Loading...
HomeMy WebLinkAboutDERR-2025-004851IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION OVERFILL OPERABILITY PV VENT CAP SPILL BUCKET TEST STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 6/26/2025 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 6/26/2025 Order Number: 2381149 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN 47167/9447 965 NORTH BECK ST State ID 4002031 SALT LAKE CITY, UT 84103 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2381149 Date: 6/26/2025 Site Name/ID: 7-ELEVEN 47167/9447 / 47167/9447 Address: 965 NORTH BECK ST State ID 4002031 City: SALT LAKE CITY State: UT Zip: 84103 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 RUL Pressure 60 09:12 10:12 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 PUL Pressure 60 09:12 10:12 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 3 Low Sulfur Diesel Pressure 60 09:12 10:12 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 4 BACK Low Sulfur Diesel Pressure 60 11:27 12:27 0.00 Pass Yes Tank # 4 Line # 2 TLD-1 4 BACK Low Sulfur Diesel Pressure 60 11:27 12:27 0.00 Pass Yes Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Product Line Tightness Test Satellite Line Tightness Test Page 1 of 1 Work Order: 2381149 Date: 6/26/2025 Site Name/ID: 7-ELEVEN 47167/9447 / 47167/9447 Address: 965 NORTH BECK ST State ID 4002031 City: SALT LAKE CITY State: UT Zip: 84103 Satellite Line # Fueling From - To Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Sat # 1 9 - 9S Low Sulfur Diesel Pressure Included with primary line test Sat # 2 10 - 10S Low Sulfur Diesel Pressure Included with primary line test Sat # 3 11 - 11S Low Sulfur Diesel Pressure Included with primary line test Sat # Sat # Sat # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN 47167/9447 965 NORTH BECK ST State ID 4002031 SALT LAKE CITY UT 84103 47167/9447 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 06/26/2025800-964-1250 RUL PUL Low Sulfur Diesel Low Sulfur DieselVeeder Root PLLD Veeder Root DPLLD Veeder Root PLLD Veeder Root PLLD Veeder Root PLLD 30 2 30 2 2 30 32 2 38 2 UT151 David Mathie NW1-2381149 Low Sulfur Diesel T1:1 T2:1 T3:1 T4 BACK:1 T4 BACK:2 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2381149 Date:6/26/2025 Site Name/ID:7-ELEVEN 47167/9447 Address:965 NORTH BECK ST State ID 4002031 City:SALT LAKE CITY State:UT Zip:84103 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 90 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 90 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 90 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 90 Pass Fail Not Tested 9/ 40 Pass Fail Not Tested 9S/10 40 Pass Fail Not Tested 10S/11 40 Pass Fail Not Tested 11S/ 40 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN 47167/9447 7-ELEVEN, INC. 965 NORTH BECK ST State ID 4002031 SALT LAKE CITY UT 84103 4002031 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 06/26/2025 1 2 3 4 RUL PUL DSL FRT DSL BCK VR450PLUS VR450PLUS VR450PLUS VR450PLUS 11527 11527 11527 11527 89.8 89.8 89.8 89.8 UT151 David Mathie 965 NORTH BECK ST State ID 4002031 7-ELEVEN 47167/9447 965 NORTH BECK ST State ID 4002031, SALT LAKE CITY, UT 8410347167/9447 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 06/26/2025 ANNULAR ANNULAR ANNULAR ANNULAR STP STP SUMP RUL PUL DSL FRT DSL BCK RUL PUL PUL David Mathie 965 NORTH BECK ST State ID 4002031 7-ELEVEN 47167/9447 965 NORTH BECK ST State ID 4002031, SALT LAKE CITY, UT 8410347167/9447 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 