DAYS OF CONTRACT AWARD ALL ALL PARTS ORDERED AND IN THE CONTRACTOR'S POSSESSION PRIOR TO START OF WORK. UTAH DRINKING WATER REQUIREMENTS: 1.AN OPERATING PERMIT WILL BE OBTAINED FROM THE STATE OF UTAH AND THE CONTRACTOR IS RESPONSIBLE TO COMPLETE THE WORK PER SPECIFICATION AND DETAILS BEFORE THE SYSTEM CAN BE CONSIDERED COMPLIANT. EXCAVATION NOTES: 1.EXPLORATORY TEST HOLES HAVE BEEN MADE. 2.IN EACH LOCATION, THE SOILS WERE TIGHT, SLOW DIGGING, CONSISTING OF TIGHT SOIL/CLAYS AND IN SOME CASES SOME SHALE. THE SHALE WAS EASILY BROKEN UP AND DUG THROUGH. 3.THE TEST HOLE WORK WAS PERFORMED WITH A MINI-EXCAVATOR AND DIGGING SHOULD BE POSSIBLE WITH ANY TYPICAL SIZE BACKHOE (IN GOOD WORKING ORDER) OR EXCAVATOR OF EQUAL OR LARGER SIZE. (A TYPICAL SIZE BACKHOE WOULD INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: JOHN DEER 310, CASE 580, FORD NEW HOLLAND B95 WITH 14' MINIMUM EXCAVATION CAPACITY AND 90 HP MIN.) 4.THE USE OF A "HOE RAM" OR ROCK BREAKER IS NOT ANTICIPATED AND ITS REQUIREMENT BEYOND THE EQUIPMENT NOTED WOULD BE CONSIDERED A CHANGE OF CONDITIONS. 5.THE CONTRACTOR SHALL ANTICIPATE HARD/SLOW DIGGING AS PART OF THE PROJECT. APP R O X . 1 0 ' F R O M T H E E D G E O F R O A D - F I E L D L A Y O U T W I T H E . O . R . CLOSEST FIRE PIT Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 02/03/24 513-6660-23080101 N/A 513-6660 GENERAL STRUCTURAL NOTES KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S0.1 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. GENERAL CONDITIONS THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEERS IN THIS OR SIMILAR LOCALITIES. THEY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. WHERE SPECIFIC DETAILS ARE NOT SHOWN, TYPICAL DETAILS/NOTES SHALL APPLY. ALL CONSTRUCTION SHALL CONFORM WITH CURRENT CODES AND STANDARDS ENFORCED FOR THE SPECIFIC JURISDICTION UNLESS A HIGHER STANDARD IS REQUIRED BY THE BUILDING OFFICIAL. ALL REFERENCES TO SPECIFIC CODES/SUPPLEMENTS/ADDENDUM REFER TO CURRENTLY ENFORCED CODE FOR THE JURISDICTION. THIS APPLIES TO ALL TESTING REQUIREMENTS, MATERIAL SPECIFICATIONS, ETC., U.N.O. THESE DRAWINGS DO NOT INDICATE THE METHOD OF CONSTRUCTION BUT REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DETERMINING THE MEANS, METHODS, SEQUENCES AND TECHNIQUES TO COMPLETE THE PROJECT. THESE DRAWINGS HAVE BEEN PREPARED, IN PART, ON THE BASIS OF INFORMATION COMPILED/PROVIDED BY OTHERS AND THEY ARE NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION, TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE ENGINEER OF RECORD WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB SAFETY AND SHALL ASSURE THAT ALL LOCAL, STATE AND FEDERAL SAFETY REGULATIONS ARE ENFORCED ON THE JOB SITE, INCLUDING ALL OSHA REGULATIONS. THE CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FINISHES THAT MAY BE AFFECTED BY STRUCTURAL WORK SHOWN IN THESE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL COORDINATE WITH THE ARCHITECT WITH ANY QUESTIONS PRIOR TO PURCHASING OR INSTALLING MATERIALS. AUTHORIZATION SHALL BE RECEIVED IN WRITING BEFORE ANY WORK SHALL COMMENCE THAT DEVIATES FROM THE CONTRACT DOCUMENTS. NO ALLOWANCES WILL BE MADE FOR ITEMS SHOWN ON DRAWINGS THAT WERE MISSED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF RECORD IMMEDIATELY IF ANY CONDITIONS NOT SHOWN IN THE DRAWINGS ARE ENCOUNTERED. ALL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE MANUFACTURER'S RECOMMENDATIONS FOR THE METHOD, MANNER AND APPLICATION OF INSTALLATION UNLESS SPECIFICALLY NOTED OTHERWISE IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING AND SUPPORT OF ALL STRUCTURAL MEMBERS AND STRUCTURAL SYSTEMS DURING CONSTRUCTION. DURING AND AFTER CONSTRUCTION THE CONTRACTOR AND/OR OWNER SHALL KEEP LOADS ON THE STRUCTURE WITHIN THE LIMITS OF THE DESIGN LOADS. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IN PLACE ON FRAMED FLOORS OR ROOF. DO NOT SCALE DRAWINGS. IF A DIMENSION IS NOT SHOWN, CONTACT CD CONSULTING ENGINEERS FOR GUIDANCE. OBSERVATION/SITE VISITS TO THE JOB BY CD CONSULTING ENGINEERS FIELD REPRESENTATIVES SHALL NEITHER BE CONSTRUED AS INSPECTION NOR APPROVAL OF CONSTRUCTION. REFER TO THE PROJECT SPECIFICATIONS FOR INFORMATION SHOWN BUT NOT NOTED. IF ANY CONFLICTS/DISCREPANCIES ARE DISCOVERED BETWEEN THE SPECIFICATIONS AND THE DRAWINGS, THE MORE STRINGENT REQUIREMENTS SHALL BE MET. ALL ENGINEERING PROVIDED BY OTHERS AS A DEFERRED SUBMITTAL/SHOP DRAWINGS, ETC. SHALL BEAR THE APPROPRIATE SEAL FOR THE STATE IN WHICH THE PROJECT IS OCCURRING. ALL EXCAVATIONS SHALL OCCUR IN A SAFE AND THOUGHTFUL MANNER ENSURING THE SAFETY AND STABILITY OF ALL EXISTING SOILS AND STRUCTURES. PRIOR TO DIGGING, THE CONTRACTOR SHALL CONTACT BLUE STAKES (OR THE REGION SPECIFIC UNDERGROUND UTILITY LOCATING ENTITY) TO VERIFY THE LOCATION OF ANY UNDERGROUND UTILITIES. THE CONTRACTOR SHALL ALSO COORDINATE WITH THE OWNER TO LOCATE ALL ON-SITE UTILITIES NOT ADDRESSED BY BLUE STAKES. ALL EXCAVATION SHALL BE PERFORMED WITH EXTREME CAUTION AS ANY REPAIRS OF EXISTING UTILITIES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACT DOCUMENTS SHALL GOVERN OVER SHOP DRAWINGS UNLESS SPECIFICALLY NOTED OTHERWISE. NON-BEARING INTERIOR PARTITION WALLS SHALL BE ADEQUATELY BRACED TO THE STRUCTURE ABOVE WITH ALLOWANCE FOR DEFLECTION OF THE ROOFS/FLOORS ABOVE/BELOW. 1. 2. 3. A. B. C. D. E. a. b. c. F. G. H. I. J. 4. A. 5. SOILS AND FOUNDATIONS FROST PROTECTION EMBEDMENT DEPTH:36 IN MIN. ALL WORK SHALL BE PERFORMED BASED ON THE SITE SPECIFIC SOILS REPORT. IF NO REPORT IS AVAILABLE, FOUNDATIONS HAVE BEEN DESIGNED BASED ON IBC ALLOWABLE VALUES AND ALL RESTRICTIONS APPLY. ADDITIONALLY, AT A MINIMUM, THE FOLLOWING SHALL OCCUR: CLEARING: AN AREA EXTENDING 5' OUTSIDE THE BUILDING AND ANY SITE CONCRETE SHALL BE SCRAPED TO REMOVE THE TOP 4" (MIN) OF SOIL INCLUDING ALL VEGETATION AND DEBRIS. SOIL SHALL BE REMOVED UNTIL ALL ORGANIC MATTER HAS BEEN REMOVED. