Loading...
HomeMy WebLinkAboutDSHW-2025-002992Site Information Finalized Yes Facility Name Juab Rural Development Agency Landfill Facility_ID SW0137 Facility Name Juab Rural Development Agency Landfill Street Address Approximately 5 miles west of Nephi, south off State Route 132 City Nephi ZIP Code 84648 County Juab County Inspection Date 06-11-2025 Type of Visit Routine Oversite Is the Visit Announced?Yes Weather Conditions 95 and sunny Inspection Goal To determine compliance with Solid Waste Permitting and Management Rules. Facility Contact John Crippen, Landfill Manager Juab Rural Development Agency Participants Alex Milne, DWMRC Nate Nicolodemos, DWMRC Nick Painter, JRDA Follow Up Inspection Needed?N/A Recommended Follow Up Date Depart Office Date 06-11-2025 Depart Office time 11:00 AM (-6 GMT) Return to Office Date 06-11-2025 Return to Office time 01:30 PM (-6 GMT) 1. Pre-Inspection Review 1.1 Permit Review Yes Comment The Permit (DSHW-2016-013883) was reviewed. The facility is permitted to accept MSW ( 20 ton daily limit), commercial waste, industrial waste, C&D waste, special waste (incinerator ash, dead animals, asbestos), conditionally exempt SQG haz waste, and PCBs. Burning is permitted. Daily covered is required. Gas monitoring is required. 1.2 Annual Report Review Yes Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 1 of 10 Comment The 2024 Annual Report was submitted and reviewed. 100% of the waste received was from Juab County. Total Materials Received is recorded to be 11,819.00 tons. 1.3 Previous Inspection Review Yes Comment The 04/20/2023 Inspection Report and Letter were reviewed. No issues were observed. 1.4 Facility Contacts Confirmed Yes Comment John Crippen is the primary contact. 1.5 Facility Contacted (If an announced inspection) Yes Comment John Crippen was notified of the inspection via email on 05/13/2025. A follow-up call was made on 06/10/2025 and a voicemail was left. 1.6 Local Health Contacted Yes Comment Eric Larson of the Central Utah Public Health Department was notified of the inspection via email on 05/13/2025. 1.7 Other N/A Comment N/A 2. Facility / Operational Controls (1-Good, 5-Poor) 2.1 Litter 3 2.2 Roads 1 2.3 Gate House Operations 1 2.4 Vectors 1 2.5 Communications 1 2.6 Recycling Area 3 2.7 Fugitive Dust Control 1 2.8 Waste Inspection Area 1 2.9 Scavenging Control 1 2.10 Open Burning 1 2.11 Fences, Gates, Locks, Access Control 1 2.12 Working Face 1 2.13 Daily - Soil 1 2.14 Daily - Alternative NA 2.15 Leachate Collection System NA 2.16 Other NA Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 2 of 10 Comment (Required)Uncovered waste beyond the working face was observed. The green waste pile is burned yearly with Fire Marshal approval. Metals are separated for recycling. However, large amounts of metal piles were observed. The recycling area also contained waste and other material. The scale house is fully staffed, roads are well maintained, and minimal wind-blown litter was observed. 3. Signs Required / Properly Posted 3.1 Operating Days / Hours Yes 3.2 Directions & Procedures Yes 3.3 Emergency Numbers No 3.4 List of Unacceptable Materials Yes 3.5 Other N/A Comment (Required)The facility displays several signs throughout. An emergency number was not displayed. The sign located near the landfill cells was not clear and shows all waste goes in the same area. More clear signage is needed. 4. Operator / Representative / Employees 4.1 On-site While Open Yes 4.2 Training N/A 4.3 Other N/A Comment (Required)The facility was fully staffed at the time of the inspection. Please ensure staff are present when customers are unloading at the working face. 5. Monitoring 5.1 Methane Yes 5.2 Random Inspections Yes 5.3 Leachate N/A 5.4 Ground Water N/A 5.5 Other N/A Comment (Required)The facility does not have a groundwater monitoring requirement. The facility is required to conduct quarterly gas monitoring. Random load inspections are being conducted. 6. Drainage / Erosion 6.1 Water Run-on Yes 6.2 Water Run-off Yes 6.3 Other N/A Comment (Required)The facility maintains adequate drainage and erosion controls. 7. Proper Storage / Isolation / Disposal 7.1 Special Waste Yes Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 3 of 10 7.2 Batteries N/A 7.3 Hazardous Waste N/A 7.4 Infectious Waste N/A 7.6 Dead Animals Yes 7.7 Asbestos N/A 7.8 Bulky Waste N/A 7.9 Contaminated Soil N/A 7.10 Ash N/A 7.11 Sludge N/A 7.12 Other N/A Comment (Required)The facility is permitted to accept dead animals. Dead animals are immediately buried upon arrival at the MSW (household waste) cell. 8. Cover 8.1 Intermediate Yes 8.2 Final N/A 8.3 Vegetation N/A 8.4 Other N/A Comment (Required)MSW is being covered daily. C&D waste is not being covered at least monthly. 