06/26/2025 STP STP DSL FRNT DSL BCK UT151 David Mathie 7-ELEVEN 47167/9447 965 NORTH BECK ST State ID 4002031 SALT LAKE CITY, UT 84103 4002031 Tanknology, Inc. 7-ELEVEN, INC. 972-828-7575 06/26/2025 P.O. BOX 711 DALLAS, TX 75221 1 RUL 5 OPW 2 PUL 5 OPW 3 DSL FRT 5 OPW 3 DSL BCK 5 OPW 13 823 13 923 1 HR 0 13 823 13 923 1 HR 0 13 823 13 923 1 HR 0 13 1107 13 1207 1 HR 0 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-ELEVEN 47167/9447 Name :TANKNOLOGY INC. Address :965 NORTH BECK ST State ID 4002031 SALT LAKE CITY, UT 84103 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-328-1348 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :8 Products per Nozzle :3 Tanks Manifolded ?Yes Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) 1 RUL 11527 7660 3867 2 PUL 11527 9201 2326 10:37 0.40 Fail Total 23054 16861 6193 All 10:37 0.40 0.00 Fail Comments: COULD NOT FILL ABOVE .40 MAY BE PUL FILL RISER IN SUMP SEE PIC Tester :David Mathie Test Date :6/26/2025 Signature :Work Order :2381149 WO: 2381149 PVVC tested ==>GAS Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 10 0.0212 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.98 Pass Neg Leak Rate (CFH)0.21 28 0.0594 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.09 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0212 Total -ve LR: 0.0594 Test Date 6/26/2025 Technician Name David Mathie WO #2381149 Facility Name / Loc #7-ELEVEN 47167/9447 47167/9447 Street 965 NORTH BECK ST State ID 4002031 City, St, Zip SALT LAKE CITY, UT 84103 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2381149 Site ID / Name:47167/9447 / 7-ELEVEN 47167/9447 Address:965 NORTH BECK ST State ID 4002031 City:SALT LAKE CITY State:UT Zip:84103 W.O.# NW1-2381149 +AAE- I10100 06/26/25 11:51 AM 7-11 47167/9447 950 N Beck Street SLC UT 84103 Y09291874108002 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 06/26/25 11:51 AM SOFTWARE REVISION LEVEL VERSION 33.58 SOFTWARE+ACM- 342005-010-P- CREATED - 24.07.02.14.24 +AAMAAQ- I20100 06/26/25 11:51 AM 7-11 47167/9447 950 N Beck Street SLC UT 84103 Y09291874108002 IN-TANK INVENTORY TANK PRODUCT VOLUME TC-VOLUME ULLAGE HEIGHT WATER TEMP 1 RUL 7552 0 3975 55.33 0.00 78.61 2 PUL 9140 0 2387 65.65 0.00 80.40 3 DSL 3056 0 8471 27.65 0.00 79.54 4 DSL2 2229 0 9298 22.01 0.00 83.73 +AAMAAQ- I30100 06/26/25 11:51 AM 7-11 47167/9447 950 N Beck Street SLC UT 84103 Y09291874108002 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 RUL INT Normal 2 PUL INT Normal 3 DSL INT Normal 4 DSL2 INT Normal 5 PUL Pipe Sump Normal 6 RUL Sump Normal 7 PUL Sump Normal 8 DSL Front Sump Normal 9 DSL Rear Sump Normal +AAMAAQ- I30200 06/26/25 11:51 AM 7-11 47167/9447 950 N Beck Street SLC UT 84103 Y09291874108002 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 RUL INT 06/26/25 9:11 AM FUEL ALARM 02/10/25 11:20 AM FUEL ALARM 09/28/23 5:23 AM SENSOR OUT ALARM 2 PUL INT 06/26/25 9:28 AM FUEL ALARM 02/10/25 11:50 AM FUEL ALARM 09/28/23 5:23 AM SENSOR OUT ALARM 3 DSL INT 06/26/25 9:36 AM FUEL ALARM 02/10/25 11:52 AM FUEL ALARM 4 DSL2 INT 06/26/25 11:38 AM FUEL ALARM 02/10/25 12:26 PM FUEL ALARM 02/10/25 12:23 PM FUEL ALARM 5 PUL Pipe Sump 06/26/25 9:04 AM FUEL ALARM 02/10/25 12:01 PM FUEL ALARM 6 RUL Sump 06/26/25 9:05 AM FUEL ALARM 04/01/25 3:10 AM FUEL ALARM 03/18/25 6:09 AM FUEL ALARM 03/14/25 5:59 AM FUEL ALARM 03/06/25 11:59 PM FUEL ALARM 02/20/25 11:40 PM FUEL ALARM 02/20/25 9:18 AM FUEL ALARM 02/20/25 8:44 AM FUEL ALARM 02/15/25 9:07 AM FUEL ALARM 02/10/25 11:41 AM FUEL ALARM 01/04/25 