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING FOR EXCAVATIONS AS REQUIRED PER OSHA AND SOIL CONDITION REQUIREMENTS. CONTRACTOR SHALL PREVENT DAMAGE TO OR SETTLEMENT OF ANY NEW OR EXISTING STRUCTURES AND UTILITIES ON OR ADJACENT TO PROJECT SITE. THE NATURAL UNDISTURBED SOIL BELOW ALL FOOTINGS SHALL BE COMPACTED PRIOR TO PLACING STRUCTURAL FILL AND/OR CONCRETE. REMOVE ALL SOFT SPOTS AND REPLACE WITH COMPACTED STRUCTURAL FILL. COMPACTED STRUCTURAL FILL: SPREAD/SPOT FOOTINGS SHALL BEAR ON UNDISTURBED, UNIFORM, NATIVE GRAVEL SOILS OR ENTIRELY ON A MINIMUM OF 12 INCHES OF PROPERLY PLACED AND COMPACTED GRANULAR STRUCTURAL FILL, OR AS DETERMINED BY THE GEOTECHNICAL REPORT. ALL FILL MATERIAL SHALL BE WELL-GRADED, GRANULAR WITH A MAXIMUM SIZE LESS THAN 4" AND WITH NOT MORE THAN 10% PASSING A #200 SIEVE. FILL BENEATH FOOTINGS SHALL BE COMPACTED TO 95% PER ASTM D 1557. COMPACTED STRUCTURAL FILL SHALL BE PLACED IN LIFTS NOT EXCEEDING 8" IN THICKNESS AND ALL FILL SHALL BE TESTED. FILL AND/OR OVER-EXCAVATION SHALL EXTEND A MINIMUM WIDTH EQUAL TO THE DEPTH OF THE BOTTOM OF EXCAVATION OUTSIDE ALL FOOTINGS. CONCRETE SLABS (INTERIOR AND EXTERIOR) SHALL BE UNDERLAIN BY STRUCTURAL FILL AT LEAST 4" THICK. THE STRUCTURAL FILL SHALL HAVE A MAXIMUM SIZE LESS THAN 1" WITH NOT MORE THAN 5% PASSING A #200 SIEVE AND SHALL BE COMPACTED TO AT LEAST 90% PER ASTM D 1557. THE SOILS ENGINEER SHALL REVIEW AND APPROVE ALL EXCAVATIONS AND FILL PLACEMENT PRIOR TO PLACING CONCRETE. CONTRACTOR SHALL PROVIDE DE-WATERING AND DRAINAGE AS REQUIRED TO PROTECT THE SITE/STRUCTURES FROM FLOODING AND/OR WATER DAMAGE. SOILS AGAINST THE FOUNDATIONS AND IN TRENCHES SHALL BE COMPACTED IN LIFTS NOT EXCEEDING 8" TO AT LEAST 90% PER ASTM D 1557. DO NOT PLACE FOOTINGS OR FOUNDATIONS ON INADEQUATE SOILS, UN-COMPACTED FILL, TRASH/DEBRIS, FROZEN SOIL OR IN WATER. IF NO SOILS REPORT IS AVAILABLE, THE FOLLOWING SHALL OCCUR: THE CONTRACTOR SHALL RETAIN A SOILS ENGINEER TO OBSERVE THE EXCAVATIONS AND VERIFY THAT THE ASSUMED SOIL BEARING PRESSURES ARE REASONABLE. FOUNDATION WALLS WHICH RETAIN EARTH MUST BE BRACED AT THE TOP. DO NOT BACKFILL UNLESS BRACING IS PROVIDED OR UNTIL THE COMPLETE FLOOR OR ROOF SYSTEM IS IN PLACE.. A. B. C. D. E. a. b. c. d. BASIS FOR DESIGN GOVERNING CODES: 2021 INTERNATIONAL BUILDING CODE RISK CATEGORY:II SOIL VALUES: SOILS REPORT PRODUCED BY:LANDMARK TESTING AND ENGINEERING, INC. REPORT NUMBER AND DATE:19491, DATED SEPTEMBER 12, 2019 ALLOWABLE BEARING PRESSURE:1,800 PSF + 1/3 INCREASE ALLOWED FOR WIND AND SEISMIC LOADING. LATERAL SOIL PRESSURE EQUIVALENT FLUID DENSITIES: ACTIVE:57 PCF (37 PCF W/OUT SEISMIC) AT REST:55 PCF PASSIVE:280 PCF (330 PCF W/OUT SEISMIC) COEF. OF FRICTION:0.37 ROOF LOADING: 4.1.DEAD LOAD:150 PCF - CONCRETE PER SECTION. 4.2.SNOW LOAD: 4.2.1.PG: 150 PSF (NON-REDUCIBLE) 4.2.2.PF:151.20 PSF 4.2.3.PS:130.3 PSF 4.2.3.1.200 PSF USED FOR DESIGN TO ACCOUNT FOR GLOBAL SITE DRIFT 4.2.4.CE:1.20 4.2.5.CT:1.20 4.2.6.IS:1.00 4.3.LIVE LOAD:20 PSF (REDUCIBLE) WIND LOADING: 5.1.WIND SPEED:115 MPH (V/ULT - (3) SEC GUST) 5.2.IW:1.0 5.3.EXPOSURE:C 5.4.KZT:1.0 5.5.GCPI:+/_ 0.18 5.6.COMPONENT AND CLADDING PRESSURES: 5.6.1.ZONE 4:23 PSF - 30 PSF USED FOR DESIGN 5.6.2.ZONE 5:29 PSF - 30 PSF USED FOR DESIGN SEISMIC DESIGN: 6.1.IE:1.0 6.2.SS:0.550 6.3.S1:0.176 6.4.SITE CLASS:D 6.5.SDS:0.499 6.6.SD1:0.264 6.7.DESIGN CATEGORY:D 6.8.SYSTEM:SPECIAL REINFORCED CONCRETE SHEAR WALLS 6.9.BASE SHEAR:V = C/S*w 6.10.CS:0.097w 6.11.R:5 6.12.W:2.5 6.13.Cd:5 6.14.ANALYSIS:EQUIVALENT LATERAL FORCE PROCEDURE SERVICEABILITY CRITERIA 7.1.INTER-STORY SEISMIC/WIND DRIFT: Δ¢A < 0.02H ('H' IS STORY HEIGHT) 7.2.DEFLECTION LIMITS: 7.2.1.ROOF: L/240 TL / L/360 LL 7.2.2.WALL: N/A / L/180 LL 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. A. B. C. D. a. b. • • • • • • E. F. a. • b. • 1. 2. 3. 4. 5. c. • • 29. CONCRETE ALL CONCRETE SHALL CONFORM WITH ACI 318-19 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", ACI 301-10 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS", ACI 347 "RECOMMENDED PRACTICE FOR CONCRETE FORM-WORK", AND IBC CHAPTER 19 REQUIREMENTS. CONCRETE PROPORTIONING AND APPLICATIONS: SEE SPECIFICATIONS. MATERIALS: CONCRETE SHALL BE PROPORTIONED TO MEET ASTM C94. PORTLAND CEMENT SHALL BE TYPE V AND SHALL CONFORM TO ASTM C150. AGGREGATE SHALL CONFORM TO ASTM C33 NORMAL WEIGHT AGGREGATE. LIMIT NON-PORTLAND CEMENT MATERIALS TO 25% OF THE TOTAL CEMENTITIOUS MATERIAL. FLY-ASH SHALL CONFORM TO ASTM C616 AND SHALL NOT EXCEED 20% ALL CONCRETE SURFACES EXPOSED TO WEATHER SHALL BE AIR ENTRAINED WITH 6% AIR +/- 1.5% PER ASTM C260. AIR ENTRAINMENT SHALL BE MODIFIED WHERE FLY ASH AND ADMIXTURES ARE USED. SAND GRADATION SHALL BE PER ACI 302. PEA GRAVEL AND PLASTICIZERS MAY BE ALLOWED IN CONGESTED AREAS AND UNDER CERTAIN CONDITIONS. SUBMIT PROPOSED AD-MIXTURES WITH CONCRETE MIX DESIGNS. CLASS F POZZOLAN FLY ASH SHALL BE PER ASTM C618. WATER SHALL BE POTABLE. NO ALUMINUM OR PRODUCT CONTAINING ALUMINUM OR ANY METAL INJURIOUS TO CONCRETE SHALL BE EMBEDDED IN CONCRETE. CALCIUM CHLORIDE SHALL NOT BE USED ON ANY CONCRETE UNLESS PRIOR APPROVAL HAS BEEN SECURED IN WRITING FROM THE ARCHITECT OR THE STRUCTURAL ENGINEER. SLUMP SHALL BE MEASURED BEFORE AD-MIXTURES ARE USED. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR REVIEW PRIOR TO PLACEMENT. POLYPROPYLENE FIBER SHALL BE PER ASTM C1116. REINFORCING AND PLACEMENT: ALL STEEL REINFORCEMENT SHALL CONFORM TO ASTM A615 GRADE 60 WITH A MINIMUM YIELD STRENGTH OF 60,000 PSI. EXCEPTION: #3 AND #4 COLUMN TIES, BEAM STIRRUPS, AND BREAKOUT DOWELS, SHALL BE GRADE 40 WITH A MINIMUM YIELD STRENGTH OF 40,000 PSI. REINFORCING BARS SHALL NOT BE WELDED OR BENT BY HEATING. WHERE WELDING IS REQUIRED, BARS SHALL BE ASTM A706, GRADE 60. USE E90XX ELECTRODES PER AWS REQUIREMENTS. DEFORMED BAR ANCHORS SHALL BE PER ASTM A496. CONCRETE ANCHOR BOLTS: SEE STEEL BOLTS AND WASHERS SECTION FOR REQUIREMENTS. REINFORCING BARS SHALL BE DETAILED, BOLSTERED AND SUPPORTED IN ACCORDANCE WITH ACI STANDARD 315, "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES." OR CRSI. CHAIRS, SUPPORT AND TIE BARS REQUIRED IN ADDITION TO THE SCHEDULED REINFORCING SHALL BE FURNISHED BY THE CONTRACTOR. CONCRETE SHALL BE CONSOLIDATED BY PUDDLING OR VIBRATING. AROUND OPENINGS IN CONCRETE SLABS, UNLESS OTHERWISE DETAILED, ADD REINFORCING EQUIVALENT TO BARS CUT BY OPENING WITH HALF ON EACH SIDE OF OPENING AND WITH AT LEAST ONE BAR EACH SIDE OF OPENING. THE BARS PARALLEL TO THE MAIN REINFORCEMENT SHALL RUN THE FULL LENGTH OF THE SPAN. THE BARS PARALLEL TO THE TEMPERATURE STEEL SHALL RUN 48 BAR DIAMETERS EACH WAY BEYOND THE OPENING. PROVIDE #4X4' LONG DIAGONAL BARS AT CORNERS. DOWEL FROM FOOTING OR STRUCTURE BELOW TO STRUCTURE ABOVE WITH SAME BAR SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. DOWELS SHALL HAVE EMBEDMENT PER SCHEDULE INTO WALL ABOVE AND SHALL HAVE A 90° BEND EXTENDING TO 3" FROM THE BOTTOM OF THE FOOTING. BEND HORIZONTAL BARS OR PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS WITH SAME BAR SIZE AND SPACING AS HORIZONTAL WALL REINFORCEMENT. PROVIDE DOWELS FROM EXTERIOR FOUNDATION WALLS FOR ANCHORAGE OF ALL AREAWAY, LANDING, NEW TO EXISTING AND PLANTER WALLS TO MATCH AND LAP WALL REINFORCING. DRILL AND HAMMER IN ALL HORIZONTAL REBAR EXTENDING 6" INTO THE EXISTING WALLS/FOOTINGS WITH 24" MIN. EXTENSION INTO FOOTINGS/WALLS. WHERE CONCRETE WALLS, GIRDERS, PILASTERS OR BEAMS ARE CONTINUOUS AROUND A CORNER, UNLESS OTHERWISE NOTED, THE MAIN REINFORCING BARS IN THE OUTER FACE SHALL BE BENT AROUND THE CORNER 48 BAR DIAMETERS FROM ONE DIRECTION, OR ADD CORNER BARS TO LAP 48 BAR DIAMETERS FROM EACH DIRECTION. REINFORCING BARS IN THE INTERIOR FACES SHALL EXTEND TO WITHIN 2 IN. OF THE OUTER FACE AND SHALL TERMINATE IN A STANDARD HOOK OR BEND. REINFORCING SHALL BE CONTINUOUS BETWEEN ADJACENT STRUCTURES. INTERIOR SLABS-ON-GRADE SHALL BE REINFORCED WITH #3 AT 18" O.C. EACH WAY AND HAVE CONSTRUCTION AND CONTROL JOINTS AS INDICATED IN THE CONSTRUCTION DRAWINGS OR AS PREVIOUSLY NOTED. PROVIDE #3 X 30" DOWELS EMBEDDED 4" AT A 22 1/2° DOWN ANGLE @ 18" O.C. AT ALL SLABS ADJACENT TO THE FOUNDATION. CENTER REINFORCING IN SLABS. FOOTINGS AND GRADE BEAMS SHALL NOT BE PENETRATED UNLESS SPECIFICALLY ALLOWED AND DETAILED BY THE EOR. ALL EMBEDDED ITEMS SHALL BE LAID OUT AND ANCHORED IN PLACE PRIOR TO CONCRETE PLACEMENT. