Loading...
HomeMy WebLinkAboutDSHW-2025-002993Site Information Finalized Yes Facility Name DCD Heber Transfer Station Facility_ID SW0250 Facility Name DCD Heber Transfer Station Street Address 635 West Airport Road City Heber ZIP Code 84032 County Wasatch County Inspection Date 06-12-2025 Type of Visit Routine Oversite Is the Visit Announced?Yes Weather Conditions Sunny, high of 65 degrees Fahrenheit during the inspection. Inspection Goal To determine compliance with Solid Waste Rules Facility Contact Matt Stalsberg Participants Leobardo Coca Follow Up Inspection Needed?No Recommended Follow Up Date Depart Office Date 06-12-2025 Depart Office time 06:00 AM (-6 GMT) Return to Office Date 06-12-2025 Return to Office time 11:30 AM (-6 GMT) 1. Pre-Inspection Review 1.1 Permit Review Yes Comment Plan of operation was reviewed prior to inspection. 1.2 Annual Report Review No Comment Annual report was not reviewed prior to the inspection. 1.3 Previous Inspection Review Yes Comment Facility was under previous ownership during the most recent inspection. 1.4 Facility Contacts Confirmed Yes Comment Facility contacts have been confirmed. Date Submitted: 06-13-2025 09:57 AM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 1 of 6 1.5 Facility Contacted (If an announced inspection) Yes Comment Facility was contacted prior to the inspection. 1.6 Local Health Contacted No Comment Local health was not contacted for the inspection. 1.7 Other Yes Comment This facility is now owned by Ace Intermountain Recycling. SW250 2. Facility / Operational Controls (1-Good, 5-Poor) 2.1 Litter 1 2.2 Roads 1 2.3 Gate House Operations 1 2.4 Vectors 1 2.5 Communications 1 2.6 Recycling Area 1 2.7 Fugitive Dust Control 3 2.8 Waste Inspection Area 1 2.9 Scavenging Control 1 2.10 Open Burning NA 2.11 Fences, Gates, Locks, Access Control 1 2.12 Working Face 1 2.13 Daily - Soil NA 2.14 Daily - Alternative NA 2.15 Leachate Collection System NA 2.16 Other NA Comment (Required)Facility keeps things clean and moving. Facility may consider other options for dust control within the transfer station building. 3. Signs Required / Properly Posted 3.1 Operating Days / Hours Yes 3.2 Directions & Procedures Yes 3.3 Emergency Numbers Yes 3.4 List of Unacceptable Materials Yes 3.5 Other Yes Date Submitted: 06-13-2025 09:57 AM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 2 of 6 Comment (Required)All signs in the facility clearly communicated waste handling procedures, hazards, waste not accepted, hours of operation, emergency contacts, etc. 4. Operator / Representative / Employees 4.1 On-site While Open Yes 4.2 Training Yes 4.3 Other N/A Comment (Required)Operators were onsite and available during the inspection. 5. Monitoring 5.1 Methane N/A 5.2 Random Inspections Yes 5.3 Leachate N/A 5.4 Ground Water N/A 5.5 Other N/A Comment (Required)Random inspections area being conducted on a regular basis. 6. Drainage / Erosion 6.1 Water Run-on Yes 6.2 Water Run-off Yes 6.3 Other N/A Comment (Required)Water run-off surfaces are being drained into a storm water pond. 7. Proper Storage / Isolation / Disposal 7.1 Special Waste N/A 7.2 Batteries Yes 7.3 Hazardous Waste N/A 7.4 Infectious Waste N/A 7.6 Dead Animals N/A 7.7 Asbestos N/A 7.8 Bulky Waste Yes 7.9 Contaminated Soil N/A 7.10 Ash N/A 7.11 Sludge N/A 7.12 Other Comment (Required)Facility has proper separation and storage for recyclable metals and batteries. Date Submitted: 06-13-2025 09:57 AM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 3 of 6 8. Cover 8.1 Intermediate N/A 8.2 Final N/A 8.3 Vegetation N/A 8.4 Other N/A Comment (Required)No cover required at this facility. 9. Inspection Records 9.1 Random Inspection Report Yes 9.2 Gas Monitoring System N/A 9.3 Surface Drainage Control Yes 9.4 Daily Records Yes 9.5 Weight or Volumes Yes 9.6 Intermediate Cover N/A 9.7 Final Cover N/A 9.8 Self Inspection (Quarterly Reports) Yes 9.9 Deviation From Plans N/A 9.10 Permit, Permit Application, and Rules Available Yes 9.11 Other N/A Comment (Required)All inspection records were available and up to date. 10. Monitoring / Sampling / Analysis Records 10.1 Explosive Gas Monitoring N/A 10.2 Leachate Sampling & Treatment N/A 10.3 Ground Water Sampling Results N/A 10.4 Other N/A Comment (Required)No monitoring or sampling analysis records are required at this location. 11. Special Waste Records 11.1 Lab Analysis Results N/A 11.2 Manifests N/A 11.3 Treatment Certification N/A 11.4 Paint Filter Test Results N/A Date Submitted: 06-13-2025 09:57 AM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 4 of 6 11.5 Onsite Treatment Documentation N/A 11.6 Other N/A Comment (Required)This facility only accepts Construction or Demolition waste. 12. Waste Tires 12.1 Acceptance procedures for Waste Tires N/A 12.2 Waste Tire Pile Segregated N/A 12.3 Estimated Quanitity of Waste Tires No Number of Tires 12.4 Waste Tire Fund Training N/A Comment (Required)Waste tires are not accepted at this facility. 13 Other Items 13.1 Notice of Inspections Form Completed and Signed N/A 13.2 N/A 13.3 N/A 13.4 N/A Comment (Required)Not required at this time. 14. Special Permit Requirements 14.1 N/A 14.2 N/A 14.3 N/A Comment (Required)No special permit requirements for this facility. General Comments Comments Additional fugitive dust control needed within transfer building. Overall, the facility was very clean, had great communication, and was determined to be in compliance with solid waste rules and the conditions of the Plan of Operation. DWMRC Inspector Signature Date Submitted: 06-13-2025 09:57 AM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 5 of 6 DWMRC Inspector Name Bryan Watt Date/Time 06-13-2025 Photos Attach Photos Date Submitted: 06-13-2025 09:57 AM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 6 of 6