10:10 AM FUEL ALARM 7 PUL Sump 06/26/25 9:04 AM FUEL ALARM 02/10/25 12:01 PM FUEL ALARM 8 DSL Front Sump 06/26/25 9:03 AM FUEL ALARM 02/10/25 12:02 PM FUEL ALARM 9 DSL Rear Sump 02/10/25 12:28 PM FUEL ALARM 01/07/25 9:56 AM FUEL ALARM +AAMAAQ- I38200 06/26/25 11:51 AM 7-11 47167/9447 950 N Beck Street SLC UT 84103 Y09291874108002 PRESSURE LINE LEAK ALARM HISTORY REPORT Ln 1: RUL Line PLLD SHUTDOWN ALARM 06/26/25 9:11 AM PLLD SHUTDOWN ALARM 06/26/25 9:05 AM PLLD SHUTDOWN ALARM 06/26/25 8:55 AM GROSS LINE FAIL 06/26/25 8:55 AM PLLD SHUTDOWN ALARM 04/01/25 3:10 AM PLLD SHUTDOWN ALARM 03/18/25 6:09 AM PLLD SHUTDOWN ALARM 03/14/25 5:59 AM PLLD SHUTDOWN ALARM 03/06/25 11:59 PM PLLD SHUTDOWN ALARM 02/20/25 11:40 PM PLLD SHUTDOWN ALARM 02/20/25 9:18 AM PLLD SHUTDOWN ALARM 02/20/25 8:44 AM PLLD SHUTDOWN ALARM 02/15/25 9:07 AM PLLD SHUTDOWN ALARM 02/10/25 11:40 AM GROSS LINE FAIL 02/10/25 11:40 AM PLLD SHUTDOWN ALARM 02/10/25 11:20 AM PLLD SHUTDOWN ALARM 01/04/25 10:10 AM PLLD OPEN ALARM 12/06/24 7:22 PM Ln 2: PUL Line PLLD SHUTDOWN ALARM 06/26/25 8:52 AM GROSS LINE FAIL 06/26/25 8:52 AM PLLD SHUTDOWN ALARM 02/10/25 11:45 AM GROSS LINE FAIL 02/10/25 11:45 AM GROSS LINE FAIL 12/16/24 6:47 PM PLLD SHUTDOWN ALARM 12/16/24 6:47 PM GROSS LINE FAIL 12/06/24 9:27 PM PLLD SHUTDOWN ALARM 12/06/24 9:27 PM PLLD OPEN ALARM 12/06/24 8:56 PM SETUP DATA WARNING 12/06/24 8:09 PM PLLD OPEN ALARM 12/06/24 7:22 PM Ln 3: DSL Front Line PLLD SHUTDOWN ALARM 06/26/25 9:36 AM PLLD SHUTDOWN ALARM 06/26/25 9:03 AM PLLD SHUTDOWN ALARM 06/26/25 8:57 AM GROSS LINE FAIL 06/26/25 8:57 AM PLLD SHUTDOWN ALARM 02/10/25 12:02 PM PLLD SHUTDOWN ALARM 02/10/25 11:48 AM GROSS LINE FAIL 02/10/25 11:48 AM PLLD OPEN ALARM 12/06/24 7:22 PM Ln 4: DSL Rear 1 Line PLLD SHUTDOWN ALARM 06/26/25 11:38 AM PLLD SHUTDOWN ALARM 06/26/25 11:35 AM PLLD SHUTDOWN ALARM 06/26/25 11:19 AM GROSS LINE FAIL 06/26/25 11:19 AM PLLD SHUTDOWN ALARM 06/17/25 9:00 AM PLLD SHUTDOWN ALARM 05/16/25 1:49 AM PLLD SHUTDOWN ALARM 02/10/25 12:44 PM GROSS LINE FAIL 02/10/25 12:44 PM PLLD SHUTDOWN ALARM 02/10/25 12:26 PM PLLD SHUTDOWN ALARM 02/10/25 12:23 PM PERIODIC LINE FAIL 01/22/25 9:16 AM PLLD OPEN ALARM 01/21/25 12:40 PM PERIODIC LINE FAIL 01/21/25 5:05 AM PLLD SHUTDOWN ALARM 01/07/25 9:56 AM PERIODIC LINE FAIL 01/05/25 2:43 PM PERIODIC LINE FAIL 12/26/24 3:20 AM PERIODIC LINE FAIL 12/17/24 7:20 AM SETUP DATA WARNING 12/16/24 7:45 PM PLLD OPEN ALARM 12/16/24 7:45 PM SETUP DATA WARNING 12/16/24 7:31 PM PLLD OPEN ALARM 12/16/24 7:31 PM PLLD OPEN ALARM 12/06/24 9:55 PM Ln 5: DSL Rear 2 Line PLLD SHUTDOWN ALARM 06/26/25 11:20 AM GROSS LINE FAIL 06/26/25 11:20 AM PLLD SHUTDOWN ALARM 02/10/25 12:40 PM GROSS LINE FAIL 02/10/25 12:40 PM PLLD OPEN ALARM 01/21/25 12:45 PM +AAMAAQ- I37400 06/26/25 11:51 AM 7-11 47167/9447 950 N Beck Street SLC UT 84103 Y09291874108002 PRESSURE LINE LEAK TEST HISTORY Ln 1: RUL Line LAST 3.0 PASS: 06/26/25 11:23 AM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 06/01/25 12:26 AM 05/03/25 9:09 AM 04/01/25 9:52 PM 03/02/25 10:48 AM 02/01/25 1:01 AM 01/01/25 8:00 PM 12/07/24 2:26 AM Ln 2: PUL Line LAST 3.0 PASS: 06/26/25 11:33 AM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 05/07/25 7:11 PM 04/01/25 10:11 PM 03/06/25 6:23 AM 02/02/25 4:50 PM 01/01/25 8:41 AM 12/16/24 11:11 PM Ln 3: DSL Front Line LAST 3.0 PASS: 06/26/25 10:56 AM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 06/02/25 10:34 AM 05/01/25 12:28 PM 04/01/25 8:13 AM 03/02/25 1:23 PM 02/02/25 4:31 PM 01/01/25 11:09 AM 12/07/24 7:54 AM Ln 4: DSL