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL REQUIRED EMBEDDED ITEMS WITH ALL TRADES BEFORE PLACING CONCRETE. DO NOT SPLICE STIRRUPS, TIES, VERTICAL BARS IN RETAINING WALLS UNLESS SPECIFICALLY DETAILED. SPLICES MAY BE MADE WITH MECHANICAL DEVICES CAPABLE OF 125% OF THE TENSION CAPACITY OF THE BAR BEING SPLICED. STAGGER BAR SPLICES IN ADJACENT BARS 24" MIN, MECHANICAL OR LAP. HOT WEATHER AND COLD WEATHER CONCRETE SHALL BE INSTALLED UTILIZING THE DIRECTIONS AND REQUIREMENTS OF ACI 305 AND ACI 306, RESPECTIVELY. CONCRETE SHALL NOT BE PLACED IN WEATHER BELOW 36° FAHRENHEIT OR ABOVE 110° FAHRENHEIT. CONCRETE SHALL NOT BE PLACED ON FROZEN GROUND AND CONCRETE PLACED IN COLD WEATHER SHALL NOT BE ALLOWED TO FREEZE UNTIL IT HAS REACHED 3500 PSI. AT THE SIDES AND ACROSS THE BOTTOM OF WALL OPENINGS, ADD TWO #4 BARS THAT EXTEND 24 IN. BEYOND THE CORNERS OF OPENING. BARS SHALL NEVER BE SMALLER THAN THE SCHEDULED WALL REINFORCING. PROVIDE DIAGONAL BARS AT EACH CORNER EXTENDING 24" MIN EACH DIRECTION. THE MINIMUM DEPTH OF WALL OVER OPENING SHALL BE 1/4 TIMES THE SPAN OF THE OPENING OR 12 IN., WHICHEVER IS GREATER. FOOTINGS SHALL BEAR ON ADEQUATE SOILS AND SHALL BE CENTERED BELOW THE WALL OR COLUMN UNLESS NOTED OTHERWISE. THEY SHALL ALSO EXTEND BELOW THE SPECIFIED FROST DEPTH AT EXTERIOR FOOTINGS. ALL VOIDS BELOW FOOTINGS SHALL BE BACKFILLED WITH A LEAN 1,000 PSI MIN. CONCRETE FILL. PROVIDE CONT. 2X4 BEVELED KEY-WAY AT ALL CONT. WALL FOOTINGS. STAGGER ALL FOOTING CONSTRUCTION JOINTS 6' MIN. FROM WALL JOINTS. AT ALL JOINTS BETWEEN NEW AND EXISTING, CENTER WALL REINFORCING UNLESS SPECIFIED OTHERWISE. PROVIDE DRAINS AT THE BASE OF RETAINING WALLS AND BASEMENT WALLS UNLESS SPECIFIC APPROVAL TO ELIMINATE THE DRAIN IS PROVIDED BY THE BUILDING OFFICIAL. CONCRETE WALLS: CONCRETE WALLS NOT SPECIFICALLY NOTED IN THE PLANS SHALL BE REINFORCED AS FOLLOWS: REINFORCING STEEL SHALL BE FREE OF LOOSE, FLAKY RUST, SCALE, GREASE, OIL, DIRT AND ANY OTHER MATERIALS THAT MIGHT IMPAIR BOND. WHERE EPOXY COATED BARS ARE USED, LAP LENGTHS AND BEND LENGTHS SHALL BE MULTIPLIED BY A FACTOR OF 1.2. CLEAR AND ANCHORAGE AND PLACEMENT: ALL REINFORCEMENT BARS SHALL BE SECURELY ANCHORED TO THE FORMS AND SPACED FROM THEM AS FOLLOWS: FOR CONCRETE SURFACES NOT EXPOSED DIRECTLY TO THE GROUND OR WEATHER: 3/4" IN SLABS AND WALLS 1" IN JOISTS OR WAFFLE RIBS 1 1/2" IN BEAMS, PIERS AND COLUMNS FOR CONCRETE SURFACES EXPOSED TO THE WEATHER, 1 1/2" FOR CONCRETE SURFACES EXPOSED TO THE GROUND AFTER REMOVAL OF FORMS, 2" FOR CONCRETE SURFACES DEPOSITED AGAINST THE GROUND, 3" CONCRETE COVER TO REINFORCEMENT. FORMS AND SCREEDS FOR SUSPENDED CONCRETE SYSTEMS SHALL BE CAMBERED 1/4 IN. PER 10'-0" OF SPAN TO COMPENSATE FOR DEAD LOAD DEFLECTION. CONSTRUCTION AND CONTROL JOINTS: CONSTRUCTION JOINTS: CONSTRUCTION JOINTS NOT SHOWN ON PLANS SHALL BE MADE AND LOCATED AS TO LEAST IMPAIR THE STRENGTH OF THE STRUCTURE AND SHALL BE APPROVED BY THE ARCHITECT. ALL REINFORCING BARS SHALL RUN CONTINUOUS THROUGH JOINTS. CONSTRUCTION JOINTS SHALL HAVE A BEVELED KEY-WAY (1" MIN. DEPTH AND HEIGHT) AND SHALL BE LOCATED NO FURTHER THAN 1/30TH OF THE SLAB THICKNESS OR 125', WHICHEVER IS LESS. SEE SPECIFIC DETAILS FOR LARGER KEY-WAYS. CONTROL JOINTS: CONTROL JOINTS SHALL NOT BE SPACED MORE THAN 2*SLAB THICKNESS (IN INCHES) IN FT.: 4" SLAB = 8' MAX SPACING 5" SLAB = 10' MAX SPACING 6" SLAB = 12' MAX SPACING CONTROL JOINTS SHALL BE LOCATED IN SQUARES AS FAR AS POSSIBLE AND SHALL NOT CREATE CONCRETE WITH A LENGTH TO WIDTH RATIO GREATER THAN 1.25:1 CONTROL JOINTS SHALL BE 1/4 THE THICKNESS OF THE SLAB IN DEPTH AND SHALL BE CUT AT INTERIOR SLABS AND SHALL CUT OR CREATED WITH A 1/2" RADIUS JOINTER PER OWNER REQUIREMENTS. SPLICES AND LAPS: ALL SPLICES AND LAPS IN REINFORCING BARS SHALL BE PER THE TYPICAL REBAR LAP SPLICE SCHEDULE. WHERE LAPPED SPLICES IN COLUMN VERTICALS ARE USED, THE MINIMUM AMOUNT OF LAP SHALL BE 30 BAR DIAMETERS. SPLICES IN BAR WILL BE PERMITTED ONLY AT FLOOR LEVELS OR POINTS OF LATERAL SUPPORT. WHERE CHANGES IN THE CROSS SECTION OF THE COLUMN OCCUR, THE VERTICAL BARS SHALL BE OFFSET IN A REGION WHERE LATERAL SUPPORT IS PROVIDED. AT ALL OFFSETS, THE SLOPE OF THE INCLINED PORTION SHALL NOT BE MORE THAN 1 IN 6, AND IN THE CASE OF TIED COLUMNS, THE TIES SHALL BE SPACED THREE INCHES ON CENTERS FOR A DISTANCE OF ONE FOOT BELOW AND ABOVE THE POINT OF OFFSET. CONCRETE RETAINING WALLS SHALL NOT BE STRIPPED, BACKFILLED/LOADED UNTIL CONCRETE HAS REACHED THE SPECIFIED 7 DAY COMPRESSIVE STRENGTH. 1. 2. 3. A. B. C. 4. 5. 6. SHOP DRAWINGS/SUBMITTALS STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER SHOP DRAWINGS AND SHOP DRAWINGS ARE NOT ACCEPTABLE UNTIL REVIEWED AND STAMPED. ALL SUBMITTALS SHALL BE IN CONFORMANCE WITH THE SPECIFICATIONS. IF AN ALTERNATE IS PROPOSED, SUFFICIENT TIME TO REVIEW THE IMPLICATIONS OF THE CHANGE MUST BE ACCOUNTED FOR. UNLESS AN ALTERNATE CAN BE PROVEN TO MEET OR EXCEED THE SPECIFIED PRODUCT CAPACITIES/VALUE, IT SHALL NOT BE SUBMITTED FOR REVIEW. THE FOLLOWING SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW/APPROVAL PRIOR TO FABRICATION OR PLACEMENT OF MATERIALS: STRUCTURAL FILL MATERIAL SPECIFICATIONS CONCRETE MATERIAL SPECIFICATIONS AND MIX DESIGNS REINFORCING STEEL SHOP DRAWINGS THE CONTRACTOR IS TO REVIEW SHOP DRAWINGS AND VERIFY COORDINATION WITH CONTRACT DOCUMENTS AND SHALL SUBMIT ALL ITEMS IN A TIMELY MANNER. THE ENGINEER REVIEW IS TO VERIFY GENERAL CONFORMITY AND SHALL NOT BE CONSIDERED AN APPROVAL UNLESS STATED OTHERWISE. IT IS ANTICIPATED THAT THE SUBMITTALS WILL BE REVIEWED AND RESPONDED TO WITHIN (2) WEEKS OF RECEIPT. DRAWINGS MUST BE APPROVED AND ON-SITE BEFORE ANY WORK ASSOCIATED WITH THE ITEM COMMENCES. 1. 2. 3. 1. A. a. b. c. B. a. b. c. 2. 3. 4. 5. A. B. C. D. E. F. G. 1. A. a. b. c. B. a. b. c. 1. 