9. Inspection Records 9.1 Random Inspection Report Yes 9.2 Gas Monitoring System Yes 9.3 Surface Drainage Control N/A 9.4 Daily Records Yes 9.5 Weight or Volumes Yes 9.6 Intermediate Cover N/A 9.7 Final Cover N/A 9.8 Self Inspection (Quarterly Reports) N/A 9.9 Deviation From Plans N/A 9.10 Permit, Permit Application, and Rules Available No 9.11 Other N/A Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 4 of 10 Comment (Required)Quarterly inspection reports were not reviewed. The facility maintains gas monitoring records. A copy of the Permit was not available, but a copy was emailed to the facility by the inspector on 06/11/2025. Waste receipt records are kept in the scale house. The facility will start implementing a cover log. 10. Monitoring / Sampling / Analysis Records 10.1 Explosive Gas Monitoring Yes 10.2 Leachate Sampling & Treatment N/A 10.3 Ground Water Sampling Results N/A 10.4 Other Comment (Required)The facility does not have a groundwater monitoring requirement. The facility is required to conduct quarterly gas monitoring. The facility maintains gas monitoring records in the scale house. 11. Special Waste Records 11.1 Lab Analysis Results N/A 11.2 Manifests N/A 11.3 Treatment Certification N/A 11.4 Paint Filter Test Results N/A 11.5 Onsite Treatment Documentation N/A 11.6 Other N/A Comment (Required)No special waste records were reviewed. 12. Waste Tires 12.1 Acceptance procedures for Waste Tires N/A 12.2 Waste Tire Pile Segregated N/A 12.3 Estimated Quanitity of Waste Tires No Number of Tires 12.4 Waste Tire Fund Training Yes Comment (Required)Section 2.3.8 of the Plan of Operation states (4) tires are accepted at a time and placed at the bottom of the working face of the Class II or Class IV cell. The Waste Tire Recycling Act (the Act) prohibits the landfilling of waste tires. Waste tires should be segregated and stored for recycling. The Act allows the acceptance of up to 12 waste tires per person per day for recycling. The facility was educated on the Act and provided instructions via a follow-up email on how to request the removal of waste tires. 13 Other Items 13.1 Notice of Inspections Form Completed and Signed N/A Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 5 of 10 13.2 N/A 13.3 N/A 13.4 N/A Comment (Required)N/A 14. Special Permit Requirements 14.1 N/A 14.2 N/A 14.3 N/A Comment (Required)N/A General Comments Comments Uncovered waste beyond the working face was observed. C&D waste is not being covered at least monthly. The green waste pile is burned yearly with Fire Marshal approval. Metals are separated for recycling. However, large amounts of metal piles were observed. The recycling area also contained waste and other material. Confusing signage was observed near the landfill cells. The scale house is fully staffed, roads are well maintained, and minimal wind-blown litter was observed. The facility was educated in waste tire management. DWMRC Inspector Signature DWMRC Inspector Name Alex Milne Date/Time 06-11-2025 Photos Attach Photos View of the facility's front entrance signage. Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 6 of 10 View of the facility scale house. The scale house is fully staffed during operating hours. View of the back side of the landfill. Exposed waste is visible. Additional view of exposed waste heading up toward the landfill. View of concrete behind the landfill. Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 7 of 10 Additional view of concrete behind the landfill. View of the working face of the C&D cell. C&D waste does not receive cover at least monthly. View of facility's signage within the landfill area. The signage is not clear and shows the C&D cell to be straight ahead with the MSW cell, which is incorrect. View of the MSW cell. The cell was actively being worked on at the time of the inspection. Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 8 of 10 Additional view of the MSW cell. View of one of the metal recyclables piles. This pile also included C&D waste. View of various mixed waste piles ranging from metals, appliances, lawn mowers, generators, C&D waste, etc. View of the facility's large white appliance pile stored to be picked up by a metal recycler. Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 9 of 10 Overview of miscellaneous waste and metals. Additional view of appliances being stored and awaiting pick up from a metal recycler. Date Submitted: 06-11-2025 04:51 PM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 10 of 10