Rear 1 Line LAST 3.0 PASS: 06/26/25 11:24 AM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 06/02/25 11:34 AM 05/01/25 3:22 AM 04/03/25 9:30 AM 03/02/25 4:13 AM 02/02/25 3:50 PM 01/03/25 11:06 AM 12/10/24 8:29 AM Ln 5: DSL Rear 2 Line LAST 3.0 PASS: 06/26/25 11:24 AM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 06/02/25 9:18 AM 05/01/25 3:21 AM 04/01/25 8:54 AM 03/04/25 7:48 AM 02/04/25 7:09 AM 01/03/25 10:03 AM 12/17/24 9:04 AM +AAMAAQ- I6SU00 06/26/25 11:51 AM -------------------------------------------------------- +ACoAKgAq- SETUP FOR ALL TANKS +ACoAKgAq- -------------------------------------------------------- ULLAGE DISPLAY MODE: USER ULLAGE FULL ULLAGE LABEL: 100+ACU- ULLAGE USER ULLAGE: 90+ACU- PRINT TC VOLUMES: DISABLED TC REFERENCE TEMPERATURE: 60 DEG F PERIODIC TEST NEEDED WARNINGS: DISABLED DAYS BEFORE PERIODIC WARNING: 25 DAYS BEFORE PERIODIC ALARM: 30 ANNUAL TEST NEEDED WARNINGS: DISABLED DAYS BEFORE ANNUAL WARNING: 355 DAYS BEFORE ANNUAL ALARM: 365 TC DENSITY: DISABLED STICK HEIGHT: DISABLED LEAK TEST REPORT FORMAT: STANDARD LEAK TEST REGION: EPA -------------------------------------------------------- +ACoAKgAq- TANK SETUP +ACoAKgAq- -------------------------------------------------------- --- GENERAL SETUP - TANK 1 --- CONFIGURED: ENABLED LABEL: RUL PRODUCT CODE: 1 PROBE NUMBER: Pb 1: RUL Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11527 GALLONS DIAMETER: 89.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000690 METER DATA PRESENT: ENABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 1 --- MAX VOLUME: 11527 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 542 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 99 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 1 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 1 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 1 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2024-12-06 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 1 --- T1 SIPHON MANIFOLDED TO TANKS: NONE T1 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 1 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 1 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 2 --- CONFIGURED: ENABLED LABEL: PUL PRODUCT CODE: 3 PROBE NUMBER: Pb 2: PUL Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11527 GALLONS DIAMETER: 89.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000690 METER DATA PRESENT: ENABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 2 --- MAX VOLUME: 11527 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 542 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 99 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 2 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 2 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 2 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2024-12-06 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 2 --- T2 SIPHON MANIFOLDED TO TANKS: NONE T2 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 2 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 2 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 3 --- CONFIGURED: ENABLED LABEL: DSL PRODUCT CODE: 4 PROBE NUMBER: Pb 3: DSL Front Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11527 GALLONS DIAMETER: 89.