2. POST-INSTALLED ANCHORING SYSTEMS: THE CONTRACTOR SHALL SUBMIT, FOR REVIEW AND APPROVAL, THE MANUFACTURER'S ICC EVALUATION REPORT FOR ALL ANCHOR SYSTEMS. THE CONTRACTOR MAY SUBMIT ICC EVALUATION REPORTS FOR ALTERNATE ANCHOR SYSTEMS. THE ALTERNATE SHALL PROVIDE CAPACITIES EQUAL TO OR GREATER THAN THOSE SPECIFIED. THE ALTERNATE METHOD SHALL BE APPROVED BY THE ENGINEER OF RECORD PRIOR TO SUBSTITUTION. FOLLOW ALL OF THE MANUFACTURER'S RECOMMENDATIONS AND ICC-ESR FOR ANCHOR INSTALLATIONS. UNLESS SPECIFIED OTHERWISE, ALL PRODUCTS SHALL BE DESIGNED TO ACCOMMODATE CRACKED CONCRETE CONDITIONS EPOXY ANCHORAGE: ACCEPTABLE MANUFACTURER'S (U.N.O. ON PLANS): CONCRETE ANCHORAGE: HILTI HIT HY 200 (ICC-ECR-3187). POWERS FASTENERS POWERS PE1000 + (ICC-ESR-2583). SIMPSON SET-XP (ICC-ESR-2508). MASONRY ANCHORAGE: HILTI HIT HY 200 (ICC-ESR-3187) FOR GROUT FILLED MASONRY APPLICATIONS. HILTI HIT HY 70 (ICC-ESR-3342) FOR HOLLOW MASONRY APPLICATIONS. SIMPSON SET (ICC-ESR-1772). INSTALL ANCHORS PER MANUFACTURER'S REQUIREMENTS. THESE REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO, HOLE PREPARATION, EPOXY PROPORTIONS AND QUANTITIES, INSTALLATION TEMPERATURE, AND CURE TIMES. REMOVE EXCESS EPOXY FROM SURFACE. ALLOW EPOXY TO CURE PER MANUFACTURER'S RECOMMENDATIONS. ANCHOR TESTING: CONTRACTOR TO SCHEDULE TESTING. CONTACT ENGINEER 48 HOURS PRIOR TO TESTING FOR OBSERVATION OF TESTS. EPOXY EMBEDDED ANCHORS TO BE FIELD TESTED TO ENSURE PROPER INSTALLATION & STRENGTH. PROVIDE A PULL-TEST ON 5% OF ALL EPOXY EMBEDDED ANCHORS BY AN INDEPENDENT, CERTIFIED AGENCY. ANCHORS SHALL BE LOADED TO A MINIMUM 1500 LBS IN TENSION (UNLESS NOTED OTHERWISE ON PLANS). ANCHORS DO NOT NEED TO BE PULLED TO FAILURE. IF AN ANCHOR DOES NOT MEET THE REQUIRED STRENGTH, ANCHORS ON BOTH SIDES SHALL BE TESTED. IF THESE ANCHORS DO NOT MEET THE REQUIRED STRENGTH, CONTINUE TESTING OF ALL ANCHORS IN IMMEDIATE AREA UNTIL PASSING VALUES ARE ACHIEVED. ALL ANCHORS THAT DO NOT MEET THE REQUIRED STRENGTH SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. TESTING COST TO BE PAID BY THE OWNER. IF ADDITIONAL RE-TESTING IS REQUIRED DUE TO ANCHORS NOT MEETING REQUIRED STRENGTHS, THE CONTRACTOR SHALL PAY THE COST OF THE RE-TESTING. MECHANICAL ANCHORS: ACCEPTABLE MANUFACTURER'S (U.N.O. ON PLANS): CONCRETE ANCHORAGE: HILTI KWIK BOLT TZ (ICC-ESR-1917). SIMPSON STRONG-BOLT (ICC-ESR-1771). POWERS POWER-STUD+SD1 (ICC-ESR-2818). MASONRY ANCHORAGE: HILTI KWIK BOLT 3 (ICC-ESR-1385) FOR GROUT FILLED MASONRY. SIMPSON WEDGE-ALL (ICC-ESR-1396) FOR GROUT FILLED MASONRY. POWERS POWER-STUD+SD1 (ICC-ESR-2966) FOR GROUT FILLED MASONRY. SCREW ANCHORS: ACCEPTABLE MANUFACTURER'S (U.N.O. ON PLANS): SIMPSON TITEN HD (ICC-ESR-2713) FOR CONCRETE AND GROUT FILLED MASONRY CONDITIONS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. A. B. 11. A. a. b. 12. A. a. b. c. STATEMENT OF SPECIAL INSPECTIONS THE OWNER/OWNER'S AGENT SHALL EMPLOY AN INDEPENDENT INSPECTOR OR INSPECTORS TO INSPECT THE ITEMS LISTED BELOW. THE SPECIAL INSPECTOR SHALL BE QUALIFIED TO INSPECT THE FOLLOWING ITEMS AND SHALL DEMONSTRATE HIS OR HER COMPETENCE TO THE SATISFACTION OF THE ENGINEER OF RECORD. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK FOR CONFORMANCE TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND THE ENGINEER. A FINAL SIGNED REPORT SHALL BE SUBMITTED STATING WHETHER THE WORK WAS IN CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. ALL SPECIAL INSPECTIONS SHALL BE BASED ON CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE AND THE APPLICABLE PRODUCT AND ASTM REQUIREMENTS. VERIFY CHAPTER 17 REQUIREMENTS FOR NON-STRUCTURAL ELEMENTS ARE MET. INSPECTIONS SHALL BE PERFORMED WITH AN APPROVED SET OF CONSTRUCTION DOCUMENTS, SHOP DRAWINGS ARE NOT TO BE USED IN LIEU OF THE APPROVED DOCUMENTS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MEET WITH THE SPECIAL INSPECTION AGENCY PRIOR TO STARTING THE PROJECT TO COORDINATE AN INSPECTION SCHEDULE. THE CONTRACTOR SHALL PROVIDE ADEQUATE NOTICE (AS DETERMINED IN THE PRE-CONSTRUCTION COORDINATION MEETING) BEFORE EACH STAGE OF SPECIAL INSPECTION IS TO OCCUR. TYPE AND FREQUENCY OF INSPECTIONS SHALL BE PER THE PROJECT SPECIFICATIONS. CONTINUOUS INSPECTION MEANS THAT THE INSPECTOR IS ON THE SITE OBSERVING THE WORK THAT REQUIRES THE INSPECTION. THE INSPECTOR IS TO BE PRESENT AT ALL TIMES WHEN WORK IS BEING DONE ON THAT PORTION OF THE PROJECT REQUIRING CONTINUOUS INSPECTION. PERIODIC INSPECTION MEANS THAT THE INSPECTION IS COMPLETED ON A PERIODIC BASIS PROVIDED THE MATERIALS, QUALIFICATIONS OF WELDING PROCEDURES AND WELDERS ARE VERIFIED PRIOR TO THE START OF WORK. PERIODIC INSPECTIONS ARE MADE OF WORK IN PROGRESS AND A VISUAL INSPECTION OF ALL WELDS IS MADE PRIOR TO COMPLETION. FABRICATED ITEMS: SPECIAL INSPECTION OF FABRICATED ITEMS (AS NOTED BELOW), SHALL BE PERFORMED IN ACCORDANCE WITH IBC SECTION 1704.2.5. SPECIAL INSPECTIONS SHALL OCCUR IN THE SHOP AND RECORDS SHALL BE ISSUED FOR REVIEW. IF THE SHOP IS REGISTERED AND APPROVED TO PERFORM SUCH WORK, A CERTIFICATE MAY BE PROVIDED SHOWING APPROVAL AND SEPARATE SPECIAL INSPECTIONS WILL NOT BE REQUIRED. WHEN THE STEEL PRODUCTS ARE PROVIDED, A STATEMENT SHALL BE ISSUED NOTING THAT CONFORMANCE WITH SPECIAL INSPECTION REQUIREMENTS HAS OCCURRED. WIND-RESISTING COMPONENTS: PERIODIC SPECIAL INSPECTION IS REQUIRED FOR FASTENING OF THE FOLLOWING SYSTEMS AND COMPONENTS NOT LISTED IN THE TABLES BELOW: ROOF COVERING, ROOF DECK AND ROOF FRAMING CONNECTIONS. EXTERIOR WALL COVERING AND WALL CONNECTIONS TO ROOF AND FLOOR DIAPHRAGMS AND FRAMING. THE TYPES OF WORK TO BE INSPECTED (IN ADDITION TO THE ITEMS NOTED ABOVE) ARE AS SHOWN IN THE FOLLOWING TABLES: SPECIAL INSPECTIONS CONCRETE (1705.3): CONCRETE CONSTRUCTION SHALL BE SPECIAL INSPECTED ACCORDING TO TABLE 1705.3 IN THE CONSTRUCTION DOCUMENTS. IN THE ABSENCE OF SUFFICIENT DATA OR DOCUMENTATION SHOWING CONFORMANCE TO QUALITY STANDARDS FOR CONCRETE MATERIALS, TESTING SHALL BE REQUIRED TO DETERMINE MATERIAL PROPERTIES UNDER THE DIRECTION OF THE BUILDING OFFICIAL ACCORDING TO CHAPTER 3 ACI 318. SEE THE ATTACHED TABLE. SOILS (1705.6): EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND PROCEDURE AND LOAD-BEARING REQUIREMENTS SHALL BE SPECIAL INSPECTED TO VERIFY COMPLIANCE WITH THE APPROVED SOILS REPORT AND TABLE 1705.6 IN THE CONSTRUCTION DOCUMENTS. WHERE TOTAL DEPTH OF CONTROLLED FILL IS 12" OR LESS, THE SPECIAL INSPECTOR SHALL VERIFY THAT THE IN-PLACE DRY DENSITY OF THE COMPACTED FILL IS NOT LESS THAN THE 90% OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT ACCORDING TO ASTM D 1557. SEE THE ATTACHED TABLE. POST-INSTALLED ANCHORS: SPECIAL INSPECTIONS SHALL BE PERFORMED ACCORDING TO THE REQUIREMENTS OF THE ICC EVALUATION REPORT, PER TABLE 1705.3 OF THE IBC AND THE ATTACHED TABLE. REQUIRED VERIFICATION AND INSPECTION OF POST-INSTALLED ADHESIVE ANCHORS VERIFICATION AND INSPECTION CONTINUOUS PERIODIC APPLICABLE THIS PROJECT (YES OR NO) 1.VERIFICATION AND INSPECTION OF ANCHORS POST- INSTALLED IN MASONRY MEMBERS.X -YES TABLE 1705.6 REQUIRED SPECIAL INSPECTION AND TESTING OF SOILS VERIFICATION AND INSPECTION CONTINUOUS PERIODIC APPLICABLE THIS PROJECT (YES OR NO) 1. 2. 3. 4. 5. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. PERFORM CLASSIFICATIONS AND TESTING OF COMPACTED FILL MATERIALS. VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESS DURING PLACEMENT OF COMPACTED FILL. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT THE SITE HAS BEEN PREPARED PROPERLY. - - - X -X - X X X YES YES YES YES YES a. b. FOR SI: 1 INCH = 25.4 MM WHERE APPLICABLE, SEE SECTION 1705.12, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK. VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARD a IBC REFERENCE APPLICABLE THIS PROJECT (YES OR NO) TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. - - - - - - - - - - - - - - - - - - - - - - - X X X X X X X X X X X X X X X X X INSPECT REINFORCEMENT, INCLUDING PRE-STRESSING TENDONS, AND VERIFY PLACEMENT. REINFORCING BAR WELDING: a. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706; b. INSPECTION SINGLE PASS FILLET WELDS > 5/16" c. INSPECT ALL OTHER WELDS. INSPECT ANCHORS CAST IN CONCRETE. INSPECT ANCHORS POST-Installed b: a. ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY INCLINED AND RESIST SUSTAINED TENSION LOADS. b. MECHANICAL AND ADHESIVE NOT DEFINED IN 4.a VERIFY USE OF REQUIRED DESIGN MIX. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. INSPECT CONCRETE AND SHOT-CRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. VERIFY UNDERSTANDING OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. INSPECTIONS OF PRE-STRESSED CONCRETE FOR: a. APPLICATION OF PRE-STRESSING FORCES; AND b. GROUTING OF BONDED PRE-STRESSING TENDONS. INSPECT ERECTION OF PRE-CAST CONCRETE MEMBERS. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBERS BEING FORMED. ACI 318 CH. 20, 25.2, 25.3, 26.6.1-26.6.3 1908.4 AWS D1.4 ACI 318:26.6.4 ACI 318: 17.8.2 ACI 318: 17.8.2.4 ACI 318: 17.8.2 ACI 318: CH. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3 ASTM C172, ASTM C31, ACI 318: 26.4, 26.12 1908.10 ACI 318: 26.5 1908.6, 1908.7, 1908.8 ACI 318: 26.5.3-26.5.5 1908.9 ACI 318: 26.10 ACI 318: 26.8 ACI 318: 26.11.2 ACI 318: 26.11.1.2(b) YES NO NO NO YES NO YES YES YES YES YES NO NO NO NO YES Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/11/24 513-6660-23080101 N/A 513-6660 SPECIAL INSPECTION AND TESTING NOTES AND TABLES KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S0.2 SLAB ON GRADE JOINT SPACING SCHEDULE SLAB THICKNESS MAX SPACING 4"8' 5"10' 6"12' 7"14' 1. 2. 3. 4. 5. 6. NOTES: SPACING IS IN ANY DIRECTION. JOINTS MAY BE SAW CUT OR WET TOOLED AT OWNER'S DISCRETION AND SHALL EXTEND 1/4" OF THE SLAB THICKNESS INTO THE SLAB. (VERIFY CUT OR TOOLED WITH ARCHITECT/OWNER PRIOR TO CONSTRUCTION. PROVIDE (2) #4 X 48" BARS CENTERED IN SLAB THICKNESS AT ALL DISCONTINUOUS JOINT LOCATIONS AND AT ALL RE-ENTRANT CORNERS. ALIGN CONTROL JOINTS WITH COLUMNS, OFF CORNERS OF WALLS, OFF STEPS IN SLABS, AS OCCURS. WHERE CONTROL JOINTS CREATE RECTANGULAR SECTIONS, THE LENGTH OF THE SECTION SHALL NOT EXCEED 1.5 TIES THE WIDTH. SLAB SHALL BE JOINTED SOON ENOUGH TO AVOID SHRINKAGE CRACKING BUT CONCRETE SHALL BE SET ENOUGH TO AVOID CHIPPING. TYPICAL RE-ENTRANT CORNER OR STEP IN SLAB FOUNDATION OR STEP IN SLAB END OF CONTROL JOINT #4 BARS AS NOTED SLAB JOINTS TYPICAL CONCRETE REBAR LAP AND BEND SCHEDULE BAR SIZE MIN. SPACING STANDARD 90° HOOK LENGTH TOP BARS OTHER BARS #3 2"4 1/2"21"16" #4 2 1/2"6"28"22" #5 3 1/4"7 1/2"35"27" #6 3 3/4"9"42"32" #7 4"10 1/2"61"47" #8 4"12"78"60" #9 4 1/4"13 1/2"105"76" 1. 2. 3. 4. 5. 6. LAP AND BEND NOTES: BAR SPACING IS CENTER TO CENTER. TOP BARS ARE HORIZONTAL BARS PLACED WITH 12" OR MORE OF NEW CONCRETE BELOW SPLICE. CONCRETE LAP LENGTHS ARE BASED ON ACI 318 WITH CLASS B LAP SPLICE. LAPS ARE FOR NORMAL WEIGHT CONCRETE WITH UNCOATED BARS. DESIGN BASED ON f'C OF 2,500 PSI WITH 1 1/2" MIN. CLEAR AND 60,000 PSI STEEL. SEE STRUCTURAL NOTES FOR REQUIRED CONCRETE STRENGTH AND REINFORCING REQUIREMENTS. SEE GENERAL STRUCTURAL NOTES FOR REQUIRED CONCRETE STRENGTH AND REINFORCING REQUIREMENTS. FOR EPOXY COATED BARS, BEND, HOOK AND LAP LENGTHS SHALL BE MULTIPLIED BY A FACTOR OF 1.3. a. b. c. d. e. FABRICATION NOTES: "db" = DIAMETER OF BAR MINIMUM BEND DIAMETER IS 4*db FOR UP TO #5 BAR AND 6*db FOR #6 THROUGH #8 BARS MINIMUM FINISHED BEND DIAMETER IS 8*db UP FOR #9 BARS THROUGH #11 BARS AND 10*db FOR #14 AND #18 BARS 6*db UP TO #5 BARS, 12*db AT #6 THROUGH #8 BARS ALL REINFORCING SHALL BE BENT COLD UNLESS NOTED OTHERWISE. MAXIMUM OFFSET STIRRUPS AND TIES STANDARD BENDS AND HOOKS 1 3 5 . 0 0 ° BEND PER NOTE b BEND PER NOTE b NOTE d 6 1 BEND PER NOTE c 4*db, 2 1/2" MIN. BEND PER NOTE c 12 * d b 6*db, 3" MIN. 1. 2. A. B. C. a. b. c. 3. 4. 5. STRUCTURAL FILL REQUIREMENTS: WHERE ROAD BASE IS SPECIFIED, IT SHALL MEET THE UDOT REQUIREMENTS FOR TYPE II. WHERE SPECIFIED PER PLAN, THE FOLLOWING STRUCTURAL FILL REQUIREMENTS SHALL BE MET: LIQUID LIMIT: 30 OR LESS. PLASTICITY INDEX: 10 OR LESS. GRADATION/PERCENT PASSING: 6-INCH/100% 3-INCH/80-100% NO. 200 SIEVE/10-30% MAXIMUM LIFT THICKNESS SHALL BE 8-INCHES, LOOSE. MINIMUM COMPACTION SHALL BE 95% PER ASTM D-1557. COMPACTION MOISTURE SHALL BE WITHIN 2% OF OPTIMUM. 1. 2. 3. 4. 5. 6. 7. 8. UTILITY LOCATE/BLUE STAKES INFORMATION: GO TO WWW.BLUESTAKES.ORG TO SUBMIT YOUR REQUEST ONLINE OR CALL 811, OPTION 1. PLEASE PROVIDE THE BEST CONTACT PHONE NUMBERS SO QUESTIONS AND CONCERNS CAN BE ANSWERED QUICKLY - THIS MAY HELP PREVENT DELAYS ON YOUR PROJECT. REQUEST ONLY THE AREA THAT IS NEEDED FOR THE EXCAVATION WORK BEING DONE. BE PREPARED TO ANSWER CLARIFYING QUESTIONS REGARDING YOUR EXCAVATION AREA. MEET ALTERNATIVE, ONLY IF NECESSARY - NOT AS A SUBSTITUTE FOR PREPARATION. WAIT THE TWO BUSINESS DAYS, THEN INSPECT THE SITE FOR PROPER MARKINGS. GO TO WWW.BLUESTAKES.ORG/POSITIVE-RESPONSE TO REVIEW ELECTRONIC POSITIVE RESPONSE FOR YOUR LOCATE REQUEST. DIG SAFELY! CONCRETE WALL SCHEDULE 1 MARK WALL THICKNESS MAX. HEIGHT NOTES VERT. REINF.HORIZ. REINF. CW1 SIZE SIZEMAX. SPACING MAX. SPACING 8"#4 10" O.C.#4 10" O.C.8'-0" ABOVE SLAB 2, 3 1. 2. 3. NOTES: CONCRETE AND REINFORCING REQUIREMENTS PER GENERAL STRUCTURAL NOTES. CENTER STEEL IN WALL. LOCATE HORIZONTAL BARS 2" FROM TOP OF WALL, 3" FROM FOOTING AND SPACED EVENLY IN WALL HEIGHT AND AT MAXIMUM SPACING OF 16". WALL MAY OR MAY NOT BE ICF. MARK1 LENGTH WIDTH DEPTH NO. OR BARS MIN. BAR SIZE SPACING LENGTH NOTES PEDESTAL REINFORCING AT EACH COLUMN TRANSVERSE REINFORCEMENTLONGITUDINAL REINFORCEMENT NO. OR BARS MIN.BAR SIZE SPACING LENGTH FC3.0 CONT.36"12"5 #4 7.5"- - -N/A #4 48"30"- - - 1. 2. 3. 4. 5. 6. 7. 8. 