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: ENABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 3 --- MAX VOLUME: 11527 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 542 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 99 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 3 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 3 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 3 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2024-12-06 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 3 --- T3 SIPHON MANIFOLDED TO TANKS: NONE T3 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 3 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 3 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 4 --- CONFIGURED: ENABLED LABEL: DSL2 PRODUCT CODE: 4 PROBE NUMBER: Pb 4: DSL Rear Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11527 GALLONS DIAMETER: 89.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: ENABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 4 --- MAX VOLUME: 11527 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 542 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 99 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 4 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 4 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 4 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2024-12-06 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 89.8 11527 003 44.9 5836 002 67.3 9379 004 22.4 2289 --- TANK 4 --- T4 SIPHON MANIFOLDED TO TANKS: NONE T4 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 4 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 4 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS +AAMAAQ- I70300 06/26/25 11:51 AM LIQUID MODEL SENSOR LABEL MODEL 1 RUL INT Tri-State(Single Float) 2 PUL INT Tri-State(Single Float) 3 DSL INT Tri-State(Single Float) 4 DSL2 INT Tri-State(Single Float) 5 PUL Pipe Sump Tri-State(Single Float) 6 RUL Sump Tri-State(Single Float) 7 PUL Sump Tri-State(Single Float) 8 DSL Front Sump Tri-State(Single Float) 9 DSL Rear Sump Tri-State(Single Float) 10 Tri-State(Single Float) 11 Tri-State(Single Float) 12 Tri-State(Single Float) 13 Tri-State(Single Float) 14 Tri-State(Single Float) 15 Tri-State(Single Float) 16 Tri-State(Single Float) 17 Tri-State(Single Float) 18 Tri-State(Single Float) 19 Tri-State(Single Float) 20 Tri-State(Single Float) 21 Tri-State(Single Float) 22 Tri-State(Single Float) 23 Tri-State(Single Float) 24 Tri-State(Single Float) 25 Tri-State(Single Float) 26 Tri-State(Single Float) 27 Tri-State(Single Float) 28 Tri-State(Single Float) 29 Tri-State(Single Float) 30 Tri-State(Single Float) 31 Tri-State(Single Float) 32 Tri-State(Single Float) 33 Tri-State(Single Float) 34 Tri-State(Single Float) 35 Tri-State(Single Float) 36 Tri-State(Single Float) 37 Tri-State(Single Float) 38 Tri-State(Single Float) 39 Tri-State(Single Float) 40 Tri-State(Single Float) 41 Tri-State(Single Float) 42 Tri-State(Single Float) 43 Tri-State(Single Float) 44 Tri-State(Single Float) 45 Tri-State(Single Float) 46 Tri-State(Single Float) 47 Tri-State(Single Float) 48 Tri-State(Single Float) 49 Tri-State(Single Float) 50 Tri-State(Single Float) 51 Tri-State(Single Float) 52 Tri-State(Single Float) 53 Tri-State(Single Float) 54 Tri-State(Single Float) 55 Tri-State(Single Float) 56 Tri-State(Single Float) 57 Tri-State(Single Float) 58 Tri-State(Single Float) 59 Tri-State(Single Float) 60 Tri-State(Single Float) 61 Tri-State(Single Float) 62 Tri-State(Single Float) 63 Tri-State(Single Float) 64 Tri-State(Single Float) 65 Tri-State(Single Float) 66 Tri-State(Single Float) 67 Tri-State(Single Float) 68 Tri-State(Single Float) 69 Tri-State(Single Float) 70 Tri-State(Single Float) 