9. FOOTING NOTES: FSX SIGNIFIES SQUARE FOOTING. FCX SIGNIFIES CONTINUOUS FOOTING. FRX SIGNIFIES RECTANGULAR FOOTING. PROVIDE 60 KSI REINFORCING WITH CLEAR COVER, LAPS, BENDS, ETC. PER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. EXTEND CONT. REINFORCING THROUGH ALL INTERSECTING FOOTINGS. CENTER FOOTING UNDER WALL, UNLESS NOTED OTHERWISE. THICKENED SLAB FOOTING. PROVIDE FOOTING REINFORCING TOP AND BOTTOM. CONCRETE COLUMN/PEDESTAL PER PLAN. FOR TRANSVERSE REINFORCING, PROVIDE STANDARD HOOK DOWN AT TOE EDGE OF FOOTING INSIDE BUILDING AND MAINTAIN 3" CLEAR AT EACH FACE OF FOOTING. LOCATE 3" FROM EACH EDGE AND AT SPACING NOTED. WALL REINFORCING PER SCHEDULE SHALL BE CENTERED IN WALL WITH STANDARD HOOK ALTERNATING DIRECTIONS INTO FOOTING. ADDITIONAL RETAINING WALL REINFORCING AT BACK WALL SHALL BE PER DETAIL. EXTEND ADDITIONAL RETAINING WALL BARS DOWN TO 3" FROM BOTTOM OF FOOTING, LAP BARS 24 BACK INTO FOOTING AND EXTEND UP INTO WALL ABOVE FOOTING. LENGTH SHOWN INTO PAGE FOOTING SCHEDULE 1 THRU 4 WIDTH DE P T H LONGITUDINAL BARS TRANSVERSE BARS VERTICAL DOWELS WITH STANDARD HOOK INTO FOOTING REINFORCING TIES FC6.0 CONT.72"12"9 #4 7.3"- - -N/A #4 8"- - -- - - TOP BARS WHERE SPECIFIED TYPICAL STEMWALL/COLUMN/PEDESTAL REINFORCING EACH FACE OR AT COLUMN/PEDESTAL, WHERE SPECIFIED 8, 9 12 " M I N . D E E P 0' - 8" CL1 CONCRETE LINTEL SCHEDULE a,b,c,d BOTTOM BARS CL1 TOP BARS (2) #4 MARK STIRRUPS (2) #4 a. b. c. d. NOTES : PROVIDE (2) #4 BARS MIN. AT 2" FROM FACE, ALL AROUND ALL WINDOWS AND DOORS. EXTEND TOP AND BOTTOM REINFORCING 24" MIN. EACH SIDE OF OPENING, OR PROVIDE LAP LENGTH BEND AROUND CORNERS, TYP. PROVIDE (2) OF THE SPECIFIED WALL REINFORCING BARS FULL HEIGHT, BOTTOM TO TOP OF WALL AT EACH SIDE OF EACH OPENING, 2" FROM FACE OF OPENING. PROVIDE STANDARD HOOK DOWN AT ALL HORIZONTAL WALL REINFORCING BARS EACH SIDE OF EACH OPENING. #3 @ 8" O.C. TOP BARS, TYP. BOTTOM BARS STIRRUPS 0' - 6" STIRRUPS SHALL BE Z-SHAPED Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/11/24 513-6660-23080101 N/A 513-6660 TYPICAL DETAILS AND SCHEDULES KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S0.3 3/4" = 1'-0"1 SLB ON GRD. JNT. SPC. SCHED. 1" = 1'-0"2 CONCRETE LAP AND BEND SCHEDULE 3/4" = 1'-0"3 BLUE STAKES NOTE 3/4" = 1'-0"4 CONC. WALL SCHED. 3/4" = 1'-0"5 FOOTING. SCHEDULE 3/4" = 1'-0"6 LINTEL SCHEDULE S2.0 FRONT S2.0 S2.0 S2.0LE F T RI G H T BACK 1 S3.0 1 S3.1 4' - 6" 4' - 0" 4' - 0"0' - 0" 6' - 0" -0' - 1 1/2" -0' - 1 1/2"0' - 0" 4' - 0" 4' - 0"5' - 0" 0' - 0" 3' - 0"3' - 0" -0' - 1 1/2" 0' - 0" -0' - 1 1/2" BLEND TO EXISTING BLEND TO EXISTING WITH 2H:1V MAX SLOPE 6' - 0" 6' - 0 " 10' - 0" N 0' - 0" E 0' - 0" EL -1' - 0" 6 10' - 0" 8' - 0 " 8' - 8"6' - 8 " 1 S3.0 1 S3.1 6' - 0 " 0' - 6 " 0' - 6" FC3.0_12" FC3.0_12" FC3.0_12" -2' - 0" -2' - 0" CW1 CW1 CW1CW1 CW1 CW1 SEE DETAIL FOR WALL REINFORCING SLAB PER SECTION AND DETAILS FC6.0_6' X12" RETAINING FOOTING 6' - 0" 6' - 8" A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. GENERAL FOUNDATION NOTES: DIMENSIONS AT GRID LINES ARE TO FACE OF CONCRETE FOUNDATION, FACE OF SHEATHING, CENTERLINES OR FACES OF WALLS, AS NOTED PER PLAN. CONTRACTOR TO VERIFY AND COORDINATE ALL DIMENSIONS AND CONDITIONS AND NOTIFY E.O.R. OF ANY DISCREPANCIES OR CONCERNS. CONTRACTOR TO VERIFY GEOTECHNICAL REQUIREMENTS AND UNDERSTOOD AND ARE MET. ALL SOILS SHALL BE COMPACTION TESTED AND APPROVED FOR PROPER GRADATION BEFORE ANY CONCRETE IS PLACED. SEE DETAIL 3, THIS SHEET FOR GEOTECHNICAL REQUIREMENTS. THE EXTERIOR FACE OF THE FOUNDATION WALL SHALL BE DAMP-PROOFED TO GRADE. SEE THE GENERAL STRUCTURAL NOTES, REQUIREMENTS AND TYPICAL DETAILS ON SHEETS S0.1, S0.2, AND S0.3 AND SPECIFICATIONS FOR CONCRETE, REINFORCING AND CLEAR COVER REQUIREMENTS. ALL REINFORCING SHALL BE TIED IN PLACE OR SET ON CHAIRS/DOBIES PRIOR TO CONCRETE PLACEMENT. CONCRETE SLABS AND REINFORCING SHALL BE AS NOTED PER DETAILS. FSX SIGNIFIES SQUARE FOOTING PER SCHEDULE, THIS SHEET. FCX SIGNIFIES CONTINUES FOOTING PER SCHEDULE, THIS SHEET. FRX SIGNIFIES RECTANGULAR FOOTING, THIS SHEET. CWX SIGNIFIES CONCRETE WALL PER SCHEDULE, THIS SHEET. SLABS SHALL BE CUT OUR JOINTED AS NOTED IN THE SCHEDULE, SHEET S0.3. CONCRETE MIX SHALL BE PER THE SPECIFICATIONS . ALL WALLS AND THE LID/ROOF SHALL HAVE XYPEX C-1000 CONCRETE WATERPROOFING INCLUDED IN THE MIX AT A RATE OF 2% BY WEIGHT OF CEMENT. A SEPARATE MIX DESIGN IS REQUIRED. THE CONTRACTOR IS TO INVESTIGATE THE USE OF THE XYPEX PRODUCTS PRIOR TO BIDDING AND COORDINATE WITH THEIR RESPECTIVE CONCRETE SUPPLIERS. ALL EXPOSED EXTERIOR BUILDING, WALL, SOFFIT, FASCIA, ROOF AND RETAINING WALL SURFACES SHALL BE GROUND/STONED OFF TO A SMOOTH SURFACE, THE TIE HOLES SHALL BE PACKED WITH XYPEX PATCH AND PLUG AND THE ENTIRE SURFACE SHALL BE FINISHED WITH XYPEX MEGAMIX I WITH A RUBBER OR FOAM TROWEL. ALL CONCRETE EDGES SHALL HAVE 1" CHAMFER FORMED IN PLACE. THIS INCLUDES ALL VERTICAL CORNERS, ALL DOOR OPENINGS, IN AND OUT, ALL EDGES AT THE LID/ROOF, ALL EDGES/CORNERS OF THE RETAINING WALLS, ETC. CONCRETE FLATWORK OUTSIDE THE BUILDING SHALL BE TREATED WITH WEATHERWORKER J29A 100% SOLIDS. NOTE: GRILLS ON DOOR AND IN VENTS ON WALLS NOT SHOWN. UNDISTURBED, NATIVE SOIL 2' - 0" 2' - 0 " 1' - 0 " , M I N . TYPICAL SLABTYPICAL FOOTING TYPICAL WALL NATIVE SOILS SHALL BE REMOVED AND REPLACED TO THE DEPTH SHOWN AT A MINIMUM AND REPLACED WITH STRUCTURAL FILL PER SHEET S0.3. TYPE II ROADBASE SHALL BE PLACED PER THE SECTIONS ON SHEET S3.0 AND S3.1 AND THE DETAILS ON SHEET S4.0. SITE CLEARING NOTE: ALL VEGETATION AND ORGANIC MATTER (NO LESS THAN 6") SHALL BE REMOVED FROM BELOW FOOTINGS, SLABS AND DRIVEWAYS WITH THE SOILS AT THE BOTTOM OF EXCAVATIONS SCARIFIED TO NO LESS THAN 6", MOISTURE PROCESSED AND RE-COMPACTED AS NOTED BELOW. 1 S3.0 1 S3.1 Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/11/24 513-6660-23080101 N/A 513-6660 CHLORINATION BUILDING SITE AND PLAN VIEWS KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S1.0 1/4" = 1'-0"1 SITE AND GRADING 1/4" = 1'-0"2 MAIN FLOOR 5 RENDERING 3/4" = 1'-0"4 OVER-EX REQUIREMENTS 1. 2. 3. 4. 5. 6. FOUNDATION KEYNOTES: PROVIDE 4" PVC HEAVY WALL PERFORATED PIPE AND FABRIC WRAPPED GRAVEL DRAIN TO DAYLIGHT NEAR EDGE OF ROAD WITH 1/4" PER FOOT MIN. SLOPE. CAP THE HIGH END AND GLUE ALL FITTINGS. CONTRACTOR TO ANTICIPATE AND ACCOUNT FOR UP TO 40' OF PIPE AND ALL FITTINGS NECESSARY INSTALL THE SYSTEM. SEE THE DRAIN SYSTEM DETAIL FOR ADDITIONAL INFORMATION. ONE FULL 10-WHEELER TRUCK LOAD OF 3/8" TO 3/4" PEA GRAVEL SHALL BE SPREAD ON THE LOW SIDE OF THE BUILDING, LEFT SIDE, FRONT AND RIGHT SIDE. ALL EXCESS PEA GRAVEL SHALL BE SPREAD ON THE ROADWAY. 16" SQUARE X 16" DEEP CONCRETE COLLECTION BOX WITH STEEL GRATE FROM HD SUPPLY/WHITE CAP. PROVIDE SOLID 4" PVC SEWER OUT BACK OF BUILDING AND TIE INTO PERFORATED LINE WITH APPROPRIATE FITTINGS. DRILL/SLEEVE AS REQUIRED FOR CONNECTIONS AND PROVIDE BUTYL RUBBER SEAL AND NON-SHRINK GROUT TO ENSURE TIGHT CONNECTIONS BOX TO PIPE AND THROUGH WALL. SHAPE INSIDE OF BOX WITH NON-SHRINK GROUT TO ENSURE FLOW OUT AND PROVIDE DAMP- PROOFING ON INSIDE FACE OF BOX. PROVIDE EXPANSION JOINT AND ELASTOMERIC SEALER IN SLAB ALL AROUND BOX. IN AND OUT FLOW WATER LINES AND PENETRATIONS PER BOWEN AND COLLINS. PROVIDE 1" MIN. FOAM SLEEVE AROUND PIPE AND PROVIDE ELASTOMERIC SEALANT AFTER INSTALLATION. THE ENTIRE FLOOR SURFACE SHALL BE CLEANED PRIMED AND PAINTED WITH EPOXY PAINT WITH SILICA SAND OR CRUSHED WALNUT FOR TRACTION. DOSAGE SHALL BE PER MANUFACTURER RECOMMENDATIONS. SEE SHEET G0.2 FOR FINE GRADING AND SEEDING REQUIREMENTS AT ALL DISTURBED NON-ROAD AREAS. 1/4" = 1'-0"3 ROOF 1 1 2 1. A. B. C. MATERIAL NOTES: THE CONTRACTOR SHALL PROVIDE THE FOLLOWING FOR FOUNDATION CREATION AND SHALL SPREAD THE REMAINING ON THE ROADWAY AND THROUGHOUT THE SITE TO ENSURE ADEQUATE SLOPE AWAY AND THAT THE DETAIL REQUIREMENTS ARE MET: 50 CUBIC YARDS OF STRUCTURAL FILL PER SHEET S0.3. 10 CUBIC YARDS OF TYPE II ROADBASE. 10 CUBIC YARDS OF 3/8" TO 3/4" PEA GRAVEL. 3 4 1. A. B. C. D. 2. 3. 4. STRUCTURAL OBSERVATIONS THE ENGINEER OF RECORD SHALL BE PRESENT DURING THE FOLLOWING EVENTS: WHEN THE EXACT BUILDING LOCATION, SEPTIC SYSTEM, WATER SYSTEM AND TENT PADS ARE LAID OUT. AFTER EXCAVATION OF THE BUILDING. PRIOR TO GRAVEL AND/OR CONCRETE PLACEMENT AT EACH STAGE. TO OBSERVE THE FINAL STAGES OF EACH PART OF THE PROJECT. AT SUBSTANTIAL COMPLETION AND FOR FINAL OBSERVATIONS. THE CONTRACTOR SHALL PROVIDE 48 HOUR NOTICE BEFORE A GIVEN EVENT TO ALLOW FOR SCHEDULING. STRUCTURAL OBSERVATIONS DO NOT TAKE THE PLACE OF SPECIAL INSPECTIONS OR JURISDICTIONAL INSPECTIONS. WORK SHALL NOT CONTINUE AND NO ITEMS SHALL BE COVERED UNTIL OBSERVATION HAVE OCCURRED. MAIN FLOOR 0' - 0" ROOF 8' - 0" TOP OF FOOTING-2' - 0" ROOF LOW7' - 0" 1 S3.0 3' - 0 " , F R O S T D E P T H 4' - 0" 0' - 0" S2.1 1 MAIN FLOOR 0' - 0" ROOF 8' - 0" TOP OF FOOTING -2' - 0" ROOF LOW 7' - 0" 1 S3.1 5 S4.0 S2.1 2 TYP. 0' - 1 0 3 / 4 " 3' - 6" 1' - 5 " MAIN FLOOR0' - 0" ROOF 8' - 0" TOP OF FOOTING-2' - 0" ROOF LOW7' - 0" 1 S3.0 S4.0 5 MAIN FLOOR0' - 0" ROOF 8' - 0" TOP OF FOOTING-2' - 0" ROOF LOW7' - 0" 1 S3.1 5 S4.0 S2.1 2 TYP. Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/12/24 513-6660-23080101 N/A 513-6660 ELEVATIONS KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S2.0 1/2" = 1'-0"1 FRONT 1/2" = 1'-0"2 RIGHT 1/2" = 1'-0"3 BACK 1/2" = 1'-0"4 LEFT MAIN FLOOR 0' - 0" 1' - 0 " THIS SIDE SHALL HAVE LOCKING PINS TOP AND BOTTOM FOR FIXITY. DOOR MUST BE ABLE TO OPEN FULLY AFTER PINS ARE RETRACTED. ROOF LOW 7' - 0" 1' - 0" 1' - 0 " 0' - 5 3/4" 0' - 2 1/4" 0' - 1 3/4" 0' - 2 " 0' - 1" HOLD FRAME BACK FROM OUTSIDE FACE OF WALL AS SHOWN. PROVIDE ELASTOMERIC SEALANT INSIDE AND OUT. HOLLOW METAL DOOR FRAMES. ANCHOR AND GROUT PER MANUFACTURER RECOMMENDATIONS. PAINT TO MATCH DOORS. Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/13/24 513-6660-23080101 N/A 513-6660 DOOR AND VENT DETAILS KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S2.1 3/4" = 1'-0"1 DOOR DETAIL 1. 2. 3. 4. 5. A. B. C. D. E. F. G. H. 6. A. DOOR AND GRILL NOTES: ALL ITEMS TO BE PROVIDED AND INSTALLED BY CONTRACTOR U.N.O. CONTRACTOR TO VERIFY ALL ROUGH OPENINGS FOR DOORS PROPOSED WITH MANUFACTURER RECOMMENDATIONS. DOORS ORDERED MUST FIT OPENINGS. HEADS, JAMB AND THRESHOLD PER SPECIFICATIONS. PUNCH AND DIMPLE HOLLOW METAL FRAMES POST-INSTALLED ANCHORED PER MANUFACTURER RECOMMENDATIONS. SEE DETAIL 3, THIS SHEET FOR GEOMETRY. DOOR INFORMATION: HOLLOW METAL DOOR - (GALVANNEALED A60) DOOR CLOSERS (EACH DOOR) SHALL BE PER NORTON 8501 (ITEM CODE NOR0008). DOOR STOP AND HOLDER (LEFT DOOR) SHALL BE ROCKWOOD 472,473 SATIN CHROME (US26D). RIGHT DOOR SHALL HAVE A ROCKWOOD 460 KICK DOWN STOP.. 12X12 SIGHT PROOF VENT WITH BUG SCREEN, LOCATED LOW, PER MANUFACTURERS RECOMMENDATIONS. VENT IN DOOR MAY BE ALUMINUM. DRILLED FOR DEADBOLT AND LEVER LOCKSET. THRESHOLD, SWEEP AND WEATHER STRIPPING PER SPECIFICATIONS DOOR ROUGH OPENING IN CONCRETE MUST BE PLUMB, LEVEL AND SQUARE AND MEASURE TO FIT METAL BUCK. DOOR SHALL BE EVERGREEN TO MATCH THE EXISTING ON-SITE BUILDING ROOFS. PROVIDE SAMPLES FOR APPROVAL. WALL VENT INFORMATION: WALL VENT MAY BE ALUMINUM OR GALVANIZED AND SHALL BE PAINTED TO MATCH THE DOORS. VENT SHALL BE ANCHORED IN PLACE AND THEN SHALL HAVE ELASTOMERIC SEALANT INSTALLED ON THE INSIDE. 1/2" = 1'-0"2 TYPICAL VENT GRATE 3/4" = 1'-0"3 HOLLOW METAL DOOR FRAMES 1. VIRGIN RIVER FM SUPPLIED ITEMS INSTALLED BY CONTRACTOR: DOOR DEAD BOLT AND HANDLES. MAIN FLOOR0' - 0" ROOF8' - 0" TOP OF FOOTING -2' - 0" ROOF LOW 7' - 0" 0' - 2 " 0' - 3" 0' - 3" 0' - 6" 0' - 3 1 / 4 " 0' - 3 7/8" 0' - 4 1/8" 0' - 1 7/8" 1' - 0 " 6' - 0 " 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. KEYNOTES: STRUCTURAL FILL PER PLAN. TYPE II ROADBASE BELOW SLAB. SEE DETAIL 1/S4.0 FOR SLAB AND SLAB TO WALL CONNECTIONS. FOOTING PER SCHEDULE. WALL PER PLAN AND SCHEDULE. TURN DOWN BAR AND TOE SIDE OF FOOTING. PROVIDE ADDITIONAL VERTICAL BARS AT FACE OF WALL PER RETAINING WALL SECTION AND DETAIL ON SHEET S4.0. 4" PERFORATED PIPE AND LEACH ROCK GRAVEL DRAIN WRAPPED IN MIRAFI 140N OR APPROVED EQUIVALENT. SEE PLAN FOR LOCATION, EXTENT AND ROUTE. CARLISLE MIRA-DRAIN 6000/3200 INSTALLED AND ANCHORED TO WALL PER MANUFACTURER INSTRUCTIONS AFTER WALL IS DAMP-PROOFED. COMPACT NATIVE SOIL BACK INTO PLACE BEHIND THE WALL. EXTEND VERT. BARS TO PROVIDE LAP LENGTH BENDS INTO SLAB OR PROVIDE DOWELS WITH LAP LENGTH BENDS BOTH INTO SLAB AND INTO WALL. PROVIDE LINTEL PER DETAIL, SHEET S0.3 AND VERTICAL #4 @ 10" O.C. @ 10" O.C. WITH LAP LENGTH BENDS INTO THE SLAB. SEE SHEET S2.1 FOR DOOR DETAILS. #4 BARS @ 10" O.C. EACH DIRECTION, TOP AND BOTTOM. PROVIDE FULL LAP LENGTH BENDS BACK INTO THE SLAB TO AND BOTTOM. 1 2 3 4 5 6 7 81' - 0" 1' - 0 " 9 10 1' - 11 7/8" S4.0 2 AT ALL EXTERIOR SLABS DOWEL EXTERIOR SLAB TO WALL SIMILAR TO DETAIL 1/S4.0 WITH EXPANSION JOINT AND ELASTOMERIC SEALANT. S4.0 3 AT ALL EXTERIOR SLABS 0' - 7 7/8" 0' - 8 1/8" 0' - 1 0 " 11 12 13S4.0 6 TYP., ALL AROUND Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/12/24 513-6660-23080101 N/A 513-6660 SECTION FRONT TO BACK KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S3.0 3/4" = 1'-0"1 SECTION FRONT TO BACK MAIN FLOOR0' - 0" ROOF8' - 0" TOP OF FOOTING -2' - 0" ROOF LOW 7' - 0" 1 S3.0 S4.0 1 AT ALL EXTERIOR SLABS S4.0 5 S4.0 3 AT ALL EXTERIOR SLABS DOWEL EXTERIOR SLAB TO WALL SIMILAR TO DETAIL 1/S4.0 WITH EXPANSION JOINT AND ELASTOMERIC SEALANT. Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/13/24 513-6660-23080101 N/A 513-6660 SECTION SIDE TO SIDE KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S3.1 3/4" = 1'-0"1 SECTION SIDE TO SIDE NOTE: SEE SHEET S3.0 FOR WALL AND SLAB REINFORCING DETAILS. COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REQUIREMENTS. FOOTING AND REINFORCING PER PLAN WET SET DOWELS AND ALTERNATE BEND DIRECTION. WALL AND REINFORCING PER PLAN FINAL GRADING TO PROVIDE SLOPE AWAY FROM BUILDING - SEE SITE PLAN AND GENERAL NOTES (CONCRETE OR GRAVEL) PROVIDE STRUCTURAL FILL, APPROVED BY GEOTECHNICAL ENGINEER, BELOW SLAB. DO NOT USE PEA GRAVEL TO FILL THE VOID. 1/2" EXPANSION JOINT AT FACE OF WALL - INSTALL ELASTOMERIC SEALANT 28 DAYS AFTER SLAB PLACEMENT. CLEAN AND PROVIDE DAMPPROOFING AT WALL AND ON TOP OF FOOTING. PUDDLE IN CORNER 5" S L A B #4 X 30" DOWEL EMBEDDED 6" INTO WALL AT 22 1/2° DOWN ANGLE 0' - 6 " TYPE II ROADBASE BELOW SLAB #4 BARS AT 18" O.C., EACH WAY 3" FROM BOTTOM OF SLAB WIDTH PER PLAN 1_ 4 " PER FOOT SLOPE AWAY FROM BUILDING 6" 1. 2. 3. 4. 5. KEYNOTES: 6" THICK CONCRETE SLAB WITH THICKENED EDGE AND #3 REBAR @ 18: O.C. CENTERED IN SLAB THICKNESS WITH TURNED DOWN HOOK EXTENDING TO LOWER BARS. PROVIDE 1 1/2" LBS/CUBIC YARD FIBER MESH. TYPE II ROADBASE COMPACTED TO 95% PER ASTM D-1557. IMPORTED STRUCTURAL FILL. PROVIDE 3" OF 3/8" TO 3/4" WASHED PEA GRAVEL AROUND BUILDING AND SIDEWALKS (FRONT, RIGHT AND LEFT SIDES) EXTENDING 6' BEYOND CONCRETE. (2) #4 CONT. BOTTOM AT THICKENED EDGE. 1. 2. 3. NOTES: PROVIDE FULL LAP LENGTH BENDS AT ALL CORNERS, FULL LAPS AT SPLICES AND ALTERNATE SPLICES PER BAR. PROVIDE SEALER/HARDENER PER SPECIFICATIONS AFTER 28 DAYS. PROVIDE A MODERATE BROOM FINISH AT THE SURFACE AND 1/2" RADIUS AT ALL EDGES. 1' - 0" 1' - 0 " WIDTH PER PLAN 1 2 3 4 5 COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REQUIREMENTS. FOOTING AND REINFORCING PER PLAN WET SET DOWELS AND ALTERNATE BEND DIRECTION. EXTEND DOWELS ONE PIECE TO ALLOW FOR LAP LENGTH BEND BACK INTO SLAB. ALTERNATELY, PROVIDE STANDARD DOWELS AND WET-SET LAP LENGTH BARS TO TOP OF FOOTING. WALL AND REINFORCING PER PLAN FINAL GRADING TO PROVIDE SLOPE AWAY FROM BUILDING - SEE SITE PLAN AND GENERAL NOTES EXTEND SLAB REINFORCING TO FACE OF THICKENED DEE, BENT DOWN WITH CONTINUOUS BAR ALONG FACE OF SLAB. PROVIDE STRUCTURAL FILL, APPROVED BY GEOTECHNICAL ENGINEER, BELOW SLAB. DO NOT USE PEA GRAVEL TO FILL THE VOID. 5" S L A B WALL BEYOND 0' - 6 " 0' - 6 " SEE DETAIL 1, THIS SHEET FOR SLAB REINFORCING. MAIN FLOOR 0' - 0" TOP OF FOOTING-2' - 0" 1' - 0 " 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. KEYNOTES: STRUCTURAL FILL PER PLAN. TYPE II ROADBASE BELOW SLAB. SEE DETAIL 1/S4.0 FOR SLAB AND SLAB TO WALL CONNECTIONS. FOOTING PER SCHEDULE. RETAINING WALL IS TO BE POURED INTEGRAL WITH BACK WALL OF BUILDING. #4 TOP BARS @ 8" O.C. TO LAP WITH VERTICAL WALL BARS. TURN DOWN BAR AT TOE SIDE OF FOOTING. #4 VERT BARS AT 8" FROM FOOTING WITH BEND SHOWN. SEE DETAIL 5, THIS SHEET. #4 HORIZONTAL BARS @ 12" O.C. WITH BENDS AT END OF WALL AND LAP LENGTH BEND BACK INTO BUILDING. SEE DETAIL 5, THIS SHEET. #4 CONT. BARS IN FOOTING AT 8" O.C. 3 1/2" WIDE X 1 1/2" DEEP KEYWAY. 4" PERFORATED PIPE AND LEACH ROCK GRAVEL DRAIN WRAPPED IN MIRAFI 140N OR APPROVED EQUIVALENT. SEE PLAN FOR LOCATION, EXTENT AND ROUTE. CARLISLE MIRA-DRAIN 6000/3200 INSTALLED AND ANCHORED TO WALL PER MANUFACTURER INSTRUCTIONS AFTER WALL IS DAMP-PROOFED. 1 4 5 7 111' - 0" 1' - 0 " 12 5 S4.0 4' - 0" 0' - 3 1 / 8 " 0' - 2 1/8" 2' - 0"0' - 2" 0' - 2 " 0' - 6" 0' - 2 3/4" 2 3 6 8 10 6 9 MAIN FLOOR0' - 0" TOP OF FOOTING -2' - 0" #4 VERT, BARS @ 8" O.C. STARTING 2" FROM FACE #4 HORIZONTAL BAR @ 12" O.C. WITH BENT LAP AT TOP BAR AND LAP LENGTH BEND INTO BACK WALL OF BUILDING 0' - 8 3 / 8 " FOOTING PER PLAN0' - 6" 4' - 0" 0' - 2 " FACE OF BUILDING4 S4.0 TYP, ALL AROUND ROOF8' - 0" 4" TO DRIP N O T C H Release Date: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 C E D A R C I T Y , U T A H 8 4 7 2 1 ( 4 3 5 ) 7 0 4 - 4 4 0 5 P r o j e c t f o r : Ma r k Da t e De s c r i p t i o n Project Number: Plan Series: Property Number: Sheet Title: Sheet: 01/12/24 513-6660-23080101 N/A 513-6660 DETAILS KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T (5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T S4.0 3/4" = 1'-0"1 TYPICAL EXTERIOR WALL - TALL FOUNDATION WALL 3/4" = 1'-0"3 EDGE OF SIDEWALK DETAIL 3/4" = 1'-0"2 SLAB AT WALL AT DOORWAYS 3/4" = 1'-0"4 RETAINING WALL DETAIL 3/4" = 1'-0"5 RETAINING WALL REINFORCING SECTION 3/4" = 1'-0"6 EDGE OF ROOF DETAIL NOTE: REINFORCING NOT SHOWN FOR CLARITY. PROVIDE 1" X 1/2" TALL SIKA WATERSTOP AT WALL TO ROOF SLAB INTERFACE. PROVIDE 1" WIDE X 1" DEEP FORMED NOTCH ALL AROUND ROOF STRUCTURE. PROVIDE 1" X 45° CHAMFER AT ALL EDGES AROUND ROOF/SLAB. Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 CAMP IMPROVEMENTS SITE PLAN C1.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 CHLORINE BUILDING SITE PLAN C1.1 · · · · Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 GENERAL CIVIL NOTES C1.2 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 GENERAL CIVIL DETAILS - 1 C2.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 MECHANICAL PLAN M1.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 CHLORINE DOSING PROCESS SYSTEM SCHEMATIC M1.1 · · · Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 PIPE MATERIAL SCHEDULE M2.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 GENERAL MECHANICAL DETAILS - 1 M2.1 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : 02 - 1 3 - 2 4 GENERAL MECHANICAL DETAILS - 2 M2.2 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 ELECTRICAL SYMBOLS AND NOTES E1.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 ELECTRICAL CHLORINATION BUILDING PLAN VIEW E2.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 ELECTRICAL RESTROOM AND CENTRAL SHOWER PLAN VIEW E2.1 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 ELECTRICAL CONTROL DIAGRAMS E3.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 PV SYSTEM WIRING DIAGRAMS E4.0 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 ELECTRICAL CONTROLS WIRING DIAGRAMS E4.1 Sheet Title: Sheet: CD C O N S U L T I N G EN G I N E E R S , I N C . 23 9 0 W E S T H W Y 5 6 , S T E 2 CE D A R C I T Y , U T A H 8 4 7 2 1 (4 3 5 ) 7 0 4 - 4 4 0 5 5 FEB 2024 KO L O B D E E R H A V E N R C M P CH L O R I N A T I O N P R O J E C T ( 5 1 3 - 6 6 6 0 - 2 3 0 8 0 1 0 1 ) KO L O B T E R R A C E , W A S H I N G T O N C O U N T Y , U T 513-6660-23080101 N/A 513-6660 Property Number: Plan Series: Project Number: Release Date: Pr o j e c t f o r : LICENSED P R O F E S S IONAL E N G I N E ER STATE O F U T A H No . 8 8 5 2 8 6 0 - 2 2 0 2 SH A N E C U R T I S CA V A N A U G H 02 - 1 3 - 2 4 GENERAL ELECTRICAL DETAILS E5.0