71 Tri-State(Single Float) 72 Tri-State(Single Float) 73 Tri-State(Single Float) 74 Tri-State(Single Float) 75 Tri-State(Single Float) 76 Tri-State(Single Float) 77 Tri-State(Single Float) 78 Tri-State(Single Float) 79 Tri-State(Single Float) 80 Tri-State(Single Float) 81 Tri-State(Single Float) 82 Tri-State(Single Float) 83 Tri-State(Single Float) 84 Tri-State(Single Float) 85 Tri-State(Single Float) 86 Tri-State(Single Float) 87 Tri-State(Single Float) 88 Tri-State(Single Float) 89 Tri-State(Single Float) 90 Tri-State(Single Float) 91 Tri-State(Single Float) 92 Tri-State(Single Float) 93 Tri-State(Single Float) 94 Tri-State(Single Float) 95 Tri-State(Single Float) 96 Tri-State(Single Float) 97 Tri-State(Single Float) 98 Tri-State(Single Float) 99 Tri-State(Single Float) +AAMAAQ- I78000 06/26/25 11:51 AM PRESSURE LINE LEAK SETUP Q 1: RUL Line PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 250 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: MANUAL SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 1 - RUL PRESSURE OFFSET: 0.0 psi Q 2: PUL Line PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 250 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: MANUAL SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 2 - PUL PRESSURE OFFSET: 0.0 psi Q 3: DSL Front Line PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 250 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: MANUAL SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 3 - DSL PRESSURE OFFSET: 0.0 psi Q 4: DSL Rear 1 Line PIPE TYPE: 2/3 inch Fiberglass LINE LENGTH: 80 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: MANUAL SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 4 - DSL2 PRESSURE OFFSET: 0.0 psi Q 5: DSL Rear 2 Line PIPE TYPE: 2/3 inch Fiberglass LINE LENGTH: 80 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: MANUAL SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 4 - DSL2 PRESSURE OFFSET: 0.0 psi Q 6: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 7: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 8: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 9: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 10: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 11: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 12: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 13: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 14: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 15: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 16: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi +AAMAAQ-9999FF1B+AAMAAQ-9999FF1B+AAMAAQ-9999FF1B+AAMAAQ- I5P500 06/26/25 11:52 AM AUTOMATIC EVENTS - DEVICE TASKS REPORT Event ID - 0003 EVENT - HIGH WATER ALARM : T1: RUL, T2: PUL EVENT - LOW PRODUCT ALARM : T1: RUL, T2: PUL EVENT - FUEL ALARM : L1: RUL INT, L6: RUL Sump ACTION - DEVICE - Ln 1 : RUL Line ------ Event ID - 0004 EVENT - OVERFILL ALARM : T1: RUL, T2: PUL, T3: DSL ACTION - DEVICE - R 6 : Front Overfill Alarm ------ Event ID - 0006 EVENT - HIGH WATER ALARM : T3: DSL EVENT - LOW PRODUCT ALARM : T3: DSL EVENT - FUEL ALARM : L3: DSL INT, L8: DSL Front Sump ACTION - DEVICE - Ln 3 : DSL Front Line ------ Event ID - 0007 EVENT - OVERFILL ALARM : T4: DSL2 ACTION - DEVICE - R 7 : Rear Overfill Alarm ------ Event ID - 0008 EVENT - LOW PRODUCT ALARM : T4: DSL2 EVENT - FUEL ALARM : L4: DSL2 INT, L9: DSL Rear Sump EVENT - HIGH WATER ALARM : T4: DSL2 ACTION - DEVICE - Ln 4 : DSL Rear 1 Line ------ W.O.# NW1-2381149